Filters
total: 3755
-
Catalog
- Publications 2427 available results
- Journals 5 available results
- Conferences 4 available results
- People 26 available results
- Inventions 1 available results
- Projects 1 available results
- Laboratories 1 available results
- Research Equipment 4 available results
- e-Learning Courses 128 available results
- Events 9 available results
- Offers 1 available results
- Open Research Data 1148 available results
displaying 1000 best results Help
Search results for: EMISSION TEST CHAMBERS
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Model matematyczny strat objętościowych ściskania oleju hydraulicznego w pompie wyporowej o zmiennej wydajności
PublicationCelem pracy było stworzenie możliwości oceny strat objętościowych wynikających ze ściskania oleju hydraulicznego w komorach roboczych wysokociśnieniowej pompy wyporowej o zmiennej wydajności na obrót wału. Straty objętościowe ściskania oleju muszą być określone jako funkcje tych samych parametrów, w zależności od których ocenione są straty objętościowe przecieków oleju w komorach, wynikające z jakości rozwiązania konstrukcyjnego...
-
The influence of settable parameters of switching gasoline/LPG on exhaust toxic emissions
PublicationThe main objective of the studies shown in the paper was to develop a proper strategy for settable parameters of ECU to decrease total emission of toxic components in composition of exhaust during a cold start phase. The experimental research has been performed for engine running at idle and for engine running on the chassis dynamometer (performing European Driving Test NEDC).
-
Beata Krawczyk-Bryłka dr
PeoplePsycholog, doktor nauk humanistycznych w dziedzinie zarządzania, adiunkt w Katedrze przedsiębiorczości. 2018 - 2021: Kierownik projektu NCN: „Efektuacyjny model zespołu przedsiębiorczego. Jak działają przedsiębiorcze zespoły odnoszące sukces" od 2016: Quality Standards Lead filaru People management & personal development na studiach MBA Politechniki Gdańskiej 2008 – 2012: Prodziekan ds kształcenia Wzydziału Zarządzania i Ekonomii...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
High frequency test measurements on physical model of power transformer with use of FRAX analyzer Streszczenie. W niniejszym artykule przedstawiono pomiary testowe SFRA wykonane na modelu fizycznym transformatora elektroenergetycznego
Publication -
Patryk Ziółkowski dr inż.
PeoplePatryk Ziolkowski is a graduate of the Faculty of Civil and Environmental Engineering at the Gdansk University of Technology, specializing in Building and Engineering Structures. He works as an Assistant Professor at the Department of Engineering Structures. He participated in international projects, including projects for the Ministry of Transportation of the State of Alabama (2015), he is also the winner of a grant from the Kosciuszko...
-
TH-D-BRB-06: Assessment of Proton Beam In-Vivo Dose Verification by Directly Comparing Doses Measured in Tissue-Equivalent Polymer Gels to Proton-Activated Positron-Emission Distributions in the Gels Post Irradiation
Publication -
Badania emisji lotnych związków organicznych podczas nalewu asfaltu do autocystern oraz budowy dróg asfaltowych = Emission of volatile organic compounds from road bitumen during tank filling and road paving
PublicationOstatnio ma miejsce dyskusja poświęcona emisji lotnych związków organicznych towarzyszącej "niehermetycznemu" nalewowi asfaltów oraz budowie dróg asfaltowych. Asfalt naftowy wytwarzany jest poprzezutlenianie pozostałości z destylacji próżniowej. Zarówno na etapie destylacji próżniowej ropy naftowej, jak również w reaktorach utleniania asfaltu może dochodzić do przegrzewania wsadu na elementach grzejnych instalacji, a w wyniku zachodzi...
-
Comparison of the powers of energy losses in a variable capacity displacement pump determined without or with taking into account the power of hydraulic oil compression
PublicationPowers of energy losses in a variable capacity displacement pump are compared with or without taking into account the power of hydraulic oil compression. Evaluation of power of liquid compression in the pump was made possible by the use of method, proposed by the Author, of determining the degree of liquid aeration in the pump. In the method of determining the liquid aeration in the pump and of powers of volumetric losses of liquid...
