Wyniki wyszukiwania dla: SATURATION TEMPERATURE
-
Results of implementation of Feed Forward Neural Networks for modeling of heat transfer coefficient during flow condensation for low and high values of saturation temperature
Dane BadawczeThis database present results of implementation of Feed Forward Neural Networks for modeling of heat transfer coefficient during flow condensation for low and high values of saturation temperature. Databse contain one table and 7 figures.
-
Experimental study of flow boiling pressure drop and heat transfer of R1233zd(E) at moderate and high saturation temperatures
PublikacjaThe paper presents the results of experimental study of flow boiling of R1233zd(E) in minichannel at moderate and high saturation temperatures. The heat transfer coefficient and pressure drop were measured for flow boiling in a stainless steel tube with 2 mm inside diameter and a length of 300 mm. Experiment has been conducted for saturation temperatures ranging from 83 to 145 °C which corresponds to values of reduced pressures...
-
Pressure drop and heat transfer during boiling and condensation at subcritical region
PublikacjaMost of the data presented in the literature relate to saturation temperatures in the range - 20°C to 40°C due to the application in refrigeration technology. There is necessity to extend databases to higher values of saturation temperature due to new applications such as Organic Rankine Cycle and high temperature heat pumps. Only few papers contain data for high reduced pressure for low boiling point liquids. This paper focus...
-
Modelling study of flow boiling heat transfer of perspective fluids for refrigeration technology
PublikacjaThere is a gap of knowledge on flow boiling at high saturation temperatures and higher values of reduced pressure. Thus far, the in-house developed semi-empirical model for flow boiling and flow condensation showed a satisfactory accuracy for calculations for various refrigeration fluids for a wide scope of reduced pressures. This study presents results of calculations of heat transfer coefficient of perspective refrigeration fluids,...
-
Experimental study and comparison with predictive methods for flow boiling heat transfer coefficient of HFE7000
PublikacjaThis article describes an experimental study of flow boiling of HFE7000 inside a smooth vertical channel. The investigation has been carried out in a circular stainless-steel tube with an inner diameter of 2.3 mm. The data have been collected for the applied heat fluxes q ranging from 61 to 205 kW/m2, the mass flux G ranging from 214 to 1006 kg/(m2 s), the saturation temperature Tsat ranging from 30 to 54 °C and the full range...
-
Conductivity and viscosity changes of imidazolium ionic liquids induced by H2O and CO2
PublikacjaSeveral solutions of ionic liquids based on 1-ethyl-3-methylimidazolium cation saturated and unsaturated with carbon dioxide were prepared and characterized by electrochemical impedance spectroscopy. The in fluence of ILs saturation on its electrical conductivity was determined. Additionally, the in fluence of the water presence and variations of temperature on electrical properties of ionic liquids were investigated. Changes of...
-
Investigations on mixture preparation for two phase adiabatic pressure drop of R134a flowing in 5 mm diameter channel
PublikacjaThe article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a. Study cases have been set for a mass flux varying from 200 to 400 kg/m2 s, at the saturation temperature of 19.4 ◦C. Obtained experimental data was compared with the available correlations from the literature for the frictional pressure drop during adiabatic flow. Influence of mixture preparation on pressure drop was investigated, for...
-
Flow Maps and Flow Patterns of R1233zd(E) in a Circular Minichannel at Low, Medium and High Values of Saturation Pressure
PublikacjaThere is a gap in knowledge regarding the flow pattern of low-boiling working fluids in the range of high saturation temperatures (above 120°C) and medium and high reduced pressures (0.5-0.9). Data are present in the literature for similar values of reduced pressures, but for lower values of saturation temperature. This is due to the existing refrigeration applications of these working fluids. At high values of reduced pressure,...
-
Detailed experimental investigations on frictional pressure drop of R134a during flow boiling in 5 mm diameter channel: The influence of acceleration pressure drop component =Études expérimentales détaillées sur la chute de pression frictionnelle du R134a lors de l'ébullition en écoulement dans un canal de 5 mm de diamètre : influence de la composante d'accélération de la chute de pression
PublikacjaThis article presents detailed two-phase diabatic pressure drop data for refrigerant R134a at a saturation pressure of 5.5 bar corresponding to the saturation temperature of 19.4 °C. Study cases have been set for a mass flux varying from 100 to 500 kg m−2 s−1. The obtained data are used as a validation of the void fraction literature models, a set of graphs shows comparisons, for a representative set of experimental conditions,...
