Search results for: CON TROL AND PROTECTION SYSTEMS
-
Hybrid constructed wetlands for the National Parks in Poland - a case study, requirements, dimensioning, preliminary results
PublicationWater and wastewater management, especially in rural areas, greatly affects loads of nutrients discharged to the Baltic Sea. In Poland, this management is unbalanced because of the dispersed development and in many locations con struction of sewerage system is uneconomic or even impossible. For this reason, a significant part of sewage from single-family houses in rural areas must be discharged into domestic sewage systems. The...
-
Thermal efficiency investigations on the self-ignition test engine fed with marine low sulfur diesel fuels
PublicationWithin the article an issues of implementing the new kinds of marine diesel fuels into ships’ operation was described taking into ac-count restrictions on the permissible sulphur content introduced by the International Maritime Organization. This is a new situation for ship owners and fuel producers, which forces the necessity to carry out laboratory research tests on especially adapted engine stands. How to elaborate the method...
-
PROBLEMS WITH CORROSION PROTECTION STEEL STACKS IN FGD SYSTEMS
PublicationThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at a stack which discharges flue gas before wet lime/limestone desulphurization. A very rapid soaking of spherical infill vinylester coating with electrolyte has been observed....
-
Strength analysis of the support structure of the offshore wind turbine
PublicationThe global power demand from renewable sources is growing. One of a very favorable solution which meets severe environmental protection requirements are the offshore wind turbines. The offshore wind energy sector has experienced very fast development over last decade. Offshore wind farms, in comparison with onshore applications, can provide increased efficiency with reduced noise, visual, transportation and installation con-flicts....
-
Selection of Organic Coating Systems for Corrosion Protection of Industrial Equipment
PublicationThe most important element of corrosion protection in industrial conditions is the protective coating system. However, selecting the right coating can often be a real problem due to the sheer number of coating manufacturers and their products on the market. A quantitative approach based on the data mining technique used to analyze the obtained multi-site exposure data has been proposed. This was demonstrated by the example of the...
-
Evaluation of organic coating systems for corrosion protection of industrial equipment using impedance spectroscopy
PublicationThe high economic impact of corrosion can be reduced by enhanced corrosion management and prevention based on appropriate means. This applies in particular to the protection of structures with organic protective coatings. Steel is subject to corrosion that reduces its service life and leads to destruction in most severe cases. The application of paints to metallic objects for corrosion control has been known for a long time and...
-
1+1 Protection of Overlay Distributed Computing Systems: Modeling and Optimization
PublicationW niniejszym artykule przedstawiono autorską koncepcję ochrony transmisji od krańca do krańca (ang. 1+1 protection) dla systemów przetwarzania rozproszonego (ang. distributed computing systems). Artykuł prezentuje nowatorskie rozwiązanie dedykowane systemom typu ''overlay'', w których system przetwarzania rozproszonego stanowi warstwę najwyższą w warstwowej architekturze sieci, korzystającą z usług warstwy sieci transportowej....
-
Functional safety with cybersecurity for the control and protection systems on example of the oil port infrastructure
PublicationSafety and cybersecurity aspects consist of two different group of functional requirements for the industrial control and protection systems in the oil port installation. It is the main reason why the analyses of safety and cybersecurity shouldn’t be integrated directly. These article presented some important issues of the functional safety analysis with regard to cybersecurity aspects in the oil seaport infrastructure. The proposed...
-
EIS in diagnostic of cathodic protection systems
PublicationZaprezentowano wyniki badań wykonywanych techniką elektrochemicznej spektro-skopiiimpedancyjnej (EIS) na elementach instalacji ochrony katodowej podziemnego rurociągu stalowego. Przedstawiono widma impedancyjne następujących układów: elektroda odniesienia/elektrody pomocnicze; rurociąg/zakopane i przenośne elektrody odniesienia. Wykazano, że przy pomocy prezentowanej techniki można zbadać stan techniczny elektrod odniesienia, co...
-
Multiple solutions of indefinite elliptic systems via a Galerkin-type Con- ley index theory
PublicationW pracy wykazano prawdziwość hipotezy Angenenta i van der Vorsta dotyczącąilości rozwiązań pewnego układu eliptycznego. Liczbę rozwiazań szacuje się zdołu przy pomocy niezmiennika topologicznego zwanego uogólnionym indeksemMorse`a. W dowodzie stosuje sie niezmienniczy index Conleya w przestrzeniachHilberta.
-
Rafał Leszczyna dr hab. inż.
