Filters
total: 70
filtered: 47
Chosen catalog filters
Search results for: CURRENT COLLECTOR
-
3D scanning system for railway current collector contact strips
PublicationUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
A new approach to determination of the two-mass model parameters of railway current collector
PublicationThe paper presents two mathematical models of railway current collectors both with two degrees of freedom. The first one, hereinafter Pantograph Articulated Model (PAM), has one degree of freedom in rotational motion and the second degree of freedom in translational motion. The second model, called henceforth as Pantograph Reference Model (PRM), has both degrees of freedom in translational motion. Differential equations of the...
-
A new approach to determination of the two-mass model parameters of railway current collector
PublicationThe paper presents two mathematical models of railway current collectors both with two degrees of freedom. The first one, hereinafter Pantograph Articulated Model (PAM), has one degree of freedom in rotational motion and the second degree of freedom in translational motion. The second model, called henceforth as Pantograph Reference Model (PRM), has both degrees of freedom in translational motion. Differential equations of the...
-
Monitoring of current collectors on the railway line
PublicationProper cooperation the current collectors and the overhead line is a pre-requisite for reliable and safe operation of railway transport. Instances of maladjustment and, in some cases, damage to the current collectors, occur between periodic inspections of the rolling stock. In order to detect such anomalies quickly, the test stand was developed, with the aim of monitoring the technical state of the current collectors under operating...
-
Visual measurement system for chosen parameters of current collectors
PublicationA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Technical diagnostics and monitoring of traction current collectors
PublicationNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
Modal analysis of railway current collectors using Autodesk Inventor
PublicationThe paper presents the results of modal analysis of railway current collector type 160EC. In the first place, the analysis was carried out analytically for a simplified two lumped mass pantograph model. Then numerical analysis was conducted in the Autodesk Inventor (AI) on the prepared multibody model using the AI modal analysis algorithm, which is based on the finite element method (FEM). Model elements which are most relevant...
-
3D Machine Vision System for Inspection of Contact Strips in Railway Vehicle Current Collectors
PublicationConstruction and technical condition of current collectors is crucial to reliability and safety of railway transportation. According to the Technical Specifications for Interoperability railway vehicles in the European Union should be equipped with carbon contact strips. Excessive wear or defects of contact strips degrade the capability of undisturbed power transmission, cause faster wear of contact wire, and can even result in...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublicationThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
Interaction of SrTi0.65Fe0.35O3-δ with LaNi0.6Fe0.4O3-δ, La0.6Sr0.4Co0.2Fe0.8O3-δ and Ce0.8Gd0.2O2-δ
PublicationIron doped strontium titanates SrTi1-xFexO3-δ are perovskites of versatile properties. They can be used in solid oxide fuel cells or high temperature oxygen sensors. Their reactivity with electrolyte materials, cathode buffer layer materials, other cathode materials or current collector layers has not been fully tested. In this study we use X-ray diffraction to check SrTi0.65Fe0.35O3-δ compatibility with Ce0.8Gd0.2O2-δ (used as...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Nowa metoda diagnostyki stanu technicznego nakładek stykowych
PublicationThe current collection system, which consists of the overhead contact line and a current collector, is particularly important in electric rail vehicles, where their reliability is concerned. Faultless current collection is conditioned not only by suitable construction of these elements but also by their proper maintenance. Retaining permanent electrical contact is essential in DC systems, where current demand is relatively high. In...
-
Design of a SiC based triple active bridge ceil for a multi-megawatt DC-DC converter
PublicationThe paper describes the design methodology of a novel Triple Active Bridge cell used as the building block for modular DC-DC converters. The intended application is for Medium Voltage Direct Current grids, such as the DC collector for offshore wind farms. The latest generation of SiC MOSFET semiconductors is utilized to operate in the medium frequency range while optimizing the efficiency. The dimensioning of the main cell components,...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublicationThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
Modelowanie dynamiki odbieraka prądu pojazdu kolejowego do celów diagnostycznych
PublicationNiewłaściwa współpraca odbieraka prądu i sieci trakcyjnej, w trudnych warunkach lokalnych, może prowadzić do uszkodzenia sieci trakcyjnej i pantografu. W ramach rozwoju metod monitoringu i diagnostyki dla tych podsystemów, tworzone są nowe i dokładniejsze narzędzia symulacyjne, których zakres obejmuje modelowanie zarówno napowietrznej sieci trakcyjnej i pantografu, a także ich dynamicznego oddziaływania. Głównym celem jest dokładniejsza...