-
Synthesis of CoFe2O4 Nanoparticles: The Effect of Ionic Strength, Concentration, and Precursor Type on Morphology and Magnetic Properties
PublikacjaThe present study highlights the effect of metal precursor types (SO4 2¯, Cl¯, and NO3¯), their concentration, and the influence of ionic strength of reaction environment on the morphology, surface, and magnetic properties of CoFe2O4 particles. The magnetic nanoparticles were obtained by chemical coprecipitation in alkaline medium at increasing metal concentration in the range of 0.0425 mol·dm-3 to 0.17 mol·dm-3 and calcination...
-
Experimental investigations on adiabatic frictional pressure drops of R134a during flow in 5mm diameter channel
PublikacjaThe article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a at a saturation pressure of 5.5 bar corresponding to the saturation temperature of 19.4 °C. Study cases have been set for a mass flux varying from 100 to 500 kg/m2 s. The frictional pressure drop was characterized for the refrigerant R134a, for vapor qualities ranging from 0 to 1. Long-time thermal stability of test facility allowed to gather...
-
Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels
PublikacjaAttention is focused on the issues of flow resistance and pressure drop of perspective refrigeration fluids during condensation in the two-phase flow in minichannels. The case of the flow through a cylindrical single channel of 2.3 mm inner diameter was carefully analyzed. Pressure drop tests have been performed in diabatic flow conditions. The effect of heat flux, mass flux, vapour quality and saturation temperature on the two-phase...
-
Systematic Water Uptake Energetics of Yttrium-Doped Barium Zirconate—A High Resolution Thermochemical Study
PublikacjaA combination of surface area analyzer and microcalorimetry was employed to investigate the in situ water uptake energetics and the mechanism of proton incorporation in yttrium-doped barium zirconate in the temperature range 200–400 °C. The BaZr1–xYxO3 solid solutions are made with variable yttrium content (x = 10, 20, and 30 mol %) by a controlled oxidant-peroxo synthesis method. The water uptake increases as the partial pressure...
-
Tuning the photocatalytic performance through magnetization in Co-Zn ferrite nanoparticles
PublikacjaIn this work, the link between the photocatalytic performance of Co-Zn ferrite nanoparticles and the net magnetic moment is analyzed. CoxZn1-xFe2O4 nanoparticles (0 ≤ x ≤ 1) were synthesized by co-precipitation method and different physicochemical techniques were employed to characterize the samples (X-ray diffraction, Transmission Electron Microscopy (TEM), BET surface area, Diffuse Reflectance Spectroscopy (DRS), Photoluminescence spectroscopy,...
-
Charge density wave, enhanced mobility, and large nonsaturating magnetoresistance across the magnetic states of HoNiC2 and ErNiC2
PublikacjaWe report on magnetotransport and thermoelectric properties of two ternary carbides HoNiC2 and ErNiC2 hosting both charge density wave and long-range magnetic order. In the charge density wave state, both compounds show relatively large magnetoresistance MR ≈ 150% in HoNiC2 and ≈ 70%in ErNiC2 at a magnetic field of 9 T and temperature as low as 2 K. This positive field-linear magnetoresistance shows no signatures of saturation....
-
Understanding the kinetics and atmospheric degradation mechanism of chlorotrifluoroethylene (CF2=CFCl) initiated by OH radicals
PublikacjaThe atmospheric degradation of chlorotrifluoroethylene (CTFE) by OH˙ was investigated using density functional theory (DFT). The potential energy surfaces were also defined in terms of single-point energies derived from the linked cluster CCSD(T) theory. With an energy barrier of −2.62 to −0.99 kcal mol−1 using the M06-2x method, the negative temperature dependence was determined. The OH˙ attack on Cα and Cβ atoms (labeled pathways...
