Filtry
wszystkich: 2608
wybranych: 2048
-
Katalog
- Publikacje 2048 wyników po odfiltrowaniu
- Czasopisma 27 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Osoby 44 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Kursy Online 21 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 460 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ACTIVE MAGNETIC BEARINGS
-
Tuning of High Spin Ground State and Slow Magnetic Relaxation within Trimetallic Cyanide‐Bridged {Ni II x Co II 9− x [W V (CN) 8 ] 6 } and {Mn II x Co II 9− x [W V (CN) 8 ] 6 } Clusters
Publikacja -
Simulation of the Remanence Influence on the Transient States of the Single-Phase Transformer Including Feedback Preisach Model
PublikacjaThis paper presents the results of the experimental and simulation investigation concerning the influence of remanence in the core of a single-phase transformer at the no-load transient state. Experimental studies consisted of the discharge of the capacitor through the primary winding at several different values of the residual magnetic flux. The paper presents a model of the transformer test system, taking into account the magnetic...
-
Compliance tests of the polymer layers used as hydrodynamic bearing coatings
PublikacjaOperational experience and scientific investigations results showed that polymer lined hydrodynamic bearings can withstand more severe operating conditions compared than white metal bearings. PTFE and PEEK-based coatings are the most frequently used as Babbitt alternatives. Both polymers differ significantly from the each other in material properties. According to catalogue data compression modulus of PTFE, it is about an order...
-
Finite Element Method Applied in Electromagnetic NDTE: - A Review
PublikacjaThe paper contains an original comprehensive review of finite element analysis (FEA) applied by researchers to calibrate and improve existing and developing electromagnetic non-destructive testing and evaluation techniques, including but not limited to magnetic flux leakage (MFL), eddy current testing, electromagnetic-acoustic transducers (EMATs). Premium is put on the detection and modelling of magnetic field, as the vast majority...
-
Electromagnetic Field Associated With Dermoscope Magnets May Affect the Safety of Cardiac Implanted Electronic Devices Patients
PublikacjaDermoscopy is currently used as an auxiliary tool in general dermatology. Since some commercially available dermoscopes have built-in magnets, electromagnetic interference (EMI) may occur when examining cardiac implantable electronic devices (CIED) patients. The aim of the study was to create maps of electromagnetic fields defining a safe distance in terms of EMI. The study was performed in laboratory conditions using measuring...
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublikacjaPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
Wzbudzone siły wewnętrzne : skutki upr0szczonego modelowania zakrzywionej estakady sprężonej
Publikacjathe paper presents problems, which were encountered during the construction of a southern road bypass of city gdansk. after prestressing and removing formwork, the contractor spotted, that some of outer bearings are detached. performed analysis showed that, this situation was caused by the usage of a simplified, straight beam model during design phase. the paper shows the influence of a curved in plane prestressed system on internal...
-
Frontispiece: Tuning of High Spin Ground State and Slow Magnetic Relaxation within Trimetallic Cyanide‐Bridged {Ni II x Co II 9− x [W V (CN) 8 ] 6 } and {Mn II x Co II 9− x [W V (CN) 8 ] 6 } Clusters
Publikacja -
Metoda diagnostyki łożysk na podstawie analizy przebiegów prądu i napięcia zasilającego silnik indukcyjny.
PublikacjaW niniejszej monografii przedstawiono oryginalne podejście i realizację diagnostyki łożysk silników indukcyjnych przy użyciu metody opartej na pomiarach i analizie iloczynu wartości chwilowych prądu i napięcia zasilającego maszyny. Uzyskane wyniki badań eksperymentalnych na obiektach rzeczywistych okazały się zbieżne z wynikami badań symulacyjnych i potwierdziły, że powstanie uszkodzeń łożysk w silniku skutkuje pojawieniem się...
-
Study of Integer Spin S = 1 in the Polar Magnet β-Ni(IO3)2
PublikacjaPolar magnetic materials exhibiting appreciable asymmetric exchange interactions can potentially host new topological states of matter such as vortex-like spin textures; however, realizations have been mostly limited to half-integer spins due to rare numbers of integer spin systems with broken spatial inversion lattice symmetries. Here, we studied the structure and magnetic properties of the S = 1 integer spin polar magnet β-Ni(IO3)2...
