Wyniki wyszukiwania dla: electrocatalytic gas sensor
-
Electrocatalytic gas sensor with reference layer
PublikacjaIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Hydrogen sulphide electrocatalytic gas sensor
PublikacjaIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Electrocatalytic Gas Sensor with Reference Layer
PublikacjaThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Electrocatalytic gas sensor response analysis
PublikacjaW pracy przedstawiono i porównano metody analizy odpowiedzi elektrokatalitycznych czujników gazów toksycznych. Opisane metody pozwalają na ekstrakcje z odpowiediz czujników informacji o rodzaju gazu oraz o jego stężeniu.
-
Staircase Voltammetry Application to Electrocatalytic Gas Sensor
PublikacjaW pracy przedstawiono wyniki badań czujnika elektrokatalicznego pobudzanego sygnałem schodkowym w różnych mieszaninach gazowych .
-
Lisicon solid electrolyte electrocatalytic gas sensor
PublikacjaW artykule przedstawiono sposób przygotowania oraz wyniki badań elektrokatalitycznego czujnika gazów na bazie Lisicon'owego elektrolitu stałego. Przedstawiono charakterystyki czujnika w mieszaninie dwutlenku azotu oraz dwutlenku siarki w syntetycznym powietrzu. Odpowiedź I-V czujnika w unikalny sposób zależy od stężenia i rodzaju gazu w otoczeniu czujnika.
-
Features extraction from the electrocatalytic gas sensor responses
PublikacjaOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublikacjaIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublikacjaProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Electrocatalytic gas sensors based on Nasicon and Lisicon
PublikacjaW pracy przedstawiono porównanie właściwości czujników elektrokatalitycznych na bazie Nasiconu i Lisiconu. Czujniki zostały przygotowane w technologii ceramicznej. Przedstawiono wyniki badań czujników w obecności mieszaniny dwutlenku azotu, dwutlenku siarki i syntetycznego powietrza.
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Sensitivity to nitrogen dioxide of electrocatalytic gas sensor based on NASICON
PublikacjaW pracy przedstawiono wyniki badań czujnika elektrokatalitycznego na bazie NASICONu.
-
An application of advanced data processing methods to response analysis of electrocatalytic gas sensor
PublikacjaPrzedstawiono stosowane dotychczas oraz zaproponowano nowe metody analizy odpowiedzi czujników elektrokatalitycznych. Porównano ich właściwości.
-
Efficiency of linear and non-linear classifiers for gas identification from electrocatalytic gas sensor
PublikacjaElectrocatalytic gas sensors belong to the family of electrochemical solid state sensors. Their responses are acquired in the form of I-V plots as a result of application of cyclic voltammetry technique. In order to obtain information about the type of measured gas the multivariate data analysis and pattern classification techniques can be employed. However, there is a lack of information in literature about application of such...
-
Electrocatalytic gas sensor with non-triangular excitation = Czujnik elektrokatalityczny z pobudzeniem innym niż trójkątne
PublikacjaElektrokatalityczny czujnik gazu pracuje w trybie woltamperometrycznym. Pobudzony jest zmieniającym się napięciem przy jednoczesnym pomiarze prądowej odpowiedzi czujnika. Charakterystyka prądowo-napięciowa ma unikalny kształt, uzależniony od stężenia i rodzaju gazów w otoczeniu czujnika. Jako pobudzenie zazwyczaj stosowane jest napięcie liniowo narastające w zakresie od 5 V do -5 V napięcie o symetrycznym, trójkątnym kształcie....
-
The influence of electrocatalytic toxic gas sensor construction on its performance
PublikacjaW pracy przedstawiono porównanie właściwości elektrokatalitycznych czujników gazów przygotowanych na bazie różnych elektrolitów stałych oraz wykonanych w różnych technologiach.
-
Electrocatalytic nitrogen dioxide sensor.
PublikacjaOpisano konstrukcję i właściwości elektrokatalitycznego czujnika gazów na bazie domieszkowanego samarem tlenku ceru. Pomiary przeprowadzono w mieszaninie syntetycznego powietrza i dwutlenku azotu. Kształt odpowiedzi prądowo - napięciowej zależy od stężenia NO2.
-
electrocatalytic sensor based on nasicon with auxiliary layer
PublikacjaW pracy przedstawiono wyniki badań czujników elektrokatalitycznych z dodatkową warstwą. Właściwości takiego czujnika porównano z czujnikiem o tradycyjnej budowie.
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublikacjaA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
TOXIC GASES IDENTIFICATION USING SINGLE ELECTROCATALYTIC SENSOR RESPONSES AND ARTIFICIAL NEURAL NETWORK
PublikacjaThe need for precise detection of toxic gases drives development of new gas sensors structures and methods of processing the output signals from the sensors. In literature, artificial neural networks are considered as one of the most effective tool for the analysis of gas sensors or sensors arrays responses. In this paper a method of toxic gas components identification using a electrocatalytic gas sensor as a detector and an artificial...