-
Experimental validation of pressure drop models during flow boiling of R134a – effect of flow acceleration and entrainment
PublikacjaA crucial step to assure proficient work of power and process apparatus is their proper design. A wide array of those devices operates within boiling or condensation of the working fluid to benefit from high heat transfer rates. Two-phase flows are associated with high heat transfer coefficients because of the latent heat of evaporation and high turbulence level between the liquid and the solid surface. Predicting heat transfer...
-
Flow boiling intensification in minichannels by means of mechanical flow turbulising inserts
PublikacjaThe work presents the results of experimental investigation on heat transfer in minichannels. Refrigerant R123 was used as a test fluid. Single vertical silver tubes of 380 mm length and 2.3 mm diameter were examined with two variants of turbulising inserts. A wide range of parameters was considered, namely mass flux G=534-3011 kg/(m2s), heat flux qw=28.5-68.4 kW/m2, saturation temperature Tsat=23-86 stC and the full range of vapour...
-
The effect of reduced pressure on carbon dioxide flow boiling heat transfer in minichannels
Publikacja. In the paper presented are the results of the study on the effect of reduced pressure on flow boiling heat transfer data in minichannels as well as conventional ones. That effect renders that most of heat transfer correlations fail to return appropriate results of predictions. Mostly they have been developed for the reduced pressures from the range 0.1-0.3. The special correction has been postulated to the in-house model of flow...
-
Immobilization on magnetic nanoparticles of therecombinant trehalose synthase from Deinococcusgeothermalis
PublikacjatIn our study the gene encoding trehalose synthase from Deinococcus geothermalis was cloned and overexpressed inEscherichia coli Rosetta (DE3)pLysS. Wild-type trehalose synthase has been purified from host protein after cell dis-ruption and precipitation at 20% ammonium sulphate saturation. Recombinant trehalose synthase was immobilizedonto glutaraldehyde activated silanized magnetic ferrous-ferric oxide by using covalent binding...
-
Selected aspects of performance of organic Rankine cycles incorporated into bioenergy with carbon capture and storage using gasification of sewage sludge
PublikacjaThe study aims to investigate the application of the Organic Rankine Cycle (ORC) in the bioenergy with carbon capture and storage (BECCS) using gasification of sewage sludge. The tool used in the investigation is the Aspen Plus software with REFPROP property methods for calculating fluid properties. The reason for this study is that a detailed analysis of the proposed BECCS process flow diagram indicates that a certain amount of...
-
Assessment, optimisation and working fluid comparison of organic rankine cycle combined with negative CO2 gas power plant system
PublikacjaThis study aims to investigate the application of the Organic Rankine Cycle (ORC) as an alternative to low-pressure expansion in the negative CO2 power plant (nCO2PP). The reason for this study is that a detailed analysis of nCO2PP indicates a certain amount of waste heat present in the exhaust gas from the high-to-intermediate pressure gas turbine. Some of this energy can be used by the application of the expansion in a low-pressure...
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Jan Wajs dr hab. inż.
Osoby -
Modelling of heat transfer during flow condensation of natural refrigerants under conditions of increased saturation pressure
PublikacjaThe paper presents a modified in-house model for calculating heat transfer coefficients during flow condensation, which can be applied to a variety of working fluids, but natural refrigerants in particular, at full range thermodynamic parameters with a particular focus on increased saturation pressure. The modified model is based on a strong physical basis, namely the hypothesis of analogy between the heat transfer coefficient...
-
Comparison of heat transfer characteristics in surface cooling using microjets with water, ethanol and HFE7100 as test fluids
PublikacjaAccurate control of cooling parameters is required in ever wider range of technical applications. It is known that reducing the dimensions of the size of nozzle leads to an increase in the economy of cooling and improves its quality. Present study describes research related to the design and construction of the nozzles and microjet study, which may be applied in many technical applications such as in metallurgy, electronics, etc....
