Filters
total: 2206
filtered: 1626
displaying 1000 best results Help
Search results for: CYANIDE DETERMINATION
-
Modern approach for determination of lactulose, mannitol and sucrose in human urine using HPLC-MS/MS for the studies of intestinal and upper digestive tract permeability
PublicationA new analytical procedure was described for the simultaneous determination of lactulose, mannitol and sucrose in urine, in which HILIC chromatography and tandem mass spectrometry detection are used. Sugars are orally administered for the estimation of intestinal permeability in children digestive tract. Samples were purified by dispersive solid phase extraction (d-SPE) using Amberlite MB150 resin. Raffinose was selected as an...
-
Application of analytical procedure based on accelerated solvent extraction and ion chromatography technique for determination of thiocyanate and other inorganic ions in human placenta samples
PublicationExposure of a pregnant woman during pregnancy is a special case of exposure to toxic substances. Samples of placenta collected for the studies had been prepared with the technique of accelerated solvent extraction and later analyzed for the presence of thiocyanate ion and other inorganic ions, with the use of the technique of ion chromatography. The concentration of thiocyanate ion in placenta samples collected from active smokers...
-
Development of a new green analytical methodology for the determination of phthalates in single-use babies diapers using ultrasound-assisted extraction and polypropylene porous membrane
PublicationA green extraction strategy was developed and utilized for the extraction and determination of phthalates. The extraction is based on ultrasound-assisted extraction and a polypropylene porous membrane. The Box-Behnken model was performed to optimize the extraction condition. The optimal extraction conditions are 5.5 mL of ethyl acetate, 10 min of extraction time and 55 C for extraction temperature. The developed green extraction...
-
Modification of gradient HPLC method for determination of small molecules' affinity to human serum albumin under column safety conditions: Robustness and chemometrics study
PublicationIn the early stages of drug discovery, beyond the biological activity screening, determining the physicochemical properties that affect the distribution of molecules in the human body is an essential step. Plasma protein binding (PPB) is one of the most important investigated endpoints. Nevertheless, the methodology for measuring %PPB is significantly less popular and standardized than other physicochemical properties, like lipophilicity....
-
Accurate Modeling of Frequency Selective Surfaces Using Fully-Connected Regression Model with Automated Architecture Determination and Parameter Selection Based on Bayesian Optimization
PublicationSurrogate modeling has become an important tool in the design of high-frequency structures. Although full-wave electromagnetic (EM) simulation tools provide an accurate account for the circuit characteristics and performance, they entail considerable computational expenditures. Replacing EM analysis by fast surrogates provides a way to accelerate the design procedures. Unfortunately, modeling of microwave passives is a challenging...
-
Determination of polycyclic aromatic hydrocarbons (PAHs) and other organic pollutants in freshwaters on the western shore of Admiralty Bay (King George Island, Maritime Antarctica).
PublicationOrganic contamination in freshwater samples has never been investigated at the western shore of Admiralty Bay. Therefore, the presence of polycyclic aromatic hydrocarbons (PAHs) in five different sites distributed along a shore running from the Arctowski Station to the Baranowski Glacier was studied. Moreover, organic compounds such as n-alkanes, toluene and ethylbenzene were also noted. Increased ΣPAHs in late Austral summer 2016...
-
Simultaneous voltammetric determination of Cd2+, Pb2+, and Cu2+ ions captured by Fe3O4@SiO2 core-shell nanostructures of various outer amino chain length
PublicationIn the present study, we examined a novel functionalised magnetic nanoparticles Fe3O4@SiO2-Nn as a nano adsorbent for binding of Cd2+, Pb2+, Cu2+ ions in an aqueous solution. First, we obtained the nanoparticles functionalised with various carbon chains containing different number of amino groups: (3-amino)propyltriethoxysilane (Fe3O4@SiO2-N1), N-(2-aminoethyl)-3-aminopropyltrimethoxysilane (Fe3O4@SiO2-N2) and N1-(3-trimethoxysilylpropyl)diethylenetriamine...
