Filters
total: 1539
-
Catalog
- Publications 1200 available results
- Journals 50 available results
- Conferences 4 available results
- Publishing Houses 4 available results
- People 3 available results
- Inventions 7 available results
- Projects 6 available results
- Research Teams 16 available results
- Research Equipment 2 available results
- e-Learning Courses 12 available results
- Events 3 available results
- Open Research Data 232 available results
displaying 1000 best results Help
Search results for: tem
-
The dying medium temperature impact on the final moisture content of pine wood at constant drying time
PublicationThe results of final moisture content of pine wood (Pinus sylvestris L.) after drying process are presented. The wood in the experiments was taken from the northern part of Pomeranian region in Poland. The drying process was performed in the experimental chamber equipped with the micro-jet heat exchanger. The air at temperatures of 40°C, 60°C, 80°C, 100°C and 120°C with relative humidity about 60% and atmospheric pressure was the...
-
Influence of High Temperature Oxidation on Hydrogen Absorption and Degradation of Zircaloy-2 and Zr 700 Alloys
PublicationThe present research was aimed at determining the effects of the oxide layers on hydrogen absorption, microstructure and mechanical properties of the Zircaloy- 2 and Zr 702 alloys. The oxidation was made at 350 °C, 700 °C and 900 °C for 10 to 30 min in laboratory air, followed by hydrogen cathodic charging for 72 h and annealing at 400 °C for 4 h. The slow strain rate tests were carried out on oxidized, charged and annealed specimens. The...
-
LABORATORY STAND FOR INVESTIGATIONS OF THE QUICK - CHANGING TEMPERATURE OF GAS FLOWING IN THE PISTON COMPRESSOR OUTLET CHANNEL
PublicationThis paper presents a laboratory stand, created as a part of work on the doctor dissertation, intended for investigation of heat and flow processes taking place in the Espholin H3S piston compressor outlet channel. The test stand elements and their configuration within the stand are described. Discussed are also problems connected with the quick-changing measurement technique, solutions which have been proposed so far in that technology...
-
Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS2 devices
PublicationWe report on the depinning of nearly commensurate charge-density waves in 1T-TaS2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS2 is not accompanied by an observable abrupt increase in electric current—in striking contrast...
-
Glass-ceramic sealants and steel interconnects: accelerated interfacial stability and reactivity tests at high temperature
PublicationHigh-temperature reactions between glass-ceramic sealants and Fe-Cr alloy interconnects may lead to the formation of undesirable phases, and consequently degradation of solid oxide fuel/electrolyser devices. In this work, three different glass-ceramic sealants (Na-containing, Ba-containing, Sr-containing compositions) and Fe22Cr stainless steel powders (raw and pre-oxidised) are considered in order to test their chemical reactivity...
-
Fatigue life improvement using low transformation temperature weld material with measurement of residual stress
PublicationWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
The vibration-based assessment of the influence of elevated temperature on the condition of concrete beams with pultruded GFRP reinforcement
PublicationConcrete beams reinforced with glass fiber reinforced polymer (GFRP) bars subjected to elevated temperature have been experimentally studied. The influence of high temperatures on GFRP-reinforced concrete beams condition has been check both, destructively and nondestructively. The nondestructive tests foresaw vibration-based tests to obtain the natural frequency values after exposure to varying temperatures. The vibration-based...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
The Influence of Low-Temperature Disintegration on the Co-Fermentation Process of Distillation Residue and Waste-Activated Sludge
Publication: Innovative low-temperature disintegration (process temperature 55 ◦C and oxygen concentration 0.2 mg/dm3 ) can be an economically rational technology to intensifying energy production from renewable sources. The proposed process can achieve a degree of disintegration—under optimal conditions—of about 50%, which is excellent when compared with other methods of feed pre-treatment. The low-temperature disintegration of distillation...
-
High-Temperature Oxidation of Heavy Boron-Doped Diamond Electrodes: Microstructural and Electrochemical Performance Modification
PublicationIn this work, we reveal in detail the effects of high-temperature treatment in air at 600 °C on the microstructure as well as the physico-chemical and electrochemical properties of boron-doped diamond (BDD) electrodes. The thermal treatment of freshly grown BDD electrodes was applied, resulting in permanent structural modifications of surface depending on the exposure time. High temperature affects material corrosion, inducing...
-
Influence of CeO2 and TiO2 Particles on Physicochemical Properties of Composite Nickel Coatings Electrodeposited at Ambient Temperature
PublicationThe Ni-TiO2 and Ni-CeO2 composite coatings with varying hydrophilic/hydrophobic characteristics were fabricated by the electrodeposition method from a tartrate electrolyte at ambient temperature. To meet the requirements of tight regulation by the European Chemicals Agency classifying H3BO3 as a substance of very high concern, Rochelle salt was utilized as a buffer solution instead. The novelty of this study was to implement a...
