Filters
total: 891
-
Catalog
Search results for: ELEKTRODY%20JONOSELEKTYWNE
-
Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate
PublicationThis work describes fabrication of gold electrodes modified with peptide conjugate DAL-PEG-DK5-PEG-OH that enables ultra-sensitive detection of lipopolysaccharide (LPS) isolated from the reference strain of Escherichia coli O26:B6. The initial step of the established procedure implies immobilization of the fully protected DAL-PEG-DK5-PEG-OH peptide on the surface of the gold electrode previously modified by cysteamine. Then side...
-
AFM investigation of electrode fabricated by 3D printing
Open Research Data3D printing, also known as additive manufacturing, has enjoyed great interest in recent years due to the versatility of this method of producing various shapes and details. Due to the possibility of precise control of the shape and composition of the printed elements, the discussed technique can be widely used in electrochemistry, including electrochemical...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Enhanced electrochemical performance of partially amorphous La0.6Sr0.4CoO3-δ oxygen electrode materials for low-temperature solid oxide cells operating at 400 °C
PublicationThis work evaluates partially amorphous La0.6Sr0.4CoO3-δ (LSC) as a potential oxygen electrode for lowtemperature solid oxide cells. LSC was deposited using the spin-coating technique onto Ce0.8Gd0.2O2-δ (CGO) substrates. The optimal oxygen electrode thickness was determined as 500 nm. The electrochemical impedance spectroscopy (EIS) study showed a significant improvement in oxygen reduction/oxidation reaction kinetics when annealing...
-
Impact of strontium non-stoichiometry of SrxTi0.3Fe0.7O3-δ on structural, electrical, and electrochemical properties for potential oxygen electrode of intermediate temperature solid oxide cells
PublicationThis work presents the results of a comprehensive study on the impact of the A-site non-stoichiometry of SrxTi0.3Fe0.7O3-δ (x = 0.90, 0.95, 1.00, 1.05) ceramics on their physicochemical properties. The materials were fabricated by the conventional solid-state reaction method and their structure was determined by X-ray diffractometry, X-ray photoelectron spectroscopy and electron microscopy. Their sintering and thermal expansion...
-
Electrochemical sensor for measurement of volatile organic compounds = Elektrochemiczny czujnik do oznaczania lotnych związków organicznych
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania benzaldehydu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako technikę detekcyjną woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym były ciecze jonowe: chlorek 1-heksylo,3- metyloimidazolinowy i bis(trifluorometylosulfonylo)imidek...
-
An EIT reconstruction algorithm based on noisy data.
PublicationPraca przedstawia algorytm rekonstrukcji oparty o zmodyfikowany algorytm Gaussa - Newtona. Algorytm uwzględnia istnienie elektrod pomiarowych w tomografii elektroimpedancyjnej. Elektrody charakteryzują się rozmiarem i impedancją. Dodatkowo algorytm zakłada istnienie szumu w sygnale mierzonym. Zostało pokazane, że dobór optymalnego wzorca pobudzenia znacząco poprawia odporność algorytmu rekonstrukcyjnego na szum w danych. Dwie...
-
Application of a cationic surfactant in the multichanel taste sensor
PublicationSubstancje należaće do czterech klas smaku były badane za pomocą pięciokanałowego sensora smaku składającego się z elektrod z membranami polimerowo-lipidowymi. Wykazanano, że elektroda zbudowana z membrany polimerowej zawierajacej kationowy surfaktant może byc z powodzeniem zastosoana w sensorze smaku do rozpoznania napojów składających sie głównie z sacharozy i kwasu cytrynowego produkowanych przez rózne firmy.
-
The electrochemical response to BDD electrode functionalization with CD147 receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with CD147 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with ACE2 receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with ACE2 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with IgG2B receptor
Open Research DataThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with IgG2B receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
Chemorezystancyjny czujnik gazu na bazie polimeru przewodzącego PEDOT
PublicationPolimery przewodzące, takie jak Poli(3,4-etylenodioksytiofen) (PEDOT) są atrakcyjnymi materiałami elektrodowymi, które posiadają takie zalety, jak biokompatybilność, duża przewodność i elastyczność. Elektroprzewodzące polimery można otrzymać w wyniku chemicznej polimeryzacji lub elektropolimeryzacji. W niniejszej pracy przedstawiono zostanie koncepcja czujnika gazów składająca się z elektrody grzebieniowej oraz polimeru przewodzącego...
-
Examination of the interactions occurring in the gas and liquid phases of atmospheric pressure glow discharge generated in contact with a liquid electrode leading to production of size-defined gold nanostructures
Publication -
Magnesium-Doped Sr2(Fe,Mo)O6−δ Double Perovskites with Excellent Redox Stability as Stable Electrode Materials for Symmetrical Solid Oxide Fuel Cells
Publication -
Tomasz Wąsowicz dr hab.
