Filters
total: 3387
filtered: 2341
displaying 1000 best results Help
Search results for: mesurments
-
Luminescent properties of Tb and Eu activated AxB1-xAlO3 (A = Y, Lu, Gd; B = Lu; x = 0, 0.5, 1) mixed oxides crystals prepared by micro-pulling-down method
Publication -
Analysis of TL and OSL kinetics of lithium aluminate
Publication -
Study of radioluminescence in LiMgPO4 doped with Tb, B and Tm
Publication -
Radial distribution of dose within heavy charged particle tracks – Models and experimental verification using LiF:Mg,Cu,P TL detectors
Publication -
Thermoluminescence kinetics of undoped and doped (Ti, Cu, Ce) lithium aluminate crystals
Publication -
Thermoluminescent response of differently doped lithium magnesium phosphate (LiMgPO4, LMP) crystals to protons, neutrons and alpha particles
Publication -
Detection of neutrons with LiF fluorescent nuclear track detectors
Publication -
Thermoluminescence and optically stimulated luminescence studies on LiMgPO4 crystallized by micro pulling down technique
Publication -
Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions
Publication -
A simplified numerical approach to non-radiation induced high-temperature signals in thermoluminescence. GlowVIEW – a useful tool for a multiple glow-curve analysis
Publication -
Comparative studies on OSL properties of LiMgPO4:Tb,B powders and crystals
Publication -
Investigations of the influence of Am-241 photons on the measured alpha particle response of luminescent materials
Publication -
OSL and RL of LiMgPO4 crystals doped with rare earth elements
Publication -
Position of LiF:Mg,Cu,P TL peak as an alternative method for ultra-high-dose dosimetry
Publication -
Radio-photoluminescence of highly irradiated Lif:Mg,Ti and Lif:Mg,Cu,P detectors
Publication -
New OSL detectors based on LiMgPO4 crystals grown by micro pulling down method. Dosimetric properties vs. growth parameters
Publication -
Spectral characteristic of high-dose high-temperature emission from LiF:Mg,Cu,P (MCP-N) TL detectors
Publication -
Analysis of TL and OSL kinetics in lithium magnesium phosphate crystals
Publication -
Composite thermoluminescent detectors based on the Ce3+ doped LuAG/YAG and YAG/LuAG epitaxial structures
Publication -
Response of thermoluminescence dosemeters statically exposed to X-ray radiation
Publication -
Optical readout of superheated emulsions
Publication -
Luminescence of CaWO4:Pr3+ and CaWO4:Tb3+ at ambient and high hydrostatic pressures
Publication -
Luminescence of Ca(NbO3)2:Pr3+: Pr3+ and self-trapped exciton emission
Publication -
Performance of a new commercial high-definition 3D patient specific quality assurance system for CyberKnife robotic radiotherapy and radiosurgery
PublicationConventional two dimensional and low-definition measurement techniques for dosimetric verification of radiotherapy treatment deliveries are no longer adequate in the era of hypofractionation and extremely high dose gradients. New quality assurance (QA) tools with 3D capability and high definition are urgently needed. The purpose of this study was to evaluate the performance of one of the first such commercial systems as applied...
-
Analysis of temporary steel grandstand with different bracing systems exposed to crowd load
PublicationGrandstands are structures which are regularly subjected to dynamic loads generated by crowd motions. It is a dangerous situation when spectators induce rhythmic jumping, dancing, stamping, etc. If the synchronized movement of spectators excites a natural frequency of the structure, resonant response might occur. To avoid such situations, temporary steel grandstands are commonly strengthened using additional elements that create...
-
Experimental study of the effect of vertical acceleration component on the slope stability
PublicationThe paper deals with the stability of earth dams subjected to seismic and paraseismic excitations occurring in the close distance to the dam. The Newmark’s stability approach, classified as a simplified dynamic method, has been extended for two directional dynamic loading case and the evolution of the friction coefficient. The paper is focused on the experimental verification of the proposed method for harmonic and cyclic excitations...
