displaying 1000 best results Help
Search results for: JINGLE
-
Comparative analysis of balancing of V6 engines with common- and split-pin crankshafts
PublicationAn analysis of balancing of V6 engines equipped with split-pin crankshafts with any cylinder bank angle based on the mathematical relations derived in the paper was carried out. A comparison of the quality of their balancing with engines equipped with common-pin crankshafts was also carried out. The bank angle ranges beneficial for balancing of moments of inertia forces in reciprocating motion were determined. A mathematical relation...
-
Pipeline geometry defects in high resolution pig's data
PublicationMost of the pipelines have been inspected at least once using intelligent pigging. The problem of specific software for interactive presentation, analysis and comparison of features revealed during the consecutive geometry surveys is emphasized. Capabilities of a simultaneous measurement of internal geometry and metal loss features in a single run are illustrated. Advantages of application of statistical characteristics of both...
-
Free convection of water-Al2O3 nanofluid from horizontal porous coated tube
PublicationNanofluids are expected to enhance heat transfer in many thermal systems. Present efforts are concentrated on boiling heat transfer of nanofluids, although single phase convection is of key importance in various appliances such as car radiators or heating systems. This paper presents experimental results of heat transfer during free convection of water-Al3O3 nanofluid from horizontal tube covered with metallic porous coating. Contrary...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublicationThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Multiscaled Hybrid Features Generation for AdaBoost Object Detection
PublicationThis work presents the multiscaled version of modified census features in graphical objects detection with AdaBoost cascade training algorithm. Several experiments with face detector training process demonstrate better performance of such features over ordinal census and Haar-like approaches. The possibilities to join multiscaled census and Haar features in single hybrid cascade of strong classifiers are also elaborated and tested....
-
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
Zastosowanie XMPP w roli protokołu komunikacji multimedialnej w rozproszonym systemie monitoringu
PublicationPrzedstawiono rozproszony system monitoringu bazujący na protokole XMPP, omówiono architekturę i założenia, na których opiera się projekt tego systemu. Przedstawiono cechy protokołu XMPP ze zwróceniem uwagi na te najbardziej istotne w kontekście omawianego zastosowania. Przedyskutowano zagadnienie transmisji multimediów w czasie rzeczywistym z wykorzystaniem rozszerzenia Jingle/XMPP. Zwrócono także uwagę na techniczne aspekty związane...
-
Analytical Steady-State Model of the Pipeline Flow Process
PublicationThe paper addresses the issue of modeling the flow process in transmission pipelines. A base model used for numerical simulation is introduced. Under certain assumptions concerning steady state analysis, the differential equations describing the process are solved analytically for two cases: zero and nonzero inclination angle α. These equations describe a constant flow rate and a corresponding distribution of the pressure along...
-
Model obliczania kosztu cyklu życia obiektu na przykładzie budynku mieszkalnego jednorodzinnego
PublicationW artykule przedstawiono model obliczania kosztu cyklu życia budynku mieszkalnego jednorodzinnego oraz wskazano możliwości ograniczenia wydatków związanych z jego użytkowaniem w okresie trzydziestu lat. Celem prezentowanej analizy rachunku kosztu cyklu życia jest porównanie i ocena kosztów nabycia i użytkowania domu realizowanego według alternatywnych technologii z uwzględnieniem przyjętych rozwiązań w zakresie pozyskania energii,...
-
Impacts in case of triple unilaterally constrained system
PublicationThe this paper focus on the behaviour of a “rigid” body biting into another “rigid” body, with some nonzero relative velocity. In the presently considered case, the introduced collision appears between a selected element of a multibody structure and its reference body being interpreted as the motionless ground. Instead of the classic case, described in a number of dissertations, where a single impacting contact is considered, three...
-
Abnormal cytological findings - Female, 37 - Cell image [4200730008419901]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [6260730021884381]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 37 - Cell image [4200730008418711]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inflammatory disease of uterus, unspecified - Female, 28 - Cell image [7050730000132481]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026857841]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [6260730021887571]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026858451]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026854541]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026854851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 38 - Cell image [7020730007134891]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 26 - Cell image [6130730026855131]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026858841]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026852671]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [613073002685461]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 32 - Cell image [5050730010507471]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 43 - Cell image [6300730028258581]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 44 - Cell image [6300730028254131]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026853441]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026851941]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [62607300218871]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [7040247104944011]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 45 - Cell image [7060729599329251]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026853531]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 41 - Cell image [5050730010501191]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 32 - Cell image [6300730028256321]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 29 - Cell image [4200730008417201]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [6260730021882161]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026856971]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [626073002188491]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026857451]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Neuroendocrine carcinoma, NOS - Female, 67 - Tissue image [6260730021889791]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Epitaph of John Schroeder in St. Mary's Church in Gdańsk
Open Research DataThe data set concerns epigraphy. It refers to the epitaph placed in St. Mary’s Church in Gdańsk, that is dedicated to John Schröder, son of Simon. John, as he was a single, erected this epitaph for himself. Data set contains one general photo of the epitaph, transcription of its text in Latin, its translation in Polish, and the biography of the deceased,...
