Filters
total: 3399
-
Catalog
- Publications 1302 available results
- Journals 7 available results
- People 9 available results
- Inventions 2 available results
- Projects 1 available results
- Laboratories 3 available results
- Research Equipment 4 available results
- e-Learning Courses 40 available results
- Events 2 available results
- Open Research Data 2029 available results
displaying 1000 best results Help
Search results for: MMG
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Miniaturized uniplanar triple-band slot dipole antenna with folded radiator
PublicationA miniaturized uniplanar slot dipole for triple-frequency operation is presented. The antenna consists of a folded slot radiator with an increased number of degrees of freedom that allow for efficient size reduction. Rigorous electromagnetic (EM)-driven design optimization is applied in order to achieve the smallest possible size while maintaining acceptable levels of antenna reflection at the required operating frequencies. The...
-
Mikromocowy procesor analogowy CMOS do wstępnego przetwarzania obrazu
PublicationW artykule przedstawiono projekt i wyniki badań scalonego analogowego układu wizyjnego, który wykonuje splotowe niskopoziomowe algorytmy przetwarzania obrazu w czasie rzeczywistym. Układ prototypowy został wykonany w technologii CMOS 0,35 μm i zawiera matrycę SIMD procesorów analogowych o rozmiarze 64 x 64. Wymiary topografii matrycy wynoszą 2,2 mm x 2,2 mm, co daje gęstość 877 procesorów na mm2. Matryca pobiera moc mniejszą niż...
-
Room temperature solvent extraction for simple and fast determination of total concentration of Ca, Cu, Fe, Mg, Mn, and Zn in bee pollen by FAAS along with assessment of the bioaccessible fraction of these elements using in vitro gastrointestinal digestion
Publication -
Mikromocowy procesor analogowy CMOS do wstępnego przetwarzania obrazu
PublicationW artykule przedstawiono scalony analogowy układ wizyjny (ang. vision chip), który wykonuje splotowe niskopoziomowe algorytmy przetwarzania obrazów w czasie rzeczywistym. Układ prototypowy został wykonany w technologii CMOS 0,35 μm i zawiera matrycę SIMD procesorów analogowych o rozmiarze 64 x 64. Wymiary topografii matrycy wynoszą 2,2 mm x 2,2 mm, co daje gęstość 877 procesorów na mm2. Matryca pobiera moc mniejszą niż 0,4 μW (poniżej...
-
Wear Resistance Enhancement of Al6061 Alloy Surface Layer by Laser Dispersed Carbide Powders
PublicationIn this paper, results of the experimental study on improving wear resistance in sliding friction of Al-based alloy are presented. The technique used involves the formation of a metal matrix composite (MMC) in the alloy surface layer by laser dispersion of carbide powders such as WC, TiC and SiC. For WC and TiC MMC surface coatings fabricated under conditions typical for most of the technologically relevant solid-state lasers (wavelength...
-
Regulation of replication of λ phage and λ plasmid DNAs at low temperature
Publication -
Cloning and characterization of the dnaK heat shock operon of the marine bacterium Vibrio harveyi
Publication -
100– lecie urodzin profesora Romualda Kolmana 1922-2016, patrona Konkursu IKAR JAKOŚCI. Kamienie milowe w dorobku twórcy kwalitologii w Polsce
Publication17 czerwca 2022 roku minęła 100. rocznica urodzin śp. profesora dr. hab. inż. Romualda Kolmana, jednego z najczęściej przywoływanych twórców i krzewicieli Polskiej Szkoły Jakości. Jako podwładny i doktorant profesora w ostatnim, przypadającym na lata 90. XX wieku okresie jego pracy na Wydziale Mechanicznym Technologicznym w Politechnice Gdańskiej, miałem tę możliwość i szczęście, że mogłem zapoznać się z praktycznie całym dorobkiem...
-
A novel microstrip dual-layer rat-race coupler with compact size and enhanced bandwidth
PublicationMicrowave hybrid couplers are crucial components of mixers, phase shifters, amplifiers and other high-frequency systems. Conventional couplers are characterized by large size which limits their usefulness in modern applications. In this work, a novel compact rat-race coupler with enhanced bandwidth has been proposed. The structure consists of six compact microstrip resonant cells. It is implemented on two separate layers which permits...
