Filtry
wszystkich: 41
wybranych: 38
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: RESPIRATION
-
A body position influence on ECG derived respiration
PublikacjaAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublikacjaRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublikacjaRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublikacjaThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Evaluation of respiration capacity of VF in hybrid constructed wetland systems.
PublikacjaThree VF-beds operating in hybrid constructed wetlands in configuration HF-VF-HF were analysed. These hybrid constructed wetlands provide the II stage biological treatment. They are located in Pommerania voivodship, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.5, 14.2 and 21.6 m3/d, respectively. The article focuses on performance and operation of VF-CW plants during one year. Based on removal of organic matter...
-
Analysis of the parameters of respiration patterns extracted from thermal image sequences
PublikacjaRemote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably...
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublikacjaThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Theophylline Therapy for Near-Fatal Cheyne–Stokes Respiration: A Case Report
Publikacja -
Sport-related concussion alters cerebral hemodynamic activity during controlled respiration
PublikacjaThis study investigated cerebral hemodynamic activity following sport-related concussion. Prefrontal cortex oxygenation was assessed by near-infrared spectroscopy (NIRS) during a controlled breathing protocol. Wavelet transformation of the NIRS signals showed significant decreases in HbO2 and HbD amplitude at the respiratory frequency interval (0.10–0.6 HZ) from preseason baseline to acute concussion. These results suggest a decreased...
-
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublikacjaRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublikacjaA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
Assessment of respiratory responses to emotional virtual reality stimuli with non-contact respiration monitoring system
Publikacja -
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublikacjaGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
Theophylline Therapy for Cheyne-Stokes Respiration During Sleep in a 41-Year-Old Man With Refractory Arterial Hypertension
Publikacja -
Tipping point in plant–fungal interactions under severe drought causes abrupt rise in peatland ecosystem respiration
Publikacja -
Using wearable device for biomedical signal acquisition and processing
PublikacjaIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublikacjaThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublikacjaIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children
PublikacjaIn this article the procedure of selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children is proposed. Authors designed and conducted an experiment in which a group of 30 health volunteers (16 females and 14 males) were examined. Under controlled conditions people were exposed to a stressful situation caused by the picture or sound (1kHz constant sound, which was gradually...
-
System supporting behavioral therapy for children with autism
PublikacjaIn this paper, a system supporting behavioral therapy for autistic children is presented. The system consists of sensors network, base station and a brooch indicating person's emotional states. The system can be used to measure values of physiological parameters that are associated with changes in the emotional state. In the future, it can be useful to inform the autistic child and the therapist about the emotional state of the...
-
HPLC-coupled post-column derivatization aims at characterization and monitoring of plant phytocomplexes, not at assessing their biological properties
PublikacjaTwo recent decades of research identified a number of environmental factors as well as mechanisms leading to pathogenic processes in the human organism. A common factor in pathogenesis of many diseases is oxidative stress, a condition in which the production of damaging reactive oxygen species (ROS), present in the body as an inevitable consequence of respiration and exacerbated by the inflammatory response and by exogenous factors...
-
QRS Morphology-Based EDR Signal—Factors Determining its Properties
PublikacjaRespiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...
-
Self diagnostics using smart glasses - preliminary study
Publikacjan this preliminary study we analyzed the possibility of the reliable measurement of biomedical signals with some potential hardware extensions of smart glasses. Using specially designed experimental prototypes four category of biomedical signals were measured: electrocardiograms, electromyograms, electroencephalograms and respiration waveforms. Experi- ments with volunteers proved that using even simple construc- tion of sensors...
-
Effect of long-term cold storage on physicochemical attributes and bioactive components of kiwi fruit cultivars
PublikacjaVarious kiwi fruit cultivars, bred in Korea, were kept in cold storage for 8–24 weeks for possible increase of their quality. Firmness significantly decreased at initial time in all cultivars.The rate of softeningwas the slowest in “Hayward”, followed by “Hort16A”, “Haenam”, “Daheung”, “Bidan”, “Hwamei”, and “SKK 12”. Sensory value increased with decreasing of firmness. Soluble solids content increased with storage time while acidity gradually...
-
A detector of sleep disorders for using at home
PublikacjaObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...
-
Optimal ECG lead for deriving respiratory signal
PublikacjaEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies
PublikacjaAbstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...