PeopleDr hab. Rafal Leszczyna is an associate professor at Gdansk University of Technology, Faculty of Management and Economics. He holds the M.Sc. degrees of Computer Science and Business Management. In December, 2006 he earned a Ph.D. in Computer Science, specialisation - Computer Security at the Faculty of Electronics, Telecommunications and Informatics of Gdansk University of Technology. Between 2004 and 2008 he worked in the European...
-
An integrated analysis of protection layers in hazardous systems
PublicationGłównym tematem niniejszej publikacji jest dyskusja nad wybranymi zagadnieniami związanymi z analizą bezpieczeństwa funkcjonalnego infrastruktury krytycznej oraz obiektów podwyższonego ryzyka. Problematyka bezpieczeństwa funkcjonalnego związana jest z międzynarodowymi normami IEC 61508 oraz IEC 61511. W artykule przedstawiono problematykę zintegrowanej oceny bezpieczeństwa funkcjonalnego wraz z uwzględnieniem analizy warstw zabezpieczeń...
-
Optimization of Stabilizing Systems in Protection of Cultural Heritage: The Case of the Historical Retaining Wall in the Wisłoujście Fortress
PublicationThe aim of the paper is to propose new quantitative criteria for selecting the optimal method of securing and repairing a historical object, which take into account Structural, Conservation and Architectural aspects (the S–C–A method). Construction works on cultural heritage sites tend to be challenging and require an interdisciplinary approach. Therefore, they are strictly related to the philosophy of sustainable development which...
-
Functional safety and security assessment of the control and protection systems
PublicationW artykule zostały poruszone kluczowe aspekty integracji podejścia bezpieczeństwa funkcjonalnego ''safety'' i ochrony informacji ''security'' w rozproszonych systemach sterowania i zabezpieczeniowych. Próba integracji zagadnień ''safety'' @ ''security'' została zilustrowana na przykładzie systemu monitoringu i zabezpieczeń pracującego w obiekcie podwyższonego ryzyka.
-
Evaluation and characterisation of the condition of individual components of cathodic protection systems
Publication -
Methods for verification safety integrity level in control and protection systems
PublicationW artukule przedstawiono podstawowe oraz zaawansowane ilościowe metody weryfikacji poziomów nienaruszalności bezpieczeństwa SIL w systemach sterowania i zabezpieczeń. Metody te zawierają analizę wrażliwości i niepewności modeli probabilistycznych tych systemów. Pod uwagę wzięte zostały także uszkodzenia o wspólnej przyczynie. Zaprezentowane zostały wyniki analiz oraz zalety ich stosowania.
-
Protection of surface water against contamination by wetland systems in Poland
PublicationOpisano systemy hydrofitowe stosowane do usuwania zanieczyszczeń z wód powierzchniowych zasilanych wodami opadowymi. Po wprowadzeniu systemów stwierdzono znaczną poprawę jakości wód analizowanych cieków.
-
Evaluation and characterisation of the condition of individual components of cathodic protection systems.
PublicationPrzedstawiono wyniki badań wykonanych na pracującej instalacji ochrony katodowej dwóch podziemnych zbiorników LPG. Sprawność anod i zakopanych elektrod odniesienia oceniono wykorzystując technikę elektrochemicznych pomiarów impedancyjnych. Na podstawie uzyskanych widm impedancyjnych stwierdzono niesprawność jednej z anod przyłączonych do długiej linii anodowej. Przedstawiono także mapę rozkładu potencjału chronionych zbiorników....
-
Designing control and protection systems with regard to functional safety aspects.
PublicationZaproponowano zintegrowane podejście w ocenie bezpieczeństwa funkcjonalnego systemów E/E/PE. Niepewność probabilistycznych miar ryzyka dla elektrycznych, elektronicznych i programowalnych elektronicznych systemów jest reprezentowana za pomocą przedziałów, które są porównywane z przedziałowymi kryteriami probabilistycznymi zdefiniowanymi dla tych systemów przez normę IEC 61508, w postaci czterech poziomów nienaruszalności bezpieczeństwa...
-
Architectural and Urban Planning Solutions for the Protection of Heritage Buildings in the Context of Terrorist Attacks: Following the Example of Passive Protection Systems
PublicationEvents in recent years showing numerous terrorist attacks raise awareness regarding the neces-sity of considering the safety of heritage buildings. The analysis of available data allows us to conclude that it is not possible to fully prevent terrorist attacks. On the other hand, it is possible to minimize the impact of such incidents through proper design of Passive Protection System (PPS) components. One possible architectural...
