Wyniki wyszukiwania dla: SOLID-CONTACT
-
Solid-Contact pH Sensor without CO2Interference with a Superhydrophobic PEDOT-C14as Solid Contact: The Ultimate “Water Layer” Test
Publikacja -
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publikacja -
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublikacjaThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
FURTHER REMARKS ON THE SURFACE VIS IMPRESSA CAUSED BY A FLUID-SOLID CONTACT
PublikacjaIt is well-known that, nano-mechanics should take into account not only physical phenomena occuring within the bulk but, first of all, the physical phenomena appropriate for a surface of two materials contact. The huge volume density of internal surfaces as well countours lines located within the nanomaterial results in our interest in, apart from classical form of mass, momentum and entropy transport, those modes of transportation...
-
Ion-Selective Electrodes with Solid Contact Based on Composite Materials: A Review
Publikacja -
Novel usage of perinone polymer as solid contact in ion-selective electrodes
Publikacja -
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublikacjaA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publikacja -
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publikacja -
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublikacjaThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Chloride Ion-Selective Electrode with Solid-Contact Based on Polyaniline Nanofibers and Multiwalled Carbon Nanotubes Nanocomposite
Publikacja -
Conventional and solid-contact lithium-selective electrodes based on tris(N,N-dicyclohexylamide) neutral ionophore
PublikacjaKonstruowano jonoselektywne elektrody litowe (Li-ISEs) z membraną polimerową i obojętnym jonoforem tris(N,N-dicycloheksyloamidem) jako: elektrodę konwencjonalną (z wodnym roztworem elektrolitu wewnętrznego) oraz ze stałym kontaktem (polianilina jako przekaźnik jonowo-elektronowy). Charakterystyki obu elektrod (nachylenie i zakres liniowy) są porównywalne. Badana elektroda ze stałym kontaktem wykazuje dobrą stabilność w czasie....
-
Comparative Study of Potassium Ion-Selective Electrodes with Solid Contact: Impact of Intermediate Layer Material on Temperature Resistance
Publikacja -
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publikacja -
Wykonanie i zastosowanie układów złożonych z miniaturowych (solid-contact) elektrod jonoselektywnych do badań biomedycznych
PublikacjaW rozprawie doktorskiej przedstawiono konstrukcję i parametry miniaturowych elektrod jonoselektywnych (EJS) użytych do budowy zintegrowanych platform czujnikowych, które mogą mieć potencjalne zastosowanie w badaniach biomedycznych i klinicznych. Wykazano wpływ lepkości roztworu na zakres liniowy pracy EJS oraz wpływ temperatury przechowywania próbek śliny na ich skład jonowy. Praca badawcza obejmowała zaprojektowanie, wykonanie...
-
Membranowe elektrody jonoselektywne typu solid-contact-ich charakterystyka, materiały do ich konstrukcji i zastosowanie analityczne
PublikacjaCzujniki chemiczne są urządzeniami analitycznymi dostarczającymi informacji o składzie chemicznym próbki w czasie rzeczywistym. Składają się z dwóch podstawowych elementów: z części receptorowej i przetwornikowej. W idealnej sytuacji czujnik chemiczny można użyć w pomiarach bezpośrednich bez konieczności przygotowania próbki, a sam czujnik nie wpływa w żaden sposób na próbkę.
-
Improved Lead Sensing Using a Solid-Contact Ion-Selective Electrode with Polymeric Membrane Modified with Carbon Nanofibers and Ionic Liquid Nanocomposite
Publikacja -
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublikacjaThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publikacja -
Nanocomposite of copper oxide nanoparticles and multi-walled carbon nanotubes as a solid contact of a copper-sensitive ion-selective electrode: intermediate layer or membrane component–comparative studies
Publikacja -
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublikacjaLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Non-standard contact conditions in generalized continua: microblock contact model for a Cosserat body
PublikacjaGeneralized continuum theories involve non-standard boundary conditions that are associated with the additional kinematic variables introduced in those theories, e.g., higher gradients of the displacement field or additional kinematic degrees of freedom. Accordingly, formulation of a contact problem for such a continuum necessarily requires that adequate contact conditions are formulated for the additional kinematic variables and/or...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Improved performance of LaNi0.6Fe0.4O3 solid oxide fuel cell cathode by application of a thin interface cathode functional layer
PublikacjaIn this work, novel functional layers were prepared by a low temperature spray pyrolysis method on the oxygen side of the solid oxide cells. Thin layers of Ce0.8Gd0.2O2 and LaNi0.6Fe0.4O3 are prepared between the electrolyte and the porous oxygen electrode. Additionally the influence of the sprayed ceria barrier layer on the zirconia based electrolyte with the new layers is evaluated. Impedance spectroscopy results show improvement...
