Filtry
wszystkich: 11406
wybranych: 8079
-
Katalog
- Publikacje 8079 wyników po odfiltrowaniu
- Czasopisma 405 wyników po odfiltrowaniu
- Konferencje 33 wyników po odfiltrowaniu
- Osoby 143 wyników po odfiltrowaniu
- Projekty 9 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 67 wyników po odfiltrowaniu
- Wydarzenia 5 wyników po odfiltrowaniu
- Dane Badawcze 2664 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: high current measurement
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Measurement cell - current density analysis.
PublikacjaW pracy przedstawiono model celki do pomiarów elektrycznych parametrów szkliwa i innych tkanek zęba. Wyniki otrzymano za pomocą metody elementu skończonego. Wykazano, że możliwa do osiągnięcia dokładność pomiaru jest zdeterminowana przez prąd upływu celki.
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Current measurement and analysis for induction motor diagnostics
PublikacjaPrzedstawiono sposób diagnozowania łożysk tocznych w silnikach indukcyjnych z wykorzystaniem pomiarów i analizy prądu zasilającego silnik. Zaprezentowano metodę pomiarową i opracowania danych diagnostycznych. Uzyskano zgodność częstotliwości składowych widma prądu otrzymanych z badań teoretycznych i eksperymentalnych.Podano wyniki badań łożysk o róznych uszkodzeniach i prawdopodobieństwa poprawnych diagnoz.
-
Current divider-based nanosecond high current pulse measuring systems
PublikacjaThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Visual measurement system for chosen parameters of current collectors
PublikacjaA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublikacjaMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Modular high precision high current source for special applications — Simulation and verification
PublikacjaThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublikacjaW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
Measurement microsystem for high impedance spectroscopy of anticorrosion coatings
PublikacjaW artykule przedstawiono mikrosystem do pomiarów bardzo dużych impedancji ukierunkowany na identyfikację parametrów powłok antykorozyjnych metodą spektroskopii impedancyjnej. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych zastosowano w nim technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich, od ćHz, przy zachowaniu prostej konstrukcji...
-
New concept of a measurement probe for high impedance spectrocopy
PublikacjaArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
Errors of a Linear Current Approximation in High-Speed PMSM Drives
PublikacjaCurrent sampling techniques and predictive algorithms used in the digital control of electric drives rely on a simple mathematical model that assumes linear current changes upon constant supplying voltages. This paper identifies rotor movement as a factor that makes this assumption invalid when the rotor covers an angular distance of a few tens of degrees during the control interval duration. The errors of the linear current approximation...
-
The influence of parameters of input probe on the error of high impedance measurement
PublikacjaW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublikacjaThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublikacjaZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
Theoretical analysis of current induced by high-energetic radiation in dielectric materials
PublikacjaW pracy poddano analizie mechanizmy generacji i rekombinacji nośników ładunku w obecności wysokoenergetycznego promieniowania. Przedstawiono zależności gęstości prądu elektrycznego od natężenia promieniowania i napięcia polaryzujacego próbkę.
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
A High-Efficient Measurement System With Optimization Feature for Prototype CMOS Image Sensors
PublikacjaIn this paper, a gray-scale CMOS image sensor (CIS) characterization system with an optimization feature has been proposed. By using a very fast and precise control of light intensity, based on the pulsewidth-modulation method, it is avoided to measure the illuminance every time. These features accelerate the multicriteria CIS optimization requiring many thousands of measurements. The system throughput is 2.5 Gb/s, which allows...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublikacjaIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublikacjaIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
Evaluation of high-frequency roughness measurement errors for composite and ceramic surfaces after machining
PublikacjaPrecise characterisation of surface topography is of the greatest importance since many factors directly affect the accuracy of the whole measurement process. In this paper, the variety of surface topographies from machined composite and ceramic workpieces was studied with a special emphasis on the measurement results. Surfaces were subjected to the ground diamond, honing and milling processes. Measurement results were analysed...