-
Application potential of dummy molecularly imprinted polymers as solidphase extraction sorbents for determination of low-mass polybrominated diphenyl ethers in soil and sediment samples
PublicationDespite the introduction of restrictive regulations in the USA and the European Union, polybrominated diphenyl ethers (PBDEs) are still found in various types of environmental and biological samples at significant concentration levels. The presence of these persistent organic pollutants in the environment raises important issues because of their negative impact on immunological and neurological systems, and on the hormonal balances...
-
Decomposition of the induced magnetism degaussing problem for fast determination of currents in demagnetization coils wrapped outside an object under arbitrary external field conditions
PublicationSafe passage of ships in the presence of sea mines can be ensured by limiting or reducing the ship’s magnetic footprint. For vessels with plastic hulls, the main component that requires magnetic damping is the engine. Demagnetization of such an object can be achieved by wrapping it with coils and setting the direct current appropriately. For each specific geographic location, the currents in the coils can be determined iteratively...
-
Application of normal-phase high-performance liquid chromatography followed by gas chromatography for analytics of diesel fuel additives
PublicationThe paper presents the results of investigations on new procedures of determination of selected cleaning additives in diesel fuel. Two procedures: one-step analysis using gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS) and a two-step procedure in which normal-phase high-performance liquid chromatography (NP-HPLC) was used for preliminary separation of the additives, were compared. The additive...
-
Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS)
PublicationThe paper presents the results of investigations on new procedures of determination of selected cleaning additives in diesel fuel. Two procedures: one-step analysis using gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS) and a two-step procedure in which normal-phase high-performance liquid chromatography (NP-HPLC) was used for preliminary separation of the additives, were compared. The additive...
-
Optimisation of pressurised liquid extraction for elimination of sulphur interferences during determination of organotin compounds in sulphur-rich sediments by gas chromatography with flame photometric detection
PublicationOpracowano metodę analizy osadów dennych na zawartość związków cynoorganicznych (MBT, DBT, TBT, MPhT, DPhT, TPhT) przy użyciu przyspieszonej ekstrakcji rozpuszczalnikiem i chromatografii gazowej z detektorem płomieniowo-fotometrycznym. Detektor ten pozwala selektywnie wykrywać niewielkie ilości pochodnych cynoorganicznych. Niestety, bardzo często spotykana w osadach siarka oraz jej pochodne zakłócają sygnał detektora. Z tego względu...
-
Application of dispersive liquid-liquid microextraction and gas chromatography with mass spectrometry for the determination of oxygenated volatile organic compounds in effluents from the production of petroleum bitumen
PublicationWepresent a new procedure for the determination of oxygenated volatile organic compounds in samples of postoxidative effluents from the production of petroleum bitumens using dispersive liquid–liquid microextraction and gas chromatography with mass spectrometry. The eight extraction parameters were optimized for 43 oxygenated volatile organic compounds. The detection limits obtained ranged from 0.07 to 0.82 g/mL for most of the...
-
Determination of pharmaceutical residues in drinking water in Poland using a new SPE-GC-MS(SIM) method based on Speedisk extraction disks and DIMETRIS derivatization
Publication -
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publication -
Determination of tributyltin in marine sediment: Comit� Consultatif pour la Quantit� de Mati�re (CCQM) pilot study P-18 international intercomparison
Publication -
Spectrofluorometrical Determination of Vitamin B 1 in Different Matrices Using Box‐Behnken Designed Pipette Tip Solid Phase Extraction by a Carbon Nanotube Sorbent
Publication -
Application of molecularly imprinted polymer pipette tip micro-solid phase extraction of nalidixic acid and acetaminophen from pills and seawater samples and their determination by spectrophotometry
Publication -
Fast determination of bisphenol A in spiked juice and drinking water samples by pipette tip solid phase extraction using cobalt metal organic framework as sorbent
Publication -
Application of In-Syringe Dispersive Liquid–Liquid Microextraction and Narrow-Bore Tube Dispersive Liquid–Liquid Microextraction for the Determination of Trace Amounts of BTEX in Water Samples
Publication -
DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN SOIL SAMPLES USING ULTRASONIC PROBE AND SALT-ASSISTED LIQUID-LIQUID EXTRACTION COUPLED WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
Publication -
Determination of mefenamic acid in urine and pharmaceutical samples by HPLC after pipette-tip solid phase microextraction using zinc sulfide modified carbon nanotubes
Publication -
Application of response surface methodology to optimize pipette tip micro-solid phase extraction of dyes from seawater by molecularly imprinted polymer and their determination by HPLC
Publication -
Fabrication of a Molecularly Imprinted Polymer Adsorbent for Pipette Tip Micro Solid-phase Extraction of Levofloxacin from Aqueous Samples Prior to its Spectrophotometric Determination
Publication -
Określenie szybkości korozji stopu AlSi13Mg1CuNi nadtopionego laserowo w warunkach kriogenicznych = Corrosion rate determination of AlSi13Mg1CuNi alloy laser remelted at cryogenic conditions
PublicationW pracy przedstawiono wyniki badania szybkości korozji stopu AlSi13Mg1CuNi nadtopionego laserowo w warunkach kriogenicznych. Stop eksponowano w 0,01 M roztworze kwasu siarkowego H2SO4
-
Determination of free tyrosine in equestrian supplements by LC–MS/MS and comparison of its quantity with total free amino acids content in view of doping control
PublicationThe reports on the probable beneficial impact of tyrosine (TYR) supplementation on performance enhancement have contributed to the growth of interest in TYR in equestrian sports field and related industries, such as the manufacture of dietary and nutritional supplements. In this study, the first attempt to the assessment of horses exposure to TYR during nutritional supplementation was demonstrated by quantification of unbound TYR...
-
Determination of bromhexine and its metabolites in equine serum samples by liquid chromatography – Tandem mass spectrometry: Applicability to the elimination study after single oral dose
PublicationBromhexine (BH), expectorant used in the treatment of respiratory disorders associated with viscid or excessive mucus, is not permitted for use in the competing horse by many authorities in horseracing and Olympic disciplines. Metabolic studies are of the great importance in anti-doping field because they allow for updating the selection of the most appropriate markers for prohibited substances, such as metabolites present at higher...
-
Determination of phenylbutazone, sulfamethazine, carbendazim and linuron using a novel pine bark biosorbent for solid-phase extraction (SPE) with high-performance liquid chromatography (HPLC)
PublicationThe paper presents a novel pine bark based biosorbent for solid-phase extraction (SPE). The morphology and composition of the pine bark were characterized using Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The biosorbent was used for the preparation of wastewater for the determination of phenylbutazone, sulfamethazine, carbendazim, and linuron by high performance liquid chromatography with...
-
Natural deep eutectic solvent based ultrasound assisted liquid-liquid micro-extraction method for methyl violet dye determination in contaminated river water
PublicationSimple and green natural deep eutectic solvent (NADES) based ultrasound assisted liquid-liquid micro-extraction (UA-LLME) method was developed for extraction and determination of methyl violet dye in contaminated river water samples using UV/Vis spectrophotometry. Choline chloride - decanoic acid based natural deep eutectic solvent was used for extraction. Important analytical parameters like pH, deep eutectic solvent volume/phase...
-
Ultrasound assisted dispersive solid phase microextraction using polystyrene-polyoleic acid graft copolymer for determination of Sb(III) in various bottled beverages by HGAAS
PublicationA new polyoleic acid-polystyrene (PoleS) block/graft copolymer was synthesized and applied as adsorbent for ultrasound assisted dispersive solid phase microextraction (UA-DSPME) of Sb(III) in different bottled beverages and analysis using hydride generation atomic absorption spectrometry (HGAAS). Adsorption capacity of the PoleS was 150 mg g−1. Several sample preparation parameters such as sorbent amount, solvent type, pH, sample...
-
Problemy z oznaczaniem zawartości fazy stałej z zastosowaniem normy ISO 8292 = Problems with the solid fat content determination using the ISO 8292 standard.
PublicationZawartość fazy stałej (SFC) jest parametrem charakteryzującym właściwości fizyczne i użytkowe tłuszczów stałych. Otrzymanie prawidłowego wyniku zależy od zastosowania odpowiedniej procedury termostatowania próbki przed pomiarem, a ta z zależy od rodzaju badanego tłuszczu. Przed oznaczeniem SFC wszystkie TAG, które są stałe w temperaturze 0oC powinny wykrystalizować, a tłuszcz osiągnąć trwałą formę krystaliczną. Pierwsza norma IUPAC...