-
Directions Of Applications Of Optical Fiber Technology In Medicine And Health Protection Systems
Publication -
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Protection and Control of Modern Power Systems
Journals -
Determining and verifying the safety integrity level of the controland protection systems under uncertainty
PublicationThe probabilistic models of the electrical, electronic and programmable electronic (E/E/PE)systems, which are proposed in the IEC 61508 and IEC 61511 standards, do not cover the uncertainty aspectsof results obtained from these models. The proposed method takes into consideration the sensitivity analysisof probabilistic models of E/E/PE systems as well as the uncertainty of probabilistic results. It uses differentialfactors, which...
-
Security aspects in verification of the safety integrity level of distributed control and protection systems
PublicationPrzedstawiono najważniejsze zagadnienia zwišzane z weryfikacjš poziomu nienaruszalnoci bezpieczeństwa SIL rozproszonych systemów sterowania i zabezpieczeń z uwzględnieniem aspektów ochrony informacji. Przedstawiono ilociowš metodę weryfikacji poziomu SIL z wykorzystaniem wskaników różnicowych oraz dwuparametrowš funkcję kryterialnš łaczšcš wymagania SIL oraz EAL (poziom uzasadnionego zaufania dla ochrony informacji).
-
Designing Control and Protection Systems with Regard to Integrated Functional Safety and Cybersecurity Aspects
PublicationThis article addresses current problems of risk analysis and probabilistic modelling for functional safety management in the life cycle of safety-related systems. Two main stages in the lifecycle of these systems are distinguished, namely the design and operation. The risk analysis and probabilistic modelling differ in these stages in view of available knowledge and data. Due to the complexity and uncertainty involved, both qualitative...
-
Using impedance spectroscopy to characterize and monitor protection aspects of organic coating systems on metal
PublicationOrganiczne powłoki ochronne stosowane są powszechnie do ochrony konstrukcji metalowych przed korozją i zużyciem mechanicznym. W pracy zaproponowano nowy typ sensora impedancyjnego, który może być zastosowany do ciągłej oceny właściwości barierowych i adhezyjnych systemów powłokowych w warunkach terenowych w sposób nieniszczący, bez konieczności stosowania naczyń z elektrolitem. Przedstawiono koncepcję czujnika oraz przykładowe...
-
Modern design solutions of cooling systems, as an example of energy efficiency rationing, operational safety and environmental protection
Publication -
Protection of visual data transmission for vessel traffic systems using joint fingerprinting and decryption method based on modified hill cipher
Publication -
Computerized control and protection systems in technical objects and installations = Komputerowe systemy sterowania i zabezpieczeń w obiektach oraz instalacjach technicznych
PublicationArtykuł przedstawia zagadnienia dotyczące systemów komputerowych sterowania i układów automatyki bezpieczeństwa. Rozwój automatyki i informatyki na przestrzeni ostatnich lat wymusił wprowadzenie szeregu nowych rozwiązań technicznych, dotyczących procesów sterowania i kontroli instalacji technicznych. Dąży się do automatyzacji kompleksowej instalacji technicznych, rozumianej, jako możliwość sterowania wszystkimi układami i urządzeniami...
-
Octanoic Acid—An Insecticidal Metabolite of Conidiobolus coronatus (Entomopthorales) That Affects Two Majors Antifungal Protection Systems in Galleria mellonella (Lepidoptera): Cuticular Lipids and Hemocytes
Publication -
Knowledge-based functional safety management using ProSIL software
PublicationIn the article the ProSIL software for computer aided functional safety management is presented. The software consists of three modules for the determination of the required SIL level (ProSILen) and verification of the SIL level (ProSILver). In the ProSIL the calibrated knowledge-based risk graph method for determining the required safety integrity level (SIL) of the safety functions identified in hazard analysis is implemented....
-
Janusz Górski prof. dr hab. inż.
People -
Reliability data safety instrumented systems SIS from the functional safety analysis example critical instalation
Open Research DataThe dataset represents the results of an example of functional safety analysis systems is presented below. It is based on a control system, which consists of some basic components like sensors, programmable logic controllers and valves. It is a part of petrochemical critical installations. The communication between sensor logic controllers and actuators...
-
Paweł Możejko dr hab.
People -
Modeling organic nitrogen conversions in activated sludge bioreactors
PublicationFor biological nutrient removal (BNR) systems designed to maximize nitrogen removal, the effluent total nitrogen (TN) concentration may range from 2.0 to 4.0 g N/m3 with about 25-50% in the form of organic nitrogen (ON). In this study, current approaches to modeling organic N conversions (separate processes vs. constant contents of organic fractions) were compared. A new conceptual model of ON conversions was developed and combined...
