Filtry
wszystkich: 1229
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MRI IMAGES BINARIZATION
-
Luminescence properties of Eu3+ and Tb3+ doped silica-based xerogels
PublikacjaPure SiO2 xerogels and SiO2 xerogels containing SrF2: Eu3+/: Tb3+ crystals were prepared using sol-gel method. Luminescent spectra showed excitation and emission peaks characteristic to Eu3+ and Tb3+ 4f - 4f transitions. ET Tb3+→Eu3+ has been observed. XRD pattern of SiO2 matrix confirmed lack of long range order. Patterns of SiO2-SrF2:Eu3+ and SiO2-SrF2:Tb3+ showed peaks corresponding to SrF2. SEM images have shown agglomerates...
-
Adaptive Method of Adjusting Flowgraph for Route Reconstruction in Video Surveillance Systems
PublikacjaPawlak’s flowgraph has been applied as a suitable data structure for description and anal- ysis of human behaviour in the area supervised with multicamera video surveillance system. Infor- mation contained in the flowgraph can be easily used to predict consecutive movements of a partic- ular object. Moreover, utilization of the flowgraph can support reconstructing object route from the past video images. However, such a flowgraph with...
-
The study of structure and surface morphology of lithium titanate sol-gel derived thin films
PublikacjaIn this paper the structure and the surface morphology of lithium titanate (LTO) thin films are presented. Nanocrystalline thin films were prepared by sol–gel method. To examine the influence of the annealing time on as-prepared films crystallization, the coatings were heated at different temperatures in the range of 500 °C–600 °C for 10, 20, 40 and 80 h. The structure of the obtained material was investigated using the X-ray diffraction...
-
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
An Overview of Image Analysis Techniques in Endoscopic Bleeding Detection
PublikacjaAuthors review the existing bleeding detection methods focusing their attention on the image processing techniques utilised in the algorithms. In the article, 18 methods were analysed and their functional components were identified. The authors proposed six different groups, to which algorithms’ components were assigned: colour techniques, reflecting features of pixels as individual values, texture techniques, considering spatial...
-
An Analysis of Uncertainty and Robustness of Waterjet Machine Positioning Vision System
PublikacjaThe paper presents a new Automatic Waterjet Positioning Vision System (AWPVS) and investigates components of workpiece positioning accuracy. The main purpose of AWPVS is to precisely identify the position and rotation of a workpiece placed on a waterjet machine table. Two webcams form a basis for the system, and constitute its characteristics. The proposed algorithm comprises various image processing techniques to assure a required...
-
Innovative Solutions for Immersive 3D Visualization Laboratory
PublikacjaThe paper presents results of the work concerning the technical specification of Immersive 3D Visualization Laboratory to be opened in late summer 2014 at the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology in Poland. The person immersed in VR space will be placed in a transparent sphere with a diameter of over 10 feet, supported on rollers and equipped with a motion tracking system....
-
Visual Object Tracking System Employing Fixed and PTZ Cameras
PublikacjaThe paper presents a video monitoring system utilizing fixed and PTZ cameras for tracking of moving objects. First type of camera provides image for background modelling, being employed for foreground objects localization. Estimated objects locations are then utilised for steering of PTZ cameras when observing targeted objects with high close-ups. Objects are classified into several classes, then basic event detection is being...
-
Gesture-based computer control system applied to the interactive whiteboard
PublikacjaIn the paper the gesture-based computer control system coupled with the dedicated touchless interactive whiteboard is presented. The system engineered enables a user to control any top-most computer application by using one or both hands gestures. First, a review of gesture recognition applications with a focus on methods and algorithms applied is given. Hardware and software solution of the system consisting of a PC, camera, multimedia...
-
Gesture-based computer control system applied to the interactive whiteboard
PublikacjaIn the paper the gesture-based computer control system coupled with the dedicated touchless interactive whiteboard is presented. The system engineered enables a user to control any top-most computer application by using one or both hands gestures. First, a review of gesture recognition applications with a focus on methods and algorithms applied is given. Hardware and software solution of the system consisting of a PC, camera, multimedia...
-
Using the ultrasonic tomography method to study the condition of wooden beams from historical buildngs
PublikacjaThe need to evaluate the integrity of wooden structural elements is constantly increasing. Non-destructive methods are becoming more popular in this field of research. One type of non-destructive testing is the ultrasonic imaging method, which allows the analysis of internal wood structures without disturbing their state and integrity. In this study, we are interested in assessing the effect of wood condition on the ultrasound...
-
Cross-sectional imaging of materials structure using PS-OCT
PublikacjaOptical low-coherence tomography is a measurement technique for non-contact and non-destructive investigation of materials inner structure. Nowadays, this method is highly applied in medical treatment especially in dermatology and ophthalmology. During our research we have developed an optical low-coherence tomography system with polarization state analysis for structure examination of a broad range of technical materials. In this...
