Publications
Filters
total: 786
Catalog Publications
Year 2014
-
Integration of thermographic data with the 3D object model
PublicationThe aim of the paper is to present new method for merging the 3D model data of the measured object with thermograms. Our technique is based on the combination of visual 3D imaging technique and thermal imaging technique, which maps the 2D thermograms on to 3D anatomical mesh model. The combination of these imaging modalities allows the generation of combined 3D and thermal data from which thermal signatures can be verified and...
-
Interaction of SrTi0.65Fe0.35O3-δ with LaNi0.6Fe0.4O3-δ, La0.6Sr0.4Co0.2Fe0.8O3-δ and Ce0.8Gd0.2O2-δ
PublicationIron doped strontium titanates SrTi1-xFexO3-δ are perovskites of versatile properties. They can be used in solid oxide fuel cells or high temperature oxygen sensors. Their reactivity with electrolyte materials, cathode buffer layer materials, other cathode materials or current collector layers has not been fully tested. In this study we use X-ray diffraction to check SrTi0.65Fe0.35O3-δ compatibility with Ce0.8Gd0.2O2-δ (used as...
-
Interaction with medical data using QR-codes
PublicationBar-codes and QR-codes (Quick Response ) are often used in healthcare. In this paper an application of QR-codes to exchange of laboratory results is presented. The secure data exchange is proposed between a laboratory and a patient and between a patient and Electronic Health Records. Advanced Encryption Standard was used to provide security of data encapsulated within a QR-code. The experimental setup, named labSeq is described....
-
Interactions with recognized objects
PublicationImplicit interaction combined with object recognition techniques opens a new possibility for gathering data and analyzing user behavior for activity and context recognition. The electronic eyewear platform, eGlasses, is being developed, as an integrated and autonomous system to provide interactions with smart environment. In this paper we present a method for the interactions with the recognized objects that can be used for electronic...
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Modeling of subarachnoid space width change caused by blood circulation in brain vessels
PublicationThe subarachnoid space is an anatomic space, lying in the central nervous system, between the arachnoid membrane and the pia mater. It is filled with cerebrospinal fluid, which protects and nourishes the brain. The pathological disorder of the subarachnoid space (i.e. increase or decrease of its width) a ects the nervous system. Therefore, it is important to diagnose the width changes of the subarachnoid space. One way to support...
-
Monitorowanie zabiegów kardiochirurgicznych
PublicationNiniejszy rozdział jest poświęcony analizie możliwości wykorzystania obiektywnych ilościowych metod pomiarowych w podczerwieni do oceny procedur interwencji kardiochirurgicznych, głównie procedur standardowych, powszechnie stosowanych w praktyce medycznej. Prezentowane wyniki uzyskano, realizując projekty badawcze, w szczególności grant KBN 3T11E 010 27 „Analiza technik diagnostycznych i terapeutycznych w celu minimalizacji ryzyka...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Pracujący w czasie rzeczywistym system detekcji gazów wykorzystujący przenośny komputer Raspberry PI oraz matrycę półprzewodnikowych czujników gazu
PublicationThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and lowcost alternative for other devices, like gas‑analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
Preparation and characterisation of solution-cast Nafion membrane
PublicationNafion is a commercial name for a perfluorosulfonic polymer, which has been developed in 1962 by Dupont de Nemours. This polymer consists of a polytetrafluoroethylene backbone and regular spaced long perfluorovinyl ether pendant side chains terminated by a sulfonate ionic group. These sulfonate groups are responsible for cation-exchange properties of Nafion. Thanks to the ion-exchange properties, water permeability, good chemical,...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Przenośny analizator stężeń gazów toksycznych jako urządzenie działające w rozproszonym systemie pomiarowym
PublicationW artykule opisano koncepcję przenośnego analizatora stężeń gazów toksycznych, który został zrealizowany jako urządzenie przystosowane do pracy w systemie rozproszonym. Przenośny analizator stężeń gazów toksycznych wykorzystując rozwiązania stosowane w nowoczesnych systemach pomiarowych realizuje pomiar odpowiedzi czujników gazu oraz umożliwia prezentację, archiwizację i analizę pomierzonych wielkości.