-
Integrated safety and security analysis of hazardous plants and systems of critical infrastructure
PublicationThis article addresses an integrated safety and security analysis approach of hazardous industrial plants and systems of critical infrastructure. Nowadays due to new hazards that emerge there are opinions among experts that these issues require an integrated approach in life cycle, from the design concept, through the design and operation of the plant, to its decommissioning. It is proposed to start from an interesting methodology...
-
Dissolved and colloidal organic nitrogen removal from WWTP effluents and reject waters using physical-chemical processes
PublicationFour physical-chemical processes were compared in terms of the efficiencies of dissolved and colloidal organic nitrogen (DON and CON) removal from the secondary effluents (SE) and reject water from full-scale biological nutrient removal activated sludge systems. Adsorption on activated carbon was most efficient and allowed to remove from the SE up to 80% and 100% of DON and CON, respectively. High efficiencies of DON removal from...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
THE COST ANALYSIS OF CORROSION PROTECTION SOLUTIONS FOR STEEL COMPONENTS IN TERMS OF THE OBJECT LIFE CYCLE COST
PublicationSteel materials, due to their numerous advantages - high availability, easiness of processing and possibility of almost any shaping are commonly applied in construction for carrying out basic carrier systems and auxiliary structures. However, the major disadvantage of this material is its high corrosion susceptibility, which depends strictly on the local conditions of the facility and the applied type of corrosion protection system....
-
Modernized cathodic protection system for legs of the production rig – Evaluation during ten years of service
PublicationThe modernization of cathodic protection system of the Baltic Beta platform legs is described. It was that the sacrificial anodes cone-shaped groups were to be placed on the seabed at a depth of 80 m. The measurements results of cathodic protection effectiveness during its ten-years operation are presented. The effectiveness was assessed based on the potential value along the entire length of the legs from the sea surface to the...
-
The protection and monitoring of a distribution piping network for potable water supply
PublicationPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
Magdalena Gajewska prof. dr hab. inż.
PeopleMagdalena Gajewska (born June 1th 1968 in Gdańsk) in 1993 graduated Hydro-Engineering Faculty at Gdańsk University of Technology. At present she is an assistant professor in the Department of Water and Wastewater Technology at the Faculty of Civil and Environmental Engineering GUT. PhD (2001) and habilitation (2013) in the discipline of environmental engineering. In the 2016-2020 term, serves as Vice -dean for science. She...
-
Functional safety and reliability analysis methodoloogy for hazardous industrial plants
PublicationThis monograph is devoted to current problems and methods of the functional safety and reliability analyses of the programmable control and protection systems for industrial hazardous plants. The results of these analyses are useful in the process of safety management in life cycle, for effective reducing relevant risks at the design stage, and then controlling these risks during the operation of given installation. The methodology...
-
Adhesion of organic coatings to hot-dip galvanized steel
PublicationDuplex systems provide long-time corrosion protection, much longer than the sum of the lifetimes of zinc and paint used individually. However loss of adhesion between coating and zinc substrate is often found in practice. Different methods of zinc surface preparations are used in the fi eld. The aim of this study was to examine and compare coating protection when the old zinc surface, stored during long-time period (15 years) in...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Cost assessment of computer security activities
PublicationComprehensive cost-benefit analysis plays a crucial role in the decision-making process when it comes to investments in information security solutions. The cost of breaches needs to be analysed in the context of spending on protection measures. However, no methods exist that facilitate the quick and rough prediction of true expenditures on security protection systems. Rafal Leszczyna of Gdansk University of Technology presents...
-
Determining and verifying the safety integrity level with security aspects
PublicationSafety and security aspects consist of two different group of functional requirements for the control and protection systems. It is the reason why the analyses of safety and security shouldnt be integrated directly. The paper proposes extension of the currently used methods of functional safety analyses. It can be done with inclusion of the level of information security assigned to the technical system. The article addresses some...
-
Multisensor System for the Protection of Critical Infrastructure of Seaport
PublicationThere are many separated infrastructural objects within a harbor area that may be considered “critical”, such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons...
-
Increasing efficiency of technological process by limiting impact of corrosive environment on operation of spiral classifiers
PublicationMost of the technological operations related to the preparation of the output to be enriched and to the production of the final copper concentrate take place with the use of water environment. Water management, besides using innovative technical and technological solutions, is a significant factor in the whole copper ore enrichment process. Mine water resources and surface water of the tailing pond named "Żelazny Most" are the...