-
Spin and Orbital Effects on Asymmetric Exchange Interaction in Polar Magnets: M(IO3)2 (M = Cu and Mn)
PublikacjaMagnetic polar materials feature an astonishing range of physical properties, such as magnetoelectric coupling, chiral spin textures, and related new spin topology physics. This is primarily attributable to their lack of space inversion symmetry in conjunction with unpaired electrons, potentially facilitating an asymmetric Dzyaloshinskii–Moriya (DM) exchange interaction supported by spin–orbital and electron–lattice coupling. However,...
-
Uncertainty analysis of measuring system for instantaneous power research
PublikacjaThe paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped...
-
Deducing 1D concentration profiles from EPR imaging: A new approach based on the concept of virtual components and optimization with the genetic algorithm
Publikacja -
A new technique with high reproducibility to estimate renal oxygenation using BOLD-MRI in chronic kidney disease
Publikacja -
The Role of Specific Side Groups and pH in Magnetization Transfer in Polymers
Publikacja -
NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI
Publikacja -
The Analysis of Hyperfine Shifts of Mono-Ligand High-Spin Cobalt(II) Pyrazolylborate Complexes
Publikacja -
Absolute configurations of C34 and C35 of antibiotic niphimycin A
PublikacjaThe relative configurations of four stereogenic centers of the C33-C42 fragment of niphimycin A were assigned as 2S*, 3R*, 4S* and 6S*, based upon (1)H NMR analysis with double-quantum filtered COSY and nuclear Overhauser spectroscopy experiments. These data were then correlated with absolute configurations at C36 and C38 of niphimycin A, which were declared previously as 36S and 38S [3]. This allowed for the assignment of the...
-
Stereostructure of mycoheptin A2
PublikacjaThe absolute configurations of all the stereogenic centers of the antibiotic mycoheptin A2 were established upon previouslyelaborated general procedure, consisting of DQF-COSY, NOESY, ROESY, HSQC and HMBC experiments as major tools. Thestructure of mycoheptin A2 without stereochemistry of its aglycone has been reported before.
-
Reaction of bis[bis(tri-tert-butoxysilanethiolato)cadmium(II)] with 3,5-dimethylpyridine - 113Cd NMR Solution study
PublikacjaAnaliza 113Cd NMR dla reakcji bis[bis(tri-tert-butoksysilanotiolanu)kadmu(II)] z 3,5-dimetylopirydyną została przeprowadzona w roztworze benzenu-d6 i toluenu-d8. Otrzymane wyniki wskazują, że w roztworze istnieje równowaga pomiędzy powstającymi mieszanymi kompleksami kadmu z ligandami siarkowymi i azotowymi.
-
Spectral assignment and proton transfer studies ofN-(R-salicylidene)-1-amino-1-deoxy-d-sorbitols
Publikacja -
Theoretical analysis of solvent effects on nitrogen NMR chemical shifts in oxazoles and oxadiazoles
Publikacja -
Stereostructure of mycoheptin A2
PublikacjaThe absolute configurations of all the stereogenic centers of the antibiotic mycoheptin A2 were established upon previously elaborated general procedure, consisting of DQF-COSY, NOESY, ROESY, HSQC and HMBC experiments as major tools. The structure of mycoheptin A2 without stereochemistry of its aglycone has been reported before.
-
Absolute configurations of C34 and C35 of antibiotic niphimycin A
PublikacjaThe relative configurations of four stereogenic centers of the C33-C42 fragment of niphimycin A were assigned as 2S*, 3R*, 4S* and 6S*, based upon 1H NMR analysis with double-quantum filtered COSY and nuclear Overhauser spectroscopy experiments. These data were then correlated with absolute configurations at C36 and C38 of niphimycin A, which were declared previously as 36S and 38S [3]. This allowed for the assignment of the absolute...