-
APPLICATION POSSIBILITIES OF THE S960 STEEL IN UNDERWATER WELDED STRUCTURES
PublicationIn this paper, the application possibilities of the ultra-high strength (UHSS). Domex 960 steel in the underwater welded structures are analyzed. In the research, the investigated material has been tested in bead-on-plate wet welding conditions with the usage of different heat input values, namely 0.63 kJ/mm, 0.72 kJ/mm and 0.93 kJ/mm. Specimens were performed by the manual metal arc (MMA) welding method with the usage of rutile...
-
Dwukanałowy aparat EMG MyoPlus 2
Research EquipmentBadania EMG, ćwiczenia biofeedback oraz elektrostymulacja
-
Granulometric analysis to etimate influence of anionic surfactrant on activated sludge structure
PublicationThe work concerns the evaluation of the possibility of using laser diffraction analyzer to determine changes in the distribution of sludge floc size in the presence of anionic surfactant. As a model of surfactant linear alkylbenzyne sulphonate (LAS) was used. The granulometric analysis showed that the pure activated sludge was composed of particles with a size of 0,001 to 2 mm. The largest and fastest changes in the distribution...
-
Design and Optimization of Metamaterial-Based 5G Millimeter Wave Antenna for Gain Enhancement
PublicationIn this brief, a low profile, broadband, high-gain antenna array based on optimized metamaterials (MMs) with dual-beam radiation is reported for 5G millimeters wave (mm-wave) applications. The design is a simple bow tie operating at a 5G band of 28 GHz. It consists of two bow ties with substrate integrated waveguide (SIW)-based power splitter. A broad impedance bandwidth of 26.3−29.8 GHz is obtained by appropriately combining the...
-
Characteristics of La 0.8 Sr 0.2 Ga 0.8 Mg 0.2 O 3-δ -supported micro-tubular solid oxide fuel cells with LaCo 0.4 Ni 0.6-x Cu x O 3-δ cathodes
PublicationIn this study, micro-tubular solid oxide fuel cells (T-SOFCs) with extruded La0.8Sr0.2Ga0.8Mg0.2O3-δ (LSGM) electrolyte as the mechanical support and LaCo0.4Ni0.6O3-δ (LCNO) or LaCo0.4Ni0.4Cu0.2O3-δ (LCNCO) as cathodes were prepared and characterized. Partial substitution of Cu for the Ni-ion positions in the LCNO lattices was found to significantly enhance the densification and accelerate the grain growth. The porosity-corrected...
-
Novel structure and design of compact UWB slot antenna
PublicationIn this paper, a novel structure of a compact UWB slot antenna is presented along with a simulation-driven design optimization algorithm for adjusting geometry parameters of the device. Our primary objective is to obtain small footprint of the structure while maintaining its acceptable electrical performance. It is achieved by introducing sufficiently large number of geometry degrees of freedom, including increased number of parameterized...
-
Ellipsometric monitoring during the polarization studies of Mg corrosion in alkaline environment
Open Research DataThe dataset contains the ellipsometric results from the Mg polarization studies aiming at understanding the Mg(OH)2 passive layer formation mechanism and conditions. The single-wavelength ellipsometer ELX-02C from Dr Riss GmbH was utilized, operating He-Ne laser at 632.8 nm. The polarization conditions for the experiment are depicted in the related...
-
Konsultacje (MMM, Robotyka) ACR sem. 4
e-Learning CoursesMateriały do zajęć: Metody Modelowania Matematycznego, Podstawy Robotyki
-
Sprawozdanie naukowe z badania nośności pala CFA Nr T13 mm metodą próbnego obciążenia statycznego z pomiarem rozkładu siły osiowej wzdłuż trzonu na terenie budowy Inteligentnego Centrum Logistycznego w Pustyni k. Dębicy
PublicationOpracowanie wyników badania nośności pala wierconego świdrem ciągłym CFA ∅630 mm, nr T13, wykonanego na terenie budowy Inteligentnego Centrum Logistycznego dla Nutrifarm Sp. z o.o., zlokalizowanego w miejscowości Pustynia k. Dębicy. Badanie pala wykonano metodą próbnego obciążenia statycznego z pomiarem rozkładu siły osiowej wzdłuż trzonu pala, zrealizowanym za pomocą ekstensometrów strunowych.
