Filtry
wszystkich: 13561
-
Katalog
- Publikacje 9514 wyników po odfiltrowaniu
- Czasopisma 645 wyników po odfiltrowaniu
- Konferencje 267 wyników po odfiltrowaniu
- Osoby 517 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 25 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 3 wyników po odfiltrowaniu
- Kursy Online 362 wyników po odfiltrowaniu
- Wydarzenia 14 wyników po odfiltrowaniu
- Dane Badawcze 2212 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: VOLTAGE MEASUREMENT , TOPOLOGY , CONTROL SYSTEMS , VOLTAGE CONTROL , FIELD PROGRAMMABLE GATE ARRAYS , CAPACITORS , PULSE WIDTH MODULATION
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Measuring Pulse Rate with a Webcam
PublikacjaIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Measurement of Unwanted Thought Suppression Strategies with the Thought Control Questionnaire in the General Polish Population: A Confirmatory Factor Analysis and Validation
Publikacja -
GAS SENSORS WITH TEMPERATURE MODULATION – AN OVERVIEW
PublikacjaAlthough different methods of improving semiconductor gas sensor properties have been proposed, a technique involving temperature modulation seems to be the most promising. Semiconductor gas sensors working with modulated temperature can be more stable and are more selective comparing with sensor working at one temperature. In this paper, various approaches to temperature modulation are reviewed.
-
Electric field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain electric field maps created on based measurements...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublikacjaIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Example applications of control charts as a quality tool for statistical process control in a small manufacturing company
PublikacjaPraca zawiera przykład wdrożenia kart kontrolnych w małym zakładzie produkcyjnym zajmującym się wytwarzaniem komponentów z blach. Pokazano jak z zastosowaniem dostępnego pakietu biurowego, można stworzyć statystyczną kontrolę procesu(SPC)w małej firmie. Artykuł zawiera wyniki z przykładowych analizowanych procesów.
-
Softly switched model predictive control for control of integratedwastewater treatment system at medium time scale.
PublikacjaW przypadku gdy system jest sterowany za pomocą jednej, uniwersalnej strategii sterowania w pełnym zakresie jego obciążeń, powstają poważne trudności w znalezieniu optymalnego sterowania. W celu jak najlepszego dopasowania strategii sterowania do panujący warunków, zdefiniowano trzy stany operacyjne: normalny, zakłóceniowy oraz awaryjny. Dla tych stanów zaprojektowano odpowiednie strategie sterowania. W związku z tym pojawia się...
-
Indirect adaptive controller based on a self-structuring fuzzy system for nonlinear modeling and control
PublikacjaIn this paper, a unified nonlinear modeling and control scheme is presented. A self-structuring Takagi-Sugeno (T-S) fuzzymodel is used to approximate the unknown nonlinear plant based on I/O data collected on-line. Both the structure and theparameters of the T-S fuzzy model are updated by an on-line clustering method and a recursive least squares estimation(RLSE) algorithm. The rules of the fuzzy model can be added, replaced or...
-
Magnetic field maps of an astable multivibrator in frequency range from 100 kHz to 50 MHz
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
The Matter of Decision-Making Control Over Operation Processes of Marine Power Plant Systems with the Use of their Models in the form of Semi-Markov Decision-Making Processes
PublikacjaThe article presents the possibility to control the real operation process of an arbitrary device installed in the marine power plant based on the four-state semi-Markov process, being the model of the process, which describes the transition process of operational states of the device and the transition process of its technical states. All these states are precisely defined for the ship main engine (SG). A hypothesis is proposed...
-
ANALYSIS OF IMPACT of SHIP model parameters on changes of control quality index in ship dynamic positioning system
PublikacjaIn this work there is presented an analysis of impact of ship model parameters on changes of control quality index in a ship dynamic positioning system designed with the use of a backstepping adaptive controller. Assessment of the impact of ship model parameters was performed on the basis of Pareto-Lorentz curves and ABC method in order to determine sets of the parameters which have either crucial, moderate or low impact on objective...
-
Testing of Technical Fabrics under Fast Camera Control
PublikacjaThe dynamic development of measurement and recording techniques has been changing the way one conceives material strength. In this study, two different methods of evaluating the strength of fabrics are compared. The first is the typical and commonly used technique based on the use of a testing machine. The second method uses the so-called “fast camera” to monitor the entire process of the destruction of a fabric sample and analyse...
-
Topology Discovery of Hierarchical Ethernet LANs without SNMP support
PublikacjaThis paper presents an algorithm that allows for discovery of layer-2 hierarchical Ethernet network topology using agents running on selected end nodes. No SNMP, MIB, hardware, firmware, or operating system-level software modification is required. The method is based on transmission of customized Ethernet frames among installed software agents. It can be used to discover the topology of LAN or one VLAN segment as long as no MAC...