-
Effect of the Cooling Time in Annealing at 350°C on the Phase Transformation Temperatures of a Ni<sub>5</sub><sub>5</sub>Ti<sub>4</sub><sub>5</sub> wt. Alloy
Publication -
ZASTOSOWANIE STATYSTYKI F ROZKŁADU FISHERA-SNEDECORA DO OCENY ISTOTNOŚCI WPŁYWU ZMIAN STOPNIA KOMPRESJI SILNIKA O ZS NA ŚREDNIĄ WARTOŚĆ MIĘDZYSZCZYTOWĄ TEMPERATURY SPALIN WYLOTOWYCH
PublicationW artykule omówiono wpływ zmian stopnia kompresji na parametry pracy silnika o ZS, m.in. na temperaturę spalin wylotowych. Przedstawiono budowę stanowiska laboratoryjnego, na którym przeprowadzono badania eksperymentalne. Scharakteryzowano, w jaki sposób w istniejącym silniku wprowadzano faktyczne zmiany stopnia kompresji. Zaprezentowano program badań eksperymentalnych uwzględniający dostępne stanowisko badawcze i jego możliwości...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Experimental verification of multiband system of non coantact temperature measurements. IV Workshop on Atomic and Molecular Physics.
PublicationW pracy przedstawiono wielopasmowy optoelektroniczny system do bezkontaktowych pomiarów temperatury wykonane za jego pomocą w zakresie od 250 do 390 stopni Celsjusza. Przeprowadzono dyskusję błędów pomiarowych i porównano otrzymane rezultaty z wynikami modelowania komputerowego.
-
High-Temperature Tensile Behaviour of GTAW Joints of P92 Steel and Alloy 617 for Two Different Fillers
PublicationThis study explores the high-temperature (HT) tensile rupture characteristics of a dissimilar gas-tungsten-arc-welded (GTAW) joint between P92 steel and Alloy 617, fabricated using ER62SB9 and ERNiCrCoMo-1 fillers. The high-temperature tensile tests were performed at elevated temperatures of 550 ◦C and 650 ◦C. An optical microscope (OM) and a field emission scanning electron microscope (FESEM) were utilized to characterize the...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
DETERMINING THE TIME CONSTANT USING TWO METHODS AND DEFINING THE THERMOCOUPLE RESPONSE TO SINE EXCITATION OF GAS TEMPERATURE
PublicationThis paper describes the two methods of determining the time constant of type K thermocouple, for two construction solutions: the exposed weld and the mantle fillet weld. This is an important parameter indicating the response time of the thermocouple on the recorded signal. The first method consists of determining the value of τ in the way of numerical simulation of heat exchange between the thermocouple and the current of gas...
-
Automatic Adjustment of Integration Time in the NIR Camera for Calibrated Temperature Measurement during Inductive Heating Processes
Publication -
New devices to capture the temperature effect under dynamic compression and impact perforation of polymers, application to PMMA
Publication -
The Impact of Experimental Temperature and Water Level Manipulation on Carbon Dioxide Release in a Poor Fen in Northern Poland
Publication -
Mechanical response of 6061-T6 aluminium alloy subjected to dynamic testing at low temperature: Experiment and modelling
Publication -
Low temperature growth of carbon nanotubes from methane catalytic decomposition over nickel supported on a zeolite
Publication -
Experiments and Numerical Simulations of the Annealing Temperature Influence on the Residual Stresses Level in S700MC Steel Welded Elements
Publication -
Application possibilities of the low-temperature repairs on creep-resistance turbine components from material GX23CrMoV12-1
Publication -
Temperature-Based Prediction of Joint Hardness in TIG Welding of Inconel 600, 625 and 718 Nickel Superalloys
Publication -
Effect of high temperature exposure on the fatigue damage development of X10CrMoVNb9-1 steel for power plant pipes
Publication -
Effect of plasma nitriding process on the fatigue and high temperature corrosion resistance of Inconel 740H nickel alloy
Publication -
A Novel Method for High Temperature Fatigue Testing of Nickel Superalloy Turbine Blades with Additional NDT Diagnostics
Publication -
MITOGEN-ACTIVATED PROTEIN KINASE 4 impacts leaf development, temperature, and stomatal movement in hybrid aspen
Publication -
Characterizing surface and air temperature in the Baltic Sea coastal area using remote sensing techniques and GIS
PublicationEstimation of surface temperature using multispectral imagery retrieved from satellite sensors constitutes several problems in terms of accuracy, accessibility, quality and evaluation. In order to obtain accurate results, currently utilized methods rely on removing atmospheric fluctuations in separate spectral windows, applying atmospheric corrections or utilizing additional information related to atmosphere or surface characteristics...
-
The influence of moderate pressure and subzero temperature on the shelf life of minced cod, salmon, pork and beef meat
PublicationThe effect of moderate pressure at subzero temperature on natural microflora of minced cod, salmony, pork and beef meat was studied. Pressure of 193 MPa at –20 °C caused reduction of total bacterial count in pork and beef meat by 1.1 and 0.6 log cycles, respectively, and by about 1.5 log cycles in fish meat. Under these conditions the psychrophilic and psychrotophic bacteria were below the detection limit (<10CFU/g of sample) in...
