displaying 1000 best results Help
Search results for: MULTISNUSIODAL IMPEDANCE SPECTROSCOPY
-
Mössbauer Spectroscopy and Magnetoelectric Effect Studies of Multiferroic Ceramics Based on BiFeO<sub>3</sub>
PublicationIn this work the results of investigations for (BiFeO3)x(BaTiO3)1-x and Bi1-xNdxFeO3 solid solutions are described. Samples were prepared by the conventional solid-state sintering method. X-ray diffraction, 57Fe Mössbauer spectroscopy, and magnetoelectric effect measurements were applied as complementary methods to determine the structure and magnetic properties of materials. For (BiFeO3)x(BaTiO3)1-x solid solutions Mössbauer...
-
Measurement system for nonlinear surface spectroscopy by atomic force microscopy for corrosion processes monitoring
PublicationIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is especially useful for heterogeneous...
-
Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters With Reduced Switch Count
Publicationhis paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along with simulation and experimental verification are also provided. Possible application fields are discussed, as well as advantages and disadvantages....
-
Efficient Gradient-Based Algorithm with Numerical Derivatives for Expedited Optimization of Multi-Parameter Miniaturized Impedance Matching Transformers
PublicationFull-wave electromagnetic (EM) simulation tools have become ubiquitous in the design of microwave components. In some cases, e.g., miniaturized microstrip components, EM analysis is mandatory due to considera¬ble cross-coupling effects that cannot be accounted for otherwise (e.g., by means of equivalent circuits). These effects are particularly pronounced in the structures in¬volving slow-wave compact cells and their numerical...
-
Electrochemical cell impedance spectra at Eoc+100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublicationPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Weak hydrogen bonding interaction S-H···O=C studied by FT-IR spectroscopy and DFT calculations
PublicationInteractions between the thiolate group of tri-tert-butoxysilanethiol (TBST) and carbonyl group of acetone are studied with the use of FT-IR spectroscopy and DFT calculations.
-
On the characteristic impedance definition in microstrip and coplanar lines
PublicationW niniejszej pracy rozważono definicję impedancji charakterystycznej dla bezstratnych linii mikropaskowych i koplanarnych. Wykazano, że ze względu na znaczne wartości prądu przesunięcia związanego z podłużną składową pola elektrycznego, definicja impedancji staje się niejednoznaczna. W rezultacie może to przyczyniać się do istotnych błędów powstających już na etapie projektowania układów. Pokazano, iż efekt ten jest szczególnie...
-
Mesoscopic impedance analysis of solid materials’ surface
Publication -
The time dependence of pit creation impedance spectra
Publication -
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Continuous frequency method of measurement of electrode impedance.
PublicationPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Impedance measurements of coating properties on bridge structures
PublicationPomiary impedancyjne pozwalają na prostą ocenę właściwości ochronnych powłok ochronnych i wykładzin. Pomiary stosuje się w celu porównania powłok, monitorowania ich właściwości i oceny mechanizmu działania. Metodyka jest z powodzeniem stosowana w pomiarach laboratoryjnych. Pomiary terenowe są bardziej skomplikowane ponieważ wymagają w pełni kontrolowanych komputerowo przyrządów, kontroli warunków pogodowych oraz wielu innych parametrów...
-
A metrological analysis of the input circuit of an impedance meter.
PublicationW pracy przeprowadzono analizę obwodu wejściowego miernika impedancji W analizie obwodu wejściowego, uwzględniono najważniejsze czynniki wpływające na sygnały na jego wejściu: parametry zmiennoprądowe zastosowanych wzmacniaczy, rezystancję zakresową przetwornika prąd-napięcie, pojemności montażowe. Przeprowadzono symulację sygnałów wydzielanych w obwodzie dla różnych wartości pojemności pasożytniczych, następnie dokonano badań...
-
The time dependence of pit creation impedance spectra.
PublicationPrzeprowadzono pomiar impedancyjny w warunkach chronoamperometrycznych uzyskując zmiany impedancji układu w czasie. Na ich podstawie wyznaczono zmiany rezystancji przeniesienia ładunku i pojemności w czasie opisujące inicjację i rozwój korozji wżerowej. Potwierdzono użyteczność dynamicznej elektrochemicznej spektroskopii impedancyjnej w badaniu korozji wżerowej.
-
Change of myocardial impedance during experimental ischemia.
PublicationW pracy omówiono możliwość monitorowania procesu niedotlenienia za pomocą pomiarów immitancyjnych. Przedstawiono skonstruowane stanowisko pomiarowe ze szczególnym uwypukleniem właściwości sondy pomiarowej. Przedstawiono wyniki eksperymentalnego niedotlenienia u świń wywołanego zamknięciem LAD.
