Wyniki wyszukiwania dla: INDUCED SHEATH VOLTAGE - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: INDUCED SHEATH VOLTAGE

Filtry

wszystkich: 2251
wybranych: 1584

wyczyść wszystkie filtry


Filtry wybranego katalogu

  • Kategoria

  • Rok

  • Opcje

wyczyść Filtry wybranego katalogu niedostępne

Wyniki wyszukiwania dla: INDUCED SHEATH VOLTAGE

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publikacja

    - Rok 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The Impact of Micro-Sources on Voltage Distortions in a Power Grid

    Publikacja

    The increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...

    Pełny tekst do pobrania w portalu

  • Voltage control in a power system with renewable sources of energy

    Publikacja

    - Rok 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fractional-order Systems and Synchronous Generator Voltage Regulator

    Publikacja

    - Acta Energetica - Rok 2015

    Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...

    Pełny tekst do pobrania w portalu

  • DC-link voltage balancing in cascaded H-Bridge converters

    In the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...

    Pełny tekst do pobrania w portalu

  • Classification of high-voltage varistors into groups of differentiated quality

    The research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Low harmonic multipulse voltage converters using coupled reactors

    Publikacja

    - Rok 2016

    This paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Synchronized six-step voltage generation in high-speed PMSM drive

    Publikacja

    Synchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...

    Pełny tekst do pobrania w portalu

  • Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System

    Publikacja

    - Rok 2012

    This paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage Harmonics Measuring Issues in Medium Voltage Systems

    Publikacja

    - Rok 2011

    W rozdziale przedstawiono zagadnienia związane z dokładnością pomiarów zniekształceń harmonicznych napięcia z wykorzystaniem przekładników napięciowych w sieciach średnich napięć.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Quality assessment of low voltage surge arresters

    Users expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...

    Pełny tekst do pobrania w portalu

  • THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS

    Publikacja

    The paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.

  • Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy

    Publikacja

    - Rok 2008

    Resonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage Source Power Line Conditioner for Applications in Local Supply Systems

    Publikacja

    - Rok 2019

    The paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...

    Pełny tekst do pobrania w portalu

  • Modular multipulse voltage source inverters with integrating coupled reactors

    Publikacja

    - Rok 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors

    This paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...

    Pełny tekst do pobrania w portalu

  • Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application

    Publikacja

    - Rok 2019

    The article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...

    Pełny tekst do pobrania w portalu

  • Earthquake-Induced Structural Pounding

    Publikacja

    Earthquake-induced structural pounding between insufficiently separated build-ings, or bridge segments, has been repeatedly observed during ground motions. The reports after earthquakes indicate that it may lead to some local damage in the case of moderate seismic events or may result in considerable destruction or even collapse of colliding structures during severe ground motions. Pounding in build-ings is usually caused by the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Quality assessment of high voltage varistors by third harmonic index

    High voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...

    Pełny tekst do pobrania w portalu

  • A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.

    Publikacja

    In this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...

    Pełny tekst do pobrania w portalu

  • Third harmonic index as a diagnostic tool of high-voltage varistors

    Publikacja

    The recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...

  • Dynamic variables limitation for backstepping control of induction machine and voltage source converter

    Dynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...

    Pełny tekst do pobrania w portalu

  • A low-voltage CMOS negative impedance converter for analogue filtering applications

    Low-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....

    Pełny tekst do pobrania w portalu

  • Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors

    This paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...

    Pełny tekst do pobrania w portalu

  • Design of synchronous generator voltage regulator based on h control theory

    Publikacja

    - Rok 2005

    The power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...

  • Use of AMI Meters in the Process of Low Voltage Grid Optimization

    Publikacja

    - Acta Energetica - Rok 2017

    This is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .

    Pełny tekst do pobrania w portalu

  • Traffic-induced vibrations. The impact on buildings and people

    Publikacja

    Traffic-induced vibrations have recently been of major concern to engineers as one of the aspects of so called physical environmental pollution. The interest is related to the observations of serious negative effects of such kind of vibrations on buildings and their inhabitants. Traffic-induced vibrations may cause plaster cracks, structural damage and even failure and collapse of the structure. They may also be the reason of serious...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Medium-Voltage Drives: Challenges and existing technology

    Publikacja
    • H. Abu-Rub
    • S. Bayhan
    • S. Moinoddin
    • M. Malinowski
    • J. Guziński

    - IEEE Power Eelectronics Magazine - Rok 2016

    The article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...

    Pełny tekst do pobrania w portalu

  • A High-Efficient Low-Voltage Rectifier for CMOS Technology

    A new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...

    Pełny tekst do pobrania w portalu

  • Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter

    Publikacja

    A new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives

    Publikacja

    - Rok 2005

    This paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Exact generation of voltage vector in voltage inverter with pulse width modulation

    W artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The Issues of Reactive Power Compensation in High-voltage Transmission Lines

    This paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.

    Pełny tekst do pobrania w portalu

  • The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables

    Publikacja

    - Bulletin of the Polish Academy of Sciences-Technical Sciences - Rok 2021

    This paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...

    Pełny tekst do pobrania w portalu

  • Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter

    In the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Sensorless induction motor drive with voltage inverter and sine-wave filter

    Publikacja

    - Rok 2013

    This paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids

    This paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.

    Pełny tekst do pobrania w portalu

  • Four level inverter's DC bus voltage balancing with 3-terminal DAB converter

    Publikacja

    - Rok 2016

    —Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention

    Publikacja

    - Rok 2014

    In modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station

    Publikacja

    This paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...

    Pełny tekst do pobrania w portalu

  • Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors

    Publikacja

    - Metrology and Measurement Systems - Rok 2017

    This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...

    Pełny tekst do pobrania w portalu

  • Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response

    Publikacja

    - ENERGIES - Rok 2023

    In this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...

    Pełny tekst do pobrania w portalu

  • Analysis of pressure ratio in the intake in dependence on high-voltage behaviours

    Publikacja

    - Przegląd Elektrotechniczny - Rok 2013

    Power control in spark ignition engines by regulating the intake air is performed. The control unit needs information about the air pressure conditions which then enters the combustion chamber. The information about the intake air pressure is an important quantity for optimal control of combustion mixtures. The paper describes some types of sensors that are used to measure the air intake temperature. Air pressure in the intake...

    Pełny tekst do pobrania w portalu

  • Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection

    This paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Analysis of magnetic disturbances of air platform caused by induced magnetisation

    Publikacja

    - Rok 2009

    Magnetometric systems installed on air platforms like airplanes or helicopters are equipped in compensators of magnetic disturbances. Time changes of the platform's position caused generation of magnetic disturbances. The permanent and induced magnetization of ferromagnetic elements and eddy currents induced in conducting parts of the platform are sources of these disturbances. The linear model of magnetic disturbances of platforms...

  • A new approach to cross-bonding in medium voltage cable lines

    Publikacja

    The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...

    Pełny tekst do pobrania w portalu

  • Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles

    Publikacja

    The current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...

    Pełny tekst do pobrania w portalu

  • Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor

    The article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.

    Pełny tekst do pobrania w portalu

  • Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid

    Publikacja

    Current low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...

    Pełny tekst do pobrania w portalu

  • Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables

    Publikacja
    • M. A. Saleh
    • S. S. Refaat
    • M. Olesz
    • H. Abu-Rub

    - Rok 2021

    This work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...

    Pełny tekst do pobrania w serwisie zewnętrznym