-
Imaging polarimeter with high-accuracy measuring principles in crystal optics
PublikacjaAn imaging polarimeter based on the principles of high-accuracy polarimetry well known in crystal optics is proposed. The application of scientific digital cameras for performance light measurements leads to precise data on polarizers quality, i.e., maps of extinction ratio and transmission axis. Processing of numerous images, acquired at various settings in the polarizer-sample-analyser system, allows to determine the two-dimensional...
-
Multi-Camera Vehicle Tracking Using Local Image Features and Neural Networks
PublikacjaA method for tracking moving objects crossing fields of view of multiple cameras is presented. The algorithm utilizes Artificial Neural Networks (ANNs). Each ANN is trained to recognize images of one moving object acquired by a single camera. Local image features calculated in the vicinity of automatically detected interest points are used as object image parameters. Next, ANNs are employed to identify the same objects captured...
-
Synthesis of reduced graphene oxide nanosheets using nanofibers from methane and biogas thermal decomposition with various catalysts
PublikacjaReduced graphene oxide and graphene oxide (rGO, GO) were synthesised from carbon nanofibers, which were formed in catalytic thermal decomposition of methane (CDM) and biogas with different catalysts used in the process. The aim of the work was valorization of CDM carbon nanofiber products. The samples were characterized using Raman spectra, a scanning electron microscope and a transmission electron microscope. As a result, we observe...
-
Variable length sliding models for banking clients face biometry
PublikacjaAn experiment was organized in 100 bank branches to acquire biometric samples from nearly 5000 clients including face images. A procedure for creating face verification models based on continuously expanding database of biometric samples is proposed, implemented, and tested. The presented model applies to circumstances where it is possible to collect and to take into account new biometric samples after each positive verification...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublikacjaThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
Analysis of luminance distribution uniformity in CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centers in the world developed a virtual reality systems or laboratories. The effect of user “immersion” into virtual reality in such systems is largely dependent of optical properties of the system. In this paper, problems of luminance distribution uniformity in CAVE-type virtual reality systems are analyzed. For better characterization of CAVE luminance nonuniformity corner and...
-
MSIS sonar image segmentation method based on underwater viewshed analysis and high-density seabed model
PublikacjaHigh resolution images of Mechanically Scanned Imaging Sonars can bring detailed representation of underwater area if favorable conditions for acoustic signal to propagate are provided. However to properly asses underwater situation based solely on such data can be challenging for less than proficient interpreter. In this paper we propose a method to enhance interpretative potential of MSIS image by dividing it in to subareas depending...
-
Influence of Aggregating Window Size on Disparity Maps Obtained from Equal Baseline Multiple Camera Set (EBMCS)
PublikacjaThis paper is concerned with obtaining disparity maps on the basis of images from Equal Baseline Multiple Camera Set (EBMCS). EBMCS consists of a central camera and side cameras. Algorithms for obtaining disparity maps with the use of EBMCS take advantage of aggregating windows similarly to stereo matching algorithms for a stereo camera, a camera matrix or a camera array. The paper analyzes the influence of aggregating window size...
-
Intelligent system supporting diagnosis of malignant melanoma
PublikacjaMalignant melanomas are the most deadly type of skin cancers. Early diagnosis is a key for successful treatment and survival. The paper presents the system for supporting the process of diagnosis of skin lesions in order to detect a malignant melanoma. The paper describes the development process of an intel-ligent system purposed for the diagnosis of malignant melanoma. Presented sys-tem can be used as a decision support system...
-
Invasive breast carcinoma of no special type - Female, 73 - Tissue image [5040730020271441]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 72 - Tissue image [5040730020271421]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 72 - Tissue image [504073002027301]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 72 - Tissue image [3300730069427661]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 72 - Tissue image [5040730020274821]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
ZARZĄDZANIE PROCESEM INWESTYCYJNYM PODCZAS REALIZACJI PRACOWNI RADIOLOGICZNYCH Z WYKORZYSTANIEM ŚRODKÓW PUBLICZNYCH
Publikacjawidzenia zagadnień funkcjonalnych, ekonomicznych, epidemicznych, jak również dobra społecznego. Pracownie radiologiczne stanowią współcześnie część placówek medycz- nych (ambulatoriów i szpitali), które wykorzystują je zarówno przy diagnostyce, jak i terapii różnych schorzeń. Prawidłowe zarządzanie procesem inwestycyjnym dla takich przedsięwzięć jest zadaniem wieloaspektowym i skomplikowanym. Podejmowane dzia- łania powinny być...
-
John B World Journal of Case Reports and Clinical Images
Osoby -
The AFM micrographs of vanadium oxides thin films obtained at 800°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on a silicon substrate and vanadium thin films were obtained by annealing as-prepared films at...
