Filtry
wszystkich: 1671
-
Katalog
- Publikacje 1338 wyników po odfiltrowaniu
- Czasopisma 15 wyników po odfiltrowaniu
- Osoby 22 wyników po odfiltrowaniu
- Wynalazki 7 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 5 wyników po odfiltrowaniu
- Kursy Online 4 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 278 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: IMPEDANCE SPECTROMETER
-
Phase I and phase II metabolism simulation of antitumor-active 2-hydroxyacridinone with electrochemistry coupled on-line with mass spectrometry.
PublikacjaHere, we report the metabolic profile and the results of associated metabolic studies of 2-hydroxyacridinone (2-OH-AC), the reference compound for antitumor-active imidazo- and triazoloacridinones. Electrochemistry coupled with mass spectrometry was applied to simulate the general oxidative metabolism of 2-OH-AC for the first time. The reactivity of 2-OH-AC products to biomolecules was also examined. The usefulness of the electrochemistry...
-
Direct measurements of odorous volatile organic compounds present in biosolids cakes by Proton Transfer Reaction – Mass Spectrometry Technique
PublikacjaThis paper show the results of investigation of concentration of odorous chemical compounds emitted upon ageing of anaerobically stabilised biosolids that could contribute to the overall odour character of nuisance emissions. Biosolids samples from wastewater treatment plant were collected in spring time. Concentrations of volatile organic compounds using a US EPA flux hood and Proton Transfer Reaction-Time of Flight-Mass Spectrometry...
-
On-line assessment of oil quality during deep frying using an electronic nose and proton transfer reaction mass spectrometry
PublikacjaWe describe a novel method for the quality assessment of oil utilized for deep frying. The method is based on the analysis of frying fumes using a custom electronic nose. The quality score could be obtained after less than 3 min of analysis and without interrupting the frying process or sampling the oil directly. The obtained results were correlated with the peroxide value using a multivariate linear regression model. The most...
-
Determination of nonsteroidal antiinflammatory drugs in water samples using liquid chromatography coupled with diode-array detector and mass spectrometry
PublikacjaOpracowano i zwalidowano metodykę do oznaczania śladowych ilości sześciu różnych związków z grupy niesteroidowych leków przeciwzapalnych w próbkach wodnych. Anality zostały wybrane spośród najczęsciej sprzedawanych leków w Polsce. Sprawdzono kilka różnych kolumienek ekstrakcyjnych i wybrano RP-18 jako najlepsze wypełnienie do wzbogacania oznaczanych związków. Opracowaną metodykę z powodzeniem zastosowano do analizy próbek rzeczywistych.
-
Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples
PublikacjaIn this study, a capsule phase microextraction (CPME) protocol followed by gas chromatography-mass spectrometry is proposed for the accurate and sensitive monitoring of organochlorine pesticides (OCPs) in environmental water samples. Different monolithic sol–gel encapsulated sorbents were compared and monolithic sol–gel poly(ethylene glycol)-based sorbent incorporated into porous microextraction capsules resulted in the highest...
-
Online Volatile Compound Emissions Analysis Using a Microchamber/Thermal Extractor Coupled to Proton Transfer Reaction-Mass Spectrometry
PublikacjaIndoor air is a complex and dynamic mixture comprising manifold volatile organic compounds (VOCs) that may cause physiological and/or psychological discomfort, depending on the nature of exposure. This technical note presents a novel approach to analyze VOC emissions by coupling a microchamber/thermal extractor (μ-CTE) system to a proton transfer reaction-mass spectrometer (PTR-MS). This configuration provides an alternative to...
-
The Mechanism of a Retro-Diels–Alder Fragmentation of Luteolin: Theoretical Studies Supported by Electrospray Ionization Tandem Mass Spectrometry Results
PublikacjaThe mechanisms of retro-Diels–Alder fragmentation of luteolin are studied theoretically using the Density Functional Theory method (B3LYP hybrid functional) together with the 6-311++G(d,p) basis set and supported by electrospray ionization tandem mass spectrometry (ESI-MS) results. The reaction paths leading to the formation of 1,3A and 1,3B fragment ions observed as the main spectral features in the ESI-MS spectrum are described...
-
Direct injection liquid chromatography-mass spectrometry (DI-LC-MS) analysis for rapid lipidomic profiling of extracellular vesicles
PublikacjaExtracellular vesicles (EVs) are small, spherical particles produced by eukaryotic and prokaryotic cells, surrounded by a bilayer membrane and carrying various bioactive molecules, such as proteins, surface receptors, membrane and soluble proteins, lipids, and nucleic acids. EVs are of substantial interest because of their important roles in cell communication, epigenetic regulation and possible application in disease diagnosis...
