displaying 1000 best results Help
Search results for: TRANSFORMER CONTROLLER
-
Coordination of generator transformer controller and multi-parameter generator controller regulation algotrithms
Publication -
Implementation of power transformer controlled switching algorithm
PublicationThe article presents two new algorithms of controlled switching the power transformer. The main aim of the paper is to obtain formulas that determine the moments of closing of the circuit breaker poles. The study contains projects of control systems for both algorithms. Mathematical formulas for the time instants of the breaker poles closing were developed on the basis of electric circuit theory and magnetic circuit theory. The...
-
SVC and power transformers controllers coordination
PublicationThe use of shunt compensators such as FACTS (for example SVC) in power systems gives possibility of fast and flexible control of voltage or reactive power. An efficient cooperation between a transformer and compensator connected to busbars, or transformer’s tertiary winding, requires a proper coordination of controls. The article contains theoretical considerations and simulation results which indicate that such co-ordination is...
-
Adaptacyjny regulator transformatora blokowego = Adaptive controller of generator transformer
PublicationW referacie przedstawiono koncepcję adaptacyjnego regulatora transformatora blokowego jako narzędzia do rozszerzenia ograniczeń generacji mocy biernej generatora synchronicznego.
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Multi-region fuzzy logic controller with local PID controllers for U-tube steam generator in nuclear power plant
PublicationIn the paper, analysis of multi-region fuzzy logic controller with local PID controllers for steam generator of pressurized water reactor (PWR) working in wide range of thermal power changes is presented. The U-tube steam generator has a nonlinear dynamics depending on thermal power transferred from coolant of the primary loop of the PWR plant. Control of water level in the steam generator conducted by a traditional PID controller...
-
INTEGRAL TRANSFORMS AND SPECIAL FUNCTIONS
Journals -
Analysis of transformer inrush currents
PublicationW artykule przedstawiono model i wyniki obliczeń prądu i strumienia magnetycznego w układzie zawierającym transformator trójfazowy i wyłącznik. Opracowano obwodowy model łącznika z łukiem elektrycznym. Model łuku zbudowano w oparciu o jego statyczną i dynamiczną charakterystykę prądowo-napięciową. Przeprowadzone symulacje wykazały, że wartość maksymalna prądu włączania transformatora zależy zarówno od chwili włączenia napięcia...
-
CONTROLLED CLINICAL TRIALS
Journals -
Multidirectional CATV transformers
PublicationZaproponowano nowe transformatory wielouzwojeniowe, nazwane tu transformatorami wielokierunkowymi, na zakres częstotliwości CATV od 5 MHz do 862 MHz, przeznaczone do zastosowania w separatorach multimedialnych jako pasywne dzielniki mocy. Zaprezentowano typowe charakterystyki zaprojektowanych transformatorów: jednokierunkowego, dwukierunkowego i czterokierunkowego, uzyskane w wyniku pomiarów, i porównano je z wynikami modelowania...
-
Transformer-Capsule Model for Intent Detection
Publication -
Analysis of leakage flux in deenergized transformer
PublicationThe article presents the numerical analysis of the magnetic field that occurs around the transformer after it has been switched off. The purpose of this analysis was to determine if it is possible to define the residual fluxes in the legs of transformer based on the measurements of this field. These studies have allowed us to determine the quantity and location of the sensors. The influence of the Earth's magnetic field has also...
-
Frequency Diagnostics of Transformer Insulating Parameters
PublicationIn the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...
-
Compact microstrip to coplanar standard transformer.
PublicationW pracy zaprezentowano transformator standardu umożliwiający bezodbiciowe połączenie linii mikropaskowej z linią koplanarną. Konstrukcja układu opiera się na założeniu zachowania jednakowej wartości impedancji w każdym przekroju poprzecznym struktury. Zaprojektowano i przebadano dwa rozwiązania z ze skokową i ciągłą zmianą szerokości linii. Do badań numerycznych wykorzystano symulator pełnofalowy Momentum. W symulacjach uwzględniono...
