Publications
Filters
total: 854
Catalog Publications
-
Modelling long-term technological transition of Polish power system using MARKAL: Emission trade impact
PublicationThe need for technological transition of electricity production becomes a global problem. However, in coal-dominated Polish power system this need is even more crucial than anywhere, since technical lifetime of the most domestic power plants is ending. In this paper, the impact of the EU Emission Trading Scheme (EU ETS) for CO2 combined with sulfur dioxide (SO2) and nitrogen oxides (NOx) emission trading mechanism on power technology...
-
Energy policy and the role of bioenergy in Poland
PublicationPrzedstawiono sytuacje energetyczną kraju. Omówiono poszczególne sektory wytwarzania energii oraz zapotrzebowania na energię i paliwa. Omówiono przekształcenia sektorów energetycznych w Polsce na przestrzeni lat 1990-2002. Na tym tle przedstawiono techniczne, ekonomiczne, społeczne i prawne aspekty rozwoju energetyki źródeł odnawialnych a w szczególności opartych o bioenergię. Przedstawiono wnioski dla Polski płynące z dotychczasowych...
-
Solar Photovoltaic Energy Optimization and Challenges
PublicationThe study paper focuses on solar energy optimization approaches, as well as the obstacles and concerns that come with them. This study discusses the most current advancements in solar power generation devices in order to provide a reference for decision-makers in the field of solar plant construction throughout the world. These technologies are divided into three groups: photovoltaic, thermal, and hybrid (thermal/photovoltaic)....
-
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
Thermodynamic and economic analysis of nuclear power unit operating in partial cogeneration mode to produce electricity and district heat
PublicationThis paper presents the methodology of techno-economic analysis for a nuclear unit operating in partial cogeneration mode and its application for the case study: a nuclear power plant planned in Poland. The research objectives were: to propose EPR, AP1000 and ESBWR nuclear condensing-extraction turbine systems modifications required for operation in cogeneration, to determine optimal heat production and heat transport line (HTL)...
-
Underfrequency Load Shedding: An Innovative Algorithm Based on Fuzzy Logic
PublicationIn contemporary power systems, the load shedding schemes are typically based on disconnecting a pre-specified amount of load after the frequency drops below a predetermined value. The actual conditions at the time of disturbance may largely dier from the assumptions, which can lead to non-optimal or ineective operation of the load shedding scheme. For many years, increasing the eectiveness of the underfrequency load shedding (UFLS)...
-
Operation of the Hybrid Photovoltaic-Battery System on the Electricity Market—Simulation, Real-Time Tests and Cost Analysis
PublicationThis paper presents research on a hybrid photovoltaic-battery energy storage system, declaring its hourly production levels as a member of a balancing group submitting common scheduling unit to the day-ahead market. It also discusses the variability of photovoltaic system generation and energy storage response. The major research questions were whether the operation of a hybrid photovoltaic-battery energy storage system is viable...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW artykule przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oceniono skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania proponowanego wyłącznika różnicowoprądowego.
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW referacie przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oszacowano wpływ tego odkształcenia na próg fibrylacji serca. Analizowano skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania zaproponowanego...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Energy Efficiency and Economic Policy: Comprehensive Theoretical, Empirical, and Policy Review
PublicationIn this paper, we analyze the role of economic policy in prompting energy efficiency. This study reviews three aspects, theoretical, empirical, and existing policies to evaluate the relationship of energy efficiency and economic policy. This study furthermore identifies the existing issues from a policy perspective in energy efficiency. Although not all public policies may be justified, it suggests that these types of financial...
-
Simulation of the Dynamics of Renewable Energy Sources with Energy Storage Systems
PublicationThe intermittency of renewable energy sources (RES) constitutes a challenge for effective power system control. Fossil-fuel-based units offering ancillary power services to meet the short-term power imbalance are a financial and environmental burden for the society. Energy storage systems (ESS) can be the solution in view of the electricity market development and growing environmental concern. The major questions are, in what circumstances...
-
Magazynowanie energii elektrycznej i gospodarka wodorowa
PublicationW artykule dokonano przegl ą du aktualnych technologii magazynowania energii elektrycznej oraz zestawiono uzyskiwane parametry w aspekcie zastosowa ń w zasobnikach systemowych. Przedstawiono studium mo ż liwo ś ci magazynowania energii z odnawialnych ź róde ł energii (O Ź E) w zasobnikach akumulatorowych i elektrowniach szczytowo-pompowych w Polsce. Omówiono tak ż e mo ż liwo ś ci wykorzystania...
-
Automatic Identification System (AIS) Dynamic Data Integrity Monitoring and Trajectory Tracking Based on the Simultaneous Localization and Mapping (SLAM) Process Model
PublicationTo enhance the safety of marine navigation, one needs to consider the involvement of the automatic identification system (AIS), an existing system designed for ship-to-ship and shipto- shore communication. Previous research on the quality of AIS parameters revealed problems that the system experiences with sensor data exchange. In coastal areas, littoral AIS does not meet the expectations of operational continuity and system availability,...