-
Wybrane aspekty modelowania matematycznego kolejowego odbieraka prądu
PublicationNieprawidłowa współpraca odbieraka z siecią jezdną, w niekorzystnych warunkach lokalnych, prowadzi do uszkodzeń sieci lub odbieraka. Może być to spowodowane niewłaściwym wykonaniem lub utrzymaniem tych istotnych elementów układu zasilania. Tego typu sytuacje awaryjne powodują duże opóźnienia w ruchu pociągów i generują olbrzymie koszty. Wskazuje to na duże znaczenie odpowiednich rozwiązań konstrukcyjnych sieci i odbieraków oraz...
-
Koncepcja zdalnego sterowania i monitoringu urządzeń trakcyjnych z wykorzystaniem technologii teleinformatycznych
PublicationAdvancement in wireless communication enables engineers to apply sophisticated and relatively inexpensive technologies in new fields of industry, which were previously designated solely to wire-based solutions. One of those fields is railway transportation system. In effect of a high reliability and safety demands, this area was resistive to new technologies. Nowadays, increased security and reliability of wireless sensor networks...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublicationTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Algorithm for Automatic Wear Estimation of Railway Contact Strips Based on 3D Scanning Results
PublicationElectric rail vehicles use current collection system which consists of overhead contact line and a current collector (pantograph) mounted on the roof of a vehicle. A pantograph is equipped with contact strips, which slide along the contact wire, ensuring steady electric contact. Contact strips are made of carbon layer, fixed to an aluminum carrier. The carbon layer wears down due to friction. Using overly worn contact strips increases...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublicationCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Visual method for detecting critical damage in railway contact strips
PublicationEnsuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle's power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL)...
-
Modelowanie i symulacja dynamiki ruchu trakcyjnego odbieraka prądu
PublicationW artykule przedstawiono dwa modele matematyczne kolejowych odbieraków prądu. Model podstawowy opracowano na podstawie analizy konstrukcji odbieraka ze stopniami swobody w ruchu obrotowym i postępowym. Drugi tzw. model zastępczy ma obydwa stopnie swobody w ruchu postępowym. Przedstawiono prosty sposób wyznaczenia wartości parametrów modelu zastępczego na podstawie wyników symulacji modelu odbieraka podstawowego. Model zastępczy,...
-
Analiza ruchowa pojazdów szynowych z uwzględnieniem zmian napięcia na odbieraku prądu
PublicationW artykule zaproponowano metodykę wykonywania analizy ruchowej pojazdów szynowych, która uwzględnia wpływ zmieniającego się napięcia zasilającego pojazd a jego właściwości ruchowe. Wykorzystując model opracowany w programie Simulink wskazano na istotne różnice w czasie przejazdu oraz w wartościach napięcia zasilającego pomiędzy proponowanym sposobem analizy a powszechnie stosowanym podejściem uproszczonym.
-
Data on LEGO sets release dates and worldwide retail prices combined with aftermarket transaction prices in Poland between June 2018 and June 2023
PublicationThe dataset contains LEGO bricks sets item count and pricing history for AI-based set pricing prediction. The data spans the timeframe from June 2018 to June 2023. The data was obtained from three sources: Brickset.com (LEGO sets retail prices, release dates, and IDs), Lego.com official web page (ID number of each set that was released by Lego, its retail prices, the current status of the set) and promoklocki.pl web page (the retail...
-
Analiza wyników monitoringu odbieraków prądu w warunkach ruchowych na linii kolejowej
PublicationOmówiono metodę ciągłego monitorowania stanu odbieraków prądu na linii kolejowej w oparciu o pomiar uniesienia przewodów jezdnych sieci trakcyjnej w czasie przejazdu pociągu. Omówiono zasadę działania wdrożonego stanowiska monitoringu. Opisano algorytmy analizy danych pomiarowych - w szczególności oszacowania siły statycznej odbieraka prądu - i przyjęte kryteria oceny odbieraka. W analizie bierze się pod uwagę także prędkość pociągu...
-
System monitoringu odbieraków prądu pojazdów kolejowych w aspekcie bezpieczeństwa i ciągłości ruchu.
PublicationOmówiono metodę monitorowania stanu technicznego odbieraków prądu w oparciu o pomiar uniesienia przewodów jezdnych sieci trakcyjnej w czasie przejazdu pociągu. Opisano konstrukcję i zasadę działania wdrożonego na linii kolejowej pilotażowego stanowiska monitoringu. Przedstawiono metodę analizy i sposób wizualizacji wyników pomiarów. Zastosowany algorytm szacowania siły statycznej odbieraka uwzględnia prędkości pociągu i działanie...
