Filters
total: 9210
filtered: 5960
-
Catalog
- Publications 5960 available results
- Journals 2171 available results
- Conferences 90 available results
- Publishing Houses 3 available results
- People 455 available results
- Projects 35 available results
- e-Learning Courses 194 available results
- Events 33 available results
- Open Research Data 269 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: ADVANCES IN MATERIALS SCIENCE
-
ADVANCES IN MATERIALS SCIENCE EDITORIAL ON THE JOURNAL'S 20th ANNIVERSARY
PublicationEditorial on the occasion of the 20th anniversary of Advances in Materials Science journal.
-
Special Issue: Recent Advances in Corrosion Science
PublicationThe dynamic development of the global industry and growing demand for new material technologies generates constantly increasing problems regarding premature material degradation and the requirement to determine corrosion mechanisms and to develop new protection/evaluation approaches. This Special Issue, “Recent Advances in Corrosion Science”, brings together fourteen articles and one review, providing a snapshot of the recent activity...
-
Recent Advances in Development of Waste-Based Polymer Materials: A Review
PublicationLimited petroleum sources, suitable law regulations, and higher awareness within society has caused sustainable development of manufacturing and recycling of polymer blends and composites to be gaining increasing attention. This work aims to report recent advances in the manufacturing of environmentally friendly and low-cost polymer materials based on post-production and postconsumer wastes. Sustainable development of three groups...
-
Advances in Hard–to–Cut Materials: Manufacturing, Properties, Process Mechanics and Evaluation of Surface Integrity
Publication -
Recent advances on magnetic carbon-related materials in advanced oxidation processes of emerging pollutants degradation
PublicationRecently, carbon-related materials have been proposed to improve the charge separation of the photogenerated carriers in the semiconductor matrices’ and surface properties. Carbon-related materials may act as co-catalysts, enhancing the pollutants adsorption on the surface, improving the charge carriers separation and photocatalyst stability and providing more active centres for photocatalytic reactions. This review summarizes...
-
Towards the Application of Structure-Property Relationship Modeling in Materials Science: Predicting the Seebeck Coefficient for Ionic Liquid/Redox Couple Systems
PublicationThis work focuses on determining the influence of both ionic liquid (IL) type and redox couple concentration on Seebeck coefficient values of such a system. The quantitative structure property relationship (QSPR) and read-across techniques are proposed as methods to identify structural features of ILs (mixed with LiI/I2 redox couple), which have the most influence on the Seebeck coefficient (Se) values of the system. ILs consisting...
-
Nanotechnologies in Development of Structural Materials and Biomaterials
PublicationThe nanometric materials and technologies resulted in nanostructures are reviewed. The examples of nanomaterials are shown. The typical nanotechnologies, including plastic deformation, mechanical attrition, controlled detonation, hot plasma jet synthesis, laser vaporisation, CVD and PVD, mechanical milling, annealing, ultrasonic irradiation, nanolithography, electrocrystallisation, electrospinning, sol-gel method, cryogenic laser-enhanced...
-
Estimation of cavitation erosion resistance of materials
PublicationW pracy przedstawiono ocenę odporności kawitacyjnej 17 materiałów. Do opisu odporności kawitacyjnej zaproponowano nowy wskaźnik liczbowy uwzględniający długość okresu inkubacji, maksymalną prędkość niszczenia oraz czas po którym wystąpi maksymalna prędkość niszczenia materiału. Zaproponowany wskaźnik porównano ze wskaźnikiem δcav, który reprezentuje całą krzywą erozji kawitacyjnej materiału.
-
Methods for the characterizing hydrogen degradation of materials
PublicationDokonano przeglądu różnych metod szacowania podatności na niszczenie wodorowe materiałów metalowych. Zaprezentowano charakterystyki warunków środowiskowych: standardowe składy środowisk ciekłych i gazowych, temperatury, warunki polaryzacji elektrochemicznej. Omówiono metody mechaniczne szacowania niszczenia wodorowego różniące się stanem naprężeń, w tym badania: przy stałym obciążeniu, stałym odkształceniu i stałej niskiej szybkości...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Project of hip joint endoprothesis for an individual patient with materials selection
PublicationThis work includes the hip replacement design, based on the patient's medical records, the description of creation process and materials used for individual components.
-
Induction Assisted Hybrid Friction Stir Welding of Dissimilar Materials AA5052 Aluminium Alloy and X12Cr13 Stainless Steel
PublicationThis research aimed to study the induction in-situ heated hybrid friction stir welding (IAFSW) method to join AA5052 aluminium alloy with X12Cr13 stainless steel (SS) to enhance joint strength. The potency of this method on the mechanical properties and microstructural characterizations were also investigated. The results show that the transverse tensile strength gained was 94% of the AA5052 base metal that is 229.5 MPa. This superior...
