The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Energy quality improvement by ultra rapid L. V. fault current limiting andinterrupting.
PublicationPrzedstawiono możliwość ograniczania rozprzestrzeniania się zapadów napięcia w sieciach elektroenergetycznych przy zwarciach przez zastosowanie łączników hybrydowych do ultra szybkiego ograniczania i wyłączania prądów zwarciowych. Referat ma na celu przedstawienie dotychczasowych osiągnięć prac badawczych w dziedzinie łączników ultra szybkich, a także poznanie opinii elektroenergetyki i odbiorców na temat celowości wprowadzenia...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Residual current protective device for circuits of distorted earth fault currents – concept, construction and testing
PublicationThis dissertation presents behavioral and performance verification and analysis of residual current devices (RCDs), as well as a proposal for the construction of a new RCD protection. The state of the art focuses over pre-existing design of the RCD and its behavior and response to the circuits with distorted (non-sinusoidal) earth fault currents. The study highlights the loopholes of the existing design and depicts the problem...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Michał Grochowski dr hab. inż.
PeopleProfessor and a Head of the Department of Intelligent Control and Decision Support Systems at Gdansk University of Technology (GUT). He is also a Member of the Board of the Digital Technologies Center of GUT. He received his M.Sc. degree in Control Engineering in 2000 from the Electrical and Control Engineering Faculty at the GUT. In 2004 he received a Ph.D. degree in Automatic Control and Robotics from this...
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
The effect of current delay angle on tripping of residual current devices
PublicationPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Electric shock hazard in circuits with variable-speed drives
PublicationThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Residual current devices in installations with PV energy sources
PublicationThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublicationIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Use of Neural Networks in Diagnostics of Rolling-Element Bearing of the Induction Motor
PublicationBearing defect is statistically the most frequent cause of an induction motor fault. The research described in the paper utilized the phenomenon of the current change in the induction motor with bearing defect. Methods based on the analysis of the supplying current are particularly useful when it is impossible to install diagnostic devices directly on the motor. The presented method of rolling-element bearing diagnostics used indirect...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery
PublicationIn the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublicationThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Earth wires currents calculation by tableau analysis
PublicationThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
СИСТЕМА КОНТРОЛЯ СОСТОЯНИЯ ИЗОЛЯЦИИ ЭЛЕКТРОПРИВОДОВ В СЕТЯХ С ГЛУХОЗАЗЕМЛЕННОЙ НЕЙТРАЛЬЮ (System of insulation status monitoring for electric drives in networks with a dead-earth neutral)
PublicationПредложен метод контроля изоляции частотно-регулируемых электроприводов в сетях с глухозаземленной нейтралью. Система контроля изоляции включается в момент остановки электропривода. Ключи инвертора коммутируются по специальному закону, и с помощью сигнала трансформатора тока, который изме- ряет ток во всех трех фазах привода одновременно, определяется ток утечки. Рассмотрена схема датчика тока утечки и приведены экспериментальные...
-
Detection of inter-turn faults in transformer winding using the capacitor discharge method
PublicationThe paper presents results of an analysis of inter-turn fault effects on the voltage and current waveforms of a capacitor discharge through transformer windings. The research was conducted in the frame of the Facility of Antiproton and Ion Research project which goal is to build a new international accelerator facility that utilizes superconducting magnets. For the sake of electrical quality assurance of the superconducting magnet...
-
Stability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
PublicationThe stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...