-
NICKEL-BASED LAYERED PEROVSKITE CATHODE MATERIALS FOR APPLICATION IN INTERMEDIATE-TEMPERATURE SOLID OXIDE FUEL CELLS
Publication -
<title>Correction of fiber optic ion sensor readings using a fiber optic temperature sensor</title>
Publication -
Effect of temperature and ionic strength on volumetric and acoustic properties of solutions of urea alkil derivatives in aqueous NaCl
PublicationThe present work was undertaken to study volumetric and acoustic properties for diluted solutions of tetramethylurea in pure water and for urea, n-propylurea, n-butylurea and tetramethylurea in 0.5 or 1 moldm3 aqueous solutions of sodium chloride. This paper presents measured values of densities and sound velocities at T = (288.15, 298.15 and 308.15) K. From these data the apparent molar volumes, , adiabatic compressibilities,...
-
On the tendency of temperature and electric field dependences of interface recombination in P3HT:PCBM organic bulk heterojunction solar cells
PublicationWe demonstrate theoretical explanation of the temperature and electric field dependences of recombination coefficients in an organic P3HT:PCBM bulk heterojunction solar cell. Based onthe model of interface recombination, two analytical formulas describing the relative ratio of the interface (γI ) to the Langevin (γL) recombination coefficients have been derived. Our analysis indicates that the sign of parameters φT and φF determines...
-
Influence of low-temperature physical hardening on stiffness and tensile strength of asphalt concrete and stone mastic asphalt
PublicationThis paper presents laboratory testing of stiffness modulus and indirect tensile strength of three asphalt concrete (AC) and three stone mastic asphalt (SMA) mixes after isothermal storage at temperature of -20oC, at different time intervals up to 16 days. The tests under repeated dynamic loading showed physical hardening of all tested mixes which was manifested by an evident increase of their stiffness moduli after isothermal...
-
Short-term changes in thickness and temperature of the active layer in summer in the Kaffiøyra region, NW Spitsbergen, Svalbard
Publication -
Improved Empirical Coefficients for Estimating Water Vapor Weighted Mean Temperature over Europe for GNSS Applications
PublicationDevelopment of the so-called global navigation satellite system (GNSS) meteorology is based on the possibility of determining a precipitable water vapor (PWV) from a GNSS zenith wet delay (ZWD). Conversion of ZWD to the PWV requires application of water vapor weighted mean temperature (Tm) measurements, which can be done using a surface temperature (Ts) and its linear dependency to the Tm. In this study we analyzed up to 24 years...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Analysis of the selection of low temperature medium for a turbine power plant using ocean thermal energy (OTEC)
PublicationThe paper presents the results and conclusions of numerical calculations modelled in the EES program of a closed OTEC cycle. The following mediums were analysed: ammonia, R32, R41, R404a, R407c, R410a, R423a, R500, R502, R507a and R114, R152a, R234fa, R600, R1234yf, R1234ze. Analogous assumptions were adopted as in the ORC cycle with heat regeneration for dry refrigerants without regeneration for wet refrigerants. Each of them...
-
Analysis of the selection of low-temperature medium for a turbine power plant using ocean thermal energy (OTEC)
PublicationThe paper presents the results and conclusions of numerical calculations modelled in the EES program of a closed OTEC cycle. The following mediums were analysed: ammonia, R32, R41, R404a, R407c, R410a, R423a, R500, R502, R507a and R114, R152a, R234fa, R600, R1234yf, R1234ze. Analogous assumptions were adopted as in the ORC cycle with heat regeneration for dry refrigerants without regeneration for wet refrigerants. Each of them...
-
Investigation of the 0.4C-35Cr-45Ni-Nb Alloy after Service in High-Temperature Steam and Hydrocarbons Environment
PublicationThe paper presents the results of investigation of the 0.4C-35Cr-45Ni-Nb alloy, which operated in the cracked hydrocarbon feeds and dilution steam at 1125 C. The material originated from the pyrolytic furnace coil tubes, of which internal walls were in contact with the aforementioned medium, whereas the external walls were in contact with the flue gases. The examination included metallographic and mechanical tests on the material...
-
Effects of La0.8Sr0.2MnO3 and Ag electrodes on bismuth-oxide-based low-temperature solid electrolyte oxygen generators
PublicationIn this study, La0.8Sr0.2MnO3 (LSM) was used as the ceramic electrode in a (Bi1.50Y0.50)0.98Zr0.04O3+δ (BYO)-based solid electrolyte oxygen generator (SEOG) and its performance was compared with that of a previously studied high-fire Ag electrode. Among La0.6Sr0.4Co0.2Fe0.8O3, LaNi0.6Fe0.4O3, Cu1.4Mn1.6O4, and LSM materials, only LSM materials did not trigger any chemical reaction or interdiffusion with BYO at temperatures up to...