Search results for: INDOOR AIRFLOW
-
THE PROBLEM OF AIRFLOW AROUND BUILDINGS CLUSTERS IN DIFFERENT CONFIGURATIONS
PublicationIn the paper, the authors discuss the construction of a model of an exemplary urban layout. Numerical simulation has been performed by means of a commercial software Fluent using two different turbulence models: the popular k-ε realizable one, and the Reynolds Stress Model (RSM), which is still being developed. The former is a 2-equations model, while the latter – is a RSM model – that consists of 7 equations. The studies have...
-
The Analysis of Patients' Airflow with Respect to Early Detection of Sleep Apnea
PublicationThe paper discusses the analysis of the respiratory events of sleep apnea patients. The analysis was carried out on the basis of the patient's airflow. As a result of the conducted analysis we proposed an algorithm which establishes an individual respiratory pattern for each subject. The algorithm could be implemented in the measurement - control system which manages the prosthetic device applying positive airway pressure. Its...
-
INDOOR AND BUILT ENVIRONMENT
Journals -
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Comparative Analysis of Numerical and Experimental Studies of the Airflow Around the Sample of Urban Development
PublicationIn this paper, on the background of a short overview of the recent advances in the field of Environmental Wind Engineering (EWE), a comparison of wind tunnel experiment and numerical simulation for some cases of airflow around an urban layout have been reported. The purpose of the study is quantitative and qualitative comparison of measurements in the wind tunnel as well as numerical simulation using Ansys Fluent software. The...
-
Organic compounds in indoor environments
PublicationPraca jest przeglądem literaturowym dotyczącym obecności lotnych związków organicznych w powietrzu wewnętrznym. Zaprezentowano główne źródła zanieczyszczeń powietrza wewnętrznego, poruszono tematykę sumarycznej zawartości LZO oraz wpływu zanieczyszczeń powietrza atmosferycznego na jakość powietrza wewnętrznego.
-
Automated detection of sleep apnea and hypopnea events based on robust airflow envelope tracking
PublicationThe paper presents a new approach to detection of apnea/hypopnea events, in the presence of artifacts and breathing irregularities, from a single-channel airflow record. The proposed algorithm identifies segments of signal affected by a high amplitude modulation corresponding to apnea/hypopnea events. It is shown that a robust airflow envelope—free of breathing artifacts—improves effectiveness of the diagnostic process and allows...
-
Recent advances on SOA formation in indoor air, fate and strategies for SOA characterization in indoor air - A review
PublicationRecent studies proves that indoor air chemistry differs in many aspects from atmospheric one. People send up to 90 % of their life indoors being exposed to pollutants present in gas, particle and solid phase. Particle phase indoor is composed of particles emitted from various sources, among which there is an indoor source – secondary chemical reactions leading to formation of secondary organic aerosol (SOA). Lately, researchers'...
-
Indoor Air Quality: A Bibliometric Study
Publication -
Depolarisation Model for a BAN Indoor Scenario
PublicationIn this paper, an analysis of depolarisation in Body Area Networks for Body-to-Infrastructure communications based on a measurement campaign in the 5.8 GHz band in an indoor environment is performed. Measurements were made with an offbody antenna transmitting linearly polarised signals and dualpolarised receiving antennas carried by the user on the body. A Normal Distribution with a mean of 2.0 dB and a standard deviation of 4.3...
-
Reliable testbed for indoor positioning systems
PublicationThis paper proposes a test environment for indoor localization system, based on radio wave propagation prosperities. The following sections presents variety of problems from the assessment of the existing localization system to the analysis of inconveniences which occur when comparison of different localization systems is implemented. The problem is associated with different testing environments presented in published papers is...
-
Influence of terpenes on indoor air quality
PublicationThe aim of this study was to investigate air quality in hairdresser salons, focusing on terpenes determination. Terpenes are known reactive volatile organic compounds that contribute to secondary organic aerosol formation. Those compounds are frequently found in cosmetic products as fragrance agents. Hairdresser salons are special kind of environment, where secondary organic aerosol concentration may be elevated. One hairdresser...
-
A Review of Antennas for Indoor Positioning Systems
PublicationThis paper provides a review of antennas applied for indoor positioning or localization systems. The desired requirements of thoseantennas when integrated in anchor nodes (reference nodes) are discussed, according to different localization techniques and theirperformance. The described antennas will be subdivided into the following sections according to the nature of measurements:received signal strength (RSS), time of flight (ToF),...