-
Data points of structures of R1233zd(E) flowing in a circular minichannel at low, medium and high values of saturation pressure
Dane BadawczeDatabase present structures of two-phase flow of R1233zd(E) in 3 mm vertical channel. Database contains datapoints which contain information of reduced pressure (ratio of saturation pressure and critical pressure), quality and mass velocity. 4 two phase structures are distinguished: bubbly flow, slug flow, intermittent flow and annular flow.
-
Simplified saturation modelling in three-leg power transformer for the system stability analisys
PublikacjaThe paper presents a simplified method for modelling non-linearity of the magnetic circuit of the power transformer. The saturation effect is implemented by describing the self and mutual inductances as a function of the magnetic flux. The most important element of this function is the saturation coefficient which is calculated based on transient state during the unloaded transformer switch on. The transformer model is described...
-
Modelling of steady state and transient performance of the synchronous generator considering harmonic distortions caused by non-uniform saturation of the pole shoe
PublikacjaIn this paper a synchronous generator model is described. This model is developed on the assumption that in loaded and no load conditions the saturation effect affects the pole shoe in a different way. The developed model is based on the multiple saliency model and is formulated using winding function approach in machine variables. The influence of the non-uniform saturation of the pole shoe in load conditions on the performance...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublikacjaIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
The effect of chitosan concentration and molecular weight on endotoxin content
Dane BadawczeThe dataset includes results to determine the effect of chitosan concentration and molecular weight on endotoxin content as well as the effect of purification methods. The endotoxin concentration was determined using the PyroGene Recombinant Factor C Endpoint Fluorescent Assay. Chitosan 0.6% in 0.1M glycolic acid from Chemat LMW, MMW, and HMW were used...
-
Development of an emulation platform for synchronous machine power generation system using a nonlinear functional level model
PublikacjaThe article presents the Power Hardware in the Loop (PHIL) approach for an autonomous power system analysis based on the synchronous generator model incorporating magnetic saturation effects. The model was prepared in the MATLAB/Simulink environment and then compiled into the C language for the PHIL platform implementation. The 150 kVA bidirectional DC/AC commercial-grade converter was used to emulate the synchronous generator....
-
Application of Feed Forward Neural Networks for Modeling of Heat Transfer Coefficient During Flow Condensation for Low and High Values of Saturation Temperatur
PublikacjaMost of the literature models for condensation heat transfer prediction are based on specific experimental parameters and are not general in nature for applications to fluids and non-experimental thermodynamic conditions. Nearly all correlations are created to predict data in normal HVAC conditions below 40°C. High temperature heat pumps operate at much higher parameters. This paper aims to create a general model for the calculation...
-
A novel heterogeneous model of concrete for numerical modelling of ground penetrating radar
PublikacjaThe ground penetrating radar (GPR) method has increasingly been applied in the non-destructive testing of reinforced concrete structures. The most common approach to the modelling of radar waves is to consider concrete as a homogeneous material. This paper proposes a novel, heterogeneous, numerical model of concrete for exhaustive interpretation of GPR data. An algorithm for determining the substitute values of the material constants...
-
The effect of raw material type on endotoxin content .
Dane BadawczeThe datasets contain the results of determining the effect of raw material type on endotoxin content as well as the effect of purification methods. The endotoxin concentration was determined using the PyroGene Recombinant Factor C Endpoint Fluorescent Assay. Beckmann-Kenko sodium alginate and Chemat sodium salt of alginic acid were used for the assays....
-
Application capabilities of the maximum distributed generation estimate methodology
PublikacjaThe paper presents application capabilities of the maximum distributed generation estimate methodology. This subject is an example of solutions to the problem that today face the transmission system operator and distribution system operators, which is related to the high saturation with wind power generation predicted for the near future.
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublikacjaThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
Synchronous generator model taking into account the non-uniform saturation of the pole shoes
PublikacjaFor the evaluation of modern electric power systems with regard to their behavior, weight, and reliability a novel modeling and simulation tools have been developed. The paper presents circuit model of synchronous generator taking into account both the non-sinusoidal distribution of the stator and rotor winding, and non-uniform saturation of the pole shoes. This model is suitable for simulation of both salient and no-salient pole...