-
Rozdrobione odpady polimerowe- nowy problem i świadek historii wpływu człowieka na najnowsze dzieje ziemi.
PublicationSyntetyczne polimery są nieodłącznym towarzyszem współczesnego człowieka i dowodem jego działalności obecnym w osadach, szczególnie od połowy XX wieku. Przeciętny konsument wprowadza dziennie do środowiska około 2,4 mg mikroplastiku. Terminem "mikroplastik" określa się odpady z tworzyw sztucznych, ktorych wielkość nie przekracza 5 mm.
-
Ocena nośności pali wierconych fi 880 mm wykonanych pod posadowienie podpór wiaduktu na podstawie próbnych obciążeń statycznych pali. Budowa wiaduktu nad torami PKP relacji Gdańsk - Tczew (E-65) w km 310+773.
PublicationWykonano ocenę nośności fundamentów palowych posadowionych na palach wierconych o średnicy 880 mm na podstawie badań statycznych tych pali.
-
EH36 steel for shipbuilding (plate thicnkness 30 mm) - 3D fracture scan
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
Opinia naukowo-techniczna dotycząca przyczyn obniżonej nośności pali CFA 800 mm wykonanych pod posadowienie podpory P10 wiaduktu drogowego nad linią kolejową w Cieplewie k. Pruszcza Gdańskiego wraz z propozycją zapewnienia nośności fundamentu podpory
PublicationPrzeprowadzono analizę wyniku próbnego obciążenia pala CFA pod posadowienie przyczółka wiaduktu. Przeanalizowano budowę podłoża gruntowego na podstawie dokumentacji archiwalnych i na podstawie własnych badań metodą CPT. Określono przyczyny obniżonej nośności wykonanych pali. Zaproponowano sposób zapewnienia wymaganej nośności fundamentu przyczółka.
-
Manifestation of Intermolecular Interactions in the IR Spectra of 2- and 4-Methylmethcathinones Hydrochlorides: DFT Study and Hirshfeld Surfaces Analysis
PublicationThis paper reports a Hirshfeld surfaces analysis of crystalline 2- and 4-methylmethcathinone (2-MMC and 4-MMC) hydrochlorides to analyze NH∙Cl and CH∙∙∙Cl intermolecular interactions and approve the formation of the NН2+–Cl– salt fragment in both 2-MMC∙HCl and 4-MMC∙HCl crystals. Two isomeric dimers were separated from the corresponding crystal packing to model IR spectra of the crystalline 2-MMC∙HCl...
-
Design and Optimization of Metamaterial-based Highly-isolated MIMO Antenna with High Gain and Beam Tilting Ability for 5G Millimeter Wave Applications
PublicationThis paper presents a wideband multiple-input multiple-output (MIMO) antenna with high gain and isolation, as well as beam tilting capability, for 5G millimeter wave (MMW) applications. A single bow-tie antenna fed by a substrate-integrated waveguide (SIW) is proposed to cover the 28 GHz band (26.5–29.5 GHz) with a maximum gain of 6.35 dB. To enhance the gain, H-shaped metamaterial (MM)-based components are incorporated into the...
-
Thermal treatment of montmorillonite modified with Cd[SC(NH2)2]42+ from two polymorphic salts
PublicationMontmorillonite(MMT)/CdS nanocomposites can be obtained using simple ionic exchange between Na(I)-MMT and Cd[SC(NH2)2]42+∙2NO3. The resulting products may be annealed to give (MMT)/CdS nanocomposites as it was proved by XRD analysis.