-
Polypyrrole based gas sensor for ammonia detection
PublikacjaThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Influence of operation temperature instability on gas sensor performance
PublikacjaGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
Electrocatalytic sensor based on Nasicon with auxiliary layer = Czujnik elektrokataliczny na bazie Nasiconu z warstwą dodatkową
PublikacjaW pracy zostały przedstawione wyniki pomiarów czujnika na bazie Nasiconu pracującego w trybie elektrokatalitycznym. Czujniki takie pobudzane są zmieniającym się napięciem przy jednoczesnym pomiarze odpowiedzi prądowej. Przygotowano czujniki ceramiczne o dwóch różnych typów. Pierwszy z nich to czujnik posiadający dwie identyczne elektrody złote, pomiędzy którymi znajduje się elektrolit stały. Drugi czujnik posiada złote elektrody...
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublikacjaThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublikacjaScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublikacjaIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublikacjaThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublikacjaThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublikacjaThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublikacjaSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublikacjaWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublikacjaIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Properties of a lithium solid electrolyte gas sensor based on reaction kinetics
PublikacjaW artykule przedstawiono zasadę działania, budowę i właściwości czujnika gazu na bazie elektrolitu stałego z mobilnymi jonami litu. Czujnik został przygotowany w technologii grubowarstwowej. Przedstawiono wyniki badań czujnika w mieszaninach gazów toksycznych.
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublikacjaA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublikacjaThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Nickel Oxide Thin Film Sensor for Fluctuation-Enhanced Gas Sensing of Formaldehyde
PublikacjaNanocrystalline nickel-oxide-based thin films were prepared by advanced reactive gas deposition, and the response of these films to formaldehyde was studied by fluctuationenhanced sensing. Morphological and structural analyses showed porous deposits of nickel oxide particles with face-centered cubic structure. Resistance fluctuations were measured upon exposure to ethanol, formaldehyde and methane at 200 °C. Power density spectra...
-
Monitoring of absorptive model biogas purification process using sensor matrices and gas chromatography
PublikacjaThis study examined the process of purifying model biogas using a new type of absorbent based on a Deep Eutectic Solvent (DES) and a commercially available absorbent (Genosorb) to remove acetone, toluene, and cyclohexane. The main aim of the research was to control the purification efficiency using gas chromatography (GC) and an alternative method based on sensor matrices (SM). As a result of comparing the multidimensional SM signals...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Application of Multiplicative Drift Correction and Component Correction methods on simulated gas sensor array responses
PublikacjaSensor response drift is one of the most challenging problems in gas-analyzing systems. Such systems, commonly called electronic noses, are expected to be reliable and reproducible in the long term. Due to the drift phenomena, electronic noses usability is limited to the relatively short period of time, and frequent recalibrations of device are required. Because it is very hard to fabricate sensors without drift, this phenomenon...
-
Influence of Analyte Flow Rate on Signal and Response Time of the Amperometric Gas Sensor with Nafion Membrane
PublikacjaW publikacji przedstawiono rezultaty badań nad wpływem zmian objętościowego natężenia przepływu gazu na sygnał i czas odpowiedzi prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości czujników różniących się materiałem elektrody pracującej oraz składem roztworu elektrolitu wewnętrznego. Zastosowano elektrody pracujące wykonane z napylonych próżniowo na powierzchnię membrany nafionowej złota i platyny....
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublikacjaThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublikacjaThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublikacjaThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublikacjaIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
System setup and software for cyclic, staircase and square wave voltammetry measurements
PublikacjaHardware dedicated for electrochemical measurement sometimes does not allow performing certain voltammetry experiments. Staircase and square wave voltammetry, techniques which have many advantages comparing with standard voltammetric techniques, are rarely implemented in software controlling electrochemical measuring equipment. These methods, however, can be relatively easy realized with some addition...
-
Electrical responses of nanoporous NiO films for light-activated nitrogen dioxide and acetone gas sensing
Dane BadawczeThe chemoresistive sensor response of nanoporous NiO films prepared by advanced gas deposition was investigated with and without simultaneous light irradiation, to detect nitrogen dioxide and acetone gases. The presented data show electrical responses presented as sensor resistance or relative changes in sensor resistance under selected environment...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Dane BadawczeNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
Electrical responses of nanostructured ZrS3 as field-effect transistor for nitrogen dioxide, ethanol, and acetone detection enhanced by visible light
Dane BadawczeSmall-area layers of nanostructured ZrS3 were fabricated and measured in the field-effect transistor configuration. Irradiation with visible light enabled generating photocurrent and increasing the sensitivity to selected ambient gases: nitrogen dioxide, ethanol, and acetone. The data set consists of electrical responses (current vs. voltage characteristics...