Filtry
wszystkich: 3380
-
Katalog
- Publikacje 1607 wyników po odfiltrowaniu
- Czasopisma 1 wyników po odfiltrowaniu
- Osoby 91 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Laboratoria 3 wyników po odfiltrowaniu
- Aparatura Badawcza 7 wyników po odfiltrowaniu
- Kursy Online 255 wyników po odfiltrowaniu
- Wydarzenia 58 wyników po odfiltrowaniu
- Dane Badawcze 1354 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: 915 MHZ
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...
-
Design of a Coplanar Waveguide-Fed Wideband Compact-Size Circularly Polarized Antenna and polarization-sense alteration
PublikacjaThis paper presents the design and validation of a geometrically simple circularly polarized(CP) structure featuring flat gain in the sub-6 GHz 5th generation spectrum. The proposed structure is based on coplanar-waveguide-fed, modified wide slot etched in the ground plane. For generating CP waves, the coplanar ground planes are designed with slight asymmetry in both the horizontal and vertical directions. Furthermore, the ground...
-
Linear impedance of 10Na2O–60P2O5–30CaO glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 10Na2O–60P2O5–30CaO glass was measured by impedance spectroscopy method.
-
Mikro system zasilania bezprzewodowego
PublikacjaWzrastająca na rynku liczba układów mikrokontrolerów o bardzo niskiej konsumpcji energii elektrycznej umożliwia budowę układów zasilania bezprzewodowego, opartych o układy zbierające energię elektryczną z różnych źródeł występujących w naszym otoczeniu. Obecnie powstające układy wytwarzające energie elektryczną korzystają z jej konwersji m.in. z następujących źródeł: promieniowania słonecznego, energii drgań i wibracji, występujących...
-
Sialadenoma papilliferum - Female, 15 - Tissue image [51707300212451]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, malignant - Male, 15 - Tissue image [7040347232568931]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021244141]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021242831]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021245161]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021249291]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroadenoma, NOS - Female, 15 - Tissue image [7060729599326481]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021244311]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021247011]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021249931]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, malignant - Male, 15 - Tissue image [5150730018703451]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroadenoma, NOS - Female, 15 - Tissue image [7060729599328571]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021244411]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021243521]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021241451]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibroadenoma, NOS - Female, 15 - Tissue image [7060729599326241]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [7040247104956411]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021246151]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sialadenoma papilliferum - Female, 15 - Tissue image [5170730021242641]
Dane BadawczeThis is the histopathological image of PALATE tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, malignant - Male, 15 - Tissue image [5150730018704471]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neural oscillations induced by IAPS pictures (session 15)
Dane BadawczeThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Ultra-Wideband Vivaldi Antenna with an Integrated Noise-Rejecting Parasitic Notch Filter for Online Partial Discharge Detection
PublikacjaPower transformers and gas-insulated switchgear (GIS) play crucial roles in electrical power grids. However, they may suffer from degradation of insulation material due to wear and tear, leading to their imminent failure. Partial discharges (PDs) are an initial sign of insulation materials degradation which emit signals spanning various physical domains, including electromagnetic. PDs are temporally narrow, high-frequency, stochastic...
-
AeroSense Measurements: Wind Tunnel Ecole Centrale Lyon
Dane BadawczeData from wind tunnel tests of Aerosesne measurement system installed on NACA 63418 aerfoil in the anechoic wind tunnel at the Ecole Centrale Lyon.
-
Microfluidically Frequency-Reconfigurable Self-Quadruplexing Antenna Based on Substrate Integrated Square-Cavity
PublikacjaIn this article, a novel concept of self-quadruplexing tunable antenna (SQTA) enabled by microfluidic channels is investigated. The operating channels are either filled with air or dielectric liquids to enable frequency tunability. The proposed SQTA is implemented on the substrate-integrated square-cavity (SISC). A swastika-shaped slot is milled on the top-surface of the SISC to create four quarter-mode resonators. The resonators...
-
Compact 4 × 4 butler matrix with non‐standard phase differences for IoT applications
PublikacjaButler matrices represent a popular class of feeding networks for antenna arrays. Large dimensions and the lack of flexibility in terms of achievable output phase difference make conventional Butler structures of limited use for modern communication devices. In this work, a compact planar 4 × 4 matrix with non-standard relative phase shifts of –30º, 150º, –120º, and 60º has been proposed. The structure is designed to operate at...
