Filtry
wszystkich: 404
Wyniki wyszukiwania dla: STATIC PILE LOAD TEST
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublikacjaThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Analysis of sloping brace stiffness influence on stability and load bearing capacity of a truss
PublikacjaThe paper is focused on the numerical study of stability and load bearing capacity of a truss with side elastic braces. The structure is made in reality. The rotational and sliding brace stiffnesses were taken into account. Linear buckling analysis and non-linear static analysis with geometric and material nonlinearity were performed for the beam and shell model of the truss with respect to the angle of sloping braces. As a result...
-
Determination of p-y curves for offshore piles based on in-situ soil investigations
PublikacjaOffshore piles are subjected to complex loads with considerable lateral component. The pile-soil response to lateral loads can be described with the p-y method. For a given depth the load–deflection relationship is built to simulate the surrounding soil stiffness. This state-of-art paper presents a brief discussion of determination methods for the p-y curves using a standard approach based on the soil parameters derived from laboratory...
-
Measurements of displacement and acceleration of the railway bridge at km 333-254 of the Vilnius - Klaipeda railway line
PublikacjaThe purpose of this work is to perform a report of static and dynamic test realized on the bridge at km 333-254 of the Vilnius - Klaipeda railway line over the Salantas River in Kūlupėnų.
-
Results of the “DPDT-Auger” Research Project on Screw Displacement Piles
PublikacjaThe main objective of the “DPDT-Auger” research project was to test the prototype DPDT auger for forming screw displacement piles in the ground (patented in Poland in 2020). An additional aim was to develop design methods and rules for the making of such piles. The augers and piles were first tested on a model scale, and then more extensively in the real scale on experimental field plots. The results found the overall functionality...
-
Tribological Properties of Thermoplastic Materials Formed by 3D Printing by FDM Process
PublikacjaThe dataset entitled 3D printed ABS thermoplastic vs. steel. Dry sliding wear test in constant load & velocity ring on flat configuration. Test parameters: print layer thickness and orientation. Test symbol: 019_h_4 contains: the time base (expressed in seconds and minutes), the friction torque for sliding friction, rotational velocity of the counter – specimen (velocity of sliding), friction coefficient, load in the friction contact...
-
ANALYSIS OF BRACE STIFFNESS INFLUENCE ON STABILITY OF THE TRUSS
PublikacjaThe paper is devoted to the numerical and experimental research of stability of a truss with side elastic supports at the top chord. The structure is a model of a real roof truss scaled by factor ¼. The linear buckling analysis and non-linear static analysis were carried out. The buckling length factor for the compressed top chord was calculated and the limit load for the imperfect truss shell model with respect to brace stiffness...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublikacjaA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
A novel sandwich footbridge - Practical application of laminated composites in bridge design and in situ measurements of static response
PublikacjaA novel sandwich composite footbridge is presented in the paper, as an example of practical application of laminated composites in civil engineering. The in situ static load tests of the footbridge before its acceptation for exploitation are shown and discussed. The results are compared with the corresponding ones from a numerical equivalent single layer model of the sandwich structure created within the framework of finite element...
-
Behaviour of deformed steel columns exposed to impact load during earthquakes: numerical analysis
PublikacjaIt has been observed during earthquakes that the so called soft-storey failure of an upper floor of a building leads to considerable vertical impact load acting on structural members of the lower storeys. The aim of this paper is to investigate numerically the behaviour of horizontally deformed columns (deformation as the result of earthquake loading) that are additionally subjected to vertical impact load. In the first stage of...
-
SEM images of Solid Oxide Fuel Cell interface with La0.6Sr0.4Co0.2Fe0.8O3-δ oxygen electrodes sintered at 1050 °C before and after test
Dane BadawczeThis dataset contains cross section SEM images of Solid Oxide Fuel Cell interface with La0.6Sr0.4Co0.2Fe0.8O3-δ oxygen electrode sintered at 1050 °C before and after test. The cell was tested using Open Flanges™ test Set-up at 700 °C. During the test, the cell was aged for approximately 120 hours at a load of 0.5 A/cm^2. Images were obtained using...
-
SEM images of Solid Oxide Fuel Cell interface with Sr0.95Ti0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C before and after test
Dane BadawczeThis dataset contains cross section SEM images of Solid Oxide Fuel Cell interface with Sr0.95Ti0.30Fe0.70O3-d oxygen electrode sintered at 800 °C before and after test. The cell was tested using Open Flanges™ test Set-up at 700 °C. During the test, the cell was aged for approximately 120 hours at a load of 0.5 A/cm^2. Images were obtained using a FEI...
-
The use of GFRP tubes as load-bearing jackets in concrete-composite columns
PublikacjaThe paper presents the fields of applications of polymer composites in building structures. The use of composite glass fibre tubes is discussed in more detail. The laboratory methods used to test the mechanical properties of these pipes are presented. An original research program is presented, including six concrete-filled glass fibre tubes. The cylinders and columns made in this way were tested for their axial load capacity. Conclusions...