-
Analiza drgań przewodu jezdnego sieci trakcyjnej w aspekcie oceny jej stanu technicznego.
PublicationGórna sieć trakcyjna jest nadal najefektywniejszym sposobem zasilania kolejowych pojazdów elektrycznych. Sieć jezdna nie ma możliwości technicznych redundancji, co wymaga okresowej oceny stanu technicznego w celu zapewnienia prawidłowej współpracy z odbierakami prądu pojazdów. W artykule przedstawiono aspekty oceny stanu technicznego górnej sieci trakcyjnej na podstawie modelowania matematycznego i wybranych badań laboratoryjnych....
-
Wizyjny system monitoringu stanu nakładek stykowych odbieraków prądu
PublicationEksploatowane do niedawna w Polsce nakładki pantografów kolejowych były wykonywane w postaci styków miedzianych. Na początku 2011 r. przeprowadzono kompleksową zmianę typu nakładek stykowych, stosowanych przez operatorów korzystających z infrastruktury PKP PLK S.A., z miedzianych na metalizowane węglowe. Wraz z wprowadzeniem nakładek węglowych istnieje potrzeba opracowania nowych metod diagnostyki tego istotnego elementu toru zasilania...
-
Design and characterization of apatite La9.8Si5.7Mg0.3O26±δ-based micro-tubular solid oxide fuel cells
PublicationIn this study, electrolyte-supported (Cell A) and anode-supported (Cell B) micro-tubular solid oxide fuel cells (SOFCs) based on the La9.8Si5.7Mg0.3O26±δ (LSMO) electrolyte is built through an extrusion and dip-coating processes. The formulations and process conditions for these cells are established and optimized. Both cell configurations show no visible delamination or cracking, and reaction zones and inter-diffusion of any species...
-
Performance of the flat plate solar collector operated with water-Al2O3 nanofluid
PublicationThis paper shows the experimental results of the performance a flat plate solar collector with water-Al2O3 nanofluid as a working fluid. The weight fractions of nanoparticles were 0.1%, 0.2% and 0.4%. The volume flow rate of nanofluid varied from 60 l/h to 170 l/h. The results show that application of nanofluids instead of pure water resulted in higher efficiency of the tested flat plate solar collector for given range of thermal...
-
Modelowanie matematyczne górnej sieci trakcyjnej dla potrzeb diagnostyki odbieraków prądu
PublicationGórna sieć trakcyjna jest obecnie najbardziej skutecznym sposobem zasilania kolejowych pojazdów elektrycznych. Wzrost prędkości pojazdów zwiększa pobór mocy i wymaga zapewnienia właściwej współpracy odbieraków prądu pojazdów z siecią jezdną. Metody modelowania i projektowania wspomaganego komputerowo dla górnej sieci trakcyjnej są obecnie na całym świecie szeroko rozwijane. W artykule przedstawiono nowy model matematyczny elementów...
-
Performance of the flat plate solar collector operated with water-Al2O3 nanofluid
PublicationThe paper discusses the effect of application of water-Al2O3 nanofluid, as a working fluid, on the efficiency of a flat plate solar collector. The mass concentration of nanoparticles was 0.1%, 0.2% and 0.4%. The tests were conducted for two values of radiation of about 1050 W/m2 and 400 W/m2, and volume flow rates of 60 l/h, 120 l/h and 170 l/h. The efficiency was calculated according to recommendations of the Polish Standard....
-
Performance of the PVT solar collector operated with water-Al2O3 nanofluid
PublicationAn experimental investigation of the hybrid module photovoltaic panel -solar collector (PVT) cooled by water-Al2O3 nanofluids has been conducted. The weight fractions of the nanoparticles were 1% and 3%. Thermal efficiency, power efficiency and overall efficiency have been determined for artificial source of light and sunlight. No noticeable effect of the nanoparticle concentration on the overall efficiency of the PVT module has...
-
PERFORMANCE OF THE PVT SOLAR COLLECTOR OPERATED WITH WATER –AL2O3 NANOFLUID
PublicationAn experimental investigation of the hybrid module photovoltaic panel -solar collector (PVT) cooled by water-Al2O3 nanofluids has been conducted. The weight fractions of the nanoparticles were 1% and 3%. Thermal efficiency, power efficiency and overall efficiency have been determined for artificial source of light and sunlight. No noticeable effect of the nanoparticle concentration on the overall efficiency of the PVT module has...
