Dynamical objectivity in quantum Brownian motion
PublikacjaClassical objectivity as a property of quantum states —a view proposed to explain the observer-independent character of our world from quantum theory, is an important step in bridging the quantum-classical gap. It was recently derived in terms of spectrum broadcast structures for small objects embedded in noisy photon-like environments. However, two fundamental problems have arisen: a description of objective motion and applicability...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Selection of excitation signals for high-impedance spectroscopy
PublikacjaA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
Multispectral impedance quality testing of coil-coating system using principal component analysis
PublikacjaThe task of quality checking of the coil-coated system was undertaken using impedance spectroscopy. In order to properly characterize the system the new impedance spectrum was calculated as an averaged result of 12 experimental spectra obtained from 12 different places of the sample at the same time of immersion in 3% of NaCl. The experimental spectra were recorded for a 24-h period at 1 h intervals between starting points of each...
-
Spectral reflectance modeling of ZnO layers made with Atomic Layer Deposition for application in optical fiber Fabry-Perot interferometric sensors
PublikacjaSuitability of zinc oxide (ZnO) layers grown using Atomic Layer Deposition for operation in optical-fiber extrinsic Fabry-Perot sensors is investigated using a numerical model. Reflectance spectra obtained using the developed model indicate that the application of these layers in optical-fiber extrinsic Fabry-Perot sensors is difficult as it may require a source whose spectrum width is about 300 nm. A series of ZnO layers grown...
-
An optimal form of the finite element mass matrix in the analysis of longitudinal vibrations of rods
PublikacjaIn this paper, an attempt is made to find the optimal form of the mass matrix of a rod finite element, which allows one to obtain the smallest errors in the longitudinal frequency determination of natural vibrations of any boundary conditions within the whole range of determined frequencies. It is assumed that the mass matrix can be treated as a linear combination of the consistent and diagonal matrices. Based on analytical considerations,...
-
Instantaneous power signal measurements for bearing diagnostics
Dane BadawczeBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Theory and application of Near-infrared spectroscopy
PublikacjaIn recent years one can observe a significant increase in the requirements on quality control in all industrial sectors. The growing number of involved analyses makes the traditional, time consuming, requiring use of large quantities of reagents, thus expansive methods inconvenient especially for industrial applications. Fortunately, there is a very fast, cheap and not invasive analytical method that is increasingly used in qualitative...
-
Application of nonlinearity measures to chemical sensor signals
PublikacjaSzumy rezystancji sensorów gazu zawierają istotną informację, która może być przedstawiona nie tylko przez ich gęstość widmową mocy. Analiza tych szumów za pomocą różnych miar nieliniowości może prowadzić do znacznego wzrostu selektywności i czułości czujników gazu. Stwierdzono, że dla dostępnych na rynku czujników gazu zastosowanie funkcji bispektrum dostarcza dodatkowej informacji, potrzebnej do detekcji różnych gazów. Analizując...
-
Application of higher order spectra in harmonic analysis of corrosion process
PublikacjaZjawiska nieliniowe są niezwykle często spotykane w praktyce badań elektrochemicznych i korozyjnych. Typowym przykładem są procesy elektrodowe kontrolowane szybkością przeniesienia ładunku. Często stosowanym w takich przypadkach podejściem jest aproksymacja fragmentu krzywej prąd-napięcie za pomocą charakterystyki liniowej. W niniejszej pracy autorzy prezentują możliwość wykorzystania pomiarów składowych harmonicznych do oceny...
-
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
PublikacjaW pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną, stosowaną w przenośnych spektrometrach Ramana, w pomiarach...
-
Comparative Evaluation of Multicoil Inductive Power Transfer Approaches Based on Z-source Network
PublikacjaThis paper describes comparative evaluation between wireless power transfer topologies with utilization of Z-source network. Paper describes components calculation method. List of open-loop, close-loop simulations were conducted to compare both topologies. Spectrum of signals is also researched.