-
Electric shock hazard in circuits with variable-speed drives
PublicationThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Immunity of residual current devices to the impulse leakage current in circuits with variable speed drives
PublicationThis paper concerns reliability of supply in variable speed drive circuits with residual current devices. During normal operation of these circuits high value of leakage current causes unwanted tripping of residual current devices. Immunity of residual current devices to the impulse leakage current should be evaluated. The system for testing of residual current devices and results of the test are presented
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublicationLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
The investment risk forecasting in a local energy market
PublicationThe paper considers the general problems faced when evaluating the risk of investing in a local energy market by computer tools. The proposal formulated for the emerging local energy markets suggests broadening the method of evaluating investment risk so as to include elements of cluster analysis. The paper also discusses the significance of estimating investment risk in market terms and the importance and range of the local energy...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublicationA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublicationThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublicationPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
The Application of a Multi-Criteria Decision-Making for Indication of Directions of the Development of Renewable Energy Sources in the Context of Energy Policy
PublicationThis paper presents the application of multi-criteria decision-making (MCDM) for evaluating what technologies using renewable energy sources (RES) for electricity production have the chance to develop in Poland under the current socio-economic conditions. First, the Analytical Hierarchy Process (AHP) method was used to determine the weights of the optimization criteria. Five main criteria and 30 sub-criteria were identified. Next,...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublicationThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Ampacity of power cables exposed to solar radiation – recommendations of standards vs. CFD simulations
PublicationThe aim of the paper is to evaluate the ampacity of a low-voltage single power cable according to: 1) recommendations of the standard IEC 60287, 2) a Computational Fluid Dynamics method, implemented in Ansys software; and comparison of the results obtained for these two cases. Moreover, limitations of recommendations of the above mentioned standard are indicated.
-
CFD-based evaluation of current-carrying capacity of power cables installed in free air
PublicationEvaluation of current-carrying capacity of power cables and selection of cross-sectional area of their conductors are mainly performed in accordance with requirements of EN, IEC or IEEE standards. However, these standards do not provide all methods of cables installation and location which occur in practice. Thus, in some cases, performance of advanced modeling of various thermal phenomena, affecting power cables current-carrying...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Numerical and experimental investigation of thermal convection near electric devices with vertical channels
PublicationThis paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels – thermal convection is the most intensive then. Air velocity vectors...
-
Hybrid Multi-Criteria Method of Analyzing the Location of Distributed Renewable Energy Sources
PublicationThis paper presents the development and the application of a hybrid multi-criteria method, the combination of the Analytic Hierarchy Process (AHP), and numerical taxonomy (NT),to support the decision making on the location of distributed renewable energy sources meetingvarious types of assessment criteria. Finding criteria weights, using the AHP method, eliminates thedisadvantage of NT—which, in current form, is defined by its...
-
Energy storage device based on flywheel, power converters and Simulink real-time
PublicationThis electronic document is a “live” template and already defines the components of your paper [title, text, heads, etc.] in its style sheet. Paper presents information on Energy Storage Device based on Flywheel and bi-directional IGBT Power Converters – designed for LINTE^2 laboratory owned by Gdansk University of Technology in Poland. Paper is divided into four sections. First section of the paper provides introductory information...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Selection of optimal location and rated power of capacitor banks in distribution network using genetic algorithm
PublicationIn this paper, the problem of placement and rated power of capacitor banks in the Distribution Network (DN) is considered. We try to suggest the best places for installing capacitor banks and define their reactive power. The considered formulation requires the optimization of the cost of two different objectives. Therefore the use of properly multiobjective heuristic optimization methods is desirable. To solve this problem we use...
-
Security Information Sharing for the Polish Power System
PublicationThe Polish Power System is becoming increasingly more dependent on Information and Communication Technologies which results in its exposure to cyberattacks, including the evolved and highly sophisticated threats such as Advanced Persistent Threats or Distributed Denial of Service attacks. The most exposed components are SCADA systems in substations and Distributed Control Systems in power plants. When addressing this situation...
-
Modelling Long‐Term Transition from Coal‐Reliant to Low‐Emission Power Grid and District Heating Systems in Poland
PublicationEnergy systems require technological changes towards climate neutrality. In Poland, where the power system is dominated by outdated coal-fired power plants, efforts to minimize the environmental impact are associated with high costs. Therefore, optimal paths for the development of the energy sector should be sought in order to achieve ambitious long-term strategic goals, while minimizing the negative impact on the consumers’ home...
-
The FEM analysis of pressure installation elements after simulated accidental overheating
PublicationThe paper presents innovative analysis focused on the safety aspects of existing pressure installation operation after overheating accidents. Results presented here can be applied in decision-making process concerning further operation of existing pressure installation after cooling system failure. In this paper the results of FEM analysis performed for a straight pipe and 90 degrees elbow, made of super duplex stainless steel,...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
EHV transmission lines wires location on line operation issues - case studies
PublicationTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublicationEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Reactive Energy Billing in Operator Tariffs in Poland
PublicationThe paper describes the current method of reactive energy billing in the tariffs of distribution grid operators in Poland. The current solutions are subject to critical assessment. Issues related to the motivation effect of the current solutions on consumers are analysed. Problems that occur in relation with connecting distributed generators to the distribution grid and challenges related to prosumer billing are indicated.
-
A Novel Spatio–Temporal Deep Learning Vehicle Turns Detection Scheme Using GPS-Only Data
PublicationWhether the computer is driving your car or you are, advanced driver assistance systems (ADAS) come into play on all levels, from weather monitoring to safety. These modern-day ADASs use various assisting tools for drivers to keep the journey safe; these sophisticated tools provide early signals of numerous events, such as road conditions, emerging traffic scenarios, and weather warnings. Many urban applications, such as car-sharing...