-
Rating mathematical models for first-pass of tracer in pCT lung studies
PublicationThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Rozdział 15. Aktywna termografia dynamiczna
PublicationW ujęciu ogólnym termografia dynamiczna oznacza rejestrację i analizę obrazów rozkładów temperatury w czasie. W aplikacjach medycznych dotyczy badania różnych aspektów fizjologii organizmu; zarówno reakcji zachodzących na skutek oddziaływania na człowieka zmiennych czynników zewnętrznych, jak i toczących się w organizmie procesów metabolicznych. W rozdziale tym ograniczymy się do omówienia tzw. aktywnej termografii dynamicznej...
-
Sleep Apnea Detection by Means of Analyzing Electrocardiographic Signal
PublicationObstructive sleep apnea (OSA) is a condition of cyclic, periodic ob-struction (stenosis) of the upper respiratory tract. OSA could be associated with serious cardiovascular problems, such as hypertension, arrhythmias, hearth failure or peripheral vascular disease. Understanding the way of connection between OSA and cardiovascular diseases is important to choose proper treatment strategy. In this paper, we present a method for integrated...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublicationIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Stabilność odpowiedzi półprzewodnikowych czujników gazu w zmiennych warunkach środowiskowych – badania długoterminowe oraz korekcja dryftu
PublicationJednym z mankamentów związanych z użytkowaniem półprzewodnikowych czujników gazu jest brak ich stabilności długoterminowej związanej, między innymi, z wpływem czynników środowiskowych takich jak temperatura bądź wilgotność. Badania nad wpływem tych czynników na stabilność odpowiedzi czujników są niezbędne, gdyż poznanie mechanizmu ich oddziaływania jest kluczowe dla opracowania skutecznych algorytmów kompensacyjnych umożliwiających...
-
Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications
PublicationA composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...
-
Wpływ kształtu elektrody woltamperometrycznej na jej właściwości metrologiczne w dziedzinie czasu
PublicationW artykule omówiono właściwości metrologiczne elektrod woltamperometrycznych. Wykazano, że w przypadku oznaczania małych wartości stężeń jonów metali, elektrody te zachowują się tak jak przetworniki pomiarowe I rzędu. Ich właściwości metrologiczne opisuje czułość i stała czasowa. Wartości tych wielkości są uzależnione od mechanizmu transportu jonów do/od powierzchni elektrod oraz od ich kształtu. Wykonano symulacje wpływu kształtu...
Year 2015
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A Special Section on Intelligent User Interfaces in Healthcare (IUIH)
PublicationA concept of interface has evolved from the first appearance in the form of a command line interface to the established use of direct manipulation or WIMP (windows, icons, menus and pointing) interfaces in nearly all applications. Intelligent user interfaces (IUI) form a subfield of Human-Computer Interaction research. Optimal human-computer interactions are defined as ones where users are able to perform complex tasks more quickly...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Active and Dynamic Graphical Code for Object Identification in Healthcare
PublicationA new approach for item marking using two dimensional discrete graphics markers. Proposed solution allow o change the code rapidly, upon request and in the case of thermal markers make the code invisible for unauthorized observers. Connecting the proposed codes with wearable multmedial platform such as eGlasses can create new possibilities in human-environment interaction.
-
Algorytmy obróbki danych dla diagnostyki ran pooperacyjnych w kardiochirurgii
PublicationDo oceny procesu gojenia ran pooperacyjnych wykorzystana została koncepcja aktywnej termografii dynamicznej (ATD) z pobudzeniem w postaci nawiewu mieszaniny powietrza i rozprężonego CO2. Specyficzne dla aplikacji oceny gojenia ran jest przetwarzanie uzyskanych sekwencji termogramów polegające na analizie rozkładów parametrów modelu dwueksponencjalnego wzdłuż linii cięcia w kolejnych dwóch badaniach - w trzeciej i szóstej dobie...