-
Rozpoznawanie oraz lokalizacja w obrazie przewodów linii wysokiego napięcia
PublikacjaW pracy przedstawiono opracowany algorytm rozpoznawania oraz lokalizacji przewodów linii wysokiego napięcia na podstawie obrazu horyzontalnego. Procedura detekcji przewodu została podzielona na trzy etapy. Pierwszy etap zawiera algorytm wykrywania krawędzi wykazujący największą czułość na krawędzie poziome, a jednocześnie brak czułości na krawędzie pionowe. Efektem jest znaczna redukcja liczby wykrytych krawędzi w porównaniu do...
-
Imaging of biological samples: crassula arborescens
Dane BadawczeOne of the tasks of modern botany is to describe the relationship between climatic conditions and other environmental factors and the anatomical structure and adaptation of species present in given geographic areas. The work [1] focuses on anatomical and morphological studies of leaves of plants from the coarse family. Species tested belong to leaf...
-
Analysis of induction of DNA DSBs on telomeres in A549 cells
Dane BadawczeData consist of an analysis of DNA DSBs on telomeres. A549 were treated with compounds (TXT4, MTX, DMSO) at IC90 concentration for the indicated time. Images were acquired with an LSM 800 inverted laser scanning confocal microscope (Carl Zeiss; Dresden, Germany) equipped with an Airyscan detector using a ×63 1.4 NA Plan Apochromat objective (Carl Zeiss)....
-
Monthly mean concentration of chlorophyll a on the sea surface of the Baltic Sea
Dane BadawczeMonthly mean surface concentration of chlorophyll a in the years 2003-2022 calculated on the basis of data from the SatBaltic System (https://satbaltyk.iopan.gda.pl/). Maps of monthly average values with a resolution of 1 km were derived from daily satellite data from the Moderate Resolution Imaging Spectroradiometer (MODIS). Gaps in satellite images...
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d powder aglomerate
Dane BadawczeThis dataset contains image of the SrTi0.50Fe0.50O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
The AFM micrographs of vanadium oxides thin films obtained at 1200°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
SEM image and EDS map of SrTi0.65Fe0.35O3-d powder aglomerate
Dane BadawczeThis dataset contains image of the SrTi0.65Fe0.35O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
The AFM micrographs of vanadium oxides thin films obtained at 400°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of vanadium oxides thin films obtained at 600°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of of vanadium oxides thin films obtained at 300°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of vanadium oxide thin films obtained at 100°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of vanadium oxides thin films obtained at 150°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
SEM image and EDS map of SrTi0.30Fe0.70O3-d powder aglomerate
Dane BadawczeThis dataset contains image of the SrTi0.30Fe0.70O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
The AFM micrographs of vanadium oxides thin films obtained at 200°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of vanadium oxides thin films deposited on quartz glass - the influence of the thickness of the thin film on its morphology
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The thin films with different thicknesses (1, 2 or 3 AsP layers) were deposited on a quartz glass substrate and were...
-
The AFM micrographs of vanadium oxides thin films obtained at 450°C
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The sol was deposited on quartz glass and silicon substrate and vanadium thin films were obtained by annealing as-prepared...
-
The AFM micrographs of vanadium oxides thin films deposited on silicon - the influence of the thickness of the film on morphology
Dane BadawczeThe DataSet contains the atomic force microscope images of the surface of vanadium oxide thin films. The thin films were obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The thin films with different thicknesses (1, 2 or 3 AsP layers) were deposited on a silicon substrate and were annealing...
-
Stochastic intervals for the family of quadratic maps
Dane BadawczeNumerical analysis of chaotic dynamics is a challenging task. The one-parameter families of logistic maps and closely related quadratic maps f_a(x)=a-x^2 are well-known examples of such dynamical systems. Determining parameter values that yield stochastic-like dynamics is especially difficult, because although this set has positive Lebesgue measure,...
-
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Dane BadawczeThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
Modelling of acoustic backscattering by southern Baltic herring
PublikacjaAssessment of Baltic herring abundance can be carried out using acoustic techniques. Analysis of the relationship between the Baltic herring individual target strength, TS, and the total fish length, L, important for the acoustic assessment, showed the relationship to be dependent on the location of the study area. This finding motivated a detailed analysis of the relationship for the herring occurring in the southern Baltic...
-
Histogram of Gradients with Cell Average Intensity for Human Detection
PublikacjaThe modification of the descriptor in human detector using Histogram of Oriented Gradients and support vector machine is presented. The proposed modification requires inserting the average cell intensitiesresulting with the increase of the length of the descriptor from 3780 to 4200 values, but it is easy to compute and instantly gives 14-26% of miss rate improvement at 10^-4 False Positives Per Window (FPPW). The modification...