Wyniki wyszukiwania dla: TOWER EARTHING MEASUREMENT
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublikacjaThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
Example of practical use of vibration measurement results - study of settlement of the Wisłoujście Tower
PublikacjaW pracy przedstawiono wyniki identyfikacji parametrów posadowienia wieży Twierdzy Wisłoujście. Badanie oparto na zidentyfikowanych w pomiarach częstotliwościach drgań swobodnych wieży. Przyjęto prosty model dynamiczny obiektu, dobrze opisujący jego zachowanie.
-
OCENA UZIEMIEŃ SŁUPÓW LINII ELEKTROENERGETYCZNYCH ZWŁASZCZA POSADOWIONYCH NA GRUNTACH O WYSOKIEJ REZYSTYWNOŚCI
PublikacjaW artykule została omówiona problematyka pomiaru i oceny właściwości uziemień słupów linii elektroenergetycznych z wykorzystaniem przebiegów wolno-i szybkozmiennych. Uzyskanie odpowiednio niskiej wartości rezystancji uziemienia słupa posadowionego na gruncie o rezystywności powyżej 1000Ωm może być trudne. Praca zawiera analizę zmian właściwości statycznych i udarowych uziemień w funkcji rezystywności...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublikacjaLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Earth wires currents calculation by tableau analysis
PublikacjaThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublikacjaElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
PublikacjaReferat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa...
-
Neutral earthing reactor protection
PublikacjaThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Vibration-Based Investigation of a Historic Bell Tower to Understand the Occurrence of Damage
PublikacjaABSTRACT The paper presents a survey of the historic Arch-cathedral bell tower in Vilnius induced by the appearance of cracks in the structure after a new bell system installation. An attempt is undertaken to identify the reason for the crack occurrence and to check a possible crack influence on global structural behaviour. The research is based on dynamic measurements made in the tower during ambient vibrations and during vibrations...
-
Assessing historical church tower asymmetry using point cloud spatial expansion
PublikacjaChurch towers are key cultural heritage. In theory, towers are vertical, while facade elements are symmetrically positioned around the tower axis. However, during service of a structure, building and lifetime conditions cause deviations, with associated risks. Laser scanning point clouds can be used to assess the structural state but a universal approach was missing. The proposed algorithm first estimates the tower inclination,...
-
Basic sensitivity analysis of a telecommunication tower complementing standard reinforcement design process
PublikacjaThis paper presents straightforward sensitivity assessment of a telecommunication tower. The analysis is set toidentify the elements of the tower which may be reinforced with the greatest structural advantage. As current expertopin ions on structural redesign of similar structures due to a planned addition of extra loads are mainly based ondeterministic computations or engineering intuition,...
-
GPR investigation of the strengthening system of a historic masonry tower
PublikacjaIn this paper the condition assessment of the strengthening system of a masonry tower was carried out by the GPR method. The study provided unique experimental data acquired during measurements of the reinforced concrete frame embedded in masonry walls. Conducted numerical and experimental investigations were focused on the phenomenon of the diffraction-refraction scattering of the electromagnetic energy. A hyperbola resulting...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublikacjaTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
MEASUREMENT OF NOISE IN SUPERCAPACITORS
PublikacjaA developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
-
Numerical investigation on dynamic response of a steel lattice tower under various seismic events
PublikacjaThe present paper presents the results of the numerical study designed to investigate the soil-structure flexibility effects on modal parameters (i.e. fundamental frequencies) and time-history analysis response (represented by the top relative displacements) of a 46.8 m high steel lattice tower subjected to a number of ground motions including also one mining tremor. In addition to the fixed-base condition, three different soil...
-
Impulse and high frequency methods of lighting earthing testes.
PublikacjaUziemienia projektowane dla prądów zwarciowych nie zawsze są właściwe do odprowadzania prądów piorunowych, gdzie należy brać pod uwagę impedancję uziemień. W pracy porównano metody: udarową oraz wysokiej częstotliwości zastosowane do oceny przydatności uziemień odgromowych.
-
Reliability assessment of an OVH HV power line truss transmission tower subjected to seismic loading
PublikacjaThe study focuses on the reliability of a transmission tower OS24 ON150 + 10, an element of an OVH HV power line, under seismic loading. In order to describe the seismic force, the real-life recording of the horizontal component of the El Centro earthquake was adopted. The amplitude and the period of this excitation are assumed random, their variation is described by Weibull distribution. The possible space state of the phenomenon...
-
The Zręb Tower proposals for saving the ruins
PublikacjaZabytkowa baszta pod Zrębem w latach siedemdziesiątych XX wieku uległa awarii, zawalił się dach oraz częściowo ściany. W pracy przedstawiono propozycje zabezpieczenia budowli przed postępującą destrukcją.
-
Geodesic monitoring of tower and mast structures
PublikacjaW artykule przedstawiono obciążenia jakim są poddawane konstrukcje wieżowe i masztowe. Opisano zakres oraz wymagania dotyczące pomiarów geodezyjnych przeprowadzanych w czasie eksploatacji konstrukcji smukłych. Wskazano metody pomiaru oraz zaprezentowano niektóre sposoby pomiaru w praktyce. Zamieszczono wyniki pomiarów przemieszczeń elektrowni wiatrowej o mocy 2 MW i wysokości elementu wsporczego 80 m oraz zaprezentowano pomiary...