-
Half-Order Modeling of Saturated Synchronous Machine
PublikacjaNoninteger order systems are used to model diffusion in conductive parts of electrical machines as they lead to more compact and knowledge models but also to improve their precision. In this paper a linear half-order impedance model of a ferromagnetic sheet deduced from the diffusion of magnetic field is briefly introduced. Then, from physical considerations and finite elements simulation, the nonlinear half-order impedance model...
-
Flow boiling of R1233zd(E) in a 3 mm vertical tube at moderate and high reduced pressures
PublikacjaThe results of flow boiling of R1233zd(E) in a 3 mm vertical stainless steel tube are presented at moderate and high saturation temperatures. Integral flow characteristics in the form of pressure drop and heat transfer coefficient are discussed for saturation temperatures ranging from 115 to 145 °C (corresponding reduced pressures from 0.2 to 0.7), mass velocity of 800 kg/m2s and heat flux of 20 kW/m2. All of the obtained heat...
-
A method of nonlinearities of transformer no-load characteristic modelling
PublikacjaA way in which changes of the no-load characteristic are taken into account in the mathematical model of the transformer is presented. Changes of saturation within core of transformer are presented as a combined non-linear flux curve. Analysis of magnetization of the transformer core and simulation of no-load state for distribution transformer of 30 kVA power rating and 15.75/0.4 kV/kV (especially supplying VLV) transformation...
-
Lagrangian model of an isolated dc-dc converter with a 3-phase medium frequency transformer accounting magnetic cross saturation
PublikacjaThis article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core-type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves...
-
Multimedia in teaching economics and management in higher education.
PublikacjaNowadays, the use of multimedia teaching materials at universities makes a standard practice. However their saturation is still quite low comparing to the expectations of students - the main consumers of the information contained therein. This article will present the results of research conducted among students of Management and Engineering Management carried at the Technical University of Gdańsk. Some students of Computer Science...
-
A scale with ECG measurements capability for home cardiac monitoring
PublikacjaPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Effect of free water on the quasi‑static compression behavior of partially‑saturated concrete with a fully coupled DEM/CFD approach.
PublikacjaThe work aims to numerically investigate the quasi-static response of partially fluid-saturated concrete under two-dimensional uniaxial compression at the mesoscale. We investigated how the impact of free pore fluid content (water and gas) affected the quasi-static strength of concrete. The totally and partially fluid-saturated concrete behavior was simulated using an improved pore-scale hydro-mechanical model based on DEM/CFD....
-
Investigation on water infiltration and water content changes in a large-scale experimental test dike
PublikacjaThe paper presents result of series of experiments made within the DREDGDIKES project, performed on a test dike built from composite soil. The composite is produced by mixing fly ash (by-product of energetics) with dredged material (sand) taken from the mouth of The Vistula river. The test dike, located near Gdansk in Poland, was subjected to hydraulic load in several flooding time scenarios and the unsaturated unsteady flow was...
-
A Concept of Automatic Film Color Grading Based on Music Recognition and Evoked Emotions
PublikacjaThe article presents the aspects of the final selection of the color of shots in film production based on the psychology of color. First of all, the elements of color processing, contrast, saturation or white balance in the film shots were presented and the definition of color grading was given. In the second part of the article the analysis of film music was conducted in the context of stimulating appropriate emotions while watching...
-
Experiments and Analysis of the Limit Stresses of a Magnetorheological Fluid
PublikacjaPaper presents the results of a rheological test of a commercial magnetorheological (MR) fluid (MRF-132DG). The researchincludes the problem of measuring and interpreting limit stresses under conditions close to the magnetic saturation of the fluid. Fourdifferent limit stresses were determined, two related to the yield point and two related to the flow point. Methods for determining limitstresses, especially due to excitation...
-
Water sorption and blistering of GFRP laminates with varying structures
PublikacjaThe microstructures, water absorption as well as blistering was studied for bi- and tri- axial glass fibre vinyl ester and polyester -matrix laminates coated with gel coat layer and uncoated. The effect of manufacturing technique on water sorption characteristics was considered. It was found that water sorption characteristics of GFRP depend on manufacturing methods. The least water intake was found for specimens having perfect...