-
Application of smart glasses for fast and automatic color correction in health care
PublicationIn recent years different applications of smart glasses in health care have been proposed. In this paper we present the experiments related to automatic color correction using smart glasses platform developed within the eGlasses project. The color pattern is proposed and tested enabling the automatic detection of the pattern and automatic correction of colors. Additionally, the method for encoding and decoding of patient ID in...
-
Assesment of (Mn,Co)3O4powders for possible coating material for SOFC/SOEC interconnects
PublicationIn this work (Mn,Co)3O4 spinel powders with different Mn:Co ratio (1:1 and 1:2) and from different commercial suppliers are evaluated for possible powder for production of interconnect coatings. Sinterability of the powders is evaluated on pressed pellets sintered in oxidizing and in reducing/oxidizing atmospheres. For selected powder, coatings are then prepared by the electrophoretic deposition method on Crofer 22 APU stainless...
-
Characterization of magnesium doped lanthanum orthoniobate synthesized by molten salt route
PublicationMolten salt synthesis method has been used to prepare the single phase magnesium doped lanthanum orthoniobate. The phase composition has been checked by X-ray diffraction method and the microstructure studies have been performed by scanning electron microscopy. The high temperature properties of the material have been investigated by thermogravimetry and electrochemical impedance spectroscopy. A dependence between sample total...
-
Color Processing for Color-Blind Individuals Using Smart Glasses
PublicationIn this paper we investigated image processing methods for color-blind individuals. In particular we experimentally verified color naming procedure, generation of maps with color perception differences for average observers and for dichromats, and two color transformation methods. In experiments 7 mobile devices were used: 3 smart glasses and 4 smartphones. User studies were performed with 38 average observers and 9 dichromats....
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Deposition and growth of thin ceramic films
Publication: Thin ceramic films play an important role in modern technology. One of the more utilized methods of deposition of ceramic films is spin coating. In this paper we investigate optimal deposition parameters for LaNi0.6Fe0.4O3−δ thin layers spin coated from a polymeric precursor. The quality of the obtained layers is checked using scanning electron microscopy. Additionally, we investigate the growth of grains in ceramic films annealed at...
-
Electrochemical Activity and Electrical Properties of Optimized Polypyrrole Coatings on Iron
PublicationIn this work, electrochemical activity and electrical properties of polypyrrole (PPy) coated iron electrodes have been investigated. PPy film was electrochemically polymerized from sodium salicylate aqueous solution under conditions, which provided an increase of iron corrosion resistance. It was noticed that the pH of the solution and the applied electrode potential range during the study of the polymer properties had an influence...
-
Eye tracking within near-to-eye display
PublicationIn this paper we investigate the effectiveness of the gaze interaction within near-to-eye display. The practical aspect of the paper is about combining an eye tracker with smart glasses. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of the implemented interaction methods is the one...
-
Feasibility Study for Food Intake Tasks Recognition Based on Smart Glasses
PublicationIn this exploratory study 13 adult test subjects have performed different food intake tasks while wearing a three axis accelerometer mounted at a temple of glasses. Two different algorithms for task recognition have been applied and compared. The retrospective data processing leads to better task recognition results when the frequency range of 50 Hz to 100 Hz is analysed within accelerometer signal recordings. A straightforward...
-
Fotometryczny czujnik glukozy oparty na enzymatycznych paskach testowych
PublicationCukrzyca jest chorobą dotykającą co roku na całym świecie około 3 mln ludzi [1]. Brak możliwości wyleczenia choroby generuje koszty związane z jej monitorowaniem. W USA corocznie wydaje się na ten cel 174 mld dolarów [2]. Stężenie glukozy we krwi zdrowego człowieka na czczo waha się od 80 mg/dl do 110 mg/dl [3]. Stan organizmu z niedoborem glukozy nazywany jest hipoglikemią, a stan podwyższonej zawartości cukru – hiperglikemią...