PeopleTomasz Wąsowicz's research was first related to high-resolution atomic spectroscopy and focused on measurements and analysis of the transition probabilities of the forbidden lines, the hyperfine and isotopic structure of spectral lines of heavy elements, Stark effect in the helium atom. Tomasz Wąsowicz currently studies physicochemical processes occurring during interactions of various forms of radiation with atoms and molecules...
-
Monika Wilamowska-Zawłocka dr hab. inż.
PeopleDr Monika WILAMOWSKA-ZAWŁOCKA obtained her PhD in Chemistry in 2011 at Faculty of Chemistry, Gdańsk University of Technology. She then was a post-doctoral fellow at Technische Universität Darmstadt, Germany. Since 2013 she has worked at Gdańsk University of Technology, since 2019 as an Associate Professor. Her research interests include composite materials for energy storage devices, especially for lithium-ion and sodium-ion batteries,...
-
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl) amides
PublicationPochodne dietyloamidowe p-tert-butylodihomooksakaliks[4]arenu (1), p-tert-butyloheksahomotrioksakaliks[3]arenu (2) oraz p-tert-butylokaliks[4]arenu (3) były wykorzystane jako materiał aktywny w membranach elektrod jonoselektywnych w celu sprawdzenia detekcji kationów różnych rodzajów (Na+, K+, Cs+, Mg2+, Ca2+, Mn2+, Cu2+, Zn2+, Cd2+, Pb2+ oraz kation tetrametyloammoniowy). Wyznaczono charakterystyki elektrod oraz współczynniki...
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublicationPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Simultaneous determination of droxidopa and carbidopa by carbon paste electrode functionalized with NiFe2O4 nanoparticle and 2-(4-ferrocenyl-[1,2,3]triazol-1-yl)-1-(naphthalen-2-yl) ethanone
Publication -
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
pH-tunable equilibria in azocrown ethers with histidine moieties
PublicationEtery koronowe posiadające elektro- i fotoaktywne reszty azowe oraz ugrupowania z ruchliwymi protonami jak w grupie COOH histydyny charakteryzują się unikalnym, zależnym od pH, efektem stymulowania pozornej obecności/nieobecności ugrupowania azowego. Obserwowane różnice właściwości elektrochemicznych eterów azokoronowych z resztą N-acetylohistydyny lub resztami imidazolu uwidaczniają się przebiegiem chemicznej redukcji w silnie...
-
Determination of moisture resistance of covered electrodes according to PN-EN ISO 14372
PublicationMoisture present in the electrode covering is one of the sources of diffusible hydrogen in welded joints. In order to study the diffusible hydrogen content in deposited metal, a stand for moisturizing covered electrodes, in accordance with the PN-EN ISO 14372 standard, was built. After the stand was completed, a test of moisturizing the electrodes was carried out and measurements of the diffusible hydrogen content in deposited...
-
SEM and Raman studies B:CNWs and BDD electrode used for electrochemical paraquat determination
Open Research DataThe dataset contains the scanning electron micrographs (SEM) and Raman spectra of B:CNWs and BDD samples deposited by MW-PECVD. SEM was used to characterise the morphology of BDD and B:CNW. In contrast, RAMAN was used to reveal the main differences in the crystalline structure of BDD and B:CNWs.
-
Laser microscope profilometry of SrTi0.3Fe0.7O3-d electrode surface after quickly drying
Open Research DataThe dataset consists of a surface image, topography and profilometry obtained using a Keyence VK-X1000 confocal laser microscope for SrTi0.3Fe0.7O3-d electrode (STF70). Imaging was performed to determine surface roughness. The Keyence VK-X1000 uses a 404 nm laser to map and measure the surface of samples via confocal scanning or a wide-field variable...
-
Laser microscope profilometry of SrTi0.3Fe0.7O3-d electrode surface after slowly drying
Open Research DataThe dataset consists of a surface image, topography and profilometry obtained using a Keyence VK-X1000 confocal laser microscope for SrTi0.3Fe0.7O3-d electrode (STF70). Imaging was performed to determine surface roughness. The Keyence VK-X1000 uses a 404 nm laser to map and measure the surface of samples via confocal scanning or a wide-field variable...
-
Organic electroluminescent devices containing phosphorescent molecules in molecularly doped hole transporting layer.
PublicationW pracy opisano mechanizm świecenia diody dwuwarstwowej diody elektroluminescencyjnej (EL) o zewnętrznej kwantowej wydajności świecenia osiągającej 9% fot./elektron. Warstwę transportującą elektrony tworzyła pochodna osadiazolu (PBD) otrzymana metodąnaparowania próżniowego. Warstwę transportującą dziury uzyskano przez wylanie roztworu poliwęglanu(PC), dendrymeru aminowego m-MTDATAoraz fosforyzującego kompleksu irydu Ir(ppy)3 i...
