Search results for: NUISANCE TRIPPING
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublicationThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
APPLICATION OF ULTRAFAST GAS CHROMATOGRAPHY TO RECOGNIZE ODOR NUISANCE
PublicationPotentialities of ultrafast gas chromatography applied to periodical monitoring of odor nuisance originating from a municipal landfill have been examined. The results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during winter and summer season have been presented. The investigation was performed using ultrafast gas chromatography of Fast/Flash GC type HERACLES II by Alpha...
-
On weakly dispersive multiple-trapping transport
PublicationPodano przybliżone rozwiązania równań transportu nośników ładunku dla modelu wielokrotnego pułapkowania, odnoszących się do metody czasu przelotu - przy założeniu, że większość nośników znajduje się w stanie termicznej quasi równowagi. Otrzymane rozwiązania zweryfikowano przy pomocy obliczeń metodą Monte Carlo dla wykładniczego i gaussowskiego rozkładu pułapek. Zaproponowano nową metodę wyznaczania profilu energetycznego pułapek...
-
Vision guided robot gripping systems
PublicationW rozdziale omawia się robotycki system wykorzystujący kamery streo. System taki zastępuje pracę człowieka przy przenoszeniu obiektów wielkowymiarowych (teoretycznie nieograniczonych) w przestrzeni trójwymiarowej. W rozważaniach uwzględniono pinholową kamerę (bezsoczewkową z bardzo małą aperturą/otworem) oraz prosty model zniekształcenia soczewkowego. Podano wartości poszczególnych parametrów. Zastosowano dwie konwencje notacyjne...
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublicationLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
Tripping of F-type RCDs for high-frequency residual currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
The effect of current delay angle on tripping of residual current devices
PublicationPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Odour nuisance assessment of the food industry wastewater treatment plant
Publication -
Monitoring of Odour Nuisance from Landfill Using Electronic Nose
PublicationThe paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples...
-
The impact of shipping 4.0 on controlling shipping accidents: A systematic literature review
PublicationMaritime shipping, with a significant role in global trade, confronts various accidents leading to loss of lives, properties, and the environment. Shipping 4.0 technologies are scaling up to address this problem by employing real-time data-driven technologies, including cyber-physical systems, advanced tracking and tracing, intelligent systems, and big data analytics. Despite growing attention, there is a general lack of clarity...
-
Open tubular trapping - present and future prospects
PublicationOtwarte pułapki kapilarne posiadają pewne unikalne właściwości, które ułatwiają ich zastosowanie zarówno w analizie próbek gazowych jak i wodnych - na przykład niskie opory przepływu umożliwiają ich bezpośrednie połączenie z większością technik rozdzielania chromatograficznego. W pracy opisano etapu rozwoju OTT na przestrzeni ostatnich kilkunastu lat, ze szczególnym uwzględnieniem aspektów technologii ich wytwarzania oraz sposobów...
-
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
A case study of odour nuisance evaluation in the context of integrated urban planning
PublicationOdour nuisance poses a serious problem in many urban areas, yet its evaluation and mitigation is often omitted in the urban planning process. By identifying its range and spatio-temporal variations, it could be taken into consideration by planners in urban development strategies and land use decisions. The aim of the study was to present the application of odour evaluation techniques in the improvement of the quality of life in...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Comparison of residual current devices tripping characteristics for selected residual current waveforms
PublicationZgodnie z normami międzynarodowymi, w instalacjach o zwiększonym ryzyku porażenia prądem elektrycznym należy stosować wyłączniki różnicowoprądowe wysokoczułe. Dla zapewnienia skutecznej ochrony przeciwporażeniowej zainstalowany wyłącznik różnicowoprądowy powinien prawidłowo wykrywać określony kształt prądu różnicowego. W artykule przedstawiono charakterystyki działania wyłączników różnicowoprądowych przy wybranych przebiegach odkształconego...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Air trapping problem during infiltration on the large areas
PublicationThe process of flow modeling in unsaturated porous medium is often found in many fields of sciences: geology, fluid mechanics, thermodynamics, microbiology or chemistry. Problem is relatively complicated due to complexity of the system which contains three phases: water, air and soil skeleton. The flow of water in such a medium can be described using two-phase (2PH) flow formulation, which accounts the inflow of air and water phases,...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
Scintillation light trapping and radiation damage in CeF/sub 3/
Publication -
Excitation energy transport and trapping in concentrated solid solution of flavomononucleotide
PublicationW pracy analizowano bez promienisty transfer energii w stężonych stałych roztworach (folie polimerowe) FMN. W w/w roztworach występują świecące dimery FMN. Pokazano, że jedynie uwzględnienie powrotnego transferu energii pozwala zadowalająco wyjaśnić mechanizm przenoszenia energii w badanych układach.
-
Excitation energy transport and trapping in concentrated solid solutions offlavomononucleotide.
PublicationPraca dotyczy właściwości transportu i pułapkowania energii wzbudzenia w układzie monomer dimer dla flawomononukleotydu rozpuszczonego w filmach alkoholu poliwinylowego. Pokazano, że w tym przypadku wydajność kwantowa i depolaryzacja nie dają się opisać w ramach teorii nie uwzględniającej powrotnego przekazywania energii i że znacznie lepsza zgodność uzyskanych wyników doświadczalnych zachodzi z teorią, w której fluoryzujące...