-
Multi Parameter Sliding Test Result Evaluation for The Selection of Material Pair for Wear Resistant Components of a Hydraulic motor Dedicated for Use With Environmentally Friendly Working Fluids
PublikacjaIn the paper the method and results are presented of the testing of tribological performance of a number of hard materials available commercially. The tests consisted in unidirectional sliding with liquid lubrication. The load and velocity regime chosen were similar to a standard four-ball lubricity test with constant velocity and load increasing over time. The regime was modified in such a way that over the initial part of the...
-
Report no WOiO/II/67/2015 - Expertise about load capacity of twistlock foundation and sliding foundation
PublikacjaCustomer delivered to Laboratory 17 elements - twist lock foundations and sliding lock foundations (ship equipment for container lashing). Elements were selected from production series. Each element was loaded for braking load. After test visual inspection had been performed. The expertise contains: description of tested elements, test assumptions, test stand, results and conclusions
-
Results of nanoindentation test to calculate residual stress in an eyelet of undercarriage drag strut after laser treatment
Dane BadawczeIn order to determine the residual stress in the laser-processed an eyelet of undercarriage drag strut, a nanoindentation test was performed before and after stress relief annealing. For this purpose, after the hardness test, the sample was subjected to stress relief annealing at 270 °C for 2 hours. Annealing was performed in a vacuum furnace. Hardness...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublikacjaAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Effect of pavement roughness and vehicle dynamic loads on decrease of fatigue life of flexible pavements
PublikacjaDue to the fact that pavement surfaces are not ideally even, dynamic loads of vehicle axles deviate from static loads. Higher dynamic loads contribute to faster pavement distress. The distribution of dynamic loads is similar to normal distribution and can be described by static load and factors DI (dynamic impact) and DLC (dynamic load coefficient). With the deterioration of pavement condition its evenness decreases as well and...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K07
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K06
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K04
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K08
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig:...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K02
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K05
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K03
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). No lubrication (DRY). Specim. set K01
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DRY. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig:...
-
Optical microsc. images of wear marks on ball (JPG). Reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - DISTILLED WATER. Specim. set K06
Dane BadawczeOptical microscope images of wear zone on the 5mm diam. ceramic ball used in tests as the fixed specimen.Friction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: DISTILLED WATER. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test...
-
Stability of a truss under upward wind loading
PublikacjaThe present paper is devoted to the numerical investigations of stability of a truss under upward wind load. The truss is braced at its the upper cord. A structural variant including lateral braces, or lateral and torsional braces is considered. The research presents the problems of linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity are presented. The initial...
-
Impact of power electronic Var compensators installed in certain grid points on the voltage failure
PublikacjaThe article presents the test results of the various types of static compensators FACTS models in the power system. The basic case, which was analyzed, it was behavior of compensators which are installed in select points of the system during voltage failure. The article presents selected results of studies conducted as part of a work [2].
-
Dynamic characteristics of the proton exchange membrane fuel cell module
PublikacjaThe paper describes a fuel cell based system and its performance. The system is based on two fuel cell units, DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and a set of measurement instruments. In the study presented in the paper a dynamic response of the proton exchange membrane (PEM) fuel cell system to unit step change load as well as to periodical load changing cycles...
-
ENERGY ANALYSIS OF PROPULSION SHAFT FATIGUE PROCESS IN ROTATING MECHANICAL SYSTEM PART I TESTING SIGNIFICANCE OF INFLUENCE OF SHAFT MATERIAL FATIGUE EXCITATION PARAMETERS
PublikacjaThe article discusses the problem of mathematical modelling of energy conversion processes in a rotating mechanical system for the purpose of identifying fatigue states of propulsion shafts in this system. A simplified physical model of the analysed system, constructed in an appropriate scale, has made the basis for the experimental research. The research programme took into consideration mechanical fatigue excitation of the model...
-
REINFORCED CONCRETE SUPPORTING CONSTRUCTION OF THE STADIUM COVER FOR EURO 2012 IN GDAŃSK
PublikacjaIn the article structural issues that connected with the reinforced concrete supporting construction of the stadium roofing for EURO 2012 in Gdańsk were described. In the first part of the article the concept of stadium foundation were described. In the second the static - strength analysis for two variants fastening together individual foundation elements were made. The two assumed geometrically different concept of foundation...
-
Pedestrian on footbridges, vertical loads and response
PublikacjaThe paper is a synthesis of the experimental and theoretical investigations on dynamics of pedestrian bridges under vertical load The subject is divided into four issues.1) The pedestrian as a vertical dynamic load on footbridges, theoretic load function for walking and crouching.2) Crowd walking on the footbridge - pedestrian flow.3) Vertical lock-in effect.4) Response of the footbridge - numeric and side test results, -...
-
Field investigation of low-temperature cracking and stiffness moduli on selected roads with conventional and high modulus asphalt concrete
PublikacjaHigh Modulus Asphalt Concrete (HMAC) was introduced in Poland as a one of the solutions to the problem of rutting, type of deterioration common in the 1990s. After first encouraging trials in 2002 HMAC was widely used for heavily loaded national roads and motorways. However some concerns were raised about low-temperature cracking of HMAC. This was the main reason of the studies presented in this article were started. The article...