-
Vertical vibration reduction and audible sound analysis in surface grinding with electroplated tools
PublicationOne of the first approaches to the development of a grinding process monitoring system based on audible sound sensors is presented in the paper. Electroplated diamond tools (abrasive D64 and D107) were used in a modified single-disc lapping machine configuration for flat grinding of ceramics (Al2O3). The main aim of the machine modification was to reduce the vertical vibration in order to decrease the tool wear and to increase...
-
Low frequency noise measurements in advanced silocon devices.**2003, 136 s.116 rys. bibliogr. 29 poz. maszyn. Pomiary małoczęstotliwościowych szumów zaawansowanych elementów krzemowych. Rozprawa doktorska /15.04.2003./ Inst. Natl. P. Grenoble Promotorzy: prof. dr hab. inż. L. Spiralski, dr CNRS G. Ghibaudo.
PublicationW pracy przedstawiono automatyczny system do pomiarów małoczęstotliwoscio-wych szumów struktur elementów półprzewodnikowych. System umożliwia automa-tyczne wyznaczanie charakterystyk stałoprądowych badanego elementu, pomiarszumów i wyznaczanie gęstości widmowej mocy w zadanym zakresie polaryzacji.Przytoczono wyniki przeprowadzonych testów systemu. Ważną składową pracy wy-niki pomiarów szumów tranzystorów MOS i bipolarnych...
-
Design and Application of Magnetic Photocatalysts for Water Treatment. The Effect of Particle Charge on Surface
PublicationCore-interlayer-shell Fe3O4/SiO2/TiO2, CoFe2O4/SiO2/TiO2 and BaFe12O19/SiO2/TiO2 magnetic photocatalysts were obtained. A water-in-oil microemulsion system with suitable surfactants was used for functionalization of the magnetic core with silica interlayer and TiO2-based photocatalyst. Uncoated and coated particles were characterized by electrophoretic meaurements, X-ray diffractometry (XRD), scanning electron microscopy (SEM),...
-
Analysis of transformer state by fuzzy TOPSIS and AHP method
PublicationThe paper presents mathematical models TOPSIS and AHP methods, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine the importance of these measurements methods with this mathematical apparatus in these measurements methods in insulating state of transformers.
-
Mathematical analysis of transformer insulation state by means of composite indicator
PublicationThe paper is presenting mathematical model – composite indicator (CI), which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine importance of these measurements methods with this mathematical apparatus in these measurements methods in insulating state of transformers.
-
A Combined TOPSIS and FA Based Strategic Analysis of Technical Condition of High Power Transformers
PublicationThe paper presents mathematical model { TOPSIS method, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine the importance of these measurements methods with this mathematical appara- tus in these measurements methods in insulating state of transformers.
-
Rapid on-line method of wastewater parameters estimation by electronic nose for control and operating wastewater treatment plants toward Green Deal implementation
PublicationIn order to comply with legal regulations related to wastewater quality, the operational mode of facilities at wastewater treatment plant (WWTP) should be properly adjusted according to parameters of influents, however it is very difficult without frequently performed measurements. Currently there are known many techniques and devices for assesment of wastewater parameters such as chemical oxygen demand, biochemical oxygen demand,...
-
Crystal structure and low-energy Einstein mode in ErV2Al20 intermetallic cage compound
PublicationSingle crystals of a new ternary aluminide ErV2Al20 were grown using a self-flux method. The crystal structure was determined by powder X-ray diffraction measurements and Rietveld refinement, and physical properties were studied by means of electrical resistivity, magnetic susceptibility and specific heat measurements. These measurements reveal that ErV2Al20 is a Curie-Weiss paramagnet down to 1.95 K with an effective magnetic...
-
Uncertainty analysis of measuring system for instantaneous power research
PublicationThe paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped...
-
Comparison of new position estimation algorithm for indoor environment
PublicationIn the paper a new position estimation algorithm based on distance measurements is presented. This algorithm is dedicated for indoor environments. In the paper the new algorithm is compared with Chan algorithm. For the comparison were used real measurements conducted inside a building.