-
Determination of eight artificial sweeteners and common Stevia rebaudiana glycosides in non-alcoholic and alcoholic beverages by reversed-phase liquid chromatography coupled with tandem mass spectrometry.
PublicationThe method for the determination of acesulfame-K, saccharine, cyclamate, aspartame, sucralose, alitame, neohesperidin dihydrochalcone, neotame and five common steviol glycosides (rebaudioside A, rebaudioside C, steviol, steviolbioside and stevioside) in soft and alcoholic beverages was developed using high-performance liquid chromatography and tandem mass spectrometry with electrospray ionisation (HPLC-ESI-MS/MS). To the best of...
-
Determination of parent and methylated polycyclic aromatic hydrocarbons in water samples by dispersive liquid–liquid microextraction–two dimensional gas chromatography–time-of-flight mass spectrometry
PublicationPolycyclic aromatic hydrocarbons (PAHs) are contaminants frequently found in environmental waters. Owing to their toxic effects, it is important to develop analytical methodologies that allow their fast and reliable determination. Dispersive liquid–liquid microextraction (DLLME) allows a quick extraction of analytes with little organic solvent consumption. The best results regarding sample preparation are obtained when 40 mL of...
-
Przegląd metod oznaczania pozostałości pestycydów i polichlorowanych bifenyli w próbkach żywności = Methods of determination of residues of pesticides and polychlorinated biphenyls in food samples - a review
PublicationOznaczanie pozostałości pestycydów i analitów z grupy polichlorowanych bifenyli w próbkach żywności wymaga zastosowania specyficznych technik w zakresie przygotowania próbki do analizy, jak i samych technik analizy instrumentalnej, pozwalających na uzyskanie bardzo niskiej granicy oznaczalności. Problemem związanym ze stosowaniem związków z grupy pestycydów i polichlorowanych bifenyli jest konieczność kontroli ich pozostałości...
-
Comparison of hydrophilic interaction and reversed phase liquid chromatography coupled with tandem mass spectrometry for the determination of eight artificial sweeteners and common steviol glycosides in popular beverages
PublicationHydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim™ Trinity™ P2) the last one was selected for the development of HILIC method due to the best results obtained with it. Early eluting and coeluting compounds...
-
Novel liquid chromatography method based on linear weighted regression for the fast determination of isoprostane isomers in plasma samples using sensitive tandem mass spectrometry detection
PublicationA simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography–tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F2α, 8-iso-15(R)-prostaglandin F2α, 11β-prostaglandin F2α, 15(R)-prostaglandin F2α) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the...
-
Use of porous glass and silica gel as support media of a surface compound for generation of analytes in gaseous standard mixtures. New method for the determination of the amount of analyte generated
Publication -
Wyznaczanie współczynników dyfuzji tlenku węgla (IV) przez membrany wysycone cieczą jonową = Determination of carbon dioxide diffusion coefficients in supported ionic liquids membranes
PublicationWykazano możliwość zastosowania imidazoliowych cieczy jonowych osadzonych na nośnikach polimerowych SILM (supported ionic liquids membranes) do absorpcji CO2. W badaniach wykorzystano sole imidazoliowe posiadające w strukturze aniony fluoroalkilowe typu [Tf2N] i [TfO], które selektywnie separują tlenek węgla (IV). Wyznaczono współczynniki dyfuzji CO2 przez poszczególne SILM na podstawie ilości dyfundującego CO2 przez powierzchnię...
