Filters
total: 1735
displaying 1000 best results Help
Search results for: ti13nb13zr alloy
-
X-ray Photoelectron Spectroscopy studies of various carboxylic acids adsorption on aluminium alloys in alkaline media
Open Research DataThis dataset contains the results of high-resolution XPS studies obtained during evaluation of high corrosion inhibition efficiency of various carboxylic acids towards aluminium alloy 5754 in bicarbonate buffer pH=11.
-
Wpływ nadtapiania laserowego w warunkach kriogenicznych na strukturę warstwy wierzchniej stopu Ti-6Al-4V = Effect of laser melting at cryogenic conditions on structure of the surface layer of the Ti-6Al-4V alloy
PublicationWykonano nadtapianie laserowe stopu Ti-6Al-4V zanurzonego w środowisku ciekłego azotu. Badania mikroskopowe wykazały znaczący wpływ parametrów nadtapiania na grubość, mikrostrukturę i mikrotwardośc warstwy wierzchniej.
-
Photocatalytically Active TiO2/Ag2O Nanotube Arrays Interlaced with Silver Nanoparticles Obtained from the One-Step Anodic Oxidation of Ti–Ag Alloys
PublicationThe development of a photocatalyst with remarkable activity to degrade pollutants in aqueous and gas phase requires visible lightresponsive stable materials, easily organized in the form of a thin layer (to exclude the highly expensive separation step). In this work, we present a one-step strategy for synthesizing material in the form of a self-organized TiO2/Ag2O nanotube (NT) array interlaced with silver nanoparticles (as in a...
-
Te Zhong Zhu Zao Ji You Se He Jin/Journal of Special Casting & Nonferrous Alloys
Journals -
Electrostatic self-assembly approach in the deposition of bio-functional chitosan-based layers enriched with caffeic acid on Ti-6Al-7Nb alloys by alternate immersion
Publication -
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublicationNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
High-temperature Corrosion of ~ 30 Pct Porous FeCr Stainless Steels in Air: Long-Term Evaluation Up to Breakaway
PublicationIn this work, a long-term (up to 6000 hours) corrosion evaluation of three porous (~ 30 pct of initial porosity) ferritic iron-chromium alloys with different Cr contents (20, 22, and 27 wt pct of Cr) was carried out at 600 C, 700 C, 800 C, and 900 C in air. Mass gain measurements and SEM analyses revealed that at temperatures above 600 C, all alloys exhibit breakaway corrosion, whereas at 600 C, none of the alloys were heavily...
-
Localized impedance measurements of AA2024 and AA2024-T3 performed by means of AFM in contact mode
PublicationPurpose: The purpose of this paper is to present the results of an atomic force microscopy (AFM) based approach to local impedance spectroscopy (LIS) measurement performed on AA2024 and AA2024-T3 aluminium alloys. Design/methodology/approach: AFM-LIS measurements were performed ex-situ without the electrolyte environment, so in fact the electrical not electrochemical impedance was obtained. Findings: Relative local impedance values...
-
Joanna Sypniewska mgr inż.
PeoplePhD student in the field of materials engineering at Gdansk University of Technology. Working on laser surface modification of titanium alloys for biomedical applications
-
Characteristics of silver-dopped carbon nanotube coating destined for medical applications
PublicationCarbon nanotubes are materials demonstrating outstanding mechanical, chemical, and physical properties and are considered coatings of titanium implants. The present research is aimed to characterize the microstructure and properties of the multi-wall carbon nanotubes (MWCNTs) layer decorated with silver nanoparticles (Ag NPs) on the Ti13Nb13Zr alloy destined for long-term implants. The electrophoretic deposition of coatings...
-
Powłoka hydroksyapatytowa na nanorurkowej warstwie tlenkowej na stopie tytanu
PublicationPrzedstawiono sposób nakładania powłok hydroksyapatytowych na porowaty stop tytanu Ti13Nb13Zr za pomocą osadzania biomimetycznego poprzez zanurzenie materiału w przesyconym symulowanym płynie fizjologicznym. Powłoka hydroksyapatytowa została osadzona na nanorurkową warstwę tlenkową, otrzymaną w wyniku utleniania elektrochemicznego w roztworze zawierającym jony fluorkowe.