-
The structure, including stereochemistry, of levorin A1
PublikacjaThe constitution and stereostructure of levorin A1 1, an aromatic heptaeneantifungal antibiotic, was established on the basis of NMR studies, which contained DQFCOSY,ROESY, HSQC and HMBC experiments. Mycosamine moiety was used as an internalchiral probe to determine the absolute configuration of levorin A1 stereogenic centers: 13S,15R, 17S, 18R, 19S, 21R. The relative configuration of the remaining stereogenic centers wasassigned...
-
Correlation between the Reactivity and Spectroscopic Properties of N-Substituted Secondary Thioamides. New Intramolecular N• •H+• •N Binding Approach and Proton Complexes Based on Thioamide Ligation
PublikacjaFrom a comparison of chem. shifts and wavenumbers of several secondary thioamides and amides having monocationic substituents attached to thiocarbamoyl or carbamoyl groups by a polymethylene chain, new intramol. unconventional N···H+···N H bonding effects were discovered. It is argued that the CH2-N rotation is hindered and two +H···NHMe nonequiv. protons occur in a proton spectrum of hydrochloride RCH2C(S)NH(CH2)3NHMe-HCl...
-
Intramolecular transformation of an antifungal antibiotic nystatin A1 into its isomer, iso-nystatin A1 - structural and molecular modeling studies
PublikacjaNystatin A1, a polyene macrolide antifungal antibiotic, in a slightly basic or acidic solution undergoes an intramolecular transformation, yielding a structural isomer, the translactonization product, iso-nystatin A1 with lactone ring diminished by two carbon atoms. Structural evidence is provided by advanced NMR and Mass Spectrometry (MS) studies. Molecular dynamics simulations and quantum mechanics calculations gave the insight...
-
Monosaccharides as internal probes for the determination of the absolute configuration of 2-butanol
PublikacjaD-dlukoza, D-mannoza i L-ramnoza zostały poddane reakcji z mieszaniną racemiczną 2-butanolu. Otrzymane w ten sposób glikozydy były analizowane za pomocą spektroskopii NMR, z wykorzystaniem eksperymentów COSY i NOESY. Analiza konformacyjna wiązania glikozydowego (dokonana w oparciu o modelowanie molekularne i heteronuklearne stałe sprzężenia) wraz z analizą sprzężeń dipolowych obserwowanych w widmie NOESY umożliwiła określenie konfiguracji...
-
Study of the Effect of Filling Thermoplastic Medical Polyurethane with PVA, PLA or Diatomite on the Relaxation Times Distributions of 1H NMR
PublikacjaIn this work, to characterize the mobility of diferent sections of the macromole‑ cules of polyurethane (PUR), polyvinyl alcohol (PVA), and polylactic acid (PLA), as well as the density of crosslinks of the polymer chains when using fllers, we used the distributions of spin–lattice and spin–spin relaxation times for the protons. It is shown that the rigidity of the thermoplastic polymers depends on the sizes of the granules of...
-
Superconductivity and itinerant ferromagnetism of Y9Co7 probed by ac susceptibility
PublikacjaThe ac magnetic susceptibility of a single crystal sample of the compound Y9Co7 has been measured in applied dc fields ranging from 0–6.7 kOe by utilizing a tunnel diode resonator circuit. In agreement with previous measurements on this material, a superconducting transition has been observed to occur at TSC ≈ 2.5 K. A broad maximum has been observed in the zero field susceptibility measurements from 2.5 K < T < 8 K and its behavior...
-
Electronic structure and magnetism of samarium and neodymium adatoms on free-standing graphene
PublikacjaThe electronic structure of selected rare-earth atoms adsorbed on a free-standing graphene was investigated using methods beyond the conventional density functional theory (DFT+U, DFT +HIA, and DFT+ED). The influence of the electron correlations and the spin-orbit coupling on the magnetic properties has been examined. The DFT+U method predicts both atoms to carry local magnetic moments (spin and orbital) contrary to a nonmagnetic...
-
Wide-field magnetometry using nitrogen-vacancy color centers with randomly oriented micro-diamonds
PublikacjaMagnetometry with nitrogen-vacancy (NV) color centers in diamond has gained significant interest among researchers in recent years. Absolute knowledge of the three-dimensional orientation of the magnetic field is necessary for many applications. Conventional magnetometry measurements are usually performed with NV ensembles in a bulk diamond with a thin NV layer or a scanning probe in the form of a diamond tip, which requires a...