-
Determination of profenofos in seawater and foodstuff samples after its molecularly imprinted polymer pipette-tip micro solid phase extraction optimized by response surface methodology
Publication -
Application of response surface methodology for optimization of metal–organic framework based pipette-tip solid phase extraction of organic dyes from seawater and their determination with HPLC
Publication -
Comparison of Air-Assisted, Vortex-Assisted and Ultrasound-Assisted Dispersive Liquid–Liquid Microextraction for the Determination of BTEX Compounds in Water Samples Prior to GC-FID Analysis
Publication -
Multi-residue method for the determination of 16 recently used pesticides from various chemical groups in aqueous samples by using DI - SPME coupled with GC-MS
PublicationA simple and solvent-free multi-residue method has been optimized to determine 16 currently used pesticides from different chemical groups in aqueous samples. The extraction of analytes was carried out with direct immersion solid-phase microextraction (DI-SPME) and for the identification and quantitative determination gas chromatography coupled with mass spectrometry (GC-MS) was applied. Two commonly used adsorbent coatings have...
-
Sensitive method for determination of benzoic acid in beverages and food samples using air–assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction
PublicationA simple, reliable and rapid air–assisted hydrophobic deep eutectic solvent-based dispersive liquid–liquid microextraction (AA-HDES-DLLME) was developed for analysis of benzoic acid in various beverages and food samples. The final determination stage was performed via UV–visible spectrophotometry. The key parameters (extraction time, HDES type and volume, dispersant volume, pH and sample volume) of the AA-HDES-DLLME method were...
-
Ultrasound assisted solvent extraction of porous membrane-packed samples followed by liquid chromatography-tandem mass spectrometry for determination of BADGE, BFDGE and their derivatives in packed vegetables
PublicationThe problem of the presence of trace organic pollutants in food is of growing importance due to increasing awareness about their impact on newborns, infants and adults of reproductive age. Despite the fact that packaged food products offer many advantages, packaging can be a source of contamination for stored food. Thus, monitoring such pollution in food is of high importance. In this work, a novel methodology based on the solvent...
-
Chromium‑based metal organic framework for pipette tip micro‑solid phase extraction: an effective approach for determination of methyl and propyl parabens in wastewater and shampoo samples
PublicationAbstract Background A chromium-based metal organic framework was synthesized and employed as an efficient sorbent for pipette tip micro-solid phase extraction and preconcentration of parabens from wastewater and shampoo samples up to sub-ppb level before their spectrophotometric analysis. Results Factors affecting preconcentration including volume and type of solvent, amount of sorbent, number of extraction, and volume and pH of...
-
Current trends in analytical strategies for determination of polybrominated diphenyl ethers (PBDEs) in samples with different matrix compositions – Part 1.: Screening of new developments in sample preparation
PublicationPolybrominated diphenyl ethers (PBDEs) are ubiquitous compounds in the environment. Restrictions on the use of PBDEs introduced at the beginning of the 21st century have not eliminated these highly persistent and bioaccumulative compounds from the environment. Despite many existing regulations to control and phase out, extensive research on PBDEs is still necessary to fully evaluate the hazard their create to the environment. In...
-
Volterra series usefulness in modelling of the time-domain cross-talk phenomena in coupled microstrip lines with nonlinear termination
PublicationW pracy przedyskutowano możliwość wykorzystania szeregów Volterry do analizy zjawiska przesłuchu w sprzężonych liniach mikropaskowych z nieliniowym obciążeniem. Apracowano algorytm metody, zaś uzyskane wyniki numeryczne zweryfikowano poprzez porównania z wynikami badań eksperymentalnych linii obciążonych w torze transmisyjnym diodą Schottky'ego.
-
Determination of tributylotin (TBT) in marine sediment using pressurised liquid extraction-gas chromatography-isotope dilution mass spectrometry (PLE-GC-IDMS) with a hexane-tropolone mixture
PublicationOpracowano metodę oznaczania zawartości tributylocyny w próbkach osadu morskiego. Na etapie izolacji zastosowano technikę przyspieszonej ekstrakcji za pomocą roztworu tropolonu w heksanie.Na etapie oznaczeń końcowych wykorzystano technikę chromatografii gazowej, stosując metodę spektrometrii mas rozcieńczenia izotopowego. Wyznaczono parametry walidacyjne opracowanej metody: granicę wykrywalności, precyzję, poprawność i niepewność.
-
Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process
Publication -
Determination of tributyltin (TBT) in marine sediment using pressurised liquid extraction–gas chromatography–isotope dilution mass spectrometry (PLE–GC–IDMS) with a hexane–tropolone mixture
Publication