-
Wnikanie wodoru z paliwa i oleju do stali stopowych 26h2mf i 34hnm oraz jego oddziaływanie z defektami struktury = The hydrogen entry from fuel and oil to the 26h2mf and 34hnm alloy steels, and its interaction with structure defects
PublicationWykonano badania skłonności do korozji naprężeniowej przy rozciąganiu próbek ze stałą małą prędkością 10-6s-1, przy obciążeniu cyklicznie zmiennym w środowisku gorącego paliwa kotłowego i gliceryny oraz badania absorpcji wodoru dla stali stopowych 26H2MF i 34HNM w paliwie kotłowym, przepracowanym oleju mineralnym oraz glicerynie jako środowisku referencyjnym. Wykazano największą wrażliwość stali przy obciążeniach zmiennych oraz...
-
Absorbciâ vodoroda i povedenie vodoroda v slaâh titanovyh silavov s modificirovannoj poverhnost''û = Hydrogen absorption and hydrogen effects in the modified surface layers of Ti alloys
PublicationW pracy przedstawiono rezultaty badań absorpcji wodoru w stopach tytanu ze zmodyfikowaną za pomocą metod multipleksowych powierzchnią. W wyniku badań stwierdzono, iż po nadtapianiu laserowym w warunkach kriogenicznych, stopy tytanu wykazuja najwyższą zdolność absorpcji wodoru w wytworzonej warstwie wierzchniej.
-
Tytanowa międzywarstwa w łącznikach do spawania Al i stopów AlMg ze stalą=Titanium interlayer in transition joints to welding aluminium and aluminium alloys AlMg with steel
PublicationPrzedstawiono idee stosowania łączników i ich wytwarzanie oraz własności i niedostatki obecnie stosowanych łączników. Zaprezentowano wyniki prób technologicznych wytwarzania oraz wyniki badań mechanicznych i strukturalnych trójwarstwowego łącznika stal-tytan-aluminium.
-
COMPARISON OF THE ABRASION RESISTANCE OF THE SELECTED BIOMATERIALS FOR FRICTION COMPONENTS IN ORTHOPEDIC ENDOPROSTHESES
PublicationRosnące z każdym rokiem zapotrzebowanie na endoprotezy stawów ortopedycznych przy jednoczesnym dążeniu do zwiększenia ich trwałości i wyeliminowania negatywnych skutków ubocznych produktów zużycia, które mogą wywoływać proces zapalny w tkankach determinuje potrzebę poszukiwania nowych biomateriałów, bądź metody modyfikacji ich powierzchni. Nadrzędnym celem prowadzonych przez nas badań było oszacowanie intensywności zużycia ściernego...
-
Imaging of the effects of pitting corrosion with the use of AFM
Open Research DataPitting corrosion is a local attack on a metal surface, limited to a point or small area, which appears as a hole. Pitting corrosion is one of the most harmful forms of corrosion due to the fact that it is associated with small, difficult to detect damage, that can even lead to perforation of the structure. A single pit may range in size from micrometers...
-
Zgrzewanie tarciowe z mieszaniem wewnętrznym zgrzeiny stopów aluminium AW7075-T651 i AW6082-T6 = Friction stir welding of aluminium alloys AW-7075-t651 and AW-6082-t6
PublicationW pracy przedstawione są wyniki badań nad złączami doczołowymi zgrzewanymi przy użyciu technologii Friction Stir Welding (FSW), wykonanymi z wysokowytrzymałego stopu Al-Zn (AW-7075-T651) oraz stopu Al-Mg2Si (AW-6082-T6) o wysokiej odporności na korozję. Stop AW-7075-T651 okazał się bardziej podatny na obniżenie własności mechanicznych w odniesieniu do materiału rodzimego. Złącza ze stopu AW-6082-T6 wykazały się lepszą plastycznością....
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Reliable method of assessing fracture properties of asymmetric bonded joints
PublicationTwo methods of assessing fracture properties of adhesive joints were studied. Two wedge tests: with continuous deflection and with force measurements were compared. Asymmetric geometry of the bonded joint was considered, i.e. two different plates of aluminium alloys: Al-Cu and Al-Mg, were bonded with epoxy DGEBA adhesive. The analytical model is shown to estimate the values of fracture properties: crack position and critical fracture...
