Search results for: WWTP, PROCESS CONTROL , ASM, DIAGNOSIS
-
Process control of leakages in refinery reforming plant by means of Normal Phase High Performance Liquid Chromatography (HPLC)
PublicationPraca dotyczy zbadania możliwości, opracowania nowej procedury badawczej oraz dokonania oznaczeń ¬m-krezolu w strumieniu produktu z procesu reformingu katalitycznego techniką wysokosprawnej chromatografii cieczowej w układzie faz normalnych, z detektorem spektrofotometrycznym typu DAD (NP-HPLC-UV-VIS/DAD). Opracowana procedura stanowi alternatywę dla innych procedur wykorzystujących klasyczne techniki analityczne, albo wykorzystanie...
-
Investigation of the Process of Automatic Control of Current Polarity Reversal in the Conditions of Hybrid Technology of Electrochemical Processing of Corrosion-Resistant Steels
Publication -
Cytokine TGFβ Gene Polymorphism in Asthma: TGF-Related SNP Analysis Enhances the Prediction of Disease Diagnosis (A Case-Control Study With Multivariable Data-Mining Model Development)
Publication -
A stochastic approach for the solution of single and multi – objective optimisation problems of biological processes in sequencing batch reactor
PublicationThis paper investigates the impact of implementing single and multi-optimisation solutions on the biological treatment process in a sequencing batch reactor (SBR). The research is based on a case study of the water resource recovery facility (WRRF) in Swarzewo, Northern Poland. The paper introduces the adaptive extremum seeking control (ESC) method for dissolved oxygen (DO) concentration control and places it in a layered control structure....
-
Replicating DNA by cell factories: roles of central carbon metabolism and transcription in the control of DNA replication in microbes, and implications for understanding this process in human cells
Publication -
Employment of a Nonlinear Adaptive Control System for Improved Control of Dissolved Oxygen in Sequencing Batch Reactor
PublicationA proper control in a complex system, such as Wastewater Treatment Plant (WWTP) with each year is becoming increasingly important. High quality control can minimize an environmental impact as well as reduce operational costs of the WWTP. One of the core issues is providing adequate dissolved oxygen (DO) concetration for microorganisms used in a treatment process. An aeration process of the wastewater realised by an system consisting...
-
Supervised model predictive control of wastewater treatment plant
PublicationAn optimizing control of a wastewater treatment plant (WWTP), allowing for cost savings over long time period and fulfilling effluent discharge limits at the same time, requires application of advanced control techniques. Model Predictive Control (MPC) is a very suitable control technology for a synthesis of such a truly multivariable controller that can handle constraints and accommodate model-based knowledge combined with hard...
-
Maciej Niedostatkiewicz dr hab. inż.
People -
Takagi-Sugeno Fuzzy Model of Dissolved Oxygen Concentration Dynamics in a Bioreactor at WWTP
PublicationThe importance of dissolved oxygen concentration controlinaerationtanksofabioreactoratflow-throughwastewater treatment plant (WWTP) can easily be justified by technological requirements as well as simple economics. Firstly, appropriate levels of dissolved oxygen concentration are essential for the vitality of microorganisms that comprise the bioreactor. Secondly, the costs of dissolved oxygen concentration control related to the...
-
Intelligent PI controller and its application to dissolved oxygen tracking problem
PublicationThe paper addresses design, calibration, implementation and simulation of the intelligent PI controller used for dissolved oxygen (DO) tracking in wastewater treatment plant (WWTP). The calibration process presented in this paper utilizes both engineering and scientific methods. Verification of the control system design method was obtained via simulation experiments.
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublicationThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
Supervisory fuzzy control system for biological processes in sequencing wastewater batch reactor
PublicationThe paper proposes the design of the supervisory heuristic fuzzy control system applied to a Sequencing Batch Reactor (SBR) in the Wastewater Treatment Plant (WWTP). Based on real data records and the biological process and aeration system models, a control system for biological processes has been designed. The supervisory control system performs management of the reactor work cycle, determines the phase length, controls the sludge...
-
The Simulation of Activated Sludge System for Optimization of Predictive Aeration at Large WWTP
PublicationEffective use of biodegradable substrates as an internal carbon sources (ICS) for denitrification and EBPR and predicting performance of aeration systems during nitrification in activated sludge bioreactors, may be useful in realization the sustainable development by potentially saving energy consumption at WWTPs. A large number of WWTPs use activated sludge systems with an integrated removal of carbon, nitrogen and phosphorus...
-
Application of adjusted subpixel method (ASM) in HRCT measurements of the bronchi in bronchial asthma patients and healthy individuals
PublicationBackground: Recently, we described a model system which included corrections of high-resolution computedtomography (HRCT) bronchial measurements based on the adjusted subpixel method (ASM).Objective: To verify the clinical application of ASM by comparing bronchial measurements obtained bymeans of the traditional eye-driven method, subpixel method alone and ASM in a group comprised ofbronchial asthma patients and healthy individuals.Methods:...