-
INFLUENCE OF SOLID PARTICLE CONTAMINATION ON THE WEAR PROCESS IN WATER LUBRICATED MARINE STRUT BEARINGS WITH NBR AND PTFE BUSHES
PublikacjaThis paper reports on a study of the influence of solid particle contamination on the wear process in water-lubricated slide bearings (steel-acrylonitrile-butadiene rubber (NBR) and steel- polytetrafluoroethylene (PTFE)). To compare the wear of the shaft journal and bushes (NBR and PTFE) when lubricated with fresh water and contaminated water, an experiment was carried out to identify key factors that influence the state of wear...
-
The effect of surfactants mixtures composition on wetting of different solid materials
PublikacjaThe wetting properties of surfactants mixtures were investigated. Three types of compounds were used: nonionic gemini α, α'-[2,4,7,9-tetramethyl-5-decyne-4,7-diyl]bis[ω-hydroxyl-olioxyethylene] (S-10), anionic sodium dodecyl sulphates (SDS) and cationic dodecyl trimethyl ammonium bromide (DTAB). The materials used in wetting experiments were steel and methyl polymethacrylate. These materials differ...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublikacjaHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
The Influence of Impact Velocity on Stresses and Failure of S355j2 Steel Under Slurry Erosion Conditions
PublikacjaThe purpose of this work was to determine the essence of the influence of the impact velocity (5, 7, and 9 m/s) on Hertzian stresses and the erosion mechanism of ferritic-pearlitic S355J2 steel. The investigations were carried out using a slurry pot tester. S355J2 steel showed a strong sensitivity to changes in impact velocity. A significant increase in erosion rate was observed at a velocity of 9 m/s. This increase was 5-fold...
-
Investigation of thin perovskite layers between cathode and doped ceria used as buffer layer in solid oxide fuel cells
PublikacjaIn this paper, thin perovskite layers between cathode material of solid oxide fuel cells and gadolinia-doped ceria buffer layer are investigated. Thin layers made of LaNi0.6Fe0.4O3-δ (LNF), La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF), or SrTi0.65Fe0.35O3-δ (STF) were symmetrically deposited by spin coating method from metallo-organic polymer precursors on a Ce0.8Gd0.2O2-δ (CGO) substrate. Porous and about 40-μm-thick LNF cathodes were deposited...
-
Manganese–Cobalt Based Spinel Coatings Processed by Electrophoretic Deposition Method: The Influence of Sintering on Degradation Issues of Solid Oxide Cell Oxygen Electrodes at 750 °C
PublikacjaThis paper seeks to examine how the Mn–Co spinel interconnect coating microstructure can influence Cr contamination in an oxygen electrode of intermediate temperature solid oxide cells, at an operating temperature of 750 °C. A Mn–Co spinel coating is processed on Crofer 22 APU substrates by electrophoretic deposition, and subsequently sintered, following both the one-step and two-step sintering, in order to obtain significantly...
-
Analysis of Ceramic Elements with Ring-Crack Defects in Lubricated Rolling Contact
PublikacjaThe properties of ceramics, specifically low density, high hardness, high temperature capability and low coefficient of thermal expansion are of most interest to rolling element manufacturers. Surface ring cracks on lubricating rolling contact fatigue failure has been studied using numerical fracture analysis. Such cracks are very often found on ceramic bearing balls and decrease fatigue life rapidly. The numerical calculations...
-
Improvement of Oxygen Electrode Performance of Intermediate Temperature Solid Oxide Cells by Spray Pyrolysis Deposited Active Layers
PublikacjaIntermediate temperature solid oxide fuel cells oxygen electrodes are modified by active interfacial layers. Spray pyrolysis is used to produce thin (≈500 nm) layers of mixed ionic and electronic conductors: Sm0.5Sr0.5CoO3−δ (SSC), La0.6Sr0.4CoO3−δ (LSC), La0.6Sr0.4Co0.2Fe0.8O3−δ (LSCF), and Pr6O11 (PrOx) on the electrode–electrolyte interface. The influence of the annealing temperature on the electrode polarization (area specific...
-
Impact analysis of surface roughness of the plate-plate measuring system on resistance torque in interaction with MR fluid
PublikacjaMagnetorheological (MR) fluids are complex suspensions of magnetic particles in a non-magnetic carrier fluid. They exhibit ‘smart’ properties that enable them to change their rheological parameters in response to a change in the external magnetic field applied. This behavior is used in some engineering solutions, e.g. MR clutches or brakes. For such systems to work correctly, the resistance torque achieved by contact with the...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublikacjaThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Kazimierz Darowicki prof. dr hab. inż.
OsobyStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublikacjaThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
A model of liquid film breakdown formed due to impingement of a two-phase jet on a horizontal surface
PublikacjaThe present work aims to provide an explanation to the phenomenon of breakdown of the thin liquid film created by impinging two-phase, liquid-gas jet. Existing in the literature models describe merely thebreakdown of single phase liquid films. The model presented here is based on examination of mass and energy equations under the applied criterion of the minimum of total energy. That allows to determinethe minimum thickness of...