-
Vascular stents - materials and manufacturing technologies
PublicationThe objective of this article is to present materials and technology for the manufacture of vascular stents with appropriate design requirements. The use of the right material is very important in implantology. A biomaterial introduced into the circulatory system must be biocompatible and hemocompatible. At the same time, it should not initiate toxic, mutagenic, or immunological reactions. Currently, 316L stainless steel (316L...
-
Preparation to ball on disk test Initial contact stress evaluation
Open Research DataEvaluation of initial contact stress in tests on wear of Al6061 alloy in ball on disk tribological testing. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
TiO 2 Co x O y composite nanotube arrays via one step electrochemical anodization for visible light–induced photocatalytic reaction
PublicationTiO2CoxOy (x = 1, y = 1 or x = 3, y = 4) composite photocatalysts have been synthesized via one step anodic anodization of TiCo alloys. The effects of the cobalt content in the alloy (5, 10 and 15 wt%), water content (2, 5 and 10%) in the electrolyte solution, and applied voltage (30, 40 and 50 V) during the anodization process on the morphology and surface properties. Additionally, the dependence of cobalt content in the nanotubes...
-
Technologia otrzymywania bioaktywnych powłok na porowatym nietoksycznym stopie tytanu Ti13Nb13Zr
ProjectsProject realized in Faculty of Mechanical Engineering according to UMO-2012/05/N/ST8/02909 agreement from 2013-01-25
-
Research on Linear Actuators for Active Foil Bearings
PublicationActive foil bearings are a kind of gas foil bearing. They contain actuators which allow for modification of the bearing sleeve size and the shape of the lubrication gap. Rotor vibrations can be actively controlled by these changes. It is possible, among other things, to reduce the starting torque, control the vibration amplitude at different speeds and improve operational safety. Prototypes of active foil bearings are being developed...
-
Complementarity between entanglement-assisted and quantum distributed random access code
PublicationCollaborative communication tasks such as random access codes (RACs) employing quantum resources have manifested great potential in enhancing information processing capabilities beyond the classical limitations. The two quantum variants of RACs, namely, quantum random access code (QRAC) and the entanglement-assisted random access code (EARAC), have demonstrated equal prowess for a number of tasks. However, there do exist specific...
-
Effect of TiO2 Concentration on Microstructure and Properties of Composite Cu–Sn–TiO2 Coatings Obtained by Electrodeposition
PublicationIn this work, Cu–Sn–TiO2 composite coatings were electrochemically obtained from a sulfate bath containing 0–10 g/L of TiO2 nanoparticles. The effect of TiO2 particles on kinetics of cathodic electrodeposition has been studied by linear sweep voltammetry and chronopotentiometry. As compared to the Cu–Sn alloy, the Cu–Sn–TiO2 composite coatings show rougher surfaces with TiO2 agglomerates embedded in the metal matrix. The highest...
-
Grant Monbusho Rządu Japońskiego Grant Monbusho Rządu Japońskiego, Application of shape memory alloy to improve the seismic performance of bridges
ProjectsProject realized in The University od Tokyo according to . agreement from 1997-05-01
-
Porównanie zużycia ściernego wybranych biomateriałów przeznaczonych na komponenty ślizgowe endoprotez stawu biodrowego
PublicationNadrzędnym wymaganiem stawianym nowoczesnym endoprotezom jest wysoka trwałość współpracujących elementów, przekładająca się na optymalnie długi czas funkcjonowania w organizmie ludzkim. Niestety trwałość obecnie stosowanych endoprotez stawu biodrowego ograniczona jest procesami zużycia tribologicznego, zachodzącymi w podstawowym układzie ruchowym pomiędzy głową, a panewką zaimplantowanej endoprotezy stawu biodrowego [Pawlak i in....
-
Increased Certification of Semi-device Independent Random Numbers using Many Inputs and More Postprocessing
PublicationQuantum communication with systems of dimension larger than two provides advantages in information processing tasks. Examples include higher rates of key distribution and random number generation. The main disadvantage of using such multi-dimensional quantum systems is the increased complexity of the experimental setup. Here, we analyze a not-so-obvious problem: the relation between randomness certification and computational requirements...