-
A new approach to designing control of dissolved oxygen and aeration system in sequencing batch reactor by applied backstepping control algorithm
PublicationThe Wastewater Treatment Plant (WWTP) is a very complex system, due to its nonlinearity, time-variance, and multiple time scales in its dynamics among others. The most important control parameter in a WWTP is the Dissolved Oxygen (DO) concentration. The tracking problem of the DO concentration is one of the most fundamental issues in biological wastewater treatment. Proper DO concentration control is necessary to achieve adequate...
-
Improving the energy balance in wastewater treatment plants by optimization of aeration control and application of new technologies
PublicationThe methods to improve the energy balance of a wastewater treatment plant (WWTP) by optimization of aeration process control and application of innovative nitrogen removal technologies were overviewed in the study. The control of aeration based on the ABAC (Ammonia-Based Aeration Control) system allows not only for significant savings in electricity consumption, but it can also increase the efficiency of the denitrification process....
-
Jolanta Łopatowska dr inż.
PeopleJolanta Łopatowska, assistant professor at the Department of Management Engineering and Quality at the Faculty of Management and Economics, is a graduate of the Faculty of Electronics at Gdańsk University of Technology and Institute of Organization and Design of Production Systems at Gdańsk University of Technology. She obtained Ph.D. degree in the discipline of Economic Science. Her scientific and research interests focus on organizationally...
-
State and control system variables sensitivity to rotor asymmetry in the induction motor drive
PublicationThe aim of this paper is to undertake analysis and comparison of the closed-loop and sensorless control systems sensitivity to the broken rotor for diagnostic purposes. For the same vector control system induction motor drive analysis concerning operation with the asymmetric motor, broken rotor fault handling and operation were investigated. Reliability, range of stable operation, fault symptoms and application of diagnosis methods...
-
Phong B. Dao D.Sc., Ph.D.
PeoplePhong B. Dao received the Engineer degree in Cybernetics in 2001, the M.Sc. degree in Instrumentation and Control in 2004, both from Hanoi University of Science and Technology in Vietnam, and the Ph.D. degree in Control Engineering in 2011 from the University of Twente, the Netherlands. In May 2020, Dr. Dao received the degree of D.Sc. (Habilitation) in Mechanical Engineering from the AGH University of Science and Technology, Poland....
-
Rapid on-line method of wastewater parameters estimation by electronic nose for control and operating wastewater treatment plants toward Green Deal implementation
PublicationIn order to comply with legal regulations related to wastewater quality, the operational mode of facilities at wastewater treatment plant (WWTP) should be properly adjusted according to parameters of influents, however it is very difficult without frequently performed measurements. Currently there are known many techniques and devices for assesment of wastewater parameters such as chemical oxygen demand, biochemical oxygen demand,...
-
Broken rotor symptoms in the sensorless control of induction machine
PublicationThe purpose of this paper is to investigate the need for a universal method for sensorless controlled induction motor drive diagnosis. The increasing number of sensorless control systems in industrial applications require a universal method for the drive diagnosis, which provides reliable diagnostic reasoning independent of control system structure and state variables measurement or estimation method.Simulations and experimental...
-
Computer Simulation in Predicting Biochemical Processes and Energy Balance at WWTPs
PublicationNowadays, the use of mathematical models and computer simulation allow analysis of many different technological solutions as well as testing various scenarios in a short time and at low financial budget in order to simulate the scenario under typical conditions for the real system and help to find the best solution in design or operation process. The aim of the study was to evaluate different concepts of biochemical processes and...
-
Fault detection and diagnostics of complex dynamic systems using Gaussian Process Models - nuclear power plant case study
PublicationThe article examines the use of Gaussian Process Models to simulate the dynamic processes of a Pressurized Water nuclear Reactor for fault detection and diagnostics. The paper illustrates the potential of Gaussian Process Models as a tool for monitoring and predicting various fault conditions in Pressurized Water nuclear Reactor power plants, including reactor coolant flow and temperature variations, deviations from nominal working...
-
Risk Analysis by a Probabilistic Model of the Measurement Process
PublicationThe aim of the article is presentation of the testing methodology and results of examination the probabilistic model of the measurement process. The case study concerns the determination of the risk of an incorrect decision in the assessment of the compliance of products by measurement. Measurand is characterized by the generalized Rayleigh distribution. The model of the meas-urement process was tested in parallel mode by six risk...