-
Advances in electrical impedance methods in medical diagnostics
PublicationOmówiono elektroimpedancyjne metody diagnostyczne i aparaturę pomiarową opracowane w Politechnikach - Gdańskiej i Warszawskiej.Przedyskutowano właściwości elektryczne różnych tkanek biologicznych, omówiono konstrukcję celek i elektrod do pomiarów in vivo oraz in vitro. Opisano konstrukcję wybranych systemów pomiarowych - pletyzmografów, kardiografów i tomografów elektroimpedancyjnych a także stosownego oprogramowania, np. rekonstrukcji...
-
Mesoscopic impedance analysis of solid materials surface
PublicationSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
X-Ray Diffraction, Mössbauer Spectroscopy and Magnetoelectric Effect Studies of Multiferroic Bi5Ti3FeO15 Ceramics
PublicationBi5Ti3FeO15 ceramics belongs to multiferroic class of materials. In this work it was prepared by solid-state sintering method and investigated by X-ray diffraction, Mössbauer spectroscopy, and magnetoelectric effect measurements. As it was proved by X-ray diffraction studies the single-phase Bi5Ti3FeO15 compound was obtained. The Mössbauer investigations revealed paramagnetic character of the compound at room temperature as well...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Simultaneous measurements of ECG, body Impedance and temperature
Open Research DataThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
Synthesis, spectroscopy and computational studies of some biologically important hydroxyhaloquinolines and their novel derivatives
PublicationA series crystalline compounds of methyl and phosphinyl derivatives of 2-methylquinolin-8-ol (1a) and related 5,7-dichloro-2-methylquinolin-8-ol (1b) were quantitatively prepared and characterized by microanalysis, IR, UV-vis and multinuclear NMR spectroscopy. Five of them have been characterized by single crystal X-ray diffraction method. The known compounds, 8-methoxy-2-methylquinoline (2a) and 8-methoxyquinoline (2d), were synthesised...
-
Synthesis, spectroscopy and computational studies of some novelphosphorylated derivatives of quinoline-5,8-diones
PublicationThe neutral phosphorus nucleophiles such as R2P(=Y)M allowed the radical addition to 2-methyl-5,8-dioxo-5,8-dihydroquinoline-7-amine and N-(2-methyl-5,8-dioxo-5,8-dihydroquinolin-7-yl)acetamide giving exclusively O-phosphorylated products. All products were quantitatively prepared and characterized by microanalysis, and multinuclear NMR spectroscopy. Seven of them, have been characterized by single crystal X-ray diffraction method....
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublicationIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Optical spectroscopy and scintillation mechanisms ofCexLa1−xF3
Publication -
High pressure spectroscopy of chromium doped LiTaO3crystals
Publication -
Fluorescent spectroscopy of collagen as a diagnostic tool in medicine
Publication -
Hydration of tetrahydrofuran derived from FTIR spectroscopy
PublicationZbadano hydratację THF na podstawie spektroskopii FTIR drgań HDO oraz H2O. Dane widmowe poddano analizie przy pomocy ilościowej metody widm różnicowych. Ustalono, że w roztworach rozcieńczonych hydratacja THF typu hydrofobowego dominuje nad hydratacją typu elektrofilowego. Scharakteryzowano wodę w otoczce hydratacyjnej THF poprzez jej porównanie z wodą czystą.
-
Noise sources in Raman spectroscopy of biological objects
PublicationWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy
PublicationIn this work, the mechanism of the NO2 reaction with PEDOT-RGO composite film has been investigated via in situ Raman spectroscopy. Reduced graphene oxide (RGO), poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO) and poly(3,4-ethylenedioxytiophene)/ClO4− (PEDOT/ClO4−) films were fabricated using an electrodeposition method and used as resistance sensors of gaseous nitrogen dioxide. The experimental results indicate...
-
Study of the Layer-Type BST Thin Film with X-ray Diffraction and X-ray Photoelectron Spectroscopy
PublicationIn the present paper, results of X-ray photoelectron studies of electroceramic thin films of barium strontium titanate, Ba1xSrxTiO3 (BST), composition deposited on stainless-steel substrates are presented. The thin films were prepared by the sol-gel method. A spin-coating deposition of BST layers with different chemical compositions was utilized so the layer-type structure of (0-2) connectivity was formed. After the deposition,...
-
Drop-coating deposition surface-enhanced Raman spectroscopy on silver substrates for biofluid analysis
PublicationUtilization of surface-enhanced Raman spectroscopy as a measurement technique is of particular interest in biodetection due to its superb chemical specificity and high sensitivity. The use of SERS substrates further improve this method by massive enhancement of the molecule Raman spectrum, permitting very low levels of detection. Therefore it is important to seek for new ways to develop reliable substrates, which are quickly and...
