displaying 1000 best results Help
Search results for: FAULT LOOP IMPEDANCE
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublicationThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publication -
Fault diagnosis in electronic circuits based on bilinear transformation in 3-D and 4-D spaces
PublicationPrzedstawiono ideę nowych metod diagnostycznych 3-D i 4-D opartych na przek-ształceniu biliniowym. Metody te bazują na transformacjach operujących odpo-wiednio w trzy i czterowymiarowych przestrzeniach funkcji układowych. Dlatych metod omówiono algorytm lokalizacji i identyfikacji pojedynczych uszko-dzeń parametrycznych w liniowych układach elektronicznych oraz algorytm lo-kalizacji i identyfikacji pojedynczych uszkodzeń...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublicationWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Linear impedance of 25Na2O–20CaO–5P2O5–50SiO2 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 25Na2O–20CaO–5P2O5–50SiO2 glass was measured by impedance spectroscopy method.
-
Impedance spectra of ZnO varistor type 440 model A ver. M
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model A ver. M
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
Publication -
Preparation of Komagataeibacter xylinus Inoculum for Bacterial Cellulose Biosynthesis Using Magnetically Assisted External-Loop Airlift Bioreactor
Publication -
Deep analysis of Loop L1 HVRs1-4 region of the hexon gene of adenovirus field strains isolated in Poland
Publication -
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Linear impedance of V2O5 nanorods obtained at 903K
Open Research DataThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Linear impedance of V2O5 nanorods obtained at 913K
Open Research DataThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Linear impedance of V2O5 nanorods obtained at 893K
Open Research DataThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Linear impedance of 0.5Si3N4–99.5(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 0.5Si3N4–99.5(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.
-
Linear impedance of 1Si3N4–99(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 1Si3N4–99(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 30Bi2VO5.5-70SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 30Bi2VO5.5-70SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of vanadate glasses containing BaTiO3
Open Research DataThe linear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Linear impedance of V2O5 nanorods obtained at 923K
Open Research DataThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Linear impedance of 2Si3N4–98(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 2Si3N4–98(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublicationThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
Impedance spectra of ZnO varistor type 680 model A M ver. 93
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. xx
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Identification and localization of organic coating degradation onset by impedance imaging
Publication -
Electrochemical impedance studies of AB5 -type hydrogen storage alloy
PublicationDo wyznaczenia własności stopu AB5 wykorzystano elektrochemiczną spektroskopie impedancyjną. Badania impedancyjne wykonano podczas chronowoltamperometri cyklicznej oraz cykli ładowania i rozładowania elektrody. Interpretacja uzyskanych w trybie potencjostatycznym wyników pozwoliła na dalszą interpretacje wyników uzyskanych w trybie galwanostatycznym. Proponowana metodologia umożliwia śledzić parametry elektryczne badanego układu...
-
Instantaneous impedance spectra of a non-stationary model electrical system
Publication -
Optimization of impedance measurements using ‘chirp’ type perturbation signal
Publication -
The application of impedance measurements for the determination of the probability of the course of corrosion processes
Publication -
Corrosion rate measurements by non-linear electrochemical impedance spectroscopy
Publication -
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publication -
Electrochemical impedance studies of AB5-type hydrogen storage alloy
Publication -
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy
Publication -
Dual-Frequency Induction Heating Generator With Adjustable Impedance Matching
Publication -
Application of different modes of nanoscale impedance microscopy in materials research
Publication -
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublicationSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
PublicationW niniejszej pracy przeprowadzono badania elektrochemiczne powierzchniowego efektu PLC, związanego z nierównomiernym procesem płynięcia plastycznego stopów aluminium zawierających magnez. Występujący efekt PLC w postaci serration wywołuje niehomogeniczny proces zmian zewnętrznej powierzchni rozciąganej próbki. Wykonano badania metodą Dynamicznej Spektroskopii Impedancyjnej w warunkach dynamicznych prowadzenia procesu rozciągania....
-
Optimization of impedance measurements using ''chirp'' type perturbation signal
PublicationW pracy przedstawiono innowacyjny sposób pomiaru impedancji przy użyciu sygnału niestacjonarnego "chirp". W procesie akwizycji pobudzenia i odpowiedzi prądowej zastosowano zmienną częstotliwość próbkowania. Podejście takie pozwala zarówno na wielokrotne zmniejszenie ilości niezbędnych do otrzymania widma impedancyjnego rejestrowanych danych jak również upraszcza i przyspiesza proces obliczeniowy. Stwierdzono iż dokładność wyników...