-
Adaptive stochastic and hybrid nonlinear optimization algorithms for improving the effectiveness of the biological processes at WWTP
PublicationWastewater treatment plays an important factor in the modern world. Insufficient treatment may result in environmental pollution which can further lead to disasters and diseases. However, processes that take place inside wastewater treatment plants (WWTP) are highly complex in nature, therefore it is difficult to design an efficient, optimal control system. The problem regarding biochemical reactions inside Sequential Batch Reactor...
-
Optimised allocation of actuators for DWDS
PublicationThis paper addresses the problem of actuators’ allocation within networked structured system, namely allocation of disinfectant booster stations within Drinking Water Distribution System (DWDS), under receding horizon optimised control – Model Predictive Control (MPC) to be exact. The allocation task is kept within dynamic multiobjective optimisation framework. The MPC is defined as a single objective predictive operator. Two numerical...
-
Robust asymptotic super twisting sliding mode observer for non-linear uncertain biochemical systems
PublicationThe problem of state estimation (reconstruction of the state vector) for a given class of biochemical systems under uncertain system dynamics has been addressed in this paper. In detail, the bioreactor at a water resource recovery facility represents the considered biochemical systems. The biochemical processes taking place in the bioreactor have been modelled using an activated sludge model. Based on this model, an appropriate...
-
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublicationA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
Broken rotor bar impact on sensorless control of induction machine
PublicationThe aim of the research is analysis of the sensorless control system of induction machine with broken rotor for diagnostic purposes. Increasing popularity of sensorless controlled variable speed drives requires research in area of reliability, range of stable operation, fault symptoms and application of diagnosis methods. T transformation (Cunha et al.,2003) used for conversion of instantaneous rotor currents electrical circuit...
-
Fast Real-Time RDFT- and GDFT-Based Direct Fault Diagnosis of Induction Motor Drive
PublicationThis paper presents the theoretical analysis and experimental verification of a direct fault harmonic identification approach in a converter-fed electric drive for automated diagnosis purposes. On the basis of the analytical model of the proposed real-time direct fault diagnosis, the fault-related harmonic component is calculated using recursive DFT (RDFT) and Goertzel DFT (GDFT), applied instead of the full spectrum calculations...
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublicationThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...
-
Innovations in Wastewater Treatment: Harnessing Mathematical Modeling and Computer Simulations with Cutting-Edge Technologies and Advanced Control Systems
PublicationThe wastewater treatment landscape in Central Europe, particularly in Poland, has undergone a profound transformation due to European Union (EU) integration. Fueled by EU funding and rapid technological advancements, wastewater treatment plants (WWTPs) have adopted cutting-edge control methods to adhere to EU Water Framework Directive mandates. WWTPs contend with complexities such as variable flow rates, temperature fluctuations,...
-
Sewage sludge pretreatment by low thermal disintegration for better efficacy of sludge digestion process
PublicationThe wastewater water treatment plant (WWTP) sector and it is developing technologies strive to be implement circular economy. The methane production from the sludge digestion process constitute promising source of the renewable energy for WWTP and approaching circular economy assumptions. For this reason, the objective of the study was to examine the modification of sludge characteristics due to the low temperature pretreatment....
-
Modelling of Nuclear Power Plant Steam Turbine
PublicationThe paper describes the approach to a Nuclear Power Plant steam turbine modelling which would enable on-line optimal process control (model based) and diagnosis over wide range of operating conditions caused by changing power demand. Presented model is static, multivariable and nonlinear. Such model enables analyzing the heat cogeneration aspects. Developed model is validated and verified by using archive data gained from researches...
-
Modelling of Nuclear Power Plant Steam Turbine
PublicationThe paper describes the approach to a Nuclear Power Plant steam turbine modelling which would enable on-line optimal process control (model based) and diagnosis over wide range of operating conditions caused by changing power demand. Presented model is static, multivariable and nonlinear. Such model enables analyzing the heat cogeneration aspects. Developed model is validated and verified by using archive data gained from researches...
-
Intelligent system supporting diagnosis of malignant melanoma
PublicationMalignant melanomas are the most deadly type of skin cancers. Early diagnosis is a key for successful treatment and survival. The paper presents the system for supporting the process of diagnosis of skin lesions in order to detect a malignant melanoma. The paper describes the development process of an intel-ligent system purposed for the diagnosis of malignant melanoma. Presented sys-tem can be used as a decision support system...
-
A comprehensive approach to SBR modelling for monitoring and control system design
PublicationThe aim of this research is to provide a comprehensive description of the Sequencing Batch Reactor (SBR) modelling for monitoring, control, and plant operational optimisation validation. The paper provides a detailed modelling of the SBR, its components and constituent processes. For this purpose, the mass balance principle and continuity equations were provided with a reactive term implemented using Activated Sludge Model (ASM)....