-
Robust estimation of deformation from observation differences for free control networks
PublicationDeformation measurements have a repeatable nature. This means that deformation measurements are performed often with the same equipment, methods, geometric conditions and in a similar environment in epochs 1 and 2 (e.g., a fully automated, continuous control measurements). It is, therefore, reasonable to assume that the results of deformation measurements can be distorted by both random errors and by some non-random errors, which...
-
Velocity measurement using the fdoa method in ground-based radio navigation system
PublicationVelocity is one of the main navigation parameters of the moving objects. However some systems of position estimation using radio wave measurements cannot provide velocity data due to limitation of their performance. In this paper a velocity measurement method for DS-CDMA radio navigation system is proposed, which doesn’t require full synchronization of reference stations carrier frequencies. The article presents basics of FDOA...
-
Examination method of the effect of the incidence angle of laser beam on distance measurement accuracy to surfaces with different colour and roughness
PublicationInterest in the influence of the incidence angle of a laser beam to distance measurements can be seen in many areas of science and technology: geodesy, glaciology, archaeology, machine automation, and others. This paper presents results of measurements of the effect of the incidence angle of a laser beam to distance measurements to the surfaces of different colour and roughness by Topcon's electro-optical total station with an...
-
Estimation of transmission quality in cellular systems based on indicators measured by the radio module
PublicationThe article presents a measurement stand for testing transmission quality in cellular systems such as LTE, NB-IoT, UMTS and GSM. The results of BLER and throughput measurements for various propagation conditions as well as results of quality indicators appropriate for mentioned technologies measured by commercial radio module are presented. Those measurements were utilized to analyze the possibility of estimating the transmission...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublicationThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublicationGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
Influence of Sn and Pb Ions Substitutions on Dielectric Properties of Barium Titanate
PublicationThe results of the microstructural and dielectric measurements of (Ba1-xPbx)(Ti1-xSnx)O3 (BPTSx) (x = 0, 0.05, 0.10, 0.30) polycrystalline samples are presented. The samples were obtained by means of a high temperature synthesis and their expected stoichiometry was confirmed by energy dispersive spectroscopy (EDS) measurements. The dielectric properties of BPTSx were studied with the use of broadband dielectric spectroscopy. The...
-
Adjustment for shape restoration and force control of cable arch stayed bridges
Publication -
Electrohydrodynamic secondary flow and particle collection efficiency in spike-plate multi-electrode electrostatic precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flow measurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIV measurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Design and modeling of the piezoelectric motor based on three resonance actuators
PublicationThis paper describes a piezoelectric motor which combines advantages from two existing piezoelectric motors topologies. The research work presents the design, simulations and measurements of the piezoelectric motor with three rotation-mode actuators. The aim of the project was to obtain the high speed piezoelectric motor. Other advantages of this conception are blocking torque, short response times, the ability to work in a hostile...
-
New Method for Determination of Adjustment Corrections for Crane Rail Axes
PublicationElectronic tacheometers are currently a standard instrument used in geodetic work, including also geodetic engineering measurements. One of the many applications of tacheometers in engineering geodesy are 3D control measurements of crane rail axes. This paper proposes a new method of computing adjustment corrections for crane rail axes based on 3D polar measurements performed with an electronic tacheometer. The intermediary method...
-
Person Tracking in a Ferry Environment Using Ultra-Wide Band Radio Interface
PublicationThis article presents research and analysis of effectiveness of tracking moving people in an environment of passenger ferry, using measurements of propagation time of ultra-wide band radio signal (UWB - Ultra-Wide Band). Constructed measurement stand and results of measurements carried out in a real propagation conditions were shortly discussed.
-
Low-coherence photonic method of electrochemical processes monitoring
PublicationWe present an advanced multimodality characterization platform for simultaneous optical and electrochemical measurements of ferrocyanides. Specifcally, we combined a fber-optic Fabry– Perot interferometer with a three-electrode electrochemical setup to demonstrate a proof-ofprinciple of this hybrid characterization approach, and obtained feasibility data in its monitoring of electrochemical reactions in a boron-doped diamond flm...