Filtry
wszystkich: 6193
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: VOLTAGE-TO-TIME CONVERTER
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Simulation of influence of the air gap asymmetryon voltage waveforms of a synchronous machine
PublikacjaResults of simulation of a synchronous generator with the air gap asymmetry characterised by eccentricity are presented in the paper. The Lagrange's energy method has been used in derivation of the model equations. Analysis of influence of the air gap asymmetry on characteristics of self and mutual inductances of windings, as well as analysis of induced voltage waveforms as a function of the air gap asymmetry have been performed....
-
Parallel implementation of background subtraction algorithms for real-time video processing on a supercomputer platform
PublikacjaResults of evaluation of the background subtraction algorithms implemented on a supercomputer platform in a parallel manner are presented in the paper. The aim of the work is to chose an algorithm, a number of threads and a task scheduling method, that together provide satisfactory accuracy and efficiency of a real-time processing of high resolution camera images, maintaining the cost of resources usage at a reasonable level. Two...
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublikacjaA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublikacjaA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Modular power converter with superconducting magnetic energy storage for electric power distribution system — Analysis and simulation
PublikacjaThis paper describes selected issues concerning realization of energy storage system (ESS) designed to operate in power distribution system. This paper presents a modular approach of 300 kVA power converter operating with superconducting magnetic energy storage (SMES), which gives high dynamics together with high power and suitable capability for instantaneous energy storage. Analysis and simulation studies of selected power converter...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublikacjaThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Modeling the effect of parasitic capacitances on the dead-time distortion in multilevel NPC inverters
PublikacjaA simple model is derived and verified for evaluating the effect of parasitic capacitances on the dead-time related voltage distortion in multilevel NPC voltage source inverters. The model permits well-defined and precise compensation of dead-time distortion, exhibiting meaningful improvement on compensation methods neglecting the effects of parasitic capacitances. A simple formula is given for evaluating the capacitances as serial/parallel...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublikacjaThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Exact generation of voltage vector in voltage inverter with pulse width modulation
PublikacjaW artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublikacjaThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Swapping Space for Time: An Alternative to Time-Domain Interferometry
PublikacjaYoung's double-slit experiment [1] requires two waves produced simultaneously at two different points in space. In quantum mechanics the waves correspond to a single quantum object, even as complex as a big molecule. An interference is present as long as one cannot tell for sure which slit is chosen by the object. The more we know about the path, the worse the interference. In the paper we show that quantum mechanics allows for...
-
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublikacjaThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublikacjaIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublikacjaIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Sensorless induction motor drive with voltage inverter and sine-wave filter
PublikacjaThis paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
REAL-TIME IMAGING
Czasopisma -
Timing and Time Perception
Czasopisma -
Appita TIME Magazine
Czasopisma -
REAL-TIME SYSTEMS
Czasopisma -
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Gaoya Dianqi/High Voltage Apparatus
Czasopisma -
Gaodianya Jishu/High Voltage Engineering
Czasopisma -
Design of an Autonomous IoT Node Powered by a Perovskite-Based Wave Energy Converter
PublikacjaThis paper presents the results of experimental research focused on wave energy harvesting and its conversion to power Internet of Things (IoT) devices. The harvesting and conversion process was performed using a wave energy converter (WEC) consisting of a lead zirconate titanate piezoelectric ceramic perovskite material and a prototype power electronic circuit. The designed WEC was considered as a power supply for an end node...
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublikacjaIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublikacjaThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublikacjaThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publikacjahe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Comparative analysis of switched reluctance motor control algorithms
PublikacjaПредмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...
-
Comparative analysis of switched reluctance motor control algorithms
PublikacjaПредмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...
-
Analysis of pressure ratio in the intake in dependence on high-voltage behaviours
PublikacjaPower control in spark ignition engines by regulating the intake air is performed. The control unit needs information about the air pressure conditions which then enters the combustion chamber. The information about the intake air pressure is an important quantity for optimal control of combustion mixtures. The paper describes some types of sensors that are used to measure the air intake temperature. Air pressure in the intake...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublikacjaThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublikacjaLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
ELECTIVE PROJECT II _sem 5_Green Story - Free Time Space
Kursy OnlineThe topic of the course - Green Story - Free Time Space, joins green architecture and a place to spend free time - inside and outside – to read, to eat, to relax. The idea is to design green – to give back the greenery to the public square – to make a city space more friendly for users and more friendly to the environment. You can design a story, to make a space more attractive. You can design a Green Story, to make people more...
-
A non-uniform real-time speech time-scale stretching method
PublikacjaAn algorithm for non-uniform real-time speech stretching is presented. It provides a combination of typical SOLA algorithm (Synchronous Overlap and Add ) with the vowels, consonants and silence detectors. Based on the information about the content and the estimated value of the rate of speech (ROS), the algorithm adapts the scaling factor value. The ability of real-time speech stretching and the resultant quality of voice were...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
Quantum entanglement in time
PublikacjaIn this paper we present a concept of quantum entanglement in time in a context of entangled consistent histories. These considerations are supported by presentation of necessary tools closely related to those acting on a space of spatial multipartite quantum states. We show that in similarity to monogamy of quantum entanglement in space, quantum entanglement in time is also endowed with this property for a particular history....
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublikacjaIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublikacjaThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
A FPTAS for minimizing total completion time in a single machine time-dependent scheduling problem
PublikacjaIn this paper a single machine time-dependent scheduling problem with total completion time criterion is considered. There are given n jobs J1,…,Jn and the processing time pi of the ith job is given by pi=a+bisi, where si is the starting time of the ith job (i=1,…,n),bi is its deterioration rate and a is the common base processing time. If all jobs have deterioration rates different and not smaller than a certain constant u>0,...