-
Influence of nitrogen and organic matter fractions on wastewater treatment in treatment wetland
PublikacjaMunicipal wastewater contains both biodegradable and non-degradable pollutants. Moreover, they are present in dissolved, colloidal and particulate forms. These fractions are characterised by various decomposition rates, hence their bioavailability during microbial respiration. It was confirm that biological degradation rate in terms of COD reduction is influenced by particle size speciation. Therefore, the objective of the study...
-
Open smart glasses development platform for AAL applications
PublikacjaThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
-
T cell Activation Is Driven by an ADP-Dependent Glukosinase Linking Enhanced Glycolysis with Mitochondrial Reactive Oxygen Species Generation
PublikacjaMitochondria-originating reactive oxygen species control T cell receptor (TCR)-induced gene expression. Here, we show that TCR-triggered activation of ADP-dependent glucokinase (ADPGK), an alternative, glycolytic enzyme typical for Archaea, mediates generation of the oxidative signal. We also show that ADPGK is localized in the endoplasmic reticulum and suggest that its active site protrudes toward the cytosol. The ADPGK-driven...
-
Wavelet-based denoising method for real phonocardiography signal recorded by mobile devices in noisy environment
PublikacjaThe main obstacle in development of intelligent autodiagnosis medical systems based on the analysis of phonocardiography (PCG) signals is noise. The noise can be caused by digestive and respiration sounds, movements or even signals from the surrounding environment and it is characterized by wide frequency and intensity spectrum. This spectrum overlaps the heart tones spectrum, which makes the problem of PCG signal filtrating complex....
-
Determination of cyanide ion in urine samples using ion chromatography with pulsed amperometric detection.
PublikacjaCyanides are widely applied in industrial activity, including gold and silver mining and the production of organic chemicals. HCN is also formed directly from fossil fuel combustion sources from gasoline and diesel vehicles. In natural environment, in plants seeds for example an apple seed, it exists as a cyanogenic glycosides. The amount of cyanide ions originating from food products is however rather small. Larger concentrations...
-
Endothelial Dysfunction Driven by Hypoxia—The Influence of Oxygen Deficiency on NO Bioavailability
PublikacjaCardiovascular diseases (CVDs) are the leading cause of death worldwide. The initial stage of CVDs is characterized by endothelial dysfunction, defined as the limited bioavailability of nitric oxide (NO). Thus, any factors that interfere with the synthesis or metabolism of NO in endothelial cells are involved in CVD pathogenesis. It is well established that hypoxia is both the triggering factor as well as the accompanying factor...
-
Mining Knowledge of Respiratory Rate Quantification and Abnormal Pattern Prediction
PublikacjaThe described application of granular computing is motivated because cardiovascular disease (CVD) remains a major killer globally. There is increasing evidence that abnormal respiratory patterns might contribute to the development and progression of CVD. Consequently, a method that would support a physician in respiratory pattern evaluation should be developed. Group decision-making, tri-way reasoning, and rough set–based analysis...
-
Real-time facial feature tracking in poor quality thermal imagery
PublikacjaRecently, facial feature tracking systems have become more and more popular because of many possible use cases. Especially in medical applications location of the face and facial features are very useful. Many researches have presented methods to detect and track facial features in visible light. However, facial feature analysis in thermography may also be very advantageous. Some examples of using infrared imagery in medicine include...
-
Respiratory Rate Estimation Based on Detected Mask Area in Thermal Images
PublikacjaThe popularity of non-contact methods of measuring vital signs, particularly respiratory rate, has increased during the SARS-COV-2 pandemic. Breathing parameters can be estimated by analysis of temperature changes observed in thermal images of nostrils or mouth regions. However, wearing virus-protection face masks prevents direct detection of such face regions. In this work, we propose to use an automatic mask detection approach...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublikacjaBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
Composition and antimicrobial activity of fatty acids detected in the hygroscopic secretion collected from the secretory setae of larvae of the biting midge Forcipomyia nigra (Diptera: Ceratopogonidae)
PublikacjaThe hygroscopic secretion produced by the secretory setae of terrestrial larvae of the biting midge Forcipomyia nigra (Winnertz) was analysed using gas chromatography coupled with mass spectrometry (GC-MS). The viscous secretion is stored at the top of each seta and absorbs water from moist air. GC-MS analyses (four independent tests) showed that the secretion contained 12 free fatty acids, the most abundant of which were oleic...