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
-
Electrochemical Characterization of Gelatine Derived Ceramics
PublicationNew materials obtained by pyrolysis of gelatine (G) and poly(1,2-dimethylsilazane) (PSN) (weight ratio: G/PSN 70/30) at temperatures 700 and 900 °C were characterized by SEM and Raman spectroscopy. The presence of ceramics influences on the cluster size of the materials. Electrochemical tests were performed by cyclic voltammetry and galvanostatic cyclic polarization. The capacity of G/PSN was 464 and 527 mAh/g for materials pyrolysed...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
An Influence of Factors of Flow Condition, Particle and Material Properties on Slurry Erosion Resistance
PublicationThe degradation of materials due to slurry erosion is the serious problem which occurs in the power industries. The paper presents actual knowledge about an influence of individual factors connected with flow conditions, particles and material properties on the slurry erosion resistance. Among the factors connected with operating conditions, an influence of impact angle, and velocity of impact, particle concertation and liquid...
-
INFLUENCE OF PRESERVATIVE ON THE TENSILE STRENGTH OF THE TISSUE OF PORCINE CIRCULATORY SYSTEM
PublicationCurrently one of the leading causes of death worldwide is heart diseases which include calcification of heart valves and vascular aneurysm. There are many biomaterials that can substitute pathologically altered tissue, however, none of them is as perfect as native tissue. Currently, scientists are looking for new biomaterials that can be successfully implanted without exposing the patient to reoperation. Each material introduced...
-
Cavitation Erosion of P110 Steel in Different Drilling Muds
PublicationThe P110 steel specimens were subjected to ultrasonic cavitation erosion in different compositions of drilling muds and surfactant additive. The test procedure was based on ASTM-G-32 standard recommendations. API 5CT-P110 steel is used for pipes in oil and gas industry. The harsh environment and high velocity of flows poses corrosive and erosive threat on materials used there. The composition of drilling fluid influences its rheological...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublicationTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Slurry Erosion -Design of Test Devices
PublicationDegradation of material caused by impacts of a solid particle (erodent) suspended in a liquid is called slurry erosion and is a major problem in the hydropower and maritime industry. Slurry erosion depends on many factors, e.g. liquid and erodent velocity, size, shape, angle of impact, hardness and number of erodents, and strength of a target material. The various types of test devices have been designed to investigate an effect...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Cavitation erosion degradation of Belzona® coatings
PublicationIn hydrocarbon and maritime industry there is a constant need of materials and coatings withstanding severe conditions. One of adverse phenomena present there is cavitation erosion. The paper presents evaluation of cavitation resistance of three different steel coatings. Belzona 2141 (ACR-Fluid Elastormer), 1321 (Ceramic S-Steal) and 5831 (ST-Barrier) were deployed on P110 steel and subjected to ultrasound cavitation in distilled...
-
Cavitation Erosion Resistance Influence of Material Properties
PublicationThe cavitation erosion is the phenomena that causes degradation of fluid flow machinery components due to repetitive implosion of cavitation bubbles adjacent to the solid surface. Cavitation erosion is a complex phenomenon, which includes not only hydrodynamic factors of liquid, but also properties of erodible material e.g. microstructure, hardness or Young modulus. In order to reduce the negative impact of erosion on machine components,...
-
Reactions on the surface of the implant under the influence of biofilm
PublicationThe contact of a biomaterial with the biological environment in in vitro and in vivo tests leads to the production of a particular ecosystem in which the active roles perform both, the material surface and the extracellular matrix protein forming a biofilm. Proteins affect cell and bacteria adhesion processes, biological activity of cells and activation of inflammatory response.The knowledge of the reaction mechanisms active on...
-
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio - Tribological Applications
PublicationA method is presented for the comparative testing of wear resistance of ceramic coatings made from materials potentially feasible in tribo - medical applications, mainly orthopaedic implants made from ceramics coated metals for low cost, long life and low wear particle emission into the body. The method was devised as the main tool for use in research and is comprised of flat on flat and ball on flat surface (sliding) tests. Seven...
-
Novel Polyurethanes as Antifouling Paint Matrices
PublicationThe new poly(ester-ether urethane)s (PEEUR) were prepared in two stage synthesis from formerly obtained oligo(alkylene ester-ether)diols (OAEE) and 4,4‘-diphenylmethane diisocyanate (MDI). PEEUR samples were subjected to crosslinking with styrene in the presence of radical polymerization initiators: methyl ethyl ketone peroxide (MEKPO) or cobalt 2-ethyl cyclohexanoate (EtHCo). Crosslinked PEEUR were characterized by their physicochemical...