-
Multi-Taper-Based Automatic Correction of Non-Anechoic Antenna Measurements
PublicationPrototype measurements belong to the key steps in the development of antenna structures. Although accurate validation of their far-field performance can be realized in dedicated facilities, such as anechoic chambers, the high cost of their construction and maintenance might not be justified if the main goal of measurements is to support teaching or low-budget research. Instead, they can be performed in non-anechoic conditions and...
-
Environmental Protection in Energetics, W, E, sem.01, zimowy 22/23
e-Learning CoursesThe principle of sustainable development. Non-renewable and renewable energy sources. Environmental aspects of the use of different energy sources. Atmospheric pollution. Methods of reducing the emission of pollutants into the atmosphere. Waste and hazardous waste. Water and Wastewater. Legal aspects of environmental protection.
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublicationOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (30wt.%YSZ)
Open Research DataThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 30wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (10wt.%YSZ)
Open Research DataThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 10wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.
-
The XRD diffraction pattern of interdiffusion test in the CLO-NiO-YSZ system (20wt.%YSZ)
Open Research DataThe dataset includes the XRD pure diffraction pattern of the interdiffusion system consisting of CLO (Ce0.8La0.2O2), NiO and 8YSZ (8mol.% Y2O3 stabilized ZrO2). The mixture contains equal amounts of CLO and NiO as well as 20wt.% 8YSZ. Samples were sintered at 1400 oC. The reaction between CLO and YSZ is visible.
-
Demonstrator testera wbudowanego BIST dla układów w pełni różnicowych
PublicationPrzedstawiono demonstrator testera wbudowanego, przeznaczony do pracy na stanowisku dydaktycznym w laboratorium z przedmiotu Zaawansowane Metody Pomiarowe i Diagnostyczne. Na stanowisku studenci zapoznają się z technologią BIST (ang. Built-In Self-Test), która jest przykładem wdrożenia strategii projektowania dla testowania.
-
Low-Cost Open-Hardware System for Measurements of Antenna Far-Field Characteristics in Non-Anechoic Environments
PublicationExperimental validation belongs to the most important steps in the development of antenna structures. Measurements are normally performed in expensive, dedicated facilities such as anechoic chambers, or open-test sites. A high cost of their construction might not be justified when the main goal of antenna verification boils down to demonstration of the measurement procedure, or rough validation of the simulation models used for...
-
Influence of pH and low-molecular weight organic compounds in solution on selected spectroscopic and analytical parameters of flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) for the optical emission spectrometric (OES) determination of Ag, Cd, and Pb
Publication -
Determination of the theoretical and actual working volume of a hydraulic motor
PublicationA new methodology of determination of the theoretical and actual working volume of a hydraulic motor based on the characteristics of the delivered flow rate into hydraulic motor vs. the rotational speed at a constant pressure drop in the working chambers is described in this paper. A new method of describing the delivered flow rate into a motor per one shaft revolution as a nonlinear function of the pressure drop in the motor working...
-
Low temperature cracking equipment: Termal Stress Restrained Specimen Test (TSRST); Uniaxial Tensile Strength Test (UTST); Tensile Creep Test (TCT); Relaxation Test (RT);
Research Equipment -
The basics of design and experimental tests of the commutation unit of a hydraulic satellite motor
Publicationhe article presents an analytical method to design the commutation unit in a hydraulic satellite motor. It is shown that the size of the holes feeding the working chambers and their location on the plates closing those chambers depends on the geometrical dimensions of the working mechanism. The overlap in the commutation unit depends on the rotational speed range. It is demonstrated that the geometrical dimensions of the commutation...
-
Magdalena Brzozowska-Woś dr hab. inż.
PeopleMagdalena Brzozowska-Woś is a graduate of the Faculty of Management and Economics of the Gdańsk University of Technology (specialization: management systems). She is also a graduate of Postgraduate Studies in Advertising (Faculty of Management and Economics, GUT) and Postgraduate Studies in Public Relations (SWPS University of Humanities and Social Sciences). In the years 2000-2003, she cooperated with Panorama Internet sp. z o....