-
Al(III) and Cu(II) simultaneous foam separation: Physicochemical problems
PublicationSimultaneous removal of Al(III) and Cu(II) from dilute aqueous solutions by ion and precipitate flotation methods is investigated. Influence of the pH of the initial solution, the surface active collector concentration and the gas flow rate on the final removal ratio and the course of ion and precipitate flotations is presented. Results show that simultaneous flotations of Al(OH)3 and Cu(OH)2 insoluble species occur allowing to...
-
Designing control strategies of aeration system in biological WWTP
PublicationThe paper presents the complete design processes of a novel aeration control systems in the SBR (Sequencing Batch Reactor) wastewater treatment plant (WWTP). Due to large energy expense and high influence on biological processes, the aeration system plays a key role in WWTP operation. The paper considers the aeration system for a biological WWTP located in the northeast of Poland. This system consists of blowers, the main collector...
-
Simultaneous Removal of Al, Cu and Zn Ions from Aqueous Solutions Using Ion and Precipitate Flotation Methods
PublicationThis paper presents the results of investigations concerning the simultaneous removal of Al(III), Cu(II), and Zn(II) from dilute aqueous solutions using ion and precipitate flotation methods. The effects of initial solution pH, surface active substance concentration, and the gas velocity on the flotations’ efficiency and course are studied. Experimental results are discussed in terms of physicochemical aspects related to aqueous...
-
Study of Cloud Water Samples Collected over Northern Poland
PublicationThe paper gives the results of the first studies on the chemistry of cloud water collected during 3 mo (Aug.–Oct. 2010) in the free atmosphere over the area to the south of the Tri-City (Gdansk-Sopot-Gdynia) conurbation on the Gulf of Gdansk, Poland. Taken from cumulus, stratus, and stratocumulus clouds by means of an aircraft-mounted collector, the water samples were analyzed for the following contaminants: anions (chlorides,...
-
Storing Matter’technique in SIMS depth profile analysis
PublicationSecondary ion mass spectrometry (SIMS) is a very useful technique for the analysis of layered systems. It is based on the primary ion beam sputtering of solids and mass analysis of the emitted secondary ions. A main limitation of this technique results from the direct quantitative analysis, since the ionization efficiency of a given atom is highly influenced by the neighbouring atoms at the surface. This phenomenon is known as...
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublicationThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
Detection and removal of priority substances and emerging pollutants from stormwater: case study of the Kołobrzeska collector, Gdańsk, Poland
PublicationProgressive urban development affects environmental balance and disrupts the hydrologic cycle, in which rainfall plays a significant role. Since rainwater is considered a valuable resource of the environment, many technical solutions are implemented that enable effective rainwater management. On the other hand, stormwater runoff from urban areas contains numerous (also toxic) substances, and therefore should be properly treated....
-
Metodyka badań rozwojowych nowego typu silników i pomp satelitowych
PublicationResearch and development of new type satellite motors and satellite pumps SM with small geometrical displacement, from 5 to 73 cm3/rev, has been conducted in cooperation with Stosowanie Maszyn company from Katowice (manufacturer of motors and pump SM). The improvement of construction of those machines, especially construction of axial compensation and construction of fluid distribution channels have been the main problem of research...
-
Photovoltaic module temperature stabilization with the use of phase change materials
PublicationThe worldwide growth of photovoltaics (PVs) has formed an exponential curve for more than four decades. During this period of time, PVs have evolved from a pure niche market of small-scale applications towards becoming a mainstream electricity source. The influence of temperature on the electrical parameters of crystalline silicon solar cells and solar modules is well described in the literature. In order to diminish these effects,...
-
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublicationThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Wavelet transform-based approach to defect identification in railway carbon contact strips.
PublicationPantographs of electric rail vehicles are fitted with carbon contact strips, which slide along the contact wire of catenary to provide constant electrical contact. Contact strips are exposed to wear and damages. Using damaged contact strips significantly increases the risk of catenary rupture. Therefore, their technical condition has to be inspected frequently. In previous work a 3D laser scanning system was proposed for recording...
-
Analysis of Measurement Errors in Rail Vehicles’ Pantograph Inspection System
PublicationThe paper presents an approach to evaluation of height measurement errors in laser scanning inspection system. The system, consisting of a laser line generator and a specialized camera, is dedicated to diagnosing carbon contact strips of railway vehicles’ pantographs. While height measurement resolution is easily computable based on system parameters, determining the measurement error is troublesome due to numerous impacts. As...