-
Effects of CO2 and Nd:YAG Laser Remelting of the Ti6Al4V Alloy on the Surface Quality and Residual Stresses
PublicationThe titanium alloys are materials susceptible to tribological wear and the laser treatment can be applied in surface treatment processes to obtain for example higher hardness level. From the other side, it is important to take into consideration, that hardness increase that can be connected with cracks . The aim of this research was to investigate the effects of different lasers and the process parameters on the form and level...
-
Underwater welded joint properties investigation
PublicationPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Optoelectronic system for investigation of cvd diamond/DLC layers growth
PublicationDevelopment of the optoelectronic system for non-invasive monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during μPA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The system uses multi-point Optical Emission Spectroscopy (OES) and long-working-distance Raman spectroscopy. Dissociation of H2 molecules, excitation and ionization of hydrogen atoms...
-
Microstructure and properties of the cobalt base clad layers after long time service
PublicationBadaniu poddano napawane laserowo warstwy ze stopu na bazie kobaltu. Warstwy wykonane na przylgni grzybka zaworu wylotowego silnika diesla badano po dwóch latach eksploatacji w dwóch silnikach laboratoryjnych. Badania mikrostruktury nie wykazały znaczących zmian. Przeprowadzono również badania chemiczne oraz pomiary twardości warstw po eksploatacji. Badany typ napoin nie wykazał znaczących uszkodzeń po długim czasie eksploatacji.
-
Reliable method of assessing fracture properties of asymmetric bonded joints
PublicationTwo methods of assessing fracture properties of adhesive joints were studied. Two wedge tests: with continuous deflection and with force measurements were compared. Asymmetric geometry of the bonded joint was considered, i.e. two different plates of aluminium alloys: Al-Cu and Al-Mg, were bonded with epoxy DGEBA adhesive. The analytical model is shown to estimate the values of fracture properties: crack position and critical fracture...
-
Surface modifications of ti and its alloys
PublicationThis article reviews the various surface modification techniques pertaining to titanium and titanium alloys including physical treatment, mechanical treatment, and chemical and electrochemical treatment. The proper surface modification expands the use of titanium and its alloys in the biomedical field for long-term implants retaining the excellent properties of substrate material and improving the specific surface properties required...
-
Hydroxyapatite coatings on porous ti and ti alloys
PublicationDeposition of hydroxyapatite coating on porous Ti and Ti alloys with electrochemical and biomimetic deposition approach is presented. The enhancement of phosphates deposition by well oriented and uniform titanium oxide nanotube array on the surface of titanium substrate is discussed.
-
Influence of laser remelting at cryogenic conditions on corrosion resistance of non-ferrous alloys
PublicationCelem nadtapiania laserowego elementów wytwarzanych z stopów aluminium, miedzi i tytanu jest uzyskanie wysokiej twadrości i odporności na korozję dla wydłużenia okresu ich eksploatacji w rezultacie ich szybkiej krystalizacji. Końcowa mikrostruktura, skład fazowy i właściwości wymienionych stopów zależą od parametrów obróbki laserowej oraz budowy wykresów równowagi fazowej. W artykule przedstawiono wpływ laserowego nadtapiania...
-
Optimal Features of Porosity of Ti Alloys Considering their Bioactivity and Mechanical Properties
PublicationW artykule przedstawiono wpływ porowatości i rozmiaru porów tytanu i jego stopów, użytych, jako materiały ortopedyczne, na bioaktywność i własności mechaniczne struktur porowatych. Optymalne cechy porowatych rusztowań tytanowych umożliwiają rekonstrukcję i regenerację tkanki kostnej w zastosowaniach przenoszących obciażenie.
-
Underwater welding - a review
PublicationW artykule przedstawiono stan obecny oraz perspektywy rozwoju technik spawania pod wodą. Przeanalizowano najważniejsze problemy spawania w środowisku wodnym. Przedstawiono najważniejsze kierunki badań spawania podwodnego podejmowane w Katedrze Technologii Materiałów Maszynowych i Spawalnictwa Politechniki Gdańskiej
-
Microbiological corossion of metallic products as a result of biofilm
PublicationWarunkiem do pojawienia się korozji mikrobiologicznej jest utworzenie na powierzchni metalu biofilmu. Zawiera on biologicznie czynne mikroorganizmy wraz z produktami ich przemian metabolicznych. Biofilm ogranicza dyfuzję produktów metabolizmu wytwarzanych przez poszczególne komórki mikrokolonii. Powoduje to, że produkty uboczne tych przemian gromadzą się w bezpośrednim sąsiedztwie metalu. Gdy powierzchnia metalu nie jest odporna...