-
Feature-Based Characterisation of Turned Surface Topography with Suppression of High-Frequency Measurement Errors
Publikacja -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
High step-up continuous input current LCCT-Z-source inverters for fuel cells
PublikacjaFalowniki typu Z (ZSI) przeznaczone są do układów wymagających szerokiej zmiany wzmocnienia napięciowego, np. w energetyce odnawialnej. Ostatnio zaproponowano w literaturze zmienione struktury - falowniki typu Trans-Z (TZSI) oraz typu T (TSI) - w których dzięki zastosowaniu dławików sprzężonych uzyskano lepsze wzmocnienie niż w ZSI. W tym artykule przedstawiono ideę rozszerzonej struktury TZSI. Zaproponowano dwie nowe struktury...
-
Laser-textured cross-hatched surface topography analysis with evaluation of high-frequency measurement noise
PublikacjaThe precision of surface roughness determination using ISO 25178 parameters relies on various factors that directly impact the measurement process. In industry applications, the contactless roughness measurement reduces data collection time. However, it introduces several potential errors, including those stemming from the environment. One of the main types of errors encountered during topography analysis is measurement noise,...
-
High-quality Experiment Dedicated to microGravity Exploration, Heat Flow and Oscillation Measurement from Gdańsk
PublikacjaIn this paper we propose HEDGEHOG (High-quality Experiment Dedicated to microGravity Exploration, Heat flow and Oscillation measurement from Gdańsk) REXUS experiment to investigate vibrational and heat flow phenomena during the whole (ascent, microgravity phase, descent and recovery) flight of a sounding rocket. First, a proposed system of cantilever beams is discussed to study dynamic behaviour of dummy payload. Dimensioning has...
-
Investigating Layered Topological Magnetic Materials as Efficient Electrocatalysts for the Hydrogen Evolution Reaction under High Current Densities
PublikacjaDespite considerable progress, high-performing durable catalysts operating under large current densities (i.e., >1000 mA/cm2) are still lacking. To discover platinum group metal-free (PGMfree) electrocatalysts for sustainable energy, our research involves investigating layered topological magnetic materials (semiconducting ferromagnets) as highly efficient electrocatalysts for the hydrogen evolution reaction under high current...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Temperature measurement using NIR camera with automatic adjustment of integration time for monitoring high-temperature industrial processes
Publikacja -
Modeling the impact of discretizing rotor angular position on computation of field-oriented current components in high speed electric drives
PublikacjaModern drives consist of alternating current electric motors, and the field-oriented control (FOC) of such motors enables fast, precise, and robust regulation of a drive's mechanical variables such as torque, speed, and position. The control algorithm, implemented in a microprocessor, requires feedback from motor currents, and the quality of this feedback is essential to a drive's control properties. Motor phase currents are sampled...
-
Single-dopant organic white electrophosphorescent diodes with very high efficiency and its reduced current density roll-off
PublikacjaW pracy opisano konstrukcję wysokowydajnej diody elektrofosforescencyjnej zawierającej domieszkę organicznego kompleksu platyny PtL2Cl (L oznacza organiczny ligand). Dioda emituje światło białe które pochodzi od ekscymerów świecących w czerwieni i wzbudzonych monomerów świecących w części niebieskiej widma. Kwantowa wydajność świecenia diody wynosi ok. 15% i słabo maleje ze wzrostem gęstości płynącego prądu elektrycznego.
-
Improved Procedures for Feature-Based Suppression of Surface Texture High-Frequency Measurement Errors in the Wear Analysis of Cylinder Liner Topographies
Publikacja -
O zastosowaniu metody prądów wirowych do technicznego pomiaru własności elektrycznych i magnetycznych metali = About application of eddy current method for technical measurement of electric and magnetic properties of metals
PublikacjaOpisano wyniki badań nad wykorzystaniem efektu prądów wirowych do badania własności elektrycznych i magnetycznych metali. Badania wykonano za pomocą sondy różnicowej. Wyniki pomiarów zależności częstotliwościowej wykonane dla modelowych materiałów porównano z wynikami modelowania metodą elementów skończonych.
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublikacjaThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublikacjaDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublikacjaConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublikacjaModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublikacjaIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Study of prototype multi-pole non-salient field winding for high speed brushless synchronous generator
PublikacjaIn this paper a non-salient field winding for a brushless synchronous generator working with high speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a six-pole cylindrical-rotor with distributed field winding has been proposed. Comparison study of salient and prototype non-salient field winding has been carried out. Chosen simulation and measurement results of the generator...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublikacjaCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
The concept of a new two-stage fuse for high power pulse forming
PublikacjaThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...