-
Ln2(SeO3)2(SO4)(H2O)2 (Ln=Sm, Dy, Yb): A Mixed‐Ligand Pathway to New Lanthanide(III) Multifunctional Materials Featuring Nonlinear Optical and Magnetic Anisotropy Properties
PublicationBottom-up assembly of optically nonlinear and magnetically anisotropic lanthanide materials involving precisely placed spin carriers and optimized metal-ligand coordination offers a potential route to developing electronic architectures for coherent radiation generation and spin-based technologies, but the chemical design historically has been extremely hard to achieve. To address this, we developed a worthwhile avenue for creating...
-
Pawlak's flow graph extensions for video surveillance systems
PublicationThe idea of the Pawlak's flow graphs is applicable to many problems in various fields related to decision algorithms or data mining. The flow graphs can be used also in the video surveillance systems. Especially in distributed multi-camera systems which are problematic to be handled by human operators because of their limited perception. In such systems automated video analysis needs to be implemented. Important part of this analysis...
-
Hydrothermal reactions: From the synthesis of ligand to new lanthanide 3D-coordination polymers
PublicationThe organic ligand 2,5-piperazinedione-1,4-diaceticacid (H2PDA) was synthesized under hydrothermal conditions starting from the iminodiacetic acid and catalyzed by oxalic acid. The X-ray powder diffraction data indicates that the compound crystallizes in the P21/c space group as reported in the literature. The ligand was also characterized by elemental analysis, magnetic nuclear resonance, infrared spectroscopy and thermogravimetric...
-
Client-side versus server-side geographic data processing performance comparison: Data and code
PublicationThe data and code presented in this article are related to the research article entitled “Analysis of Server-side and Client-side Web-GIS data processing methods on the example of JTS and JSTS using open data from OSM and Geoportal” (Kulawiak et al., 2019). The provided 12 datasets include multi-point and multi-polygon data of different scales and volumes, representing real-world geographic features. The datasets cover the area...
-
Impact of rotor geometry optimization on the off-design ORC turbine performance
PublicationThe paper describes the method of CFD based Nelder-Mead optimization of a 10 kW single-stage axial turbine operating in an ORC system working on R7100. The total-to-static isentropic efficiency is defined as an objective function. Multi-point linear regression is carried out to determine the significance of the objective function arguments and to pick up the set of particular variables and characteristic quantities (e.g. flow angles)...
-
Improving the Quality of Magnetic Signature Reproduction by Increasing Flexibility of Multi-Dipole Model Structure and Enriching Measurement Information
PublicationThe paper presents the construction of a multi-dipole model that allows reproducing magneticsignatures of ferromagnetic objects. The virtual object used in the paper is an ellipsoid, which is the sourceof synthetic data. To make the situation more realistic, noise is added to the synthetic data. Two significantimprovements compared to previous work are presented. Three-axial magnetometers are introduced insteadof uniaxial magnetometers....
-
Variable-fidelity response feature surrogates for accelerated statistical analysis and yield estimation of compact microwave components
PublicationAccounting for manufacturing tolerances is an essential part of a reliable microwave design process. Yet, quantification of geometry and/or material parameter uncertainties is challenging at the level of full-wave electromagnetic (EM) simulation models. This is due to inherently high cost of EM analysis and massive simulations necessary to conduct the statistical analysis. Here, a low-cost and accurate yield estimation procedure...
-
COMPARISON OF HEAT TRANSFER CHARACTERISTICS IN SURFACE COOLING WITH BOILING MICROJETS OF WATER, ETHANOL AND HFE7100
PublicationThe basis of microjet technology is to produce laminar jets which when impinging the surface have a very high kinetic energy at the stagnation point. Boundary layer is not formed in those conditions, while the area of film cooling has a very high turbulence resulting from a very high heat transfer coefficient. Applied technology of jet production can result with the size of jets ranging from 20 to 500μm in breadth and 20 to 100μm...