-
Badania mieszanek mineralno-asfaltowych w niskiej temperaturze
PublicationW artykule przedstawiono metody badań w niskiej temperaturze betonu asfaltowego przeznaczonego do warstwy ścieralnej. Przedstawione zostały wyniki badań dla 4 różnych metod badawczych: zginania, pełzania, pośredniego rozciągania oraz rozciągania termicznego przy ograniczonym odkształceniu (test TSRST). Próbki betonu asfaltowego były przygotowywane w laboratorium z wykorzystaniem 3 rodzajów asfaltów: asfaltu zwykłego, asfaltu modyfikowanego...
-
Porównanie mocy strat energetycznych w pompie wyporowej o zmiennej wydajności określonych bez uwzględnienia bądź z uwzględnieniem mocy ściskania oleju hydraulicznego
PublicationPorównano moce strat energetycznych w pompie wyporowej o zmiennej wydajności, określone bez uwzględnienia bądź z uwzględnieniem mocy ściskania oleju hydraulicznego. Ocena mocy ściskania cieczy w pompie stała się możliwa dzięki zastosowaniu, zaproponowanej przez autora, metody określenia stopnia zapowietrzenia cieczy w pompie. W metodzie określenia stopnia zapowietrzenia cieczy w pompie oraz w ocenie mocy strat objętościowych ściskania...
-
Laboratory station for research of the innovative dry method of exhaust gas desulfurization for an engine powered with residual fuel
PublicationContemporary methods of exhaust gas desulfurization in marine engines are all expensive methods (4-5 million euro). This is, among other reasons, due to the limited market audience, but primarily due to the monop-olized position of manufacturers offering fabrication and assembly of this type of marine ship installations. Proposed as part of a research project financed by the Regional Fund for Environmental Protection and Maritime...
-
Kacper Donat mgr inż.
PeopleSuper sprawa!
-
Influence of geometrical and operational parameters on tooth wear in the working mechanism of a satellite motor
PublicationThis article describes the phenomena affecting the wear of the rotor of the working mechanism in a hydraulic satellite motor. The basic geometrical relationships that allow the calculation of the coordinates of the points of contact between the satellite and the rotor and the curvature are presented. A method for calculating the number of contacts of the satellite teeth with the rotor teeth and of the satellite teeth with the curvature...
-
Wytwarzanie i modyfikacja powierzchni porowatych struktur tytanowych przeznaczonych na implanty
PublicationCelem pracy było wytworzenie stopu Ti-13Nb-13Zr z wykorzystaniem technologii selektywnego topienia laserowego (SLM) oraz jego biofunkcjonalizacja za pomocą utleniania mikrołukowego (MAO), a następnie określenie wpływu parametrów procesowych na właściwości otrzymanych materiałów pod kątem ich zastosowania na implanty. Oceniono wpływ napięcia, natężenia i czasu procesu MAO przeprowadzanego w elektrolicie zawierającym wapń i fosfor...
-
Piotr Konieczka prof. dr hab. inż.
People -
The luminescence study of Ga2–x(Al0.68In0.32)xO3:Cr3+ coumpounds.
Open Research DataNear-infrared (NIR) phosphor-converted light-emitting diodes (pc-LEDs) are a highly efficient perspective NIR light source, with application hindered by a narrow emission band. In this work, we broaden the emission of a new series of NIR phosphors by controlling crystal structure disorder through cation cosubstitution. By substituting Ga3+ with (Al0.68In0.32)3+,...
-
Problem of inconsistent and contradictory judgements in pairwise comparisonmethod in sense of AHP
PublicationThe aim of this paper is to show the relationship between inconsistent and contradictory matrices of data obtained as a result of the pairwise comparison of factors in the sense of the Analytic Hierarchy Process. The consistency check is performed to ensure that judgements are neither random nor illogical. This paper shows that even if a matrix will pass a consistency test successfully, it can be contradictory. Moreover an algorithm...