-
Transborder Economics: international journal on transborder economics, politics and statistics
Journals -
Modeling and control of a redundantly actuated variable mass 3RRR planar manipulator controlled by a model-based feedforward and a model-based-proportional-derivative feedforward–feedback controller
PublicationIn the paper, dynamics of a complex mechatronics system is considered. A redundantly actuated planar manipulator is the base of the mechanical part of it. It is a 3RRR 1 platform based parallel manipulator. To control its trajectory, a model-based feedforward controller is employed. Three aspects are fundamental in the presented investigations. The first focus is on development of an accurate numerical model used to solve the inverse...
-
Fuzzy track controller for ships.
PublicationPrzedstawiono projekt regulatora trajektorii zrealizowanego w oparciu o logikę rozmytą. Zadaniem regulatora jest sterowanie statkiem wzdłuż zadanej trajektorii z uwzględnieniem prędkości. Zadana trajektoria przedstawiona została w postaci linii łamanej z wyznaczona wartością prędkości z jaką statek ma poruszać się po każdym odcinku. Opracowane reguły sterowania regulatora rozmytego trajektorii poddane zostały badaniom na statku...
-
A simple modular active power electronic transformer
Publication -
Modelling and diagnostics of a traction transformer - a case study
PublicationW niniejszym artykule przedstawiono wyniki badań w dziedzinie diagnostyki kolei elektrycznych. Zostały one przeprowadzone przez międzynarodowe przemysłowo-akademickie konsorcjum w ramach projektu europejskiego (6-go programu ramowego). Skupiono się na modelowaniu transformatora trakcyjnego z myślą o rozwinięciu nieinwazyjnej metody diagnostycznej w czasie rzeczywistym. Model przeznaczony do badań finalnych został rozwinięty w oparciu...
-
A method of nonlinearities of transformer no-load characteristic modelling
PublicationA way in which changes of the no-load characteristic are taken into account in the mathematical model of the transformer is presented. Changes of saturation within core of transformer are presented as a combined non-linear flux curve. Analysis of magnetization of the transformer core and simulation of no-load state for distribution transformer of 30 kVA power rating and 15.75/0.4 kV/kV (especially supplying VLV) transformation...
-
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Method of determining the residual fluxes in transformer core
PublicationThe article presents the method of calculating the residual induction in transformer columns. The method is based on measurement of the magnetic induction in selected points around the transformer core. The values of residual induction are calculated as linear combination of the results of measurement.
-
Research of leakage magnetic field in deenergized transformer
PublicationThe article deals with the issue of the numerical analysis of the magnetic field occurring around the transformer after it has been powered down. The main goal of this analysis was to examine if it is possible to identify the residual fluxes in the transformer legs based on this fields’ measurements. It was also intended to determine the type and the location of magnetic sensors. Numerical analysis of the magnetic field was performed....
-
A current-controlled FET
PublicationA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
Design of a simple modular active power electronic transformer
Publication -
Analysis of transformer state by fuzzy TOPSIS and AHP method
PublicationThe paper presents mathematical models TOPSIS and AHP methods, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine the importance of these measurements methods with this mathematical apparatus in these measurements methods in insulating state of transformers.
-
Generowanie tekstu z użyciem sieci typu Transformer
PublicationOpisano działanie wybranych modeli uczenia maszynowego znajdujących zastosowanie w przetwarzaniu języka naturalnego w szczególności wy- korzystywanych do generowania tekstu. Przedstawiono również model BERT i jego różne wersje, a także praktyczne wykorzystanie modeli typu Transformer. Przedstawiono ich działanie w aplikacji zmieniającej nastrój tekstu w sposób sekwencyjny.
-
Hysteresis modelling of a medium frequency single-phase transformer
PublicationThe article describes a feedback Preisach hysteresis model equivalent circuit implementation of a medium frequency single-phase transformer being a part of a high power and high efficiency DC-DC converter. The macroscopic models of magnetic hysteresis are introduced and the feedback Preisach model is selected for further analysis. The hysteresis model is developed for a prototype transformer and the hysteresis loops are compared...
-
Determination of Mathematical Model Parameters of a Medium Frequency Transformer
PublicationThe paper presents the results of experimental studies of the medium frequency transformer. The object of the research was a prototype of a single-phase transformer with a core made of ferrite I-core elements and windings made of Litz conductors. The research was carried out to determine the parameters of the transformer's mathematical model. The scope of the tests included determining the magnetic hysteresis loop and measuring...
-
Some remarks on the design of microstrip to coplanar line transformer.