-
Topology recognition and leader election in colored networks
PublikacjaTopology recognition and leader election are fundamental tasks in distributed computing in networks. The first of them requires each node to find a labeled isomorphic copy of the network, while the result of the second one consists in a single node adopting the label 1 (leader), with all other nodes adopting the label 0 and learning a path to the leader. We consider both these problems in networks whose nodes are equipped with...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Networked Object Monitor - A distributed system for monitoring, diagnostics and control of complex industrial facilities
PublikacjaRozwój mobilności i technologii internetowych, a także globalizacji gospodarki światowej, uwzględniający kluczowe aspekty zarządzania przepływem informacji, otworzył zupełnie nowe możliwości opracowywania i konstruowania innowacyjnych rozwiązań technicznych. Z taką myślą powstał prototyp Sieciowego Monitora Obiektu, aplikacji umożliwiającej nie tylko ciągłą kontrolę parametrów obiektów przemysłowych i biznesowych, ale również zarządzanie...
-
Human subarachnoid space width oscillations in the resting state
PublikacjaAbnormal cerebrospinal fluid (CSF) pulsatility has been implicated in patients suffering from various diseases, including multiple sclerosis and hypertension. CSF pulsatility results in subarachnoid space (SAS) width changes, which can be measured with near-infrared transillumination backscattering sounding (NIR-T/BSS). The aim of this study was to combine NIR-T/BSS and wavelet analysis methods to characterise the dynamics of the...
-
Surface quality control of a thin SiN layer by optical measurements
PublikacjaFiber optic interferometers have a wide range of applications, including biological and chemical measurements. Nevertheless, in the case of a reflective interferometer setup, standard silver mirrors cannot be used in every measurement, due to their chemical activity. This work investigates the surface quality of a thin optical layer of silicon nitride (SiN), which can serve as an alternative material for silver mirrors. We present...
-
TOPOLOGY
Czasopisma -
Photovoltaic Maximum Power Point Technique based on Incremental Conductance (INCON) control algorithm
PublikacjaMaximum output power status can significantly improve the deployment rate of solar energy system. In order to get the maximum power output, issue of tracking maximum power point (MPP), reduced harmonics around MPP and improve efficiency of the solar power energy system, this paper presents the improved maximum power point tracking (MPPT) control...
-
Multi-DBD plasma actuator for flow separation control around NACA 0012 and NACA 0015 airfoil models
PublikacjaIn this paper application of innovative multi-DBD plasma actuator for flow separation control is presented. The influence of the airflowgenerated by this actuator on the flow around NACA 0012 and NACA 0015 airfoil models was investigated. The results obtained from 2D PIVmeasurements showed that the multi-DBD actuator with floating interelectrode can be attractive for leading and trailing edge separation control.
-
CRVG - a new model for wireless networks topology generation
PublikacjaThis paper presents a new model of wireless network topology generator. Its main advantage is the possibility of relatively sparse networks generation. Because no iteration is needed, the model can be used for massive generation of networks for testing. The topological properties of produced graphs place them in the class of scale free networks, resembling real ones.
-
Buckling and shape control of prestressable trusses using optimum number of actuators
PublikacjaThis paper describes a method to control the nodal displacement of prestressable truss structures within the desired domains. At the same time, the stress in all members is unleashed to take any value between the allowable tensile stress and critical buckling stress. The shape and stresses are controlled by actuating the most active members. The technique considers the members’ initial crookedness, residual stresses, and slenderness...
-
Fully Separated Flow Control Using DBD Plasma Actuators Located at the Leading Edge of an Airfoil
PublikacjaIn the framework of the PLASMAERO European project, experiments were conducted to investigate the authority of surface DBD plasma actuators to alter a fully separated flow around an airfoil in order to improve its aerodynamic performances in its natural stall regime. In this paper, unsteady excitation control is more specifically investigated. The key control parameter studied here is the burst frequency which periodically imposes...
-
The QDMC Model Predictive Controller for the Nuclear Power Plant Steam Turbine Control
PublikacjaThere are typically two main control loops with PI con trollers operating at each turbo-generator set. In this paper a model predictive controller QDMC for the steam turbine is proposed - instead of a typical PI controller. The QDMC controller utilize a step-response model for the controlled system. This model parameters are determined, based on the simplified and linear model of turbo-generator set, which parameters are identified...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Event-Triggered Communication in Cooperative, Adaptive Model Predictive Control of a Nuclear Power Plant’s Turbo–Generator Set
PublikacjaThis paper discusses the issue of optimizing the communication between the components of a cooperating control system formed by a pair of MPC controllers of a nuclear power plant turbine set using online recursive least squares identification. It is proposed to use event-triggered communication, i.e., sending information only at selected time instants, as opposed to the standard approach where communication is triggered by time...
-
Rivers Try Harder. Reversed “Differential Erosion” as Geological Control of Flood in the Large Fluvial Systems in Poland
Publikacja -
Impact of Low Switching-to-Fundamental Frequency Ratio on Predictive Current Control of PMSM: A simulation study
PublikacjaPredictive current control algorithms for permanent magnet synchronous (PMSM) drives rely on an assumption that within short intervals motor currents can be approximated with linear functions. This approximation may result either from discretizing the motor model or from simplifications applied to the continuous-time model. As the linear current approximation has been recognized as inaccurate in case when the drive operates with...
-
Raman miniaturised system for field applications
PublikacjaRaman spectroscopy is a powerful and versatile research technique with a broad range of potential applications, which includes laboratory studies, on-line industrial process monitoring and field measurements. Scope of the field applications includes environment monitoring, detection of dangerous or prohibited materials and rapid identification of unknown samples. It stimulates development of dedicated Raman measurement equipment...