-
Experimental test of nonclassicality with arbitrarily low detection efficiency
PublicationWe theoretically introduce and experimentally demonstrate the realization of a nonclassicality test that allows for arbitrarily low detection efficiency without invoking an extra assumption of independence of the devices. Our test and its implementation is set in a prepare-and-measure scenario with an upper limit on the classical communication capacity of the channel through which the systems are communicated. The essence for our...
-
Experimental tuning of AuAg nanoalloy plasmon resonances assisted by machine learning method
PublicationPlasmonic nanostructures based on AuAg nanoalloys were fabricated by thermal annealing of metallic films in an argon atmosphere. The nanoalloys were chosen because they can extend the wavelength range in which plasmon resonance occurs and thus allow the design of plasmonic platforms with the desired parameters. The influence of initial fabrication parameters and experimental conditions on the formation of nanostructures was investigated....
-
Wytwarzanie, budowa i właściwości warstw tlenkowych uzyskanych na stopach tytanu do zastosowań biomedycznych
PublicationPraca koncentruje się na zagadnieniach związanych z metodami modyfikacji warstwy wierzchniej stopów tytanu, z ukierunkowaniem na stop tytanu Ti13Nb13Zr, którego skład chemiczny stanowią pierwiastki obojętne dla organizmu żywego, a moduł Yong’a jest zbliżony do kości. Odpowiednia modyfikacja warstwy wierzchniej umożliwia przyspieszenie procesów łączenia żywej tkanki z wprowadzonym elementem i powoduje wydłużenie czasu użytkowania...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Effect of microstructure on mechanical properties of BA1055 bronze castings
PublicationThe article presents research results performed on aluminum bronze CuAl10Fe5Ni5 (BA1032) castings used for marine propellers. Metallographic studies were made on light microscope and a scanning electron microscope to assess quantitatively and qualitatively the alloy microstructure. It has been shown that the shape, size and distribution of the iron-rich phase precipitates in bronze microstructure significantly affect its mechanical...
-
Insightful studies of AuCu nanostructures deposited on Ti platform: Effect of rapid thermal annealing on photoelectrochemical activity supported by synchrotron radiation studies
PublicationIn this work, we present the influence of annealing atmospheres during rapid thermal annealing (40◦C/s) on nanostructured Ti platforms modified by 10 nm layer of AuCu alloy obtained via magnetron sputtering. The AuCu/Ti platform annealed under hydrogen atmosphere exhibits the best photoelectrochemical activity under visible light, i.e. 27 times higher photocurrent than for pure Ti dimpled platform, and the lowest reflectance with minimum...
-
Ball on disk test AL(rf.)-Al2O3-r25
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 not treated (reference).
-
Ball on disk test AL(rf.)-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 not treated (reference).
-
The effect of preliminary creep-strain on material behavior under LCF tension/compression and pure torsion regimes
PublicationThis paper presents the results of experimental tests of monotonic tension and torsion, creep-rupture and preliminary creep at 200C and 300C, as well as low-cycle fatigue of 2024 T3511 aluminum alloy. The fatigue process was conducted at room temperature for uniaxial tension/compression and torsion. The as-received material and pre-deformed material were also investigated during creep at elevated temperature. Basic monotonic,...
-
Ball on disk test AT4_11-Al2O3-r25
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT4_11).
-
Ball on disk test AT3_21-Al2O3-r25
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT3_21).
-
Ball on disk test AW4_1-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 WC powder injected (AW4_1).
-
Ball on disk test AT4_4-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT4_4).
-
Ball on disk test AW4_11-Al2O3-r25
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 WC powder injected (AW4_11).
-
Ball on disk test AT4_1-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT4_1).
-
Ball on disk test AT4_41-Al2O3-r25
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 25 mm. Disk material: Al6061 TiN powder injected (AT4_41).
-
Ball on disk test AT3_2-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 TiN powder injected (AT3_2).
-
Ball on disk test AW4_4-Al2O3-r15
Open Research DataHard particle reinforced Al6061 alloy testing. Laser remelting and kinetic injection of particulate material. Ball on disc tribological test. Ball material: Al2O3. Ball diameter: 5 mm. Sliding path radius: 15 mm. Disk material: Al6061 WC powder injected (AW4_4).