Search results for: PARALLEL
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 10 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Design of a microrobotic wrist for needle laparoscopic surgery
PublicationThe paper addresses the design of a micro wrist for needle laparoscopic surgery (needlescopy) using MEMS technology and an original 3 degree of freedom, 3D architecture. Advancement in needlescopy drives the development of multi-dof micro-tools 1-2mmin diameter with 3D mobility but standard available fabricationtechniques are for 2.5D structures. The paper discusses thedevelopment steps and design solutions for the realization...
-
Tuning matrix-vector multiplication on GPU
PublicationA matrix times vector multiplication (matvec) is a cornerstone operation in iterative methods of solving large sparse systems of equations such as the conjugate gradients method (cg), the minimal residual method (minres), the generalized residual method (gmres) and exerts an influence on overall performance of those methods. An implementation of matvec is particularly demanding when one executes computations on a GPU (Graphics...
-
Investigation of the Effect of The Temperature and Magnetization Pattern on Flux Density, Instantaneous Torque, Unbalanced Magnetic Forces of a Surface Inset PMM
PublicationElectrical machines utilized in domestic applications such as ceiling fans should have low losses and cost. Permanent magnets are used instead of rotor excitation to reduce losses. Therefore, not only the losses of the rotor winding are eliminated, but also the efficiency of the machine is increased. A surface inset consequent pole (SICP) machine has also been used to reduce costs. Because less magnets are utilized in this structure....
-
Electronic Noses in Medical Diagnostics
PublicationElectronic nose technology is being developed in order to identify aromas in a way parallel to the biologic olfaction. When applied to the field of medicine, such device should be able to identify and discriminate between different diseases. In recent years this kind of approach finds application in medical diagnostics, and especially in disease screening. Despite the fact that devices utilizing chemical sensor arrays are not routinely...
-
Experimental analysis of chip removing system in circular sawing machine
PublicationPaper presents analysis of the process of removing the wood chips generated during the cutting of the material on the circular sawing machine. The attention is focused on the upper cover of the chip removing system. Within the framework of the work a systematic experimental study of pressure distribution in the cover during operation of the selected rotational speed of saw blade with a diameter of 300 mm and 450 mm was carried...
-
A Canonical Switched Capacitor DC-DC Converter. A look at how the historical SC synthesis problem is getting solved
PublicationWe reconsider a solution to the historical problem in switched capacitor (SC) DC-DC converter synthesis. Specifically, we retackle the problem of constructing an SC twophase network realizing arbitrary voltage conversion ratio within rational bounds defined. Theoretical foundations are available in our earlier research [3] where a nonconstructive proof of existence was given. We briefly review and comment on known circuit solutions...
-
Adhesive compliance effect in mode I separation:Profilometry approach
PublicationThe effect of adhesive compliance on the deflection of a loaded, bonded beam was studied using laser profilometry. Experimental data obtained were compared with both Euler-Bernoulli (encastré) and Winkler (one parameter elastic foundation) models. A third, analytical, 2D model, based on shear within the adhesive layer (two parameter elastic foundation), was introduced. Finite element analysis (FEA) was also used to study the effect...
-
Accurate design of pseudoelliptic inline SIW filters with frequency-dependent couplings
PublicationThis paper presents an accurate synthesis method for inline SIW (Substrate Integrated Waveguide) generalized Chebyshev bandpass filters with frequency-dependent couplings. The technique is based on the synthesis of a coupling matrix that takes into account the impedance of the frequency-dependent stub. Thus, a loading effect compensation in adjacent resonators (via resonant frequency adjustment) and coupling elements (via coupling-value...
-
Operational problems of constructed wetland for landfill leachates treatment: case study
PublicationIn the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed.The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent...
-
The role of colloidal and particulate organic compounds in idenitrification and EBPR occurring in a full-scale activatedsludge system
PublicationThe aim of this study was to determine the immediate effects of slowly biodegradable substrates on the denitrification capability andphosphate release/uptake interactions for a full-scale biomass process from the ''Wschod'' wastewater treatment plant (WWTP) in Gdansk (Poland). Since it is hard to distinguish the slowlybiodegradable substrate in a direct way, a novel procedure based on batch experiments was developed and implemented....
-
A self-optimization mechanism for generalized adaptive notch smoother
PublicationTracking of nonstationary narrowband signals is often accomplished using algorithms called adaptive notch filters (ANFs). Generalized adaptive notch smoothers (GANSs) extend the concepts of adaptive notch filtering in two directions. Firstly, they are designed to estimate coefficients of nonstationary quasi-periodic systems, rather than signals. Secondly, they employ noncausal processing, which greatly improves their accuracy and...
