Wyniki wyszukiwania dla: intra-cardiac balloons
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublikacjaThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...
-
Effect of Vascular Lumen Reduction on the Performance and Energy Consumption of an Innovative Implantable LVAD
PublikacjaThis paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device). It details the pressures in the individual cardiac chambers as a function of device frequency. In addition, mass flow rates and energy consumption of the device are examined, varying with lumen reduction and operating frequency. While the lumen reduction of the...
-
Bioactive polyurethanes applied as a surgical implants
PublikacjaSynthetic materials are applied in many branches of the industry, i.a. in medicine as a casing of apparatus, elements of artificial organs (hearts, blood vessels), catheters, wound healings, intra aortic balloons, mammary implants to mention but a few. Polymeric material used in such applications must be distinguished by a good biocompatybility. Since many years extensive research are employed to develop a new polymers that can...
-
Emissions and toxic units of solvent, monomer and additive residues released to gaseous phase from latex balloons
PublikacjaThis study describes the VOCs emissions from commercially available latex balloons. Nine compounds are determined to be emitted from 13 types of balloons of different colors and imprints in 30 and 60°C. The average values of total volatile organic compounds (TVOCs) emitted from studied samples ranged from 0.054 up to 7.18 μg∙g-1 and from 0.27 up to 36.13 μg∙g-1 for 30oC and 60oC, respectively. The dataset is treated with principal...
-
Mariusz Kaczmarek dr hab. inż.
OsobyReceived M.Sc., Eng. in Electronics in 1995 from Gdansk University of Technology, Ph.D. in Medical Electronics in 2003 and habilitation in Biocybernetics and Biomedical Engineering in 2017. He was an investigator in about 13 projects receiving a number of awards, including four best papers, practical innovations (7 medals and awards) and also the Andronicos G. Kantsios Award and Siemens Award. Main research activities: the issues...
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublikacjaCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Electrically Conductive Carbon‐based (Bio)‐nanomaterials for Cardiac Tissue Engineering
PublikacjaA proper self-regenerating capability is lacking in human cardiac tissue which along with the alarming rate of deaths associated with cardiovascular disorders makes tissue engineering critical. Novel approaches are now being investigated in order to speedily overcome the challenges in this path. Tissue engineering has been revolutionized by the advent of nanomaterials, and later by the application of carbon-based nanomaterials...
-
Artificial Intelligence for Wireless Avionics Intra-Communications
PublikacjaThis chapter presents a summary of the description and preliminary results of the use case related to the implementation of artificial intelligence tools in the emerging technology called wireless avionics intra-communications (WAICs). WAICs aims to replace some of the cable buses of modern aircraft. This replacement of infrastructure leads to: (1) complexity reduction of future airplanes, (2) creation of innovative services where...
-
Network Approach to Increments of RR-intervals for Visualization of Dynamics of Cardiac Regulation
PublikacjaThe transition network for RR -increments is pre- sented in a directed and weighted graph, with vertices represent- ing RR -increments and edges corresponding to the order in a sequence of increments. The adjacency matrix and the transition matrix of this network provide a graphical tool which could be useful in the assessment of cardiac regulation. As an example, the method is applied in detecting differences between diurnal activity...
-
The role of trade in intra industry productivity growth - the case of old and new European Union countries.
PublikacjaThe purpose of this paper is to evaluate the role of trade in productivity growth in a sample of 30 sectors in 25 EU countries in the period of rapid East–West integration (1995–2007). Shift-share analysis is used to show that changes in value added per hour worked in these countries appear to be mainly due to positive developments (rising productivity) within single industries and only to a lower extent result from a shift towards...
-
Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
PublikacjaPial artery adjustments to changes in blood pressure (BP)may last only seconds in humans. Using a novelmethod called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of...
-
Coupling of Blood Pressure and Subarachnoid Space Oscillations at Cardiac Frequency Evoked by Handgrip and Cold Tests: A Bispectral Analysis
PublikacjaThe aim of the study was to assess blood pressure–subarachnoid space (BP–SAS) width coupling properties using time–frequency bispectral analysis based on wavelet transforms during handgrip and cold tests. The experiments were performed on a group of 16 healthy subjects (F/M; 7/9) of the mean age 27.2 ± 6.8 years and body mass index of 23.8 ± 4.1 kg/m². The sequence of challenges was first handgrip and then cold test. The handgrip...
-
Full-field in vivo experimental study of the strains of a breathing human abdominal wall with intra-abdominal pressure variation
PublikacjaThe presented study aims to assess the mechanical behaviour of the anterior abdominal wall based on an in vivo experiment on humans. Full-field measurement of abdominal wall displacement during changes of intra-abdominal pressure is performed using a digital image correlation (DIC) system. Continuous measurement in time enables the observation of changes in the strain field during breathing. The understanding of the mechanical...
-
Artificial intelligence models in prediction of response to cardiac resynchronization therapy: a systematic review
PublikacjaThe aim of the presented review is to summarize the literature data on the accuracy and clinical applicability of artificial intelligence (AI) models as a valuable alternative to the current guidelines in predicting cardiac resynchronization therapy (CRT) response and phenotyping of patients eligible for CRT implantation. This systematic review was performed...
-
New Low-Cost Video Camera Pointing Mechanism for Stratospheric Balloons: Design and Operational Tests
Publikacja -
Sympathetic Rhythmicity in Cardiac Transplant Recipients
Publikacja -
Multislice CT in functional cardiac exploration.
