Wyniki wyszukiwania dla: AIR QUALITY
-
Data on bicycle traffic in Lodz (Poland) paired with weather and air quality data
Dane BadawczeThe file contains data on bicycle traffic registered by counting stations loacted in Lodz in the years 2016-2019. The data are paired with weather and air quality data from Lodz collected for the same period. The data is described below:
-
Zastosowanie techniki dozymetrii pasywnej do oceny jakości powietrza wewnętrznego. Application of passive sampling technique for assessment of indoor air quality
PublikacjaJakość powietrza wewnętrznego jest istotnym parametrem wpływającym na dobre samopoczucie i zdrowie człowieka. Kluczowego znaczenia nabiera więc jego nieustanna kontrola i oznaczanie zawartości zanieczyszczeń, które występują w nim na bardzo niskich poziomach stężeń. Do pomiarów jakości powietrza wewnętrznego często wykorzystywana jest (znana od ponad pół wieku) technika dozymetrii pasywnej. W literaturze nadal pojawiają się doniesienia...
-
<p>Potential effects of microbial air quality on the number of new cases of diabetes type 1 in children in two regions of Poland: a pilot study</p>
Publikacja -
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Evaluation of Ambient Air Odour Quality in Vicinity of Municipal Landfill Using Electronic Nose Technique
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of municipal landfill. The investigation was carried out with a prototype of electronic nose and a team of panelists utilizing the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. Performed measurements...
-
The Quality of Air in Polish Health Resorts with an Emphasis on Health on the Effects of Benzo(a)pyrene in 2015–2019
Publikacja -
Results from a collective bound case studies analysis of researched Pol‐ ish metropolises for inspecting information management regarding air quality in light of information ecology
Publikacja -
Ocena jakości powietrza atmosferycznego na terenie Aglomeracji Trojmiejskiej = Quality of atmospheric air in the Tricity area
PublikacjaNa terenie Aglomeracji Trójmiejskiej i Tczewa monitoring jakości powietrza prowadzony jest, obok jednostek samorządowych przez fundację: Agencja Monitoringu Regionalnego Atmosfery Aglomeracji Gdańskiej - ARMAAG. Katedra Chemii Analitycznej PG współpracując z fundacją ARMAAG podjęła próbę uzupełnienia informacji na temat stanu atmosfery na terenie Trójmiasta i Tczewa o ocenę pod względem zawartości analitów z grupy BTEX. Celem...
-
Transformation of the countryside into an open-air museum as a way to rescue its spatial layot and to improve the quality of life
Publikacja -
Zastosowanie analizy szeregów czasowych do oceny zanieczyszczenia powietrza atmosferycznego w rejonie Trójmiasta. Application of time series analysis on air quality assessment in the region of Tricity
PublikacjaNa podstawie analizy wyników pomiarów poziomów stężenia: NO3-, SO42-, F- ,Cl-, NH4+, PO43-, Ca2+, K+, Mg2+ oraz pomiarów pH i przewodności elektrolitycznej próbek wód opadowych na terenie Trójmiasta z zastosowaniem techniki analizy szeregów czasowych wykazano, że cykliczne wahania poziomów depozycji SO42-, F-, NO3- i Ca2+ w próbkach są skorelowane z cyklicznymi 9 zmianami przeważających kierunków wiatrów. Analiza struktury szeregów...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublikacjaThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
BTEX concentration levels in urban air in the area of the Tri-City agglomeration (Gdansk, Gdynia, Sopot), Poland
PublikacjaThe paper presents and discusses the results of atmospheric air quality research conducted in 2012 with reference to the level of BTEX compounds in the Tri-City agglomeration—Gdansk, Gdynia, and Sopot (northern Poland). At the stage of BTEX sampling from the ambient air, Radiello® diffusive passive samplers were applied. The annual time-weighted average concentrations for benzene, toluene, ethylbenzene, and xylenes (BTEX) in the...
