Filters
total: 3945
filtered: 276
-
Catalog
- Publications 1934 available results
- Journals 295 available results
- Conferences 132 available results
- People 301 available results
- Projects 2 available results
- Laboratories 1 available results
- Research Teams 1 available results
- e-Learning Courses 108 available results
- Events 6 available results
- Open Research Data 1165 available results
Chosen catalog filters
Search results for: brain-computer interface
-
SEM images of symmetrical cell interface with Sr0.90Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at 800 °C, 900 °C and 1000 °C
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with Sr0.90Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at three different temperatures 800 °C, 900 °C and 1000 °C. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating...
-
SEM images of symmetrical cell interface with Sr0.95Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at 800 °C, 900 °C and 1000 °C
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with Sr0.95Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at three different temperatures 800 °C, 900 °C and 1000 °C. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating...
-
Interface diffusion between metallic nanoparticles and silicon substrate
Open Research DataInterface diffusion between metallic nanoparticles and silicon substrate was detected by EDX method. Metallic nanostructures were manufactured by thermal annealing of thin films. Gold and silver nanostructures were chosen for measurements. Samples were annealed for 15 and 60 minutes at 550 deg.
-
SEM images of symmetrical cell interface with SrTi0.30Fe0.70O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.30Fe0.70O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
SEM images of symmetrical cell interface with SrTi0.65Fe0.35O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.65Fe0.35O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
SEM images of symmetrical cell interface with SrTi0.50Fe0.50O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.50Fe0.50O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
SEM images of symmetrical cell interface with SrTi1-xFexO3-d electrodes and CGO-20 substrate sintered at 800 °C
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi1-xFexO3-d (x=0.35; 0.50; 0..70) electrodes and CGO-20 substrate sintered at 800 °C. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 12 kV in a high vacuum...
-
SEM images of symmetrical cell interface with Sr1.05Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at 800 °C, 900 °C and 1000 °C
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with Sr1.05Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at three different temperatures 800 °C, 900 °C and 1000 °C. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating...
-
SEM images of symmetrical cell interface with Sr1.00Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at 800 °C, 900 °C and 1000 °C
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with Sr1.00Ti0.30Fe0.70O3-d electrodes and CGO-20 substrate sintered at three different temperatures 800 °C, 900 °C and 1000 °C. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating...
-
SEM images of Solid Oxide Fuel Cell interface with La0.6Sr0.4Co0.2Fe0.8O3-δ oxygen electrodes sintered at 1050 °C before and after test
Open Research DataThis dataset contains cross section SEM images of Solid Oxide Fuel Cell interface with La0.6Sr0.4Co0.2Fe0.8O3-δ oxygen electrode sintered at 1050 °C before and after test. The cell was tested using Open Flanges™ test Set-up at 700 °C. During the test, the cell was aged for approximately 120 hours at a load of 0.5 A/cm^2. Images were obtained using...
-
SEM images of Solid Oxide Fuel Cell interface with Sr0.95Ti0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C before and after test
Open Research DataThis dataset contains cross section SEM images of Solid Oxide Fuel Cell interface with Sr0.95Ti0.30Fe0.70O3-d oxygen electrode sintered at 800 °C before and after test. The cell was tested using Open Flanges™ test Set-up at 700 °C. During the test, the cell was aged for approximately 120 hours at a load of 0.5 A/cm^2. Images were obtained using a FEI...
-
SEM images of cross sections of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains cross sectional images of the porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes symmetric cells samples interface. Here are presented images of electrodes sintered at 950 °C, 1000 °C and 1050 °C. Images were obtained using a FEI Quanta FEG 250 Scanning Electron Microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum...
-
The instantaneous flicker sensation level measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application...
-
Number of active users of the mobile banking application (only a mobile phone) - 2017
Open Research DataCustomers using mobile devices can use their bank account via the bank's website or a separate application. Such a solution allows for easier logging in (usually no customer number is required, but only a password) and a number of additional functions (from a more extensive interface to a larger number of possible operations - making a transfer, opening...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
The standard radiated immunity test of an astable multivibrator at a normative field strength
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
The radiated immunity test of an astable multivibrator at over-normative field strengths
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz were performed...
-
A cumulative probability function of instantaneous flicker sensation values measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a cumulative probability function CPF of the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage...
-
Investigation of the C-1311 glucuronidation: an electrochemical approach
Open Research DataThis study was undertaken to investigate the glucuronidation of the compound C-1311 (5-diethylaminoethylamino-8-hydroxyimidazoacridinone – the model anticancer acridine derivative) using electrochemistry/mass spectrometry (EC/MS) as a complementary technique to in vitro (liver microsomes) and in silico approaches.
-
Selection of material for infiltration of non-stoichiometric Sr0.95Ti0.3Fe0.7O3-δ
Open Research DataThe porous electrodes used for the infiltration were prepared from A-site non-stoichiometric Sr0.95Ti0.3Fe0.7O3-δ synthesized by the conventional solid state reaction method. Screen printed electrodes (0.5 cm2) on CGO-20 substrate, were fired at 800 °C for 2 hours in an air atmosphere. Infiltration of the scaffolds was performed by a water-based precursor...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0019)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0024)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0023)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Signals of the 5G Standalone Radio Interface
Open Research DataThe research work conducted within the scope of NATO-STO (North Atlantic Treaty Organization – Science and Technology Organization) IST-187 group assumed investigation of the 5G gNodeB performance. The downlink (DL) signals of the FDD (Frequency Division Duplex) 5G-Standalone station were registered in isolated and controlled laboratory conditions....
-
Data gathered in the course of therapeutic sessions carried out with patients suffering from acquired brain damages
Open Research DataThe dataset contains signals gathered in the course of therapeutic sessions carried out with patients suffering from acquired brain damages. Participants’ actions were monitored with an eye-gaze tracking (EGT) device and with an electroencephalogram EEG monitoring headset.
-
An facile Fortran-95 algorithm to simulate complex instabilities in three-dimensional hyperbolic systems
Open Research DataIt is well know that the simulation of fractional systems is a difficult task from all points of view. In particular, the computer implementation of numerical algorithms to simulate fractional systems of partial differential equations in three dimensions is a hard task which has no been solved satisfactorily. Here, we provide a Fortran-95 code to solve...
-
The effect of interview location on the perception of Ecosystem Services provided by trees. A Polish case study.
Open Research DataSeveral survey research methods are available to study attitudes towards the environment, including: CAWI (computer-assisted Internet interview), CATI (computer-assisted telephone interview), CAPI (computer-assisted personal interview), and PAPI (paper-pencil interview). An increasingly popular CAWI approach is the geo-questionnaire – an internet survey...