-
Effect of waviness and roughness components on transverse profiles of turned surfaces
PublikacjaThis paper presents the authors method of simultaneous analysis of roughness and waviness irregularity components, with the aim of better defining the key qualities and characteristics.Periodical surface machining traces may be analyzed spectrally, with the irregularity's peaks and troughs being used to define the wave's amplitude.In this work the standard composition for filtering waviness and roughness components of a surface...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublikacjaThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Detection system for optical coherence tomography: Czerny-Turner spectrometer
PublikacjaResearch methods based on spectral analysis have powerful impact on development in many field of science. Signal spectrum can be a source of useful and important data. It enables to obtain information about physical and chemical properties of tested materials. This paper has been devoted to describe optical design for high resolution spectrometer, which is significant element of optical coherence tomography (OCT) systems. Designed...
-
Demonstrator technologii C-IED
PublikacjaArtykuł przedstawia budowę i działanie opracowanego na Politechnice Gdańskiej demonstratora technologicznego systemu AEGIS, przeznaczonego do przeciwdziałania atakom z wykorzystaniem prowizorycznych urządzeń wybuchowych detonowanych drogą radiową (RCIED — Radio Controlled Improvised Explosive Devices). Przedstawiono zaimplementowaną oryginalną metodę generowania sygnału zagłuszającego o dowolnie ukształtowanym widmie częstotliwościowym,...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Dane BadawczePresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Unusual Influence of Fluorinated Anions on the Stretching Vibrations of Liquid Water
PublikacjaInfrared (IR) spectroscopy is a commonly used and invaluable tool in the studies of solvation phenomena in aqueous solutions. Concurrently, ab initio molecular dynamics (AIMD) simulations deliver the solvation shell picture at a molecular detail level and allow for a consistent decomposition of the theoretical IR spectrum into underlying spatial correlations. Here, we demonstrate how the novel spectral decomposition techniques...
-
The electronic excited states of dichloromethane in the 5.8-10.8 eV energy range investigated by experimental and theoretical methods
PublikacjaWe present a comprehensive experimental high-resolution vacuum ultraviolet (VUV) photoabsorption spectrum of dichloromethane, CH 2 Cl 2 , with absolute cross sections determined for the full 5.8–10.8 eV energy-range. The calculations on the vertical excitation energies and oscillator strengths were performed using the equation-of-motion coupled cluster method, restricted to the single and double excitations level (EOM-CCSD), and...
-
Interactions of fish gelatin and chitosan in uncrosslinked and crosslinked with EDC films: FT-IR study
PublikacjaFilms based on fish gelatin, chitosan and blend of fish gelatin and chitosan before and after cross-linking with EDC have been characterized by FT-IR spectroscopy. The FT-IR spectrum of fish gelatin film showed the characteristic amide I, amide II and amide III bands, and the FT-IR spectrum of chitosan film confirmed that the polymer was only a partially deacetylated product, and included CH3-C=O and NH2 groups, the latter both...
-
Electronic structure and rovibrational predissociation of the 2^1Π state in KLi
PublikacjaAdiabatic potential energy curves of the 3^1Σ^+, 3^3Σ^+, 2^1Π and 2^3Π states correlating for large internuclear distance with the K(4s) + Li(2p) atomic asymptote were calculated. Very good agreement between the calculated and the experimental curve of the 2^1Π state allowed for a reliable description of the dissociation process through a small (∼20 cm−1 for J = 0) potential energy barrier. The barrier supports several rovibrational...
-
MODELLING OF TOXIC COMPOUNDS EMISSION IN MARINE DIESEL ENGINE DURING TRANSIENT STATES AT VARIABLE PRESSURE OF FUEL INJECTION
PublikacjaTransient states are an important part of the spectrum of engine loads, especially the traction engines. In the case of marine diesel engines, transient states are of particular importance in reducing the analysis of motion units for special areas and maneuvering in port, the participation of transient states in the load spectrum significantly increases, also, the emission of toxic compounds from this period increases proportionally....
-
Investigating Feature Spaces for Isolated Word Recognition
PublikacjaThe study addresses the issues related to the appropriateness of a two-dimensional representation of speech signal for speech recognition tasks based on deep learning techniques. The approach combines Convolutional Neural Networks (CNNs) and time-frequency signal representation converted to the investigated feature spaces. In particular, waveforms and fractal dimension features of the signal were chosen for the time domain, and...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a Impulse Radio Interference
PublikacjaThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. IEEE 802.15.4a UWB signal is being used as interferer, also with frame structure modifications which lead to change spectrum of the interference. Equations and coefficients which allow to calculate ratio between power of useful and interference signal are also presented.