-
Transformation of the countryside into an open-air museum as a way to rescure its spatial layout and to improve the quality of live = Przekształcenie wsi w muzeum na wolnym powietrzu jako sposób ratowania jej układu przestrzennego i poprawy jakości życia mieszkańców
PublikacjaSince the first open-air museums until today, the exposition subject-matter has been specialized (ethnographic, archeological, industrial and technical skansens). But idea of the existence of such objects remains unchanged. Still, the goal is to show the collection of wooden buildings in the environment as close to their origin as possible or in the home environment. These distinguish the skansens and make them different then municipal...
-
Conception of interactive information and decision support system for urban and industrial air management
PublikacjaThis article presents the conception of interactive system for air quality management.
-
Air Pollution: Monitoring
PublikacjaThe entry presents an overview of the issues in the field of air pollution monitoring. At the beginning, the general objectives of air monitoring, ambient air quality standards for so-called criteria pollutants, and their sources are discussed. In the next part, both analytical methods and instruments for monitoring of ambient air and stack gases are briefly presented. Additionally, other approaches used in air pollution monitoring,...
-
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublikacjaPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Mobile Systems (Portable, Handheld, Transportable) for Monitoring Air Pollution
PublikacjaThe monitoring and analysis of atmospheric air pollutants is a rapidly developing branch of analytical chemistry. The in situ analysis of atmospheric air quality using mobile instrumentation is becoming routine. The article provides information on devices used in various kinds of mobile laboratories. It reviews the portable gas chromatographs and handheld devices used for detecting and determining specific harmful substances in...
-
Remote Monitoring of Environmental Pollutants
PublikacjaAtmospheric air quality is one of the key factors influencing human health. Air quality evaluation is not an easy task as the atmosphere is a complex system subjected to continuous changes in time. Observed progress in the development of measurement devices and technologies is fundamental for acquisition of more reliable information about condition and quality of atmospheric air. Unfortunately, this process leads to an increase...
-
Evaluation of the Commercial Electrochemical Gas Sensors for the Monitoring of CO in Ambient Air
PublikacjaAir pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used....
-
Jacek Namieśnik prof. dr hab. inż.
OsobyUrodził się 10 grudnia 1949 r. w Mogilnie, zmarł 14 kwietnia 2019 r. w Gdańsku – polski chemik, profesor nauk chemicznych, specjalizujący się w chemii analitycznej i środowiskowej. Rektor Politechniki Gdańskiej w latach 2016–2019. Studia wyższe ukończył w 1972 r. na Wydziale Chemicznym Politechniki Gdańskiej, uzyskując tytuł magistra inżyniera chemika. W 1972 r. rozpoczął pracę na Politechnice Gdańskiej, gdzie w 1978 r. obronił...
-
Chapter 8 – Active Sampling of Air
PublikacjaThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublikacjaThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
PublikacjaAdults spend most of their time in enclosed spaces (e.g., apartment, office and public buildings). According to research conducted by scientists, air quality indoors is much worse than the ambient air quality outdoors. Hazardous chemicals found in air indoors can adversely affect the functioning of the human body and cause many respiratory and circulatory diseases. Harmful chemical compounds (mainly volatile organic compounds and...
-
The Relationships Between BTEX, NOx, and O3 Concentrations in Urban Air in Gdansk and Gdynia, Poland
PublikacjaThis paper presents the results of atmospheric air quality research conducted in the areas of two shipyard cities: Gdansk and Gdynia (Poland), in the period between March and December 2011. The purpose of the research was focused on determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) compounds in atmospheric air. Passive sampling technique, with Radiello® diffusive passive samplers, was used for BTEX sample collection...
-
Anna Zielińska-Jurek prof. dr hab. inż.
OsobyResearch work on photocatalysis by Prof. Anna Zielinska-Jurek started in 2006 at Gdansk University of Technology (Poland), including 3-month research stay at Hokkaido University, Training School “Environmental Applications of TiO2 Photocatalysis” at the University of Oulu in Finland granted by COST Program and Training School “NanoBiophotonics” at the Beckmann Institute, Urbana-Champaign in the USA granted by University of Illinois....