PublikacjaArtykuł przedstawia analizę oraz omówienie wykonanych badań w zastosowaniu tomografia wielorzędowej w diagnostyce czynnościowej serca. Pokazano zarówno aspekty technicznej metody jak i możliwości zastosowań medycznych.
-
Intra-provincial inequalities and economic growth in China
Publikacja -
Cohort Study About Intra-Operative Neuromonitoring
Publikacja -
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublikacjaThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublikacjaThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Visually validated semi-automatic high-frequency oscillation detection aides the delineation of epileptogenic regions during intra-operative electrocorticography
PublikacjaOBJECTIVE: To test the utility of a novel semi-automated method for detecting, validating, and quantifying high-frequency oscillations (HFOs): ripples (80-200 Hz) and fast ripples (200-600 Hz) in intra-operative electrocorticography (ECoG) recordings. METHODS: Sixteen adult patients with temporal lobe epilepsy (TLE) had intra-operative ECoG recordings at the time of resection. The computer-annotated ECoG recordings were visually...
-
Annals of Cardiac Anaesthesia
Czasopisma -
Acute Cardiac Care
Czasopisma -
Cardiac Electrophysiology Clinics
Czasopisma -
JOURNAL OF CARDIAC FAILURE
Czasopisma -
JOURNAL OF CARDIAC SURGERY
Czasopisma -
Mechanical circulatory support. An expert opinion of the Association of Intensive Cardiac Care and the Association of Cardiovascular Interventions of the Polish Cardiac Society
Publikacja -
Hydrogels Based on Natural Polymers for Cardiac Applications
PublikacjaIn this work agar- and borax-based hydrogels with and without the addition of poly(vinyl alcohol) (PVA) at different concentrations were synthesized. Hydrogels were modified by the same amount of acetylsalicylic acid (ASA) which exhibits antithrombotic properties. The effect of modification by ASA on the properties of hydrogels was analyzed.
-
Enhancing the Cleveland Clinic Score in cardiac surgery
Publikacja -
Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
PublikacjaThe aim of this study was to test the accuracy of ultrasonography performed by gynecological oncologists for the preoperative assessment of epithelial ovarian cancer (EOC) spread in the pelvis and abdominal cavity. A prospective, observational cohort study was performed at a single tertiary cancer care unit. Patients with suspected EOC were recruited and underwent comprehensive transvaginal and abdominal ultrasonography performed...
-
Rapid cardiac ischemia detection with an epicardial graphene probe
Publikacja -
A scale with ECG measurements capability for home cardiac monitoring
PublikacjaPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublikacjaIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Electromagnetic Field Associated With Dermoscope Magnets May Affect the Safety of Cardiac Implanted Electronic Devices Patients
PublikacjaDermoscopy is currently used as an auxiliary tool in general dermatology. Since some commercially available dermoscopes have built-in magnets, electromagnetic interference (EMI) may occur when examining cardiac implantable electronic devices (CIED) patients. The aim of the study was to create maps of electromagnetic fields defining a safe distance in terms of EMI. The study was performed in laboratory conditions using measuring...
-
Paraesophageal Hernia Repair Followed by Cardiac Tamponade Caused by ProTacks
Publikacja -
Better prognostication after intensive care unit cardiac arrest
Publikacja -
Intra-operative biopsy in chronic sinusitis detects pathogenic Escherichia coli that carry fimG/H, fyuA and agn43 genes coding biofilm formation
PublikacjaThe aim of this study was to investigate whether or not surgical biopsy of sinus tissue in chronic sinusitis, not responsive to treatment, would detect E. coli. We intended to evaluate E. coli virulence genes, therefore dispute the causal role of such an unusual microorganism in chronic sinusitis, as well as consider effective pathogen-targeted therapy. Patients with E. coli isolated by intra-operative puncture biopsy were included...
-
Acute Effects of Ischemic Intra-Conditioning on 30 m Sprint Performance
Publikacja -
Vident-real: an intra-oral video dataset for multi-task learning
Dane BadawczeWe introduce Vident-real, a large dataset of 100 video sequences of intra-oral scenes from real conservative dental treatments performed at the Medical University of Gdańsk, Poland. The dataset can be used for multi-task learning methods including:
-
Pediatric Cardiac Surgery Annual
Czasopisma -
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY
Czasopisma -
Extracorporeal Cardiopulmonary Resuscitation—A Chance for Survival after Sudden Cardiac Arrest
Publikacja -
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublikacjaUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Intra- and intersubunit changes accompanying thermal activation of the HtrA2(Omi) protease homotrimer
Publikacja -
Impact of Ischemic Intra-Conditioning on Power Output and Bar Velocity of the Upper Limbs
Publikacja -
Modeling of Cardiac Component of Subarachnoid Space Changes in Apnoea Resulting as a Function of Blood Pressure and Blood Flow Parameters - Two Mechanizm of Regulation
PublikacjaExperiments were performed in a group of 19 healthy, non-smoking volunteers. The experiment consisted of three apnoeas, sequentially: 30 s apnoea, 60 s apnoea and maximal, that could be done, apnoea. The breath-hold was separated for 5 minutes rest. The following parameters were measured and obtained for further analysis: blood parameters, artery diameter of the internal carotid artery, end-tidal CO2 in expired air, the cardiac...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublikacjaIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Evaluation of cardiac muscle microvessel density in children diagnosed with cyanotic heart defects
Publikacja -
Post-Activation Performance Enhancement: Save Time With Active Intra-Complex Recovery Intervals
Publikacja