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
High gain/bandwidth off‑chip antenna loaded with metamaterial unit‑cell impedance matching circuit for sub‑terahertz near‑field electronic systems
PublikacjaAn innovative off-chip antenna (OCA) is presented that exhibits high gain and efficiency performance at the terahertz (THz) band and has a wide operational bandwidth. The proposed OCA is implemented on stacked silicon layers and consists of an open circuit meandering line. It is shown that by loading the antenna with an array of subwavelength circular dielectric slots and terminating it with a metamaterial unit cell, its impedance...
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublikacjaIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Jacek Ryl dr hab. inż.
OsobyStopień doktora nauk technicznych uzyskał w roku 2010. W tym samym roku podjął pracę w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej na Wydziale Chemicznym. W 2018 roku uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie technologia chemiczna. Od 2021 roku zatrudniony w Instytucie Nanotechnologii i Inżynierii Materiałowej Wydziału Fizyki Technicznej i Matematyki Stosowanej PG. W pracy naukowej skupia...
-
Dariusz Świsulski dr hab. inż.
Osoby -
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublikacjaThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Jerzy Wtorek prof. dr hab. inż.
OsobyJerzy Wtorek uzyskał tytuł magistra inżyniera w 1976 roku na Wydziale Elektroniki Politechniki Gdańskiej, a stopień doktora nauk technicznych i doktora habilitowanego na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, odpowiednio w 1986 i 2004 roku. Tytuł profesora uzyskał w 2016 r. Jego zainteresowania dotyczą nieinwazyjnych metod oceny układu krążenia, elektrycznych (aktywnych i pasywnych) właściwości...
-
Nonlinear impedance of 45Bi2VO5.5-55SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 45Bi2VO5.5-55SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 ceramic of thickness 2.88 mm measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 35Bi2VO5.5-65SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 35Bi2VO5.5-65SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance of 25Na2O–20CaO–5P2O5–50SiO2 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 25Na2O–20CaO–5P2O5–50SiO2 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 ceramic of thickness 2.52 mm measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe nonlinear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 30Bi2VO5.5-70SrB4O7 fully crystallized glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 30Bi2VO5.5-70SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Dane BadawczeThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Metody przewidywania temperaturowych zmian impedancji układu grzejnego na podstawie jego charakterystyki częstotliwościowej
Publikacja -
Badanie metody pomiaru impedancji pętli zwarciowej wykorzystującej składowe fazora napięcia. - A. Golijanek-Jędrzejczyk.
PublikacjaMonografia podejmuje ważną tematykę pomiarów impedancji pętli zwarciowej w układach elektroenergetycznych niskiego napięcia związaną z bezpieczeństwem użytkowania urządzeń elektrycznych. W siedmiu rozdziałach pracy zaprezentowano m.in. przegląd znanych metod i mierników do pomiaru impedancji pętli zwarciowej, podstawy teoretyczne oraz analizę metrologiczną dwóch metod impedancji pętli wykorzystujących składowe ortogonalne napięcia...
-
Ograniczenie wpływu odkształcenia napięcia sieci na dokładność pomiaru impedancji uziemień urządzeń elektroenergetycznych
PublikacjaW pracy przedstawiono propozycję nowej metody pomiaru impedancji rozległych uziemień urządzeń elektroenergetycznych. Metoda ta pozwala ograniczyć wpływ odkształcenia napięcia sieci na błędy pomiaru impedancji. Badania i obliczenia błędów przeprowadzone zostały dla wybranych typów odkształceń krzywej napięcia i różnych parametrów obwodu badanego.
-
Wpływ błędów pomiaru wartości skutecznych napięć na dokładność wyznaczenia impedancji pętli zwarciowej
PublikacjaWartość impedancji pętli zwarciowej otrzymuje się na podstawie pomiaru dwóch wartości napięć dla obwodu nieobciążonego oraz obciążonego, najczęściej rezystancją, która stanowi sztuczne zwarcie. Obecnie krzywa napięcia sieci w miejscu pomiaru może być wyraźnie odkształcona. W referacie przedstawiono analizę wpływu błędu pomiaru okresu napięcia sieci na dokładność wyznaczenia impedancji pętli zwarciowej, z uwzględnieniem odkształcenia...
-
Pomiar impedancji pętli zwarciowej w instalacjach fotowoltaicznych dużych mocy z magazynowaniem energii
PublikacjaW artykule przedstawiono różne konfiguracje przepływu energii w instalacjach fotowoltaicznych z zastosowaniem przekształtników energoelektronicznych o mocy od 10 do 1000 kVA. W pomiarach impedancji pętli zwarciowej (IPZ) w obwodach zasilanych z przekształtników przyrządami różnych producentów zaobserwowano wyniki pomiaru zależne od trybu pracy przekształtnika oraz od wartości wymuszanego prądu probierczego przyrządu. W artykule...