-
Impact analysis of surface roughness of the plate-plate measuring system on resistance torque in interaction with MR fluid
PublikacjaMagnetorheological (MR) fluids are complex suspensions of magnetic particles in a non-magnetic carrier fluid. They exhibit ‘smart’ properties that enable them to change their rheological parameters in response to a change in the external magnetic field applied. This behavior is used in some engineering solutions, e.g. MR clutches or brakes. For such systems to work correctly, the resistance torque achieved by contact with the...
-
Field-induced suppression of charge density wave in GdNiC2
PublikacjaWe report the specific heat, magnetic, magnetotransport, and galvanomagnetic properties of polycrystalline GdNiC 2 . In the intermediate temperature region above T N = 20 K, we observe large negative magnetoresistance due to Zeeman splitting of the electronic bands and partial destruction of a charge density wave ground state. Our magnetoresistance and Hall measurements show that at low temperatures a magnetic field-induced transformation from...
-
Estimation of Broadband Complex Permeability Using SIW Cavity-Based Multimodal Approach
PublikacjaIn this article, an attractive multimodal substrate integrated waveguide (SIW) based methodology is presented for the characterization of magnetic materials in the broadband microwave frequency. The proposed approach employs a modified feed under-coupled SIW cavity instead of conventional feed over-coupled multiple SIW cavities; it uses the modified closedform expression, developed from the first principle to consider the effect...
-
Study of microstress state of P91 steel using complementary mechanical Barkhausen, magnetoacoustic emission, and X-ray diffraction techniques
PublikacjaThe paper deals with assessment of microstress state of martensite P91 steel using three complementary techniques: mechanical Barkhausen emission, magnetoacoustic emission (MAE), and X-ray diffraction (XRD) profile analysis. Magnetic coercivity Hc and microstructure were investigated with inductive magnetometry and magnetic force microscopy (MFM), respectively. Internal stress level of P91 steel was modified by heat treatment....
-
Prediction of the Mechanical Properties of P91 Steel by Means of Magneto-acoustic Emission and Acoustic Birefringence
PublikacjaThe paper describes an application of nondestructive volumetric magnetic and ultrasonic techniques for evaluation of the selected mechanical parameter variations of P91 steel having direct influence on its suitability for further use in critical components used in power plants. Two different types of deformation processes were carried out. First, a series of the P91 steel specimens was subjected to creep and second, one to plastic...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Sharp transitions in low-number quantum dots Bayesian magnetometry
PublikacjaWe consider Bayesian estimate of static magnetic field, characterized by a prior Gaussian probability distribution, in systems of a few electron quantum dot spins interacting with infinite temperature spin environment via hyperfine interaction. Sudden transitions among optimal states and measurements are observed. Usefulness of measuring occupation levels is shown for all times of the evolution, together with the role of entanglement...
-
The homometallic warwickite V 2 OBO 3
PublikacjaThe synthesis, structure and elementary magnetic characterization of the homometallic warwickite V2OBO3 are reported. The material adopts the orthorhombic warwickite structure type at room temperature, space group Pnma (No. 62) with lattice parameters a = 9.2317(1) Å, b = 3.1172(1) Å, and c = 9.5313(1) Å. Temperature-dependent magnetic susceptibility, electrical resistivity, and specific heat measurements show anomalies near 35 K,...
-
Determination of Mathematical Model Parameters of a Medium Frequency Transformer
PublikacjaThe paper presents the results of experimental studies of the medium frequency transformer. The object of the research was a prototype of a single-phase transformer with a core made of ferrite I-core elements and windings made of Litz conductors. The research was carried out to determine the parameters of the transformer's mathematical model. The scope of the tests included determining the magnetic hysteresis loop and measuring...
-
Fe3–xInSnxO6 (x = 0, 0.25, or 0.5): A Family of Corundum Derivatives with Sn-Induced Polarization and Above Room Temperature Antiferromagnetic Ordering
PublikacjaThree new double corundum derivative compounds, Fe3−xInSnxO6 (x = 0. 0.25, or 0.5), were synthesized at high pressure and temperature (6 GPa and 1400− 1450 °C). All of the compounds order antiferromagnetically well above room temperature (TN = 608, 532, and 432 K for x = 0, 0.25, and 0.5, respectively). The x = 0 phase crystallizes as centrosymmetric R3̅c, but the inclusion of closed-shell d10 Sn4+ induces x = 0.25 and 0.5 to crystallize...