-
Higher harmonics of the intensity modulated Photocurrent/Photovoltage spectroscopy response - a tool for studying photoelectrochemical nonlinearities
PublicationIn this work, a higher harmonic analysis (HHA) of the intensity modulated photocurrent/photovoltage (IMPS/IMVS) spectroscopy data is proposed as a potent tool for studying nonlinear phenomena in photoelectrochemical and photovoltaic systems. Analytical solutions of kinetic equations were constructed for cases of single and double resonance accounting for various sources of higher harmonics. These sources correspond to the physical...
-
Surrogate modeling of impedance matching transformers by means of variable‐fidelity electromagnetic simulations and nested cokriging
PublicationAccurate performance evaluation of microwave components can be carried out using full‐wave electromagnetic (EM) simulation tools, routinely employed for circuit verification but also in the design process itself. Unfortunately, the computational cost of EM‐driven design may be high. This is especially pertinent to tasks entailing considerable number of simulations (eg, parametric optimization, statistical analysis). A possible...
-
Determination of API content in a pilot-scale blending by near-infrared spectroscopy as a first step method to process line implementation
PublicationNear infrared (NIR) spectroscopy was used for estimation of powder blend homogeneity and manufacturing control of a medicinal product powder mixture containing active pharmaceutical ingredient (API). Aiming at initiating a Process Analytical Technology (PAT) activity, the first step was a stationary mode atline evaluation. In this, the content of pharmaceutical active compound in the powder mixtures intended to the direct tabletting...
-
Selective adsorption of BTEX on calixarene-based molecular coordination network determined by 13C NMR spectroscopy
PublicationBenzene, toluene, ethylbenzene, and xylenes (BTEX), a class of volatile organic compounds, are harmful pollutants but also very important precursors in organic industrial chemistry. Among different approaches used for the BTEX treatment, the adsorption technology has been recognized as an efficient approach because it allows to recover and reuse both adsorbent and adsorbate. However, the selective adsorption of the components is...
-
Multi-objective optimization of compact UWB impedance matching transformers using Pareto front exploration and adjoint sensitivities
PublicationIn this paper, a technique for fast multi-objective optimization of impedance matching transformers has been presented. In our approach, a set of alternative designs that represent the best possible trade-offs between conflicting objectives (here, the maximum reflection level within a frequency band of interest and the circuit size) is identified by directly exploring the Pareto front. More specifically, the subsequent Pareto-optimal...
-
On-line Impedance Monitoring of Direct Methanol Fuel Cell
PublicationW niniejszej pracy została przedstawiona technika badawcza Dynamiczna Elektrochemiczna Spektroskopia Impedancyjna w obszarze badań ogniw paliwowych. Obiektem badań było ogniwo paliwowe zasilane bezpośrednio metanolem. Badano on-line wpływ zmian warunków pracy na globalną impedancję ogniwa. Podczas pomiarów zmianie ulegała temperatura, natężenia przepływu utleniacza oraz obciążenie.
-
New concept of a measurement probe for high impedance spectrocopy
PublicationArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
Fast impedance measurement method using Laplace transformation
PublicationArtykuł przedstawia metodę pomiaru impedancji wykorzystującą rzeczywisty uskok jednostkowy step jako sygnał pobudzenia i transformację Laplace jako narzędzie analizy sygnału odpowiedzi testowanego obiektu. Metoda jest dedykowana do badania różnych obiektów technicznych (np. powłok antykorozyjnych, czujników gazu, ceramik, tkanek biologicznych itp.) gdy czas pomiaru nie może być długi. Przedstawiona metoda jest znana ale niezbyt...
-
Fundamental-harmonic impedance of first-order electrode reactions
Publication -
Determination of electrode impedance by means of exponential chirp signal
Publication -
Impedance Investigations of the Mechanism of Oxygen Evolution on Composite Electrodes
Publication -
Theoretical description of the measuring method of instantaneous impedance spectra
Publication -
Impedance matching in dual-frequency induction heating systems
Publication -
Determination of electrode impedance by means of exponential chirp signal.
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Jako pobudzenie zastosowany został niestacjonarny sygnał napięciowy, którego częstotliwość jest ekspotencjalną funkcją czasu. Zastosowanie zmodyfikowanej któtko-czasowej transformaty Fouriera (STFT) w analizie napięciowego pobudzenia i odpowiedzi prądowej pozwala na otrzymanie widma impedancyjnego.