-
Mechanical-Level Hardware-In-The-Loop and Simulation in Validation Testing of Prototype Tower Crane Drives
PublikacjaIn this paper, the static and dynamic simulations, and mechanical-level Hardware-In-the-Loop (MHIL) laboratory testing methodology of prototype drive systems with energy-saving permanent-magnet electric motors, intended for use in modern construction cranes is proposed and described. This research was aimed at designing and constructing a new type of tower crane by Krupiński Cranes Company. The described research stage was necessary...
-
Diagnosis of the Vilnius Cathedral Tower by modal analysis
PublikacjaPraca dotyczy wstępnych badań diagnostycznych dzwonnicy katedralnej w Wilnie. Analiza oparta jest na pomiarach drgań obiektu, wykonanych podczas wymuszeń losowych (ruch uliczny, wiatr etc.) oraz podczas bicia dzwonów. Na ich podstawie określono kilka pierwszych częstości drgań swobodnych wieży. Zaobserwowano znaczne wzmocnienie amplitudy drgań z pierwszą częstością własną w wynikach pomiarów wykonywanych przy biciu dzwonów. Wskazuje...
-
Modelling and Identification of Tower Type Historic Buildings
PublikacjaW pracy omawia się problemy modelowania i identyfikacji zabytkowych murowanych budowli wieżowych na przykładzie wieży Twierdzy Wisłoujście. Przedstawiono analizę modalną na podstawie dwukierunkowych pomiarów przyspieszeń na 9 poziomach wieży. Wyniki analizy posłużyły do identyfikacji modelu matematycznego budowli w postaci sztywnego bloku na podłożu sprężystym. Wykorzystano hierarchiczną procedurę opartą na analizie wrażliwości.
-
Earthing effective length for low and high amplitudes of lightning impulse currents
PublikacjaUziemienia w systemie elektroenergetycznym mogą być bardzo rozległe, zwłaszcza ze względu powszechne stosowanie połączeń ekwipotencjalizacyjnych. Ocena tak rozległych systemów z punktu widzenia ich przydatności do celów ochrony odgromowej jest dość trudna, ponieważ tylko część takiego rozległego systemu bierze udział w rozpraszaniu prądu piorunowego w gruncie. Ta część uziomu jest nazywana jego długością efektywną. W pracy zamieszczono...
-
Novel PCSE-based approach of inclined structures geometry analysis on the example of the Leaning Tower of Pisa
Publikacja -
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublikacjaA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublikacjaThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
A system for acoustic field measurement employing cartesian robot
PublikacjaA system setup for measurements of acoustic field, together with the results of 3D visualisations of acoustic energy flow are presented in the paper. Spatial sampling of the field is performed by a Cartesian robot. Automatization of the measurement process is achieved with the use of a specialized control system. The method is based on measuring the sound pressure (scalar) and particle velocity (vector) quantities. The aim of the...
-
Impulse Measurements of Tower Earthings of Overhead Transmission Lines
PublikacjaPrzepisy wymagają okresowego badania uziemień słupów elektroenergetycznych linii przesyłowych. pomiary takie metodami klasycznymi niskiej częstotliwości wymagają odłączania uziomów od konstrukcji słupa, co wiąże się z wyłączaniem linii. wykorzstanie metody udarowej do oceny uziemień nie wymaga odłączania uziomów i może byc przeprowadzane podczas pracy linii.
-
Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures
PublikacjaThis paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment...
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublikacjaThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublikacjaThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Nondestructive global corrosion measurement using guided wavefield data
PublikacjaMetallic structures often face degradation, and corrosion ranks among the most prevalent forms of deterioration. Accurate quantification of corrosion is crucial, especially for structures exposed to harsh environmental conditions, such as marine vessels and offshore installations. Because the traditional measurement methods based on scanning by ultrasonic gauge are time-consuming and provide only rough information on the thickness...
-
Electrical Simulations of the SIS100 Superconducting Dipole and Quadrupole Circuits: Transients, Earthing and Failure Modes
PublikacjaThe 100 Tm superconducting synchrotron SIS100 is the main accelerator of the international Facility for Antiproton and Ion Research (FAIR) currently under advanced construction in Darmstadt, Germany. The SIS100 dipole circuit which creates the magnetic field required to bend the beam, consists of 108 dipoles distributed over six arc sections of the ring. The magnetic field for the beam focusing is generated by three individual...
-
Laser-textured cross-hatched surface topography analysis with evaluation of high-frequency measurement noise
PublikacjaThe precision of surface roughness determination using ISO 25178 parameters relies on various factors that directly impact the measurement process. In industry applications, the contactless roughness measurement reduces data collection time. However, it introduces several potential errors, including those stemming from the environment. One of the main types of errors encountered during topography analysis is measurement noise,...
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublikacjaIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Low-coherence method of hematocrit measurement
PublikacjaDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
A measurement system for children endurance tests
PublikacjaThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
World's tower namely, how to build a 1200 metre tall house
Publikacja..
-
Identification of the Vistula Mounting tower model using measured modal data
PublikacjaW pracy przedstawiono problem identyfikacji pięcioparametrowego modelu zabytkowej wieży twierdzy Wisłoujście. Poszukiwane parametry wyznaczono jako rozwiązanie problemu minimalizacji błędu średniokwadratowego pomierzonych dwóch pierwszych częstości i pierwszej postaci drgań własnych. Do tego celu wykorzystano hierarchiczną procedurę minimalizacji przy zastosowaniu analizy wrażliwości. Analiza numeryczna potwierdziła efektywność...
-
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublikacjaThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublikacjaAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublikacjaDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...