-
Potential Skyrmion Host Fe(IO3)3: Connecting Stereoactive Lone-Pair Electron Effects to the Dzyaloshinskii-Moriya Interaction
PublikacjaMagnetic skyrmions, which are topologically distinct magnetic spin textures, are gaining increased attention for their unique physical properties and potential applications in spintronic devices. Here we present a design strategy for skyrmion host candidates based on combinations of magnetic spin, asymmetric building units having stereoactive lone-pair electrons, and polar lattice symmetry. To demonstrate the viability of the proposed...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublikacjaThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
Accuracy of a low-cost autonomous hexacopter platforms navigation module for a photogrammetric and environmental measurements
PublikacjaA photogrammetry and environmental measurements from an unmanned aerial vehicle (UAV) are a low-cost alternative for a traditional aerial photogrammetry. A commercial off-the-shelf products (COTS) offers a variety of cheap components that a suitable to be used on board a UAV. In this paper a low-cost navigation module based on Ublox NEO-M8N GPS and Pixhawk flight controller have been described, as a main extrinsic parameters source...
-
The Dominant Influence of Plastic Deformation Induced Residual Stress on the Barkhausen Effect Signal in Martensitic Steels
PublikacjaThe paper presents the results of investigation of the influence of plastic deformation on the magnetic properties of martensitic steel (P91 grade). The properties of the hysteresis loops as well as of the Barkhausen effect (BE) signal are analysed for both tensile and compressive loading up to ε = 10% of plastic deformation. The choice of the steel and of the deformation range is unique, since for such combination one can expect...
-
Acid–Base Equilibrium and Self-Association in Relation to High Antitumor Activity of Selected Unsymmetrical Bisacridines Established by Extensive Chemometric Analysis
PublikacjaUnsymmetrical bisacridines (UAs) represent a novel class of anticancer agents previously synthesized by our group. Our recent studies have demonstrated their high antitumor potential against multiple cancer cell lines and human tumor xenografts in nude mice. At the cellular level, these compounds affected 3D cancer spheroid growth and their cellular uptake was selectively modulated by quantum dots. UAs were shown to undergo metabolic...
-
Mobilny system do detekcji obiektów ferromagnetycznych z magnetometrami pompowanymi optycznie
PublikacjaW pracy przedstawiono mobilny system do detekcji obiektów ferromagnetycznych. Każdy obiekt ferromagnetyczny zaburza w swoim otoczeniu równomierność pola magnetycznego Ziemi. Zaburzenie to może być zmierzone za pomocą precyzyjnych magnetometrów. W prezentowanym mobilnym systemie zastosowano magnetometry pompowane optycznie pracujące w układzie różnicowym. W pracy opisano magnetometryczny system do detekcji obiektów ferromagnetycznych,...
-
Antiferromagnetic Order in the Rare-Earth Halide Perovskites CsEuBr3 and CsEuCl3
PublikacjaBulk CsEuBr3 and CsEuCl3 are experimentally shown to be magnetic semiconductors that order antiferromagnetically at Néel temperatures of 2.0 K and 1.0 K, respectively. Given that nanoparticles and thin films of CsEuCl3 have been reported to order ferromagnetically at a similar temperature, our observation of antiferromagnetic ordering in CsEuBr3 and CsEuCl3 expands the possible applications of halide perovskites to now include...
-
Optical Magnetometry Based on Nanodiamonds with Nitrogen-Vacancy Color Centers
PublikacjaNitrogen-vacancy color centers in diamond are a very promising medium for many sensing applications such as magnetometry and thermometry. In this work, we study nanodiamonds deposited from a suspension onto glass substrates. Fluorescence and optically detected magnetic resonance spectra recorded with the dried-out nanodiamond ensembles are presented and a suitable scheme for tracking the magnetic-field value using a continuous...