-
Sensitive simultaneous determination of 19 fluorobenzoic acids in saline waters by solid-phase extraction and liquid chromatography–tandem mass spectrometry
PublikacjaA solid-phase extraction (SPE) procedure using C18 stationary phase was optimized for the preconcentration of 19 fluorinated derivatives of benzoic acid (FBA): mono-, di-, tri-, and tetrafluorosubstituted in the ring, trifluoromethylbenzoic acid and 3,5-bistrifluoromethyl benzoic acid from undiluted salt-rich (>20%) reservoir waters. Quantitative (>90%) retention/elution of 16 out of 19 analyte compounds was achieved allowing a...
-
Molecular Heterogeneity of Papillary Thyroid Cancer: Comparison of Primary Tumors and Synchronous Metastases in Regional Lymph Nodes by Mass Spectrometry Imaging
Publikacja -
Radiation-related Changes in Serum Proteome Profiles Detected by Mass Spectrometry in Blood of Patients Treated with Radiotherapy Due to Larynx Cancer
Publikacja -
Radiation-related Changes in Serum Proteome Profiles Detected by Mass Spectrometry in Blood of Patients Treated with Radiotherapy Due to Larynx Cancer
Publikacja -
Solid phase extraction and sequential elution for pre-concentration of traces of Mn and Zn in analysis of honey by flame atomic absorption spectrometry
Publikacja -
Element analysis of bee-collected pollen and bee bread by atomic and mass spectrometry – Methodological development in addition to environmental and nutritional aspects
Publikacja -
Determination of β-blockers and β-agonists using gas chromatography and gas chromatography–mass spectrometry – A comparative study of the derivatization step
Publikacja -
Quantification of DNA Modifications Using Two-Dimensional Ultraperformance Liquid Chromatography Tandem Mass Spectrometry (2D-UPLC-MS/MS)
Publikacja -
Determination of PCBs in marine sediment using pressurised liquid extraction-gas chromatography-isotope dilution mass spectrometry -method validation
PublikacjaOpracowano procedurę oznaczania wybranych analitów z grupy PCB w próbkach osadu dennego z wykorzystaniem techniki przyspieszonej ekstrakcji za pomocą rozpuszczalnika (PLE) w połączeniu z chromatografią gazową z detektorem spektrometrii mas. Opracowana procedura analityczna została wykorzystana do analizy próbek morskiego osadu dennego, które stanowiły przedmiot badań międzylaboratoryjnych organizowanych przez Comité Consultatif...
-
Determination of Butyltin Species in Sea Water Samples Using Solid Phase Extraction Followed by Liquid Chromatography - Tandem Mass Spectrometry
PublikacjaReverse phase liquid chromatography (RP-HPLC)-electrospray ionization-tandem mass spectrometry (ESI-MS-MS) was evaluated for the analysis of TBT using solid phase extraction as sample preparation method. TBT was extracted from acidified water samples (spiked with tripropyltin as internal standard) using reversed phase polymeric Strata-X cartridges. Analytes were eluted from cartridges using acetonitrile-water mixture and the volume...
-
Comparison of classical and modern approach of determination of highly polar compounds by High Performance Liquid Chromatography coupled with Tandem Mass Spectrometry
PublikacjaAbstract: Sugars and sugar alcohols are known as highly polar compounds. Four analytes were taken into consideration for comparison of classical and modern approach of separation of highly polar substances. Mannitol was chosen as an example of simple sugar alcohol, sucrose and lactulose as examples of disaccharides and structural isomers, raffinose as an example of complex trisaccharide. Raffinose was also used as internal standard...
-
Identification and characterization of the Indian Yellow dyestuff and its degradation products in historical oil paint tube by liquid chromatography mass spectrometry
PublikacjaAn analytical protocol for identification of dyes using reversed phase liquid chromatography-mass spectrometry with atmospheric pressure electrospray ionization (LC-ESI/MS) is presented. The developed method has been successfully applied in identification of euxanthic acid and euxanthone, the main components of the Indian Yellow dye in a historical oil paint tube produced by Richard Ain`es, a recognizable French company supplying...
-
Comparison of mass spectrometry data and bioinformatics predictions to assess the bona fide localization of proteins identified in cell wall proteomics studies
Publikacja -
Steroid profiles as potential biomarkers in patients with urogenital tract cancer for diagnostic investigations analyzed by liquid chromatography coupled to mass spectrometry
Publikacja -
Molecularly imprinted stir bar sorptive extraction coupled with atomic absorption spectrometry for trace analysis of copper in drinking water samples
Publikacja