-
Modelling Coarse Particulate Matter PM10 Concentration in the Tricity Area Using GIS
PublikacjaEnvironmental pollution is an issue of global concern, with Particulate Matter (PM) poisoning being a prime cause of lung cancer. This has led the European Commission to establish strict daily and annual PM concentration limits. The monitoring of air quality in major cities is the responsibility of European Member States. The Tricity, a 414.81 km 2 area in northern Poland, is monitored by a network of only 9 stations operated by...
-
Measurement of benzene concentration in urban air using passive sampling
PublikacjaAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Evaluation of the Electronic Nose Used for Monitoring Environmental Pollution
PublikacjaAir pollution is a one of the major concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. Electronic-nose systems based on sensors are an interesting and promising technology in...
-
The effect of anthropogenic activity on BTEX, NO2, SO2, and CO concentrations in urban air of the spa city of Sopot and medium-industrialized city of Tczew located in North Poland
PublikacjaThe major goal of the present study is to compare the air quality of two urban locations situated in Northern Poland – the spa City of Sopot and the medium-industrialized city of Tczew using chemometric methods. As a criterion for the assessment of atmospheric air quality, measurements of benzene, toluene, ethylbenzene and total xylenes were used (collected from atmospheric air using diffusion-type passive samplers) as well as...
-
The environmental dimension of city dwellers’ quality of life and the city’s social and spatial variability
PublikacjaThe purpose of this paper is to attempt an analysis of the environmental dimension of the quality of life using quantitative surveys conducted among residents of Gdańsk. In the paper, we make reference to the theoretical assumptions ensuing from the concept of a comprehensive and integrated approach to the development of the urban environment, whilst noting the profound impact humans bring to their evaluation of the environmental...
-
THE INFLUENCE OF THE URBAN DESIGN ON THE AIR EXCHANGE IN CITIES. SELECTED PROBLEMS IN POLISH REALITY
PublikacjaThe progress of the architecture and urbanism raises problems requiring interdisciplinary research conducted with the use of advanced experimental techniques and computer simulation. The fields of this research include aerodynamics, especially in intensively developed area of Environmental Wind Engineering (EWE). Aerodynamic phenomena occurring around buildings have a significant impact on the quality of the climate in the cities....
-
Analysis the Parameters of the Adaptive Controller for Quality Control of Dissolved Oxygen Concentration
PublikacjaThe wastewater treatment plant can be considered a dynamic large scale complex system, in which the most important control parameter is the dissolved oxygen concentration in the aerobic zone. The air is supplied to this zone by the aeration system. In the paper, both the sequencing batch reactor and the aeration system are modelled and used as plant of control performed by the cascade nonlinear adaptive control system extended...
-
Relevance of the EU Structural Funds’ Allocation to the Needs of Combating Air Pollution in Poland. Analysis of the Operational Programmes of Regions Threatened With Critical Air Pollution from Distributed Energy Sources
PublikacjaRecent years, the European Environmental Agency, has been reporting air quality parameters in Poland, as the poorest among all the EU countries. Despite of adoption of the EU legislation on energy efficiency and energy performance of buildings, existing legal solutions occur insufficient in reducing air pollution in Polish regions. Lack of an effective schemes supporting complex thermal renovation of buildings, exchange of inefficient...
-
Assessment and Optimization of Air Monitoring Network for Smart Cities with Multicriteria Decision Analysis
PublikacjaEnvironmental monitoring networks need to be designed in efficient way, to minimize costs and maximize the information granted by their operation. Gathering data from monitoring stations is also the essence of Smart Cities. Agency of Regional Air Quality Monitoring in the Gdańsk Metropolitan Area (pol. ARMAAG) was assessed in terms of its efficiency to obtain variety of information. The results on one-month average concentrations...