-
The role of slowly biodegradable substrate in a full-scale biological nutrient removal activated sludge systems
PublicationThis paper contains futher results obtained at ''Wschod'' WWTP in Gdańsk under transient conditions (spring season) and comparation of similar experiments carried out at a recently upgraded ''Debogorze'' WWTP in Gdynia. The removal of colloidal and particulate fractions resulted in similar effects (reduced process rates) at both plants. For example, the initial denitrification rates (NUR1) were up to 30% lower during the ''conventional''...
-
Jakub Miler dr inż.
PeopleAcademic career: 2000: Master of Science - Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics, thesis "Computer system for supporting risk management in a software engineering project", supervisor prof. Janusz Górski 2005: PhD - Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics, thesis "A Method of Software Project Risk Identification and Analysis",...
-
Stochastic optimisation algorithm for optimisation of controller parameters for control of dissolved oxygen in wastewater treatment plant
PublicationWastewater treatment plants (WWTPs) are very important facilities for mankind. They enable the removal and neutralisation of man-made pollutants. Therefore, it is important for wastewater treatment plants to operate as efficiently as possible so that the level of pollutants in the treated wastewater meets specific requirements. This paper concerns the design of a hierarchical nonlinear adaptive control system for dissolved oxygen...
-
Denitrifcation rate in the mainstream deammonification
PublicationThe conventional processes of biological nitrogen removal based on nitrification and denitrification does not fit properly into the concept of the circular economy. As the alternative one should consider the deammonification process, which is a combination of partial nitrification (nitritation) and Anammox processes. It consists of removing ammonium nitrogen from wastewater under anaerobic conditions by a group of autotrophic microorganisms....
-
Development of a tropical disease diagnosis system using artificial neural network and GIS
PublicationExpert systems for diagnosis of tropical diseases have been developed and implemented for over a decade with varying degrees of success. While the recent introduction of artificial neural networks has helped to improve the diagnosis accuracy of such systems, this aspect is still negatively affected by the number of supported diseases. A large number of supported diseases usually corresponds to a high number of overlapping symptoms,...
-
Porównanie efektywności biologicznego usuwania związków biogennych w procesach MUCT i A2/O na przykładzie oczyszczalni w Gdańsku
PublicationThis paper presents a comparison of the efficiency of nutrient removal in two different technological systems functioning in WWTP in Gdansk. The upgrade was necessary in order to adjust the parameters of wastewater treatment to more stringent requirements for Total Nitrogen removal (Total Nitrogen concentration < 10 mg/L). Since 2012 the biological treatment line has operated based on modified A2/O process instead of MUCT process....
-
Two-Step Model Based Adaptive Controller for Dissolved Oxygen Control in Sequencing Wastewater Batch Reactor
PublicationDissolved Oxygen (DO) concentration is a crucial parameter for efficient operation of biological processes taking place in the activated sludge Wastewater Treatment Plant (WWTP). High-quality DO control is difficult to achieve because of complex nonlinear behavior of the plant and substantial influent disturbances. A method to improve the Direct Model Reference Adaptive Control (DMRAC) technology in application to DO tracking for...
-
Iwona Nowakowska dr
PeopleAssistant Professor at The Maria Grzegorzewska University Institute of Psychology. Graduate of Psychology (University of Warsaw, 2019), and PhD in this field (Maria Grzegorzewska University, 2022). Conducted research in the fields of: social and clinical psychology and individual differences. Her current research activity concentrates on prosociality (volunteering, philanthropy, socially responsible behaviors) and their correlates. She...
-
Strategies for Achieving Energy Neutrality in Biological Nutrient Removal Systems – a Case Study of the Slupsk WWTP (northern Poland)
PublicationThe paper presents a model-based evaluation of technological upgrades on the energy and cost balance in a large biological nutrient removal wastewater treatment plant (WWTP) in the city of Slupsk (northern Poland). The proposed upgrades include chemically enhanced primary sludge removal and reduction of the nitrogen load in the deammonification process employed for reject water treatment. Simulations enabled to estimate the increased...
-
Strategies for achieving energy neutrality in biological nutrient removal systems - a case study of the Slupsk WWTP (northern Poland)
PublicationThe paper presents a model-based evaluation of technological upgrades on the energy and cost balance in a large biological nutrient removal wastewater treatment plant (WWTP) in the city of Slupsk (northern Poland). The proposed upgrades include chemically enhanced primary sludge removal and reduction of the nitrogen load in the deammonification process employed for reject water treatment. Simulations enabled to estimate the increased...
-
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublicationInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Paweł Raczyński dr inż.
PeoplePaweł Raczyński received the M.Sc. degree in automatics and computer science from Gdańsk University of Technology, Gdańsk, Poland, in 1977. He has been with Electronics, Telecommunication and Informatics Faculty, Gdańsk University of Technology since 1977. In 1986 he received the Ph.D. degree from the same faculty. His research deals with the issues of construction of control systems and technical diagnostics, in particular diagnosis...