-
Self-organized multilayered graphene-boron doped diamond hybrid nanowalls for high performance electron emission devices
PublicationCarbon nanomaterials like nanotubes, nanoflakes/nanowalls and graphene have been used as electron sources due to their superior field electron emission (FEE) characteristics. Nevertheless, these materials show poor stability and a short lifetime, preventing them from being used in practical device applications. The intention of this study was to find an innovative nanomaterial, possessing both high robustness and reliable FEE behavior....
-
Chemical and biological characterization of Ocimum basilicum L. phenolic extract and essential oil derived through ultrasound and microwave-assisted extraction techniques
PublicationPlant-derived bioactive molecules are increasingly utilized in food processing as natural additives, driven by a growing interest in healthier lifestyles. This trend has spurred industries to reformulate products to meet the demands of health-conscious consumers. This study investigates the phenolic extract and essential oil of O. basilicum L. obtained via ultrasound-assisted extraction and microwave-assisted extraction, respectively. Characterization...
-
Frequency Response Functions for Sandvik CoroBore 825 XL boring tool, 733 mm
Open Research DataFrequency Response Functions (FRF) obtained for Sandvik CoroBore® 825 XL mounted at WHN 13-15 TOS VARNSDORF CNC machine at the minimum extension of the spindle adaptor. Tool set to bore a hole with a diameter 733mm
-
Optymalizacja transferu energii w mikrofalowym module plazmowym o strukturze współosiowej zasilanym falowodem WR 340
PublicationMikrofalowy moduł plazmowy (MMP) służy do produkcji wodoru poprzez reforming węglowodorów. W pracy przedstawiono wyniki optymalizacji transferu energii w MMP o strukturze współosiowej zasilanym falowodem WR 340. W omawianym MMP wyładowanie mikrofalowe powstaje pod ciśnieniem atmosferycznym, a częstotliwość pracy wynosi 2,45GHz. Optymalizacja została przeprowadzona numerycznie za pomocą programu Comsol. Kryteria optymalizacji zostały...
-
Analiza numeryczna mikrofalowego modułu plazmowego do produkcji wodoru
PublicationMikrofalowy moduł plazmowy (MMP) służy do produkcji wodoru poprzez reforming węglowodorów. W pracy przedstawiono wyniki optymalizacji transferu energii w MMP o strukturze współosiowej zasilanym falowodem WR 340. W omawianym MMP wyładowanie mikrofalowe powstaje pod ciśnieniem atmosferycznym, a częstotliwość pracy wynosi 2,45 GHz. Wyniki analizy numerycznej pokazują,że dla wybranej konfiguracji MMP minimalny stosunek mocy fali...
-
A novel dual-band rectifier circuit with enhanced bandwidth for RF energy harvesting applications
PublicationIn recent years, a rapid development of low-power sensor networks, enabling machine-to-machine communication in applications such as environmental monitoring, has been observed. Contemporary sensors are normally supplied by an external power source, typically in a form of a battery, which limits their lifespan and increases the maintenance costs. This problem can be addressed by harvesting and converting ambient RF energy into...
-
Evaluation of antimicrobial activities of powdered cuttlebone against Klebsiella oxytoca, Staphylococcus aureus, and Aspergillus flavus
PublicationBackground: The presence of medicines in the environment is considered as a serious threat to the human health. The entrance of these substances into the water sources causes soil pollution, which eventually leads to the environmental pollution and it creates some problems for the public health. Also, increasing antibiotic resistant bacteria has attracted the attention of researchers to the use of natural resources such as marine...
-
Recombinant !ermostable AP Exonuclease from Thermoanaerobacter tengcongensis: Cloning, Expression, Purification, Properties and PCR Application
PublicationApurinic/apyrimidinic (AP) sites in DNA are considered to be highly mutagenic and must be corrected to preserve genetic integrity, especially at high temperatures. !e gene encoding a homologue of AP exonuclease was cloned from the thermophilic anaerobic bacterium Thermoanaerobacter tengcongensis and transformed into Escherichia coli. The protein product showed high identity (80%) to human Ape1 nuclease, whereas to E. coli exonuclease...