Wyniki wyszukiwania dla: POWER MEASUREMENT
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Energy consumption estimation of low-power devices using an integrating coulombmeter
PublikacjaThe main problem in designing devices powered with Energy Harvesting is an estimation of energy demand of low-power devices as well as quantity of energy provided by the selected energy transducer in the assumed work conditions. Due to the work characteristic of each block of the device and properties of the measured signal, measurement is not trivial. The paper presents the proposal of the micro-charge measurement device based...
-
Measurements of the fundamental harmonic frequency of voltages on main bars in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the fundamental...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Measurements of the rms currents in two phases in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
Measurements of the rms voltages on main bars in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
Grzegorz Lentka dr hab. inż.
OsobyGrzegorz Lentka uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie systemów pomiarowych. Stopień doktora nauk technicznych uzyskał w roku 2003, a doktora habilitowanego w 2014. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku profesora PG. W ramach prowadzonej dydaktyki zajmuje się zagadnieniami związanymi z interfejsami...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
Measurements of the coefficients of current distribution between two generators operating in parallel in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the coefficients...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/ Analyser (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The instrument performs a set of measurement functions that...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublikacjaThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
Steady-State Vibration Level Measurement of the Five-Phase Induction Machine during Third Harmonic Injection or Open-Phase Faults
PublikacjaMultiphase electric machines are increasingly used in various industries and for electromobility. Complex systems have been developed for the control and powering of multiphase machines, which require verification. The quality of control and the power supply of electric machines is usually evaluated by analyzing various electrical parameters. On the other hand, taking into account the fact that a motor is an electrical-mechanical...
-
Piotr Chrzan prof. dr hab. inż.
OsobyUrodził się w 1954 r. w Sopocie. Jest absolwentem Wydziału Elektroniki Politechniki Gdańskiej (1978). W 1980 r. podjął pracę na Wydziale Elektrycznym w zespole prof. Jerzego Jaczewskiego. W 1988 r. uzyskał stopień naukowy doktora nauk technicznych, habilitację w 1999 r., w zakresie elektrotechniki: energoelektroniki i automatyki napędu, a tytuł profesora w 2017 r. Był promotorem 6 obronionych prac doktorskich (w tym 3 z wyróżnieniem)....
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Revisiting the Measurement of Anomie
Publikacja -
MEASUREMENT OF NOISE IN SUPERCAPACITORS
PublikacjaA developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublikacjaThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Low-Power WSN System for Honey Bee Monitoring
PublikacjaThe paper presents a universal low-power system for biosensory data acquisition in scope of bees monitoring. We describe the architecture of the system, energy-saving components as well as we discuss the selection of used sensors. The work focuses on energy optimization in a scope of wireless communication. A custom protocol was implemented, which is the basis for presented energy-efficient devices. Data exchange process during...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
Comparative Analysis of Salient and Non-Salient Pole Brushless Synchronous Generator for Application in Autonomous Electric Power System
PublikacjaThis paper presents a comparative study of two types of brushless synchronous generator for application in autonomous electric power systems (e.g. airplane power grid). Commercially used salient pole and a prototype non-salient pole high speed multi-pole brushless synchronous generator (BSG) have been presented. Comparative analysis of both types of the generator has been performed. Chosen simulation (using FEM and circuit models)...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublikacjaModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
A method of two-terminal excess noise measurement with a reduction of measurement system and contact noise
PublikacjaPrzedstawiono metodę i system do pomiaru szumów nadmiarowych dwójników elektrycznych ze znaczną redukcją wpływu szumów własnych systemu pomiarowego i szumów kontaków. Proponowana metoda może byc zastosowana do pomiaru szumów elementów z wyprowadzonymi końcówkami, bądź też struktur, gdy jako wzorcowy szum odniesienia może zostać zastosowany szum struktury rezystywnej wytworzonej bezpośrednio na strukturze w otoczeniu elementu testowanego.
-
The concept of a new two-stage fuse for high power pulse forming
PublikacjaThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
Spikes removal in surface measurement
Publikacja -
The prototype of a wireless measurement card
Publikacja -
Air Pollutant Emission Measurement
Publikacja -
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublikacjaAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublikacjaThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
The power spectral density of audible noise and electric disturbances in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
EMI mitigation of GaN power inverter leg by local shielding techniques
PublikacjaThis paper presents local shielding techniques applied to a half-bridge inverter leg with the aim to reduce the common mode (CM) current noise at converter’s DC input. The research study is conducted for 650V Enhancement mode Gallium Nitride (GaN) power transistor switches. Main contributors of parasitic capacitances referred to the inverter-leg middle point node are identified. Then, shielding solutions are proposed to reduce...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublikacjaTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublikacjaAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Four-state measurement method for direct-reading noise figure measurement of low-gain two-ports.
PublikacjaOmówiono problemy techniczne pomiaru współczynnika szumu dwuwrotników o małym wzmocnieniu mocy dysponowanej realizowanych przy stosowaniu znanych metod pomiaru współczynnika szumu. Przedstawiono nową czterostanową metodę pomiaru umożliwiającą uniezależnienie wskazań automatycznego miernika współczynnika szumu zarówno od wartośći wzmocnienia dwuwrotnika badanego jak i współczynnika szumu odbiornika pomiarowego. Wyprowadzone zależności...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.