-
Designing a High-sensitivity Microscale Triple-band Biosensor based on Terahertz MTMs to provide a perfect absorber for Non-Melanoma Skin Cancer diagnostic
PublikacjaNon-melanoma skin cancer (NMSC) is among the most prevalent forms of cancer originating in the top layer of the skin, with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being its primary categories. While both types are highly treatable, the success of treatment hinges on early diagnosis. Early-stage NMSC detection can be achieved through clinical examination, typically involving visual inspection. An alternative,...
-
Simple and low-cost wireless voting system
PublikacjaThis paper presents the concept of a simple and low-cost wireless voting system working in the 868 MHz frequency band. The described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, a base station and a PC application from which the whole system is mamaged. This...
-
Simple and low-cost wireless voting system
PublikacjaThis paper presents the concept of a simple and low-cost wireless voting system working on the 868 MHz frequency band. Described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, base station and a PC application from which the whole system is managed. This architecture...
-
Unity-Gain Zero-Offset CMOS Buffer with Improved Feedforward Path
PublikacjaA voltage unity-gain zero-offset CMOS amplifier with reduced gain error and increased PSRR (power supply rejection ratio) is proposed. The amplifier uses two feed mechanisms, negative feedback and supporting positive feedforward, to achieve low deviation from unit gain over the entire input range. The circuit, designed in a standard 180-nanometer 1.8-voltage CMOS process, is compared with two known buffers of similar topology,...
-
Design and Optimization of Metamaterial-based Highly-isolated MIMO Antenna with High Gain and Beam Tilting Ability for 5G Millimeter Wave Applications
PublikacjaThis paper presents a wideband multiple-input multiple-output (MIMO) antenna with high gain and isolation, as well as beam tilting capability, for 5G millimeter wave (MMW) applications. A single bow-tie antenna fed by a substrate-integrated waveguide (SIW) is proposed to cover the 28 GHz band (26.5–29.5 GHz) with a maximum gain of 6.35 dB. To enhance the gain, H-shaped metamaterial (MM)-based components are incorporated into the...
-
Expedited Geometry Scaling of Compact Microwave Passives by Means of Inverse Surrogate Modeling
PublikacjaIn this paper, the problem of geometry scaling of compact microwave structures is investigated. As opposed to conventional structures (i.e., constructed using uniform transmission lines), re-design of miniaturized circuits (e.g., implemented with artificial transmission lines, ATSs) for different operating frequencies is far from being straightforward due to considerable cross-couplings between the circuit components. Here, we...
-
Highly Miniaturized Self-Diplexed U-Shaped Slot Antenna Based on Shielded QMSIW
PublikacjaThis article presents an efficient yet simple design approach to highly miniaturized cavity-backed self-diplexing antenna (SDA) with high-isolation. The structure employs a shielded quarter-mode substrate integrated waveguide (QMSIW). Two U-shaped slots are engraved on the top conducting plane, which realize two frequency bands and significant size reduction. The slots are excited by two independent 50Ω orthogonal feed-lines to...
-
Doppler blood flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nadzorowanie drgań układu nośnego robota przemysłowego IRB-6 za pomocą ste-rowania modalnego przy energetycznym wskaźniku jakości. W: Zagadnienia ana- lizy modalnej konstrukcji mechanicznych. Praca zbiorowa pod red. T. Uhla. Kraraków: Kated. Robotyki i Dynam. Masz. AGH**2003 s. 115-122, 2 rys. 1 tab. bibliogr. 4 poz.
PublikacjaW pracy rozważa się drgania modelowanego dyskretnie niestacjonarnego układunośnego manipulatora IRB6 metodą sztywnych elementów skończonych. Do nadzo-rowania drgań wykorzystano algorytm sterowania optymalnego przy energetycz-nym wskaźniku jakości w dziedzinie współrzędnych modalnych. Uwzględnia on zmianę w czasie, względem trajektorii ruchu zadanego, energii potencjalnej, kinetycznej oraz energii sygnału sterującego.