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Multi-mode vibronic interactions in the five lowest electronic states of the fluorobenzene radical cation
PublikacjaThe multi-mode vibronic interactions between the five lowest electronic states of the fluorobenzene radical cation are investigated theoretically, based on ab initio electronic structure data, and employing the linear vibronic coupling model. Low-energy conical intersections, and strong vibronic couplings are found to prevail within the set of X-A and B-C-D cationic states, while the interactions between these two sets of states...
-
Frequency response spectra applied to assess efficiency of the training techniques
PublikacjaThe purpose of the research is to assess the increase of the muscle strength and power. Movement of the human body when the moving one impacts a stationary or moving body is taken under consideration. The waveform produced by an impact is transformed into frequency domain. The acceleration record is transformed as a complex spectrum, by the use of a Discrete Fourier Transformation. In this paper the applications of the discrete...
-
Objectivity in the non-Markovian spin-boson model
PublikacjaObjectivity constitutes one of the main features of the macroscopic classical world. An important aspect of the quantum-to-classical transition issue is to explain how such a property arises from the microscopic quantum theory. Recently, within the framework of open quantum systems, there has been proposed such a mechanism in terms of the so-called spectrum broadcast structures. These are multipartite quantum states of the system...
-
Analysis of nonlinear effects as a diagnostic tool
PublikacjaMetody analizy efektów nieliniowych nieliniowej analizy sygnałów na wyjściu testowanych obiektów umożliwiają badanie występowania defektów i uszkodzeń w materiałach i elementach elektronicznych, co jest niezbędne w predykcji niezawodności. W odniesieniu do elementów biernych bardzo skutecznym narzędziem okazuje się być wskaźnik trzeciej harmonicznej (THI - Third Harmonic Index). W artykule bardziej szczegółowo opisano pomiary parametru...
-
Identification of inherent noise components of semiconductor devices on an example of optocouplers
PublikacjaIn the paper, a method of estimation of parameters of Gaussian and non-Gaussian components in the noise signal of semiconductor devices in a frequency domain is proposed. The method is based on composing estimators of two spectra, corresponding to noise (Gaussian component) and two-level RTS noise (non-Gaussian component). The proposed method can be applied for precise evaluation of the corner RTS frequency fRTS in the noise...
-
MAGNETOACOUSTIC HEATING AND STREAMING IN A PLASMA WITH FINITE ELECTRICAL CONDUCTIVITY
PublikacjaNonlinear effects of planar and quasi-planar magnetosound perturbations are discussed. Plasma is assumed to be an ideal gas with a finite electrical conductivity permeated by a magnetic filed orthogonal to the trajectories of gas particles. the excitation of non-wave modes in the filed of intense magnetoacoustic perturbations, i.e., magnetoaciustic heating and streaming, is discussed. The analysis includes a derivation if instantaneous...
-
Polyethylene glycol-coated solid-phase microextraction fibres for the extraction of polar analytes-A review
PublikacjaThe article discusses the merits and limitations of commercially available solid-phase microextraction (SPME) fibres and compares them with the new type of extraction coatings, in particular those containing polyethylene glycol as sorbent, as well as the methods of the preparation of the latter. It also analyses their possible application for the extraction of a broad spectrum of analytes, with particular emphasis on the sampling...
-
Equitable and semi-equitable coloring of cubic graphs and its application in batch scheduling
PublikacjaIn the paper we consider the problems of equitable and semi-equitable coloring of vertices of cubic graphs. We show that in contrast to the equitable coloring, which is easy, the problem of semi-equitable coloring is NP- complete within a broad spectrum of graph parameters. This affects the complexity of batch scheduling of unit-length jobs with cubic incompatibility graph on three uniform processors to minimize...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublikacjaIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Broadening the scope of measurement and analysis of vibrations of an organ pipe employing intensity probe, simulations, and highspeed camera
PublikacjaThis paper shows an integrated approach to measure, analyze, and model phenomena occurring in an organ pipe driven by pressurized air. The aim of this paper is two-fold, i.e., to measure the pressure signal and the intensity field around the mouth by means of an intensity probe and to visualize and observe the motion of the air jet, which represents the excitation mechanism of the system. This is realized through two techniques,...