Filters
total: 1580
filtered: 1381
displaying 1000 best results Help
Search results for: power system voltage stability
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublicationThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublicationThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Design of synchronous generator voltage regulator based on h control theory
PublicationThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublicationIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublicationThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Interline power flow controller - properties and control strategy in dynamic states
PublicationHigh-power electronic converter topologies, in such forms as Unified Power Flow Controllers (UPFC), Static Compensators (STATCOM) and Interline Power Flow Controllers (IPFC), have been used to enhance and optimize the use of transmission facilities, under the concept of a flexible ac transmission system (FACTS). In Europe, the anticipated proliferation of distributed-generation (DG) in the near future, driven by governmental initiatives...
-
Ancillary services to grids provided with distributed generation
PublicationThe paper introduces system for utilization of the customer-side generated energy. Additionally system can secure some ancillary services to grids. Those services include: current active filtering, load voltage stabilization and in case of grid voltage faults - uninterruptible load supplying (possible with energy storage device). Presented experimental results confirm flexibility of this arrangement in processes of power delivery...
-
Modelling and Control of a Brushless Multiphase Doubly-Fed Induction Generator in a Stand-Alone Wind Generation System
PublicationThe development of the novel multiphase brushless doubly-fed generator system and voltage controller for stand-alone mode configuration is proposed in this paper. The generator system is based on the new machine construction with multiphase control winding and traditional three-phase power winding. The dynamic model of multiphase brushless doubly-fed generator is presented, and the control strategy for voltage amplitude and frequency...
-
Study of the Operation of Synchronous Generator Voltage Regulator During the Creation of Post Blackout Start-up Path
PublicationThis paper presents the influence of automatic voltage regulator (AVR) of synchronous generator on the process of creation of post black-out start-up path. Two elements of AVR have a significant impact on this process: underexcitation limiter (UEL) and load compensation (LC). The authors present a theoretical investigation and simulation results that illustrate how the mentioned elements of AVR affect voltage levels in a power...
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublicationThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Neutral point balancing technique for 3-level neutral point clamped converter with servo system
PublicationNeutral point voltage drift compensation technique in 3-level NPC multilevel converter and servo system is described in the paper. Analytical expressions are obtained for power subsystem elements parameters of servo drive system. Simulation of servo system, based on PMSM motor with 3-level NPC converter is considered.
-
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublicationAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
A novel approach to energy safety improvement in the marine power plants with active power surge compensator
PublicationPaper raises a point of power surges and theirs adverse effects in the marine power plants. The article explains a source of surges appearance, and presents measurements carried out on a modern ship. It discusses effects of dynamic power transients on the ship’s energy safety. Finally it proposes, a novel approach for power surge elimination, based on medium voltage active conditioner. As well as it propose the topology and control...
-
An Optimal Power Point Tracking Algorithm in a Solar PV Generation System
PublicationThe non-linearity in I-V characteristics of a PV panel requires to be operated at knee point to extract maximum power. In order to operate the panel at optimal point, maximum power point tracking (MPPT) algorithm is employed in the control structure. The main objective of MPP tracking is to keep the operation at knee point of I-V characteristics under varying condition of temperature and solar insolation. Under non uniform solar...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Intelligent turbogenerator controller based on artifical neural network
PublicationThe paper presents a desing of an intelligent controller based on neural network (ICNN). The ICNN ensures at the same time two fundamental functions : the maintaining of generator voltage at the desired value and the damping of the electromechanical oscillations. Its performance is evaluted on a single machine infinite bus power system through computer simulations. The dynamic and transient operation of the proposed controller...
-
Sensorless predictive control of three-phase parallel active filter
PublicationThe paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique
PublicationThis paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Solutions of inverter systems in Shore-to-Ship Power supply systems
PublicationThe article presents a clearly formulated need for installing S2SP (Shore to Ship Power) systems, in particular Medium Voltage (MV) systems, along with certain solutions of modern inverter systems used in those systems. Requirements and basic configurations of S2SP systems are discussed, focusing in particular on capabilities of the S2SP system with DC distribution busbar. Moreover, on the background of the executing assumptions...
-
Frequency Diagnostics of Transformer Insulating Parameters
PublicationIn the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...
-
Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid
PublicationIn recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...
-
Przekształtnik prądu jako sterownik w układach napędowych z silnikami indukcyjnymi
PublicationThe circuits used for power conversion applied in drives with electric machines are classified into two groups: voltage source inverters (VSI) and current source inverters (CSI). Application of the current source inverter results in better properties of drive than application of voltage source inverter because there is no output filter. The development of power electronics and especially the IGBTs, in which on/off-times are very...
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Optimal Multivariable Control for Modified Z-source Based IPT
PublicationThis paper describes Z-source based inductive power transfer topologies control approaches. The goal of this work is a multi-variable control approach which involves a constant voltage/constant current control along with an optimal frequency control to obtain maximum efficiency. This control is applied to the wireless power transfer system based on a modified Z-source topology. The description of the control method along with simulation...
-
Modified Inductive Multi-Coil Wireless Power Transfer Approach Based On Z-Source Network
PublicationThis article presents a non-conventional approach to a multi-coil wireless power transfer system based on a Z-source network. The novelty of the approach lies in the use of a Z-source as a voltage source for energy transmission through the wireless power transfer coils. The main advantage is in a reduced number of semiconductors. This paper provides the design approach, simulation and experimental study. Feasibility and possible...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublicationThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
CM Voltage Compensators for Power Electronic Interfaces
PublicationThe experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublicationA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...