-
Corrosion monitoring of selected metals in artificial seawater by harmonic synthesis method
PublicationPrzedstawiono podstawy teoretyczne nowej metody elektrochemicznej nazwanej metodą syntezy harmonicznej (SH). Metoda jest oparta na pomiarach pierwszych trzech składowych harmonicznych prądu generowanego przez korodującą elektrodę po pobudzeniu sinusoidalnym sygnałem napięciowym bardzo niskiej częstotliwości. Na tej podstawie rekonstruowana jest dyskretna quasi-stacjonarna charakterystyka polaryzacyjna elektrody. Jej analiza numeryczna...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with EDS map analysis results. This study were performed for better understanding the chemical composition of flat like structures that occurs in electrode. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope...
-
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...
-
Caffeine detection using CB-PLA electrode after Nd:YAG laser ablation in He atmosphere
Open Research DataThe dataset contains electrochemical studies in form of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) of laser-activated 3D printed CB-PLA electrodes. The ablation of the 3D-printed CB-PLA electrodes was carried out using a pulsed LaserBlast 500 Nd:YAG laser (Quantel, France) operating at 1064 nm and a 6 ns pulse duration.
-
The cyclic voltammetry studies of CB-PLA electrode after surface activation by electrolysis in 1M NaOH
Open Research DataThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M NaOH solution. The studies were performed after treatment at an anodic overpotential of 1V, found to be optimal for surface activation. The measurements were carried out with cyclic voltammetry (CV) under different...
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
Przewodzące materialy ograniczne 2022/2023
e-Learning CoursesTresci wykladu: Wprowadzenie do elektrochemii ciała stałego. Elektrolity (E) stałe, Właściwości elektryczne jonowych przewodników prądu. Polimerowe elektrolity stałe. Elektrolity żelowe, hydrożele i elektrolity żelowe z rozpuszczalnikami aprotycznymi. Polielektrolity, jonomery, membrany jonoselektywne (nafion inne) Granica faz elektroda(przewodnik I rodzaju)-elektrolit, granica faz polprzewodnik/ elektrolit. Materiały elektrodowe...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Opracowanie potencjometrycznej wieloczujnikowej platformy wykonanej całkowicie w technologii All-Solid-State do jednoczesnego oznaczania kilku jonów w roztworach wodnych
PublicationW pracy przedstawiono charakterystykę i konstrukcje różnych elektrod jonoselektywnych (EJS), a także opisano elektrodę odniesienia i jej funkcję. Przybliżono możliwości zastosowania EJS do monitorowania śladowych ilości ołowiu (II) w otoczeniu kopalni rud cynku i ołowiu, oraz jako biowskaźnik stanu pacjenta w czasie wstrząsu septycznego. Opisano wieloczujnikowe platformy potencjometryczne (WPP) w technologii All-Solid-State (ASS). W...
-
Oxygen partial pressure and temperature dependence of Gerischer element of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of Gericher element at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C)and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent circuit...
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of series resistance (R) at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element series resistance at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
High resolution XPS analysis of BDD electrode functionalization steps towards SARS-CoV-2 detection
Open Research DataThis dataset contains the results of the high-resolution XPS analyses of a set of boron-doped diamond (BDD) electrodes after consecutive functionalization steps toward anchoring of a receptor capable of SARS-CoV-2 virus detection. The analysis was carried out in the binding energy range of C1s, N1s, O1s, Ni2p3/2. The measurements were carried out on...
-
Kontrola jakości i analityka techniczna [Moduł dyscyplinarny, grupa B]
e-Learning CoursesProwadzący: Dr hab. inż. Grzegorz Boczkaj prof. PG Terminy realizacji: 25 marca, 1 kwietnia, 15 kwietnia, 22 kwietnia, 13 maja w godz. od 09:15 do 12-tej /zajęcia online Tematyka realizowanego przedmiotu obejmuje: Pobieranie próbek do badań (on-line, off-line, at-line, in-line) Przygotowanie próbek do badań (techniki i przykłady metodyk dla próbek stałych, ciekłych i gazowych) Techniki i wybrane metodyki klasyczne (miareczkowanie,...
-
Metoda pomiarowa dla dwuczęstotliwościowej tomografii elektroimpedancyjnej.
PublicationW referacie przedstawiono technikę pomiaru prądu/napięcia sinusoidalnego zastosowaną w tomografie elektroimpedancyjnym (TEI). Prezentowany TEI, którego konstrukcja bazuje na układzie tzw. elektrody aktywnej, zaliczany jest do grupy systemów równoległo-szeregowych. Układ elektrody aktywnej umieszczony jest bezpośrednio przy elektrodzie. Identyfikacja parametrów mierzonego sygnału przemiennego następuje w układzie elektrody...
-
Krzysztof Karwowski dr hab. inż.
People -
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
Oxygen partial pressure and temperature dependence of low frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of low frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...