-
High temperature corrosion and corrosion protection of porous Ni22Cr alloys
PublicationIn this work corrosion kinetics of the porous IN625 alloy is studied in the temperature range of 700 °C – 800 °C in air and humidified hydrogen for up to 1000 hours. Moreover, an effective and simple method of reducing corrosion rates of porous alloys by the infiltration of the rare earths elements is shown. Modification by the yttrium containing precursor reduces the corrosion rate by a factor of 50 in air at 700 °C so that the...
-
Influence of electropolymerization conditions on the morphological and electrical properties of PEDOT film
PublicationIn this work the effects of electropolymerization conditions on the morphological properties and conductivity of poly(3,4-ethylenedioxythiophene) (PEDOT) film have been studied. PEDOT films were electrochemically synthesized in a one step process from acetonitrile solution containing 3,4-ethylenedioxythiophene (EDOT) and lithium perchlorate. Based on atomic force microscopy, scanning electron microscopy, cyclic voltammetry and...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublicationMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
Interactions using passive optical proximity detector
PublicationIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
Interactions with recognized patients using smart glasses
PublicationRecently, different smart glasses solutions have been proposed on the market. The rapid development of this wearable technology has led to several research projects related to applications of smart glasses in healthcare. In this paper we propose a general architecture of the system enabling data integration for the recognized person. In the proposed system smart glasses integrates data obtained for the recognized patient from health...
-
Investigation of catalytic layers on anode for solid oxide fuel cells operating with synthetic biogas
PublicationIn this paper solid oxide fuel cells operating with dry synthetic biogas have been examined. In order to increase their stability the layers of CuO-CeO2, Cu1.3Mn1.7O4 and Y0.08Sr0.92Ti0.8Fe0.2O3 -δ have been deposited on the Ni-YSZ anode site. These layers should catalyze the internal biogas reforming and prevent the carbon deposition on the anode site. It has been found that CuO-CeO2 and Cu1.3Mn1.7O4 catalysts led to an increase...
-
Investigation of thin perovskite layers between cathode and doped ceria used as buffer layer in solid oxide fuel cells
PublicationIn this paper, thin perovskite layers between cathode material of solid oxide fuel cells and gadolinia-doped ceria buffer layer are investigated. Thin layers made of LaNi0.6Fe0.4O3-δ (LNF), La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF), or SrTi0.65Fe0.35O3-δ (STF) were symmetrically deposited by spin coating method from metallo-organic polymer precursors on a Ce0.8Gd0.2O2-δ (CGO) substrate. Porous and about 40-μm-thick LNF cathodes were deposited...
-
LaNi1-xCoxO3-δ(x=0.4 to 0.7) cathodes for solid oxide fuel cells by infiltration
PublicationPerformance of LaNi 1-x Co x O 3−δ (LNC) (x=0.4 to 0.7) as a cathode in solid oxide fuel cell (SOFC) is evaluated. Symmetrical cathode/electrolyte/cathode cells for electrochemical testing are prepared by infiltration of yttria stabilized zirconia (YSZ) backbone with LNC solutions. It is showed that the cathode infiltrated with LaNi 0.5 Co 0.5 O 3−δ (LNC155) has the lowest polarization resistance and activation energy, 197 mΩ cm...
-
Local Texture Pattern Selection for Efficient Face Recognition and Tracking
PublicationThis paper describes the research aimed at finding the optimal configuration of the face recognition algorithm based on local texture descriptors (binary and ternary patterns). Since the identification module was supposed to be a part of the face tracking system developed for interactive wearable computer, proper feature selection, allowing for real-time operation, became particularly important. Our experiments showed that it is...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Lung perfusion parameters in the diagnosis of diabetic pulmonary microangiopathy
PublicationThis paper presents the role of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. In this article we focus on conditions that are