PublicationPrzedyskutowano technikę projektowania transformatora standardu umożliwiającego współpracę linii mikropaskowej i linii koplanarnej. Jako sekcję pośrednią wykorzystano uziemiony falowód koplanarny (conductor backed coplanar waveguide). Dokonano oceny różnych profili sekcji pośredniej w oparciu o szereg symulacji elektromagnetycznych, jak i pomiarów charakterystyk transmisji wykonanych modeli transformatorów.
-
Demagnetization of the core and reduction of power transformer inrush current
PublicationW artykule przedstawiono metodę ograniczenia prądów włączania transformatora energetycznego za pomocą demagnetyzacji rdzenia magnetycznego. Jako źródło energii do demagnetyzacji w proponowanej metodzie zastosowano kondensator. Do wytworzenia pola rozmagnesowującego wykorzystano uzwojenia robocze transformatora. Przeprowadzono obliczenia magnetyzmu szczątkowego rdzenia po demagnetyzacji dla różnych wartości pojemności, napięcia...
-
PLASMA PHYSICS AND CONTROLLED FUSION
Journals -
Superconducting cavity driving with FPGA controller
Publication -
TESLA cavity driving with FPGA controller
Publication -
Fractional Order Dynamic Positioning Controller
PublicationImproving the performance of Dynamic Positioning System in such applications as station keeping, position mooring and slow speed references tracking requires improving the position and heading control precision. These goals can be achieved through the improvement of the ship control system. Fractional-order calculus is a very useful tool which extends classical, integer-order calculus and is used in contemporary modeling and control...
-
Self-Optimizing Adaptive Vibration Controller
PublicationThis paper presents a new approach to rejection of sinusoidal disturbances acting at the output of a discrete-time linear stable plant with unknown dynamics. It is assumed that the frequency of the sinusoidal disturbance is known, and that the output signal is contaminated with wideband measurement noise. The proposed controller, called SONIC (self-optimizing narrowband interference canceller), combines the coefficient fixing technique,...
-
Nonlinear Backstepping Ship Course Controller
PublicationStatek, jako obiekt sterowania charakteryzuje się nieliniową manewrową funkcją opisującą. Metoda backstepping jest jedną z metod, które mogą być wykorzystane w procesie projektowania nieliniowych układu sterowania kursem statków. Metoda została zastosowana w celu zaprojektowania dwóch konfiguracji nieliniowych regulatorów kursu.Regulatory zostały przebadane w układach regulacji kursu statku. Jedna z konfiguracji w fazie projektowania...
-
A new seismic control framework of optimal PIλDµ controller series with fuzzy PD controller including soil-structure interaction
Publication -
Design and evaluation of a base module of active power electronic transformer
Publication -
Mathematical analysis of transformer insulation state by means of composite indicator
PublicationThe paper is presenting mathematical model – composite indicator (CI), which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine importance of these measurements methods with this mathematical apparatus in these measurements methods in insulating state of transformers.
-
On the low-cost design of abbreviated multisection planar matching transformer
PublicationA numerically demanding wideband matching transformer composed of three nonuniform transmission lines (NUTLs) has been designed and optimized at a low computational cost. The computational feasibility of the design has been acquired through the exploitation of low-fidelity NUTL models in most steps of the design procedure and an implicit space mapping optimization engine, providing high accuracy results with only a handful of EM...
-
Low current transformer utilizing Co-based amorphous alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Representation of magnetic hysteresis in a circuit model of a single-phase transformer
PublicationThe paper presents a mathematical model for the hysteresis phenomenon in a multi-winding single-phase core type transformer. The set of loop differential equations was developed for K-th winding transformer model where the flux linkages of each winding includes a flux common Φ to all windings as function of magneto motive force Θ of all windings. The first purpose of this paper is to determine a hysteresis nonlinearity involved...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublicationThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
-
Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer
PublicationPower transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...
-
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Determination of leakage inductances of multi-winding and single-phase transformer
PublicationThis paper presents the method for determination of leakage inductances of single-phase and multi-winding transformer. The matrix of leakage inductances takes into account leakage self and also leakage mutual magnetic couplings. It is assumed that there is a flux common to all windings and several leakage fluxes referred to a particular winding. The flux linkages of each coil needed fo calculation of leakage inductances was computed...