-
Design and Characterization of a Planar Structure Wideband Millimeter-Wave Antenna with Wide Beamwidth for Wearable off-body Communication Applications
PublikacjaThis letter presents the design of a planar single-layer wideband antenna featuring wide beamwidth has well as high and stable in-band gain. The proposed antenna is a planar monopole fed by a bottom-grounded coplanar waveguide to realize wide beamwidth in both the xz- and yz-planes. Simultaneous optimization of all adjustable antenna parameters, carried out at the full-wave electromagnetic simulation level. The constructive interference...
-
Wpływ filtru sieciowego na układ sterowania maszyny dwustronnie zasilanej pracujęcej jako generator.
PublikacjaMaszyna dwustronnie zasilana (MDZ)pracujęca jako generator przy zmiennej prędkości obrotowej wału jest chętnie stosowana w odnawialnych żródłach energii (elektrownie wiatrowe). Sterowaniu podlega moc czynna i bierna dostarczana do sieci. Odpowiednia jakość enegrii dostarczanej do systemu elektroenegretycznego wymaga stosowania filtrów sieciowych, które mogą powodować słabo tłumione oscylacje napięcia. Przedstawiono badania symulacyjne...
-
Wielopoziomowe przekształtniki średniego napięcia (SN) o budowie modułowej
PublikacjaW artykule omówiono wybrane zagadnienia dotyczące zastosowań wielopoziomowych przekształtników średniego napięcia (SN) w układach napędowych o regulowanej prędkości, zwłaszcza w układach z izolacją od sieci zasilającej. W opracowanym przekształtniku zastosowano izolację galwaniczną od sieci zrealizowaną za pomocą izolowanych przetwornic dc-dc z transformatorami wysokiej częstotliwości (> 5 kHz). Przedstawiono zarejestrowane przebiegi...
-
Novel Coplanar-Strip-Based Excitation Technique for Design of Broadband Circularly Polarization Antennas with Wide 3-dB Axial Ratio Beamwidth
PublikacjaIn this paper, a novel excitation technique for design of a single-point-fed compact low-profile wide-slot antennas with broadband circular polarization (CP) and wide 3 dB axial ratio (AR) beamwidth is presented. Two inverted L-shape parasitic strips placed coplanar to the microstrip line of an asymmetric CPW, and a horizontal strip that protrudes from the vertical edge of the backside ground plane of the substrate are used for...
-
High Frequency Harmonics Emission in Smart Grids
PublikacjaPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
High-performance activation of ozone by sonocavitation for BTEX degradation in water
PublikacjaThis work presents a novel advanced oxidation process (AOP) for degradation of emerging organic pollutants – benzene, toluene, ethylbenzene and xylenes (BTEXs) in water. A comparative study was performed for sonocavitation assisted ozonation under 40–120 kHz and 80–200 kHz dual frequency ultrasounds (DFUS). Based on the obtained results, the combination of 40–120 kHz i.e., low-frequency US (LFDUS) with O3 exhibited excellent oxidation...
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublikacjaPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Design of compact self-quintuplexing antenna with high-isolation for penta-band applications
PublikacjaThis article presents a novel compact self-quintuplexing antenna architecture based on a substrate-integrated rectangular cavity (SIRC) for pentaband applications. The proposed self-quintuplexing antenna is constructed by employing an SIRC, one Pi-shaped slot (PSS), one T-shaped slot (TSS), and five 50Ω microstrip feedlines. The PSS and TSS are engraved on the top of the SIRC to create five radiating patches, which are excited...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
A DSC and NMR-Relaxation study of the molecular mobility of water protons interacting with chemically modified starches
PublikacjaChanges in the mobility of water protons in the chemically modified starches (CMS)–water system are studied by differential scanning calorimetry and NMR relaxation. The amounts of unfrozen water at negative temperatures and additional (after gelation) unfrozen for CMS are lower than those for native starch. The proton spin–spin relaxation time T2 for CMS samples, conventionally attributed to the water fraction in starch granules,...
-
Conducted emi propagation modelling in the wound components.
PublikacjaThe modelling of EMC behaviour of power electronics converters require specific models of devices which are adequate in a wide frequency range. A novel equivalent-circuit model of the inductor, suitable for EMC applications, has been developed and validated. The model can be used for the analyses of wounded components' behaviour in the conducted-EMI frequency range. The parameters of the proposed model can be evaluated based on...