-
Surface cracking of laser melted Ti-6Al-4V alloy
PublicationOpisano charakterystyczne cechy pękania powierzchniowego obserwowanego po nadtapianiu laserem CO2 i Nd:YAG stopu Ti-6Al-4V. Obserwowano pęknięcia niezależnie od sposobu nadtapiania, penetrujące głęboko strefę przetopioną i w niewielkim stopniu zależne od sposobu nadtapiania. Przypisano obserwowane zjawisko przemianie martenzytycznej i (lub) naprężeniom cieplnym powstającym podczas gwałtownego chłodzenia.
-
Effects of the time and temperature on the oxide scale formed on the cobalt alloys
PublicationWarstwy wykonane za pomocą techniki PTA ze stopu kobaltu poddano utlenianiu w różnych temperaturach i w różnym czasie. Mikrostruktury otrzymane po utlenianiu wskazują na proces degradacji materiału. Proces ten prowadził do degradacji obszarów międzydendrytycznych napoiny. Skład chemiczny powstającej zgorzeliny byłzależny od temperatury utleniania, składu chemicznego stopu, ze szczegfólnym uwzględnieniem obecności małych ilości...
-
FEM approach to estimate the behaviour of biocomposite metal-surface coating system
PublicationA three dimensional (3D) model of biocomposite metal-surface coating system, which is influenced byknown external forces, is proposed. This model consists of the metallic substrate (Ti6Al4V) and thehydroxyapatite (HA) coating. Using FEM (finite element method), strain-stress maps of model weregenerated for investigating relations between the extreme stress of HA coating and the magnitude ofexternal force and the thickness of the...
-
Assessment of cavitation erosion damage of laser remelted the SUPERSTON alloy
PublicationW artykule przedstawiono wpływ obróbki laserowej w warunkach kriogenicznych na mikrostrukturę stopu SUPERSTON po badaniach kawitacyjnych. Badania odporności kawitacyjnej przeprowadzono na stanowisku z wirującą tarczą w IMP PAN Gdańsk. Określono kinetykę ubytku masy próbek podczas testu kawitacyjnego dla stopu odlanego i nadtopionego laserowo.
-
Assessment of evaporator tubes corrosion in low-emission steam boilers
PublicationW artykule przedstawiono wyniki badań rur ekranowych(16Mo3) kotła niskoemisyjnego po jednym roku i dwóch latach eksploatacji. Powierzchnie rur pokryte zostały warstwami natryskiwanymi cieplne - pojedynczą ze stopu 70%Ni 30%Cr i podwójną Ni-30Cr /Al2O3. Rury bez powłok natryskiwanych wykazywały pocienienie ze względu na działanie korozji siarkowej oraz korozyjnego oddziaływania warstwy stopionych soli. Pojedyncza warstwa 70%Ni 30%Cr...
-
Pure silicon recovering from photovoltaic modules
PublicationOdzyskiwanie krzemu ze zużytych lub uszkodzonych modułów fotowoltaicznych może mieć znaczenie nie tylko ekonomiczne, ale również ekologiczne. Etap obejmujący procesy chemiczne wymaga optymalizacji z punktu widzenia wymaganej czystości odzyskiwanego krzemu. W pracy przedstawiono wyniki przeprowadzonych prób trawienia poszczególnych warstw ogniw PV: warstwy antyodblaskowej, metalizacji (kontaktów), złącza p-n. Skład roztworów trawiących...
-
Coatings in arthroplasty [online]
PublicationThe modern coatings used in arthroplasty for long term implants are reviewed. The phosphate coatingsare the most popular technique to improve the bone-implant interfacial strength and promote theosseointegration. The plasma spraying, electrophoretic precipitation, powder metallurgy, ion beamsputtering, high velocity oxy-fuel (HVOF) combustion spraying, sol-gel technique, biomimeticdeposition are mostly used to obtain the phosphate,...
-
Fracture of aluminium joints bonded with epoxy adhesive reinforced by mmt nanoparticles
PublicationCrack propagation behavior was studied for aluminium/aluminum adhesive joints bonded with two epoxy adhesives: pure and reinforced with clay nanoparticles. The focus was also on the novel use of the constant displacement rate test to study adhesion/adhesives efficiency. The epoxy systems studied were: Epidian E6 produced from bisphenol A and epichlorohydrin, (''Organika -Sarzyna'' Poland); pure or strengthened with montmorillonit...
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublicationTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublicationImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.