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
Identification of nonstationary multivariate autoregressive processes– Comparison of competitive and collaborative strategies for joint selection of estimation bandwidth and model order
PublicationThe problem of identification of multivariate autoregressive processes (systems or signals) with unknown and possibly time-varying model order and time-varying rate of parameter variation is considered and solved using parallel estimation approach. Under this approach, several local estimation algorithms, with different order and bandwidth settings, are run simultaneously and compared based on their predictive performance. First,...
-
VARIANT DESIGNING IN the PRELIMINARY SMALL SHIP DESIGN PROCESS
PublicationShip designing is a complex process, as the ship itself is a complex, technical multi-level object which operates in the air/water boundary environment and is exposed to the action of many different external and internal factors resulting from the adopted technical solutions, type of operation, and environmental conditions. A traditional ship design process consists of a series of subsequent multistage iterations, which gradually...
-
FPGA Acceleration of Matrix-Assembly Phase of RWG-Based MoM
PublicationIn this letter, the field-programmable-gate-array accelerated implementation of matrix-assembly phase of the method of moments (MoM) is presented. The solution is based on a discretization of the frequency-domain mixed potential integral equation using the Rao-Wilton-Glisson basis functions and their extension to wire-to-surface junctions. To take advantage of the given hardware resources (i.e., Xilinx Alveo U200 accelerator card),...
-
Distance measurement by the low coherent interferometer
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
GNIAZDA PRZEDSIĘBIORCZOŚCI W STREFIE PODMIEJSKIEJ METROPOLII
PublicationProblem suburbanizacji jest wciąż aktualny w analizach rozwoju miast. Przybiera często formy spontanicznego rozlewania się miast (urban sprawl). Badacze tego problemu skupiają się przeważnie na rozwoju funkcji mieszkaniowej w strefach podmiejskich. Specyficzny charakter polskiego procesu suburbanizacji polega na równoległym rozwoju klasycznej suburbanizacji osiedleńczej oraz rozwoju mikro- oraz małych i średnich przedsiębiorstw....
-
Effect of asymmetric fluid flow distribution on flow boiling in a microchannel heat sink – An experimental investigation
PublicationFlow boiling in microchannels is emerging as an exclusive cooling solution for miniaturized high-power electronic devices alongside having other high heat flux applications. Size miniaturization at microscale strangely increases heat transfer performance as well as flow boiling instabilities. Many flow boiling instabilities are interrelated and result from imperfect hydrodynamic conditions. One of such problems is flow maldistribution among...
-
Images of the Seabed of the Gulf of Gdansk Obtained by Means of the Parametric Sonar
PublicationThe main goal of this paper is to present results of the experimental investigation of the seabed by means of parametric echosounder in the form of chosen images. The phenomena of nonlinear interaction between two parallel beams of high intensity gives as a results very narrow beam of low frequency wave, that enables to penetrate the sea bottom. The first step of our investigations was calibration of all the elements of the measuring...
-
Unraveling a novel microwave strategy to fabricate exposed {001}/{101} facets anatase nanocrystals: Potential for use to the elimination of environmentally toxic metronidazole waste
PublicationThis study present a novel microwave strategy to fabricate highly active anatase particles, exposing {101} and {001} facets. Microwave treatment time was shown to determine the growth of crystals in a certain direction. To the best of our knowledge, it is the first report revealing that the contact time of TiO2 crystals with fluorine ions during the microwave process affects the formed morphology, in particular exposed facets ratio....
-
The effect of UV-C irradiation on lipids and selected biologically active compounds in human milk
PublicationThe effect of UV-C irradiation of human milk on lipid oxidation, content of antioxidants (vitamin C and catalase, CAT) and bactericidal compounds (lysozyme), as well as the total antioxidant capacity (TAC), of the breast milk was investigated. In parallel, the extent of inactivation of some bacteria was also determined. UV-C at doses from 85 to 740 J L−1 caused total inactivation of Escherichia coli and Staphylococcus aureus, but...
-
Bioaugmentation of a sequencing batch reactor with Archaea for the treatment of reject water
PublicationIn this study, the bioaugmentation of a sequencing batch reactor (SBR) for the treatment of reject water from wastewater treatment plant was evaluated. For the bioaugmentation step a product containing an enrichment of microorganisms from the Archaea domain was used to enhance the performance of the reactor for treating reject water. The experiment was carried out in two parallel lab-scale sequencing batch reactors. The first one...