-
Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems
PublikacjaThis paper presents research on the bending properties of 3 × 7 19-mm wire rope commonly used in road cable barriers. A total of 19 experimental tests were conducted. In addition, two nonlinear 3D numerical models of the wire rope using beam and solid finite elements were developed. Based on these models, four numerical simulations were carried out. The numerical results were validated against the experimental ones and a very good...
-
Bisphenols and their derivatives in baby diaper samples.
PublikacjaMany common products contain and leach hazardous chemicals, including endocrine-disrupting chemicals such as bisphenols that are harmful to human health. For toddlers, this dangerousness is higher because of their not fully developed detoxification system. Due to this, bisphenols content in products such as baby diapers, should be monitored. Baby diapers not only remain in close contact with the skin, but are also used from the...
-
Imaging of graphene surface by means of tapping mode AFM
Dane BadawczeGraphene [1] is a material consisting of carbon planes with a hexagonal structure. One of the facts of interest from a purely scientific point of view is the very high mobility of electrons in the described material, allowing the study of relativistic effects inside a solid sample. Other features, such as bactericidal activity, make graphene an interesting...
-
Utilizing Cement Kiln Dust as an Efficient Adsorbent for Heavy Metal Removal in Wastewater Treatment
PublikacjaCement kiln dust (CKD), a by-product of cement manufacturing, has been largely underutilized despite its potential as an eco-friendly adsorbent for wastewater treatment. This study addresses the knowledge gap regarding CKD’s effectiveness in removing heavy metals from wastewater residuals. A comprehensive experimental program was conducted to optimize key parameters such as the pH (6–9), contact time, sorbent dosage, and initial heavy...
-
Problems of Measuring Gas Content in Oil in a Two-Phase Flow: A Review
PublikacjaIn view of the necessity of measuring the air content in oil in two-phase flows in the context of general industry, a review of the most popular methods of measuring the air content in oil was carried out. This review includes an assessment of their advantages and disadvantages and of whether they meet criteria such as the degree of filling, the size and number of bubbles, verification, the absence of additional pressure drops,...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublikacjaNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
Exposure scenario and risk assessment of infants and newborns to bisphenols and their derivatives from diapers
PublikacjaNewborns and infants are more sensitive to harmful compounds such as bisphenols and their derivatives because of their not fully developed detoxification mechanism. Exposure to these substances can lead to developmental problems and health consequences in adulthood. Since disposable baby diapers are used from the first days of life and remain in contact with the baby skin, it seems important to monitor the levels of endocrine disrupting chemicals...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublikacjaGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Badania stabilności chemicznej kompozytowego elektrolitu 3-YSZ-Al2O3 w stosunku do materiałów elektrodowych do zastosowania w średniotemperaturowych ogniwach paliwowych
PublikacjaJednym z podstawowych wymogów stawianych mate- riałom na elektrolity do średniotemperaturowych ogniw paliwowych IT-SOFC (ang. intermediate-temperature solid oxide fuel cells) jest ich kompatybilność chemiczna z elektrodami w temperaturach zarówno eksploatacji, jak i wytwarzania ogniw. W celu sprawdzenia, czy badany w pracy kompozytowy elektrolit o osnowie z częściowo stabilizowanego ditlenku cyrkonu i z wtrąceniami tlenku glinu...
-
Photoelectrochemical properties of BIMEVOX (ME=Cu, Zn, Mn) electrodes in contact with aqueous electrolyte
PublikacjaLayered oxide Bi4O2O11 and mixed oxides of bismuth, vanadium and a third metal (ME = Cu, Zn, Mn) were synthesized and characterized using XRD, Raman and SEM. The energy band gap (Eg) of samples determined using UV–VIS reflectance spectra equals to 2.46, 2.34, 2.27 and 2.18 eV for Bi4V2O11, BICUVOX (Bi2V1 − xCuxO5.5 − 3x/2), BIZNVOX (Bi2V1 − xZnxO5.5 − 3x/2) and BIMNVOX (Bi2V1 − xMnxO5.5 − x/2) (x = 0.1), respectively. Open circuit...
-
Portable raman spectrometer for maritime security applications
PublikacjaThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
AFM investigation of electrode fabricated by 3D printing
Dane Badawcze3D printing, also known as additive manufacturing, has enjoyed great interest in recent years due to the versatility of this method of producing various shapes and details. Due to the possibility of precise control of the shape and composition of the printed elements, the discussed technique can be widely used in electrochemistry, including electrochemical...
-
Does the low optical band gap of yellow Bi3YO6 guarantee the photocatalytical activity under visible light illumination?
PublikacjaBi3YO6, which is known as an ionic conductor, was tested here as an electrode and photoanode in contact with aqueous electrolytes. Bi3YO6 was deposited onto the Pt substrate and the such prepared electrode was polarized in various aqueous electrolytes. The optical energy band gap of the material equal to 1.89 eV was determined using the Kubelka-Munk function resulting from the UV-Vis spectrum (allowed indirect transition) and also...