displaying 1000 best results Help
Search results for: electrochemical capacitors
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 561 mA. Sample 71, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 560 mA. Sample 42, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 560 mA. Sample 42. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #3. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #1. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #8.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #8. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 560 mA. Sample 42, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 560 mA. Sample 42. Experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #2. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #2. This experiment was preceded by experiment 10.34808/av2f-rb57The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 168 mA. Sample 115, run#1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 168 mA. Sample 115. Experiment rum #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 290 mA. Sample 82, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 290 mA. Sample 82. Experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 290 mA. Sample 82, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 290 mA. Sample 82. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 168 mA. Sample 115, run#2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 168 mA. Sample 115. Experiment rum #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 290 mA. Sample 82, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 290 mA. Sample 82. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 290 mA. Sample 82, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 290 mA. Sample 82, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Chestnut-Derived Activated Carbon as a Prospective Material for Energy Storage
PublicationIn this work, we present the preparation and characterization of biomass-derived activatedcarbon (AC) in view of its application as electrode material for electrochemical capacitors. Porouscarbons are prepared by pyrolysis of chestnut seeds and subsequent activation of the obtainedbiochar. We investigate here two activation methods, namely, physical by CO2and chemical usingKOH. Morphology, structure and specific surface area (SSA)...
-
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Materials for energy storage and conversion devices 2022/2023
e-Learning CoursesElectrodes: Metals as electrodes in aqueous and non-aqueous systems, metal nanoparticles. Collectors current. 3D, 2D, 1 D carbons, carbon nanomaterials. Organic semiconductors "Synthetic metals" - p-type, n-type. Inorganic semiconductors: oxides, selenides, sulfides, others. Intercalated electrodes. Mixed conductors (MIEC). Photo-active semiconductor materials. Electrolytes. Water electrolytes in commercial products. Electroactive...
-
Corrosion studies using potentiodynamic and EIS electrochemical techniques of welded lean duplex stainless steel UNS S82441
Publication -
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes. [DOI 10.1007/s10008-008-0643-y]
PublicationObecność korozji wżerowej może być wykryta na podstawie występowania charakterystycznych przebiegów prądu płynącego między dwiema elektrodami, których wyprowadzenia są zwarte. Autorzy proponują nową metodę, która zachowuje informacje o stałej czasowej tych charakterystycznych dla procesów wżerowania przebiegów. Metoda została zastosowana do analizy szumów występujących podczas korozji stali 0H18N9 pod wpływem 1M roztworu FeCl3...
-
Correlation between destruction of the metal surface caused by pitting corrosion and intensity of the observed electrochemical noise (Invited Paper)
Publication -
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
Publication -
Comparative electrochemical analysis of the passive layer cracking process on aluminum alloys performed by means of DC and AC techniques
PublicationZbadano proces pękania warstwy pasywnej na stopach aluminium AA1050, AA5052, AA5056, oraz AA7005 w warunkach zmiennych naprężeń rozciągających i polaryzacji anodowej z wykorzystaniem techniki stałoprądowej, DEIS oraz emisji akustycznej (AE), jako metody porównawczej. Przeprowadzone badania pokazały przewagę techniki DEIS oraz emisji akustycznej nad klasyczną techniką stałoprądową. Wyznaczono dokładny moment pęknięcia warstwy pasywnej...
-
Determination of occurrence of anodic excursion peaks by dynamic electrochemical impedance spectroscopy, atomic force microscopy and cyclic voltammetry
PublicationStruktura oraz skład warstw anodowych na ołowiu najbardziej zależy od; dodatków stopowych, stężenia kwasu siarkowego oraz od zakresu potencjału. Zjawisko powstawania pików "anodic excursion peaks" od zawsze było w centrum uwagi wielu naukowców. W tej pracy zachowanie się powyższego zjawiska (AEP) zostało zbadane metodami dynamicznej elektrochemicznej spektrokopii impedancyjnej, mikroskopu sił atomowych oraz chronowoltamperometrii....
-
Fabrication of Electrochemical Biosensor Based on Titanium Dioxide Nanotubes and Silver Nanoparticles for Heat Shock Protein 70 Detection
Publication -
Determination of time dependence of coated metal electrical and electrochemical parameters during exposure using principal component analysis
PublicationThe use of the principal component analysis (PCA) permits the complex and quantitative analysis of the time dependence of electrical and electrochemical parameters of coated metal obtained by fitting impedance data. So far, changes in electrical and electrochemical parameters during exposure were analyzed independently. In this way, some of the information contained in the relationship between changes in parameters over time are...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublicationWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Enhanced electrochemical activity of boron-doped nanocarbon functionalized reticulated vitreous carbon structures for water treatment applications
PublicationAn extraordinary charge transfer kinetics and chemical stability make a boron-doped diamond (BDD) a prom- ising material for electrochemical applications including wastewater treatment. Yet, with flat geometrical sur- faces its scaling options are limited. In this study, the reticulated Vitreous Carbon (RVC) served as a substrate for boron-doped diamondized nanocarbons (BDNC) film growth resulting with complex heterogeneity carbon structures...