-
Establishing Relationships between Parameters of the controlled Compaction Soil by Using Various In-Situ Tests
PublikacjaThe aim of research was evaluating reliable correlations between chosen soil parameters describing state of surface layers of soil. The paper presents site comparative tests based on the light falling weight deflectometer (LFWD), the static plate load tester (VSS), the dynamic probing light tester (DPL) and the bearing ratio tester (CBR in-situ) with relationships between soil state parameters. All featured in-situ...
-
Nonlocalized thermal behavior of rotating micromachined beams under dynamic and thermodynamic loads
PublikacjaRotating micromachined beams are one of the most practical devices with several applications from power generation to aerospace industries. Moreover, recent advances in micromachining technology have led to huge interests in fabricating miniature turbines, gyroscopes and microsensors thanks to their high quality/reliability performances. To this end, this article is organized to examine the axial dynamic reaction of a rotating...
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublikacjaW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublikacjaW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
Inverse Analysis as a Key Element of Safety Assessment under the Snow Load For The Large Suspension Roofs Structure
PublikacjaThe paper presents a concept and realization of monitoring system for the Silesian Stadium in Chorzow. The idea of the system lies in fusion of structure monitoring with a calibrated numerical FEM model [1]. The inverse problem is solved. On the base of measured selected displacements, the numerical FEM model of the structure combined with iterative method, develops the current snow load distribution. Knowing the load, we can calculate...
-
Underfrequency Load Shedding: An Innovative Algorithm Based on Fuzzy Logic
PublikacjaIn contemporary power systems, the load shedding schemes are typically based on disconnecting a pre-specified amount of load after the frequency drops below a predetermined value. The actual conditions at the time of disturbance may largely dier from the assumptions, which can lead to non-optimal or ineective operation of the load shedding scheme. For many years, increasing the eectiveness of the underfrequency load shedding (UFLS)...
-
The Application of Vibration Recording and Analysis in Tribological Research on Sliding Friction
PublikacjaThe paper reports on a tribological research on the macroscopic manifestation and characteristics of sliding friction. The aim of the task was to measure friction in lubricated sliding contacts and test the interactions between the environment (the test rig) and the experimental friction contact. Friction-induced vibrations were observed and studied as a manifestation of the process. The typical set of velocity and force/torque...
-
Characterization of corrosion in reinforced concrete beams using destructive and non-destructive tests
PublikacjaThe paper presents both non-destructive and destructive experimental tests on steel-reinforced concrete beams subjected to electrochemical corrosion. To examine the condition and behavior of the specimens, destructive tests were carried out, i.e., a three-point bending together with a modulated ultrasonic wave test. In addition, a series of non-destructive experiments were conducted, such as the potential measurement method, low-frequency...
-
The influence of welding heat input on the quality and properties of high strength low-alloy dissimilar steel butt joints
PublikacjaThe paper presents the results of non-destructive and destructive tests of dissimilar highstrength low-alloy S460ML and S460N steel butt joints. These steels are characterized by similar mechanical properties, but their carbon equivalent CeIIW values are much different. The joints were made using different values of heat input for each welding bead. They were tested by non-destructive methods: visual, penetrant, radiographic and...
-
Effect of long term service at elevated temperatures on mechanical properties of Manaurite XM reformer tubes
PublikacjaMicrostructure transformations occur in the Manaurite XM cast steel tubes during long-term operation in the reformer furnace were revealed and described. The rela tionship between mechanical properties, an increase of internal diameter of the tube and microstructure degradation is discussed. Static tensile test was performed on two types of samples with different shapes. It has been shown differences in the results of tests...
-
Simple empirical formula to estimate the main geomechanical parameters of preplaced aggregate concrete and conventional concrete
PublikacjaPreplaced aggregate concrete (PAC) or two-stage concrete is a specific type of concrete successfully employed in many projects including underwater concrete structures, massive concrete structures, structures made of reinforced concrete, and improvement of concrete structures. PAC is significantly different than the conventional concrete. In this type of concrete, aggregates are initially poured into the mold, the voids between...
-
Stability and load bearing capacity of a truss with elastic braces
PublikacjaThe present paper is devoted to the numerical and experimental investigations of stability of a truss stiffened by elastic braces. The model of a real roof truss scaled by factor ¼ was investigated. In the research the linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity is presented. The initial imperfections were assumed in the form of the first buckling mode....
-
Sensorless Disturbance Detection for Five Phase Induction Motor with Third Harmonic Injection
PublikacjaThe paper presents a sensorless disturbance detection procedure that was done on a five phase induction motor with third harmonic injection. A test bench was developed where a three phase machine serves as disturbance generator of different frequencies. The control of the machines is based on multi scalar variables that ensures an independent control of the motor EMF and the rotor flux. For disturbance identification a speed observer...