-
Ochrona powietrza - europejskie standardy
PublikacjaCurrent regulations in EU oblige every member country to cover the protection of the air as well as determine, in a bright and clear way, the responsibilities of the governments to monitor the condition and introduce ways of protection of the air from pollution. If the responsibilities imposed by the directive on evaluation and management of the air quality are obeyed by the respective organs of member countries of EU, then the...
-
Rain Gardens SW quality dataset
Dane BadawczeThis dataset contains the results of parameters of storm water runoff and storm water quality in rain garden units. Samples were collected from 4 different rain gardens in Gdansk, Poland.
-
Sick building syndrome due to molds
PublikacjaThe term Sick Building Syndrome (SBS) is a combination of ailments occurring in a specific building. Building occupants complain of symptoms such as headaches and dizziness, fainting, nausea, irritation of the mucosal membranes, skin irritation and other nonspecific hypersensitivity reactions.One of the SBS causes can be molds, which are ubiquitous in the air (over 400 species). It is estimated that 30% of the health problems (related...
-
Enhanced Visible Light Active WO3 Thin Films Toward Air Purification: Effect of the Synthesis Conditions
PublikacjaTaking into consideration, our current environmental situation in the world people should face with growing problem of air and water pollution. Heterogeneous photocatalysis is highly promising tool to improve both, air and water quality through decomposition/mineralization of contaminations directly into harmless CO2 and H2O under ambient conditions. In this contribution we focused on the synthesis of self-assembly WO3 thin films...
-
Hanna Gaweł
OsobyHanna Gawel is a Doctoral Student of the Doctoral School in the Social Sciences in the discipline of Social Communication and Media at Jagiellonian University. Hanna’s research focuses on knowledge, information management and the influence of well-served information in different formats on society. She is currently writing a PhD thesis about how information pollutants affect information regarding air quality in Polish metropolises....
-
Characterizing surface and air temperature in the Baltic Sea coastal area using remote sensing techniques and GIS
PublikacjaEstimation of surface temperature using multispectral imagery retrieved from satellite sensors constitutes several problems in terms of accuracy, accessibility, quality and evaluation. In order to obtain accurate results, currently utilized methods rely on removing atmospheric fluctuations in separate spectral windows, applying atmospheric corrections or utilizing additional information related to atmosphere or surface characteristics...
-
Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques
PublikacjaOdors emitted from municipal wastewater treatment plants belong to a group of pollutants, which is the main cause of people complaining about atmospheric air quality. The limitation of emissions of unpleasant odors generated by wastewater treatment plants by using appropriate deodorization methods is omitted on numerous occasions. This can have a negative inflence on public trust and the quality of atmospheric air. The article...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublikacjaThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Conception of interactive information and decision support system - model and evaluation
PublikacjaThis article presents conception of interactive information and decision support system for urban and industrial air quality management. The emphasis of the project is on real-time analysis and multi-media information, and support of distributed and mobile clients through the Internet.
-
Assessment of the activities of private universities in the context of quality management in 2010
Dane BadawczeIn all universities, the assessment of the quality is made by the supervisor, the opinion of students and the admission of classes have the greatest impact on the assessment of the quality of education. Subsequent tracking of the student's fate has a slightly smaller impact on the grade. Research also shows that only 4 out of 7 respondents monitor the...
-
The Influence of Stretch Rod Speed on the Relationship between Preblown Bottle Aesthetic Quality and Final Blown Bottle Thickness Profile in Stretch Blow Molding from Preform Process
PublikacjaFrom a mechanical point of view, the aesthetic quality of preblown PET bottles and thickness profile of final blown PET bottles manufactured in ISBM process are determined by mechanical and thermal response of blown preforms. From the microscopic point of view the biggest influence on the mechanical and thermal properties of PET bottles have orientation and crystallization processes. From a technological point of view, the aesthetic...
-
Selectivity of amperometric gas sensors in multicomponent gas mixtures
PublikacjaIn recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublikacjaThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Dane BadawczeThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...