-
Few-Layer Black Phosphorus/Chitosan Nanocomposite Electrodes via Controlled Electrodeposition for Enhanced Electrochemical Kinetic Performance
PublicationThis study presents the preparation and characterization of few-layer black phosphorus (FLBP) chitosan electrodes by controlled electrochemical deposition of chitosan nanoparticles on FLBP-modified glassy carbon electrodes. FLBP was prepared by solvent-assisted exfoliation of bulk BP and was further modified with chitosan forming together a nanocomposite, including easy cross-linking with nanomaterials and film-forming properties....
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part II - AC methods
PublicationPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych zmiennoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Przedyskutowano stosowanie klasycznej liniowej spektroskopii impedancyjnej (EIS) z użyciem sygnałów pobudzających niskoamplitudowych, a następnie techniki zmiennoprądowe bazujące na sygnałach wysokoamplitudowych, a więc w zakresie nieliniowej charakterystyki polaryzacyjnej...
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part I - DC methods
PublicationPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych stałoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Opisano dotychczasowe sposoby oceny skuteczności ochrony katodowej na podstawie pomiarów krzywych polaryzacji i rezystancji polaryzacyjnej. Scharakteryzowano metody matematyczne i oprogramowanie opracowane do analizy komputerowej krzywych polaryzacji w celu wyznaczenia...
-
The electrochemical impedance spectroscopy studies of the anode material based on polymer and starch derived ceramic for lithium ion batteries
PublicationThe anode materials derived of preceramic polymer poly(1,2-dimethylsilazane) (PSN) and starch was study. Commercially available polysilazane (poly(1,2-dimethylsilazane (PSN 2M01 Gelest) was mixed with commercially available starch (POCH Gliwice). The ratio polymer/starch (PSN/starch) was 1/1 or 3/7. The polysialazane/starch blend was cross-linked at 230 ºC for 2 h followed by heating to the final temperature (500 ºC, 700 ºC and...
-
Electrochemical characterization of a composite comprising PEDOT/PSS and N doped TiO2 performed in aqueous and non-aqueous electrolytes
PublicationNitrogen doped titania (N-TiO2) was used as an inorganic component of composite electrodes containing poly(3,4-ethylenedioxythiophene) with poly(4-styrenesulphonate) PEDOT/PSS/N-TiO2. The composite materials were obtained by direct electrodeposition from an N-TiO2 suspension containing polyelectrolyte (NaPSS) and monomer EDOT. The electrodes were electrochemically tested in aqueous and non-aqueous electrolytes using cyclic voltammetry...
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
PublicationSurface oxidation processes play a key role in understanding electrochemical properties of boron-doped diamond (BDD) electrodes. The type of surface termination groups, which create the potential window of electrolytic water stability or hydrophobicity, influences such properties. In this study the kinetics of oxidation process under anodic polarization were studied in situ by means of Dynamic Electrochemical Impedance Spectroscopy...
-
Electrochemistry meets enzymes: Investigation of the biotransformation pathway of C-1311 based on electrochemical simulation in comparison to in vitro methods.
PublicationThe knowledge of the metabolic pathways and the biotransformation of new drugs is one of the major challenges in pharmaceutical research. It is crucial for elucidation of degradation routes of the new biologically active compounds, especially in the area of possible toxicity. Conventional in vitro drug metabolism studies are based on incubating drug candidate with e.g. hepatocytes or, most importantly, liver cell microsomes and...
-
Comparative Study of Taste Substance Sensing by Liquid Membrane Oscillator and Electrochemical Systems With All-Solid-State Electrodes
PublicationIn food industry, different types of sensors are used for characterizing and quantifying taste substances. Therefore, it is important to establish the principal advantages and disadvantages of these sensors for optimal application. In this paper, two possible systems are compared for sensing the four fundamental tastes: sour (citric acid), salty (sodium chloride), sweet (sucrose), and bitter (caffeine or quinine hydrochloride). One...
-
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
PublicationThe fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ºC. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD...