-
Perception of 'Green Shipping' in the contemporary conditions
Publication -
Analysis of the application of selected physico-chemical methods in eliminating odor nuisance of municipal facilities
Publication -
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublicationThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Surface and Trapping Energies as Predictors for the Photocatalytic Degradation of Aromatic Organic Pollutants
PublicationIn this study, anatase samples enclosed by the majority of three different crystal facets {0 0 1}, {1 0 0}, and {1 0 1} were successfully synthesized. These materials were further studied toward photocatalytic degradation of phenol and toluene as model organic pollutants in water and gas phases. The obtained results were analyzed concerning their surface structure, reaction type, and surface development. Moreover, the regression...
-
Application of bismuth film electrode for determination of heavy metals by stripping voltammetry
PublicationWhen Wang's research group introduced a new type of a working electrode: bismuth film plated electrode (BiFE), it has started attracting increasing attention in the field of electrochemical stripping analysis. These electrodes are shown to be very attractive alternative to common mercury-based electrodes, which are predominantly used in analysis of trace heavy metals.For the determination of heavy metals (Zn, Cd, Pb, Cu) used square...
-
Osmotic membrane distillation with continuous regeneration of stripping solution by natural evaporation
Publication -
Soliton trapping and orthogonal Raman scattering in a birefringent photonic crystal fiber
Publication -
Effect of Increased Temperature on Native and Alien Nuisance Cyanobacteria from Temperate Lakes: An Experimental Approach
Publication -
Odour Nuisance at Municipal Waste Biogas Plants and the Effect of Feedstock Modification on the Circular Economy—A Review
Publication -
Semi-Markov Approach to the Shipping Safety Modelling
Publication -
Shipping Safety Management on Polish Inland Waterways
PublicationOver the past years, the role of inland waterway transport has increased compared to other modes of transport. The increasing intensity of the inland vessel traffic significantly affects the safety of navigation. The article analyses the main causes of accidents and incidents that occurred on the Odra Waterway and Lower Vistula. The authors have classified those accidents and suggested possible directions for the development of...
-
CONTAINER SHIPPING MARKET IN THE BALTIC SEA REGION
PublicationThe following article presents the situation on the maritime container transport market in the Baltic Sea Region. In the first part the author focuses on describing the specifics of the economic and geopolitical area of the Baltic Sea. The following parts include the market container shipping description along with its individual participants, such as carriers or seaports. Finally, the dynamic development of Polish container ports...
-
Two-phase flow in heterogeneous porous media with non-wetting phase trapping
PublicationThis article presents amathematical model describing flowof two fluid phases in a heterogeneous porous medium. Zaproponowano model matematyczny przepływu dwufazowego w drobnoziarnistym ośrodku porowatym zawierającym inkluzje gruboziarniste. Inkluzje charakteryzują się niższą wartością ciśnienia wejścia dla płynu niezwilżającego (np. powietrze, ropa naftowa) niż materiał podstawowy. Podczas nawadniania takiego ośrodka dochodzi do...
-
Mitigating Stripping in Asphalt Mixtures: Pretreatment of Aggregate by Thermoplastic Polyethylene Powder Coating
Publication -
Experimental and Numerical Analysis of Air Trapping in a Porous Medium with Coarse Textured Inclusions
PublicationThe paper presents a 2D upward infiltration experiment performed on a model porous medium consisting of fine sand background with two inclusions made of coarser sands. The purpose of the experiment was to investigate the effects of structural air trapping, which occurs during infiltration as a result of heterogeneous material structure. The experiment shows that a significant amount of air becomes trapped in each of the inclusions. Numerical...
-
The effect of groyne field on trapping macroplastic. Preliminary results from laboratory experiments
PublicationMacroplastic, a precursor of microplastic pollution, has become a new scope of research interest. However, the physical processes of macroplastic transport and deposition in rivers are poorly understood, which makes the decisions of where to locate macroplastic trapping infrastructure difficult. In this research, we conducted a series of experiments in a laboratory channel, exploring the impact of groynes and flexible artificial...
-
The use of gas chromatography combined with chemical and sensory analysis to evaluate nuisance odours in the air and water environment
Publication -
Frequency and Nuisance Level of Adverse Events in Individuals Receiving Homologous and Heterologous COVID-19 Booster Vaccine
Publication -
Eau, l'INDUSTRIE, les Nuisances
Journals -
Environmental Implications of Oil Spills from Shipping Accidents
PublicationWzrost znaczenia ropy naftowej w XX wieku i w związku z tym, zwiększenie się światowej floty tankowców zwróciły uwagę na negatywne skutki transportu morskiego. Katastrofy z udziałem tankowców pokazały, jak dramatyczne w skutkach mogą być wycieki produktów ropopochodnych z uszkodzonych lub zatopionych jednostek. Skutki wycieku ropy na morzu zależą od wielu czynników, takich jak parametry fizyko-chemiczne paliwa, charakterystyka...