-
Influence of input data on airflow network accuracy in residential buildings with natural wind - and stack - driven ventilation.
PublicationW artykule omówiono wpływ danych wejściowych na dokładność modelu przepływu sieciowego powietrza w budynkach mieszkalnych z naturalną i kominową wentylacją. Zastosowano połączony model AFN-BES. Wyniki numeryczne omówiono dla 8 różnych przypadków z różnymi danymi ciśnienia wiatru. Wyniki pokazały, że ogromny wpływ danych wejściowych dotyczących ciśnienia wiatru na wyniki numeryczne.
-
Passive samplers in indoor air quality control
PublicationPrzedstawiono wyniki badań jakości powietrza wewnętrznego w 12 wybranych mieszkaniach usytuowanych na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki pasywnej (dozymetria pasywna typu permeacyjnego) oraz techniki dynamicznej (rurki sorpcyjne wypełnione sorbentem Tenax TA). Wykorzystując nowe podejście do sposobu kalibracji dokonano monitoringu zarówno poszczególnych lotnych związków organicznych jak i sumarycznej zawartości...
-
Analysis of Position Calculating Methods in Indoor Environment
PublicationIn the paper a modified gradient method has been proposed for position calculation on basis of distance measurement in indoor environment. It is shown that the well-known Chan method of position calculation is inefficient in indoor circumstances. Author presents Chan and modified gradient methods and achieved results for each one for real measurements.
-
New Indoor Positioning Algorithm for Distance Measurements
PublicationIn the paper a new indoor positioning algorithm is presented. This algorithm takes into account selected features of radio wave propagation in indoor environment. This results in improvement in accuracy of calculated position estimates. A comparative analysis of this new algorithm with Chan and Foy algorithms was made and described in the paper. This comparative analysis was made with utilization of real radio distance measurements.
-
Electronic Noses for Indoor Air Quality Assessment
PublicationThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Energy efficient indoor localisation for narrowband internet of things
PublicationThere are an increasing number of Narrow Band IoT devices being manufactured as the technology behind them develops quickly. The high co-channel interference and signal attenuation was seen in edge Narrow Band IoT devices make it challenging to guarantee the service quality of these devices. To maximize the data rate fairness of Narrow Band IoT devices, a multi-dimensional indoor localization model is devised, consisting of...
-
Screening of volatile organic compounds as a source for indoor pollution
PublicationLotne związki organiczne (VOC) stanowią jedne z istotniejszychzanieczyszczeń powietrza wewnętrznego, ich stężenia w powietrzu wewnętrznym są często kilkakrotnie wyższe niż odpowiadające im stężenia w powietrzu zewnętrznym. Ten niekorzystny stosunek stężeń wskazuje na obecność endogennych źródeł emisji (usytuowanych bezpośrednio wewnątrz budynków). Lotne związki organiczne uwalniane są do powietrza wewnętrznego z wielu kontrolowanych...
-
Characteristics of the Polarised Off-Body Channel in Indoor Environments
PublicationThis paper addresses the depolarisation effect in off-body Body Area Networks channels, based on measurements performed at 2.45 GHz in an indoor environment. Seven different scenarios, involving both static and dynamic users, were considered, taking a statistical perspective. The analysis of the cross-polarisation discrimination is performed, as well as the analysis of path loss in co- and cross-polarised channels. Results show...
-
Comparison of new position estimation algorithm for indoor environment
PublicationIn the paper a new position estimation algorithm based on distance measurements is presented. This algorithm is dedicated for indoor environments. In the paper the new algorithm is compared with Chan algorithm. For the comparison were used real measurements conducted inside a building.
-
Hybrid System for a Person Tracking in Harsh Indoor Environments
PublicationIn the article, the prototype of a system for a person tracking in a harsh indoor environment, especially when no other commercially available radiolocalization system can be used, was briefly described. The prototype realizes the data fusion, i.e. combines data from inertial and environmental sensors and radio distance measurements to estimate the position of a moving person. It is worth noting that the concept and practical realization...
-
Indoor air quality in public utility environments-a review
PublicationIndoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the...
-
Single-Anchor Indoor Localization Using ESPAR Antenna
PublicationIn this paper a new single-anchor indoor localization concept employing Electronically Steerable Parasitic Array Radiator (ESPAR) antenna has been proposed. The new concept uses a simple fingerprinting algorithm adopted to work with directional main beam and narrow minimum radiation patterns of ESPAR antenna that scans 360° area around the base station, while the signal strength received from a mobile terminal is being recorded...
-
Characteristics of the polarised off-body channel in indoor environments
PublicationThis paper addresses the depolarisation effect in off-body body area networks channels, based on measurements performed at 2.45 GHz in an indoor environment. Seven different scenarios, involving both static and dynamic users, were considered, taking a statistical perspective. The analysis of the cross-polarisation discrimination is performed, as well as the analysis of path loss in co- and cross-polarised channels. Results show...
-
Hydrodynamics and Mass Transfer Analysis in BioFlow® Bioreactor Systems
Publication -
Polybrominated diphenyl ether (PBDE) concentrations in dust from various indoor environments in Gdańsk, Poland: Prediction of concentrations in indoor air and assessment of exposure of adults
PublicationMonitoring of polybrominated diphenyl ethers (PBDEs) in indoor environments involves the determination of their concentrations in air, airborne particles, and settled dust. Each of these is a source of human exposure to PBDEs. In this study, we attempted to model PBDEs concentrations in various typical indoor environments on the basis of real PBDEs measurements in dust collected from them. The analytical procedure for determining...
-
Measurements of Path Loss in Off-Body Channels in Indoor Environments
PublicationThe main goal of the paper is to investigate the influence of body orientation and on-body antenna placement on the path loss in off-body communications. In addition, the influence of different bodies is analysed.
-
Path Loss Analysis in Off-Body Channels in Indoor Environment
PublicationThis temporary document describes an analysis of path loss in off-body channels in an indoor environment. The influence of body orientation and on-body antenna placement on path loss in off-body communications as well as of different bodies has been investigated. Five static scenarios, six distances between body and antenna and eight body orientations were analysed; moreover, two dynamic scenarios were investigated. The smallest...
-
The Use of Sensory Analysis Techniques to Assess the Quality of Indoor Air
PublicationThe quality of indoor air is one of the significant elements that influences people's well-being and health inside buildings. Emissions of pollutants, which may cause odor nuisance, are the main reason for people's complaints regarding the quality of indoor air. As a result, it is necessary to perform tests aimed at identifying the sources of odors inside buildings. The article contains basic information on the characteristics...
-
An Empirical Model for the Polarisation Characteristics of Indoor Off-Body Channels
PublicationThis paper presents an analysis of the polarisation characteristics for the channel in dynamic off-body communications, and an empirical channel model, based on measurements performed at 2.45 GHz in an office environment. Body presence and propagation conditions have a strong influence on signal depolarisation. The model assumes three components for the total path loss: mean path loss, represented by a log-distance function with...
-
Measurements of Path Loss in Off-Body Channels in Indoor Environments
PublicationThis paper presents a measurements of the path loss for validation of a statistical model for off-body radio channels in an indoor multipath environment, which considers the distance dependent mean path loss, and describes body shadowing and fast fading components in a statistical way. The measurement equipment and propagation indoor environment have been presented. Two different bodies and five static and two walking scenarios...
-
Analysis of Accuracy of Modified Gradient Method in Indoor Radiolocalisation System
PublicationIn this paper a new method, called modified gradient method, has been proposed for position calculation on the basis of distance measurement in indoor environment. It is shown that well known method of position calculation such as Foy is inefficient in indoor environment. In this article is also described the indoor radiolocalisation system which was used for collecting distance measurements which were employed for further comparative...
-
LSTM-based method for LOS/NLOS identification in an indoor environment
PublicationDue to the multipath propagation, harsh indoor environment significantly impacts transmitted signals which may adversely affect the quality of the radiocommunication services, with focus on the real-time ones. This negative effect may be significantly reduced (e.g. resources management and allocation) or compensated (e.g. correction of position estimation in radiolocalisation) by the LOS/NLOS identification algorithm. This paper...
-
Monitoring and analytics of semivolatile organic compounds (SVOCs) in indoor air
PublicationThis paper reviews literature information on the behaviour of semivolatile organic compounds (SVOCs) in the indoor environment, as well as the most likely emission sources. The consecutive stages of analytical procedures used for monitoring SVOCs in indoor environments are described. The most common approaches used for collecting samples from the gas and particulate phases are mentioned. The paper discusses and compares various...
-
TiO2-based photocatalysts in indoor swimming pool air purification
PublicationWzrastająca ilość basenów kąpielowych i aquaparków jest obecnie wyzwaniem dla naukowców zajmujących się badaniem i kontrolowaniem powietrza hali basenowej. Mikroorganizmy powstałe w powietrzu hali stanowią ogromne zagrożenie dla zdrowia. Ponadto, w fazie gazowej obecne są także uboczne produkty dezynfekcji (DBP), które mogą mieć szkodliwy wpływ zarówno na kąpiących się, jak i personel. W pracy omówiono potencjalne zagrożenia spowodowane...
-
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublicationOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
-
Influence of external walls' thermal capacitance on indoor thermal comfort
PublicationThe doctoral thesis presents the results of numerical investigations on the influence of walls’ thermal capacitance on indoor thermal comfort. A proper set of thermal parameters of a building structure can considerably limit the heating / cooling demand, and passively increase the indoor thermal comfort. However the effect of building thermal capacitance on indoor conditions is complex and not always beneficial. Among a great number...
-
A picocellular UMTS/TDD overlay on GSM system for indoor environment
PublicationW pracy przedstawiono nakładkę CDMA na system GSM. Nakładka użytkuje system UMTS w trybie TDD i jest przeznaczona do funkcjonowania wewnątrz budynków w obszarze makrokomórki systemu GSM. Wyniki badań przedstawione w pracy ukazują znaczny wzrost efektywności wykorzystania tego samego pasma przez oba systemy i uzyskanie znacznej pojemności dla nakładki bez degradacji pracy systemu GSM
-
Path Loss Analysis for the IoT Applications in the Urban and Indoor Environments
PublicationThe Internet of Things (IoT) networks concept implies their presence in a various and untypical locations, usually with a disturbed radio signals propagation. In the presented paper an investigation of an additional path loss observed in an underground environment was described. The proposed measurement locations correspond to the operation areas of rapidly growing narrowband IoT (NBIoT) networks, the ones using the Long Term Evolution...
-
Wideband Channel Measurements for Polarised Indoor Off-Body Communications
PublicationThis paper presents the initial results of wideband channel measurements for polarised off-body communication at 5.8 GHz, in an indoor environment. Channel Impulse Response measurements were performed simultaneously for two orthogonal polarisations of the wearable antenna, and repeated for vertical and horizontal orientations of the off-body one. Four types of measurement scenarios were considered in order to investigate the influence...
-
Effects of stents under asymmetric inflow conditions
PublicationW publikacji rozważano komputerowe modele stentów przy niesymetrycznych warunkach napływu i ich wpływ na naprężenia styczne na ściankach. Umożliwia to znajdowanie kształtów stentów, które są mniej wrażliwe na brak symetrii napływu. Zmiany kształtów arterii można wiązać ze zmianami charakterystyki przepływów takimi jak m.in. naprężenia styczne na ściankach, które zwiększają ryzyko restenozy. Posłużono się również pojęciem dyssypacji...
-
Jakość powietrza wewnętrznego - lotne związki organiczne jako wskaźnik jakości powietrza wewnętrznego = Indoor air quality - volatile organic compounds as an indicator of the quality of indoor air
PublicationPomieszczenia zamknięte z jednej strony są barierą chroniącą przed negatywnymi czynnikami środowiska, zmiennymi warunkami pogodowymi - deszczem, wiatrem, niską lub wysoką temperaturą, z drugiej jednak strony - w zamkniętych wnętrzach nastepuje często kumulacja toksycznych związków organicznych i nieorganicznych, co nie pozostaje bez wpływu na ludzkie zdrowie.Głównym celem badań jest oszacowanie jakości powietrza wewnętrznego pod...
-
Determination of bisphenol A in size fractions of indoor dust from several microenvironments
Publication -
Indoor allergens in settled dust from kindergartens in city of Łódź, Poland
Publication -
An Off-Body Channel Model for Body Area Networks in Indoor Environments
PublicationThis paper presents an off-body channel model for body area networks (BANs) in indoor environments. The proposed model, which is based on both simulations and measurements in a realistic environment, consists of three components: mean path loss, body shadowing, and multipath fading. Seven scenarios in a realistic indoor office environment containing typical scatterers have been measured: five were static (three standing and two...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
RF Indoor Positioning System Supported by Wireless Computer Vision Sensors
PublicationIn this paper the possibility of increase the accuracy of RF fingerprinting indoor tracking system by the use of additional information from simple vision system is examined. As the distances in signal space differs from ones in real environment the ambiguity in decision process of fingerprinting algorithm can occur when set of closest distances between tag and map points in signal space corresponds to big distances differences...