-
Unique agreement of experimental and computational infrared spectroscopy: a case study of lithium bromide solvation in an important electrochemical solvent
PublicationInfrared (IR) spectroscopy is a widely used and invaluable tool in the studies of solvation phenomena in electrolyte solutions. Using state-of-the-art chemometric analysis of a spectral series measured in a concentration-dependent manner, the spectrum of the solute-affected solvent can be extracted, providing a detailed view of the structural and energetic states of the solvent molecules influenced by the solute. Concurrently,...
-
Boron-Enhanced Growth of Micron-Scale Carbon-Based Nanowalls: A Route toward High Rates of Electrochemical Biosensing
PublicationIn this study, we have demonstrated the fabrication of novel materials called boron-doped carbon nanowalls (B:CNWs), which are characterized by remarkable electrochemical properties such as high standard rate constant (k°), low peak-to-peak separation value (ΔE) for the oxidation and reduction processes of the [Fe(CN)6]3–/4– redox system, and low surface resistivity. The B:CNW samples were deposited by the microwave plasma-assisted...
-
Influence of temperature and interactions with ligands on dissociation of dsDNA and ligand-dsDNA complexes of various types of binding : an electrochemical study.
PublicationSeveral medicinally important compounds that bind to dsDNA strands via intercalation (C-1311, C-1305, EtBr), major groove binding (Hoechst 33258) and covalent binding (cis-Pt) were examined. The obtained results suggest that both the transfer of conformation B to C and the denaturation process, for the ligand-dsDNA complexes, except for covalently bound cis-Pt, took place at higher temperatures compared to the unbound helix. Furthermore,...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublicationThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
Optical monitoring of electrochemical processes with ITO-based lossy-mode resonance optical fiber sensor applied as an electrode
PublicationIn this work we discuss the application of optical fiber sensors based on lossy-mode resonance (LMR) phenomenon for real-time optical monitoring of electrochemical processes. The sensors were obtained by a reactive high power impulse magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. The LMR effect made monitoring of changes in optical properties of both ITO and its surrounding medium...
-
Material Design and Optimisation of Electrochemical Li-Ion Storage Properties of Ternary Silicon Oxycarbide/Graphite/Tin Nanocomposites
PublicationIn this work, we present the characterization and electrochemical performance of various ternary silicon oxycarbide/graphite/tin (SiOC/C/Sn) nanocomposites as anodes for lithium-ion batteries. In binary SiOC/Sn composites, tin nanoparticles may be produced in situ via carbothermal reduction of SnO2 to metallic Sn, which consumes free carbon from the SiOC ceramic phase, thereby limiting the carbon content in the final ceramic nanocomposite....
-
Sensing the onset of epoxy coating degradation with combined Raman spectroscopy/atomic force microscopy/electrochemical impedance spectroscopy
PublicationThe paper presents the results of investigation on epoxy resin durability upon 12-week exposure to UV radiation. The aim was early determination of the onset of epoxy degradation and for this purpose an epoxy film on steel substrate systems were periodically inspected using Raman spectroscopy, atomic force microscopy and electrochemical impedance spectroscopy. The behaviour of examined polymer could be divided into three periods: immunity,...
-
Electrochemical simulation of metabolic reduction and conjugation reactions of unsymmetrical bisacridine antitumor agents, C-2028 and C-2053
PublicationElectrochemistry (EC) coupled with analysis techniques such as liquid chromatography (LC) and mass spectrometry (MS) has been developed as a powerful tool for drug metabolism simulation. The application of EC in metabolic studies is particularly favourable due to the low matrix contribution compared to in vitro or in vivo biological models. In this paper, the EC(/LC)/MS system was applied to simulate phase I metabolism of the representative...
-
Ultrasensitive electrochemical determination of the cancer biomarker protein sPD-L1 based on a BMS-8-modified gold electrode
PublicationThis work describes the modification of a gold electrode with the BMS-8 compound that interacts with the Programmed Death-Ligand 1 (PD-L1), an immune checkpoint protein. The results show that we can confirm the presence of the sPD-L1 in the concentration range of 10−18 to 10−8 M using electrochemical impedance spectroscopy (EIS) with a limit of detection (LOD) of 1.87 × 10−14 M for PD-L1 (S/N = 3.3) and at a concentration of 10−14...
-
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublicationWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
Influence of the Square Wave Voltage on Dynamical Properties of a Flat Voltammetric Electrode in the Time Domain by the Electrochemical Reversible Reaction
PublicationIn this article there is a presentation of the analysis of the polarizing voltage shape influencing dynamic properties of voltammetric electrodes when on their surface reversible reaction takes place in the time domain. The electrode polarization with linearly increasing voltage and with a square component, was analyzed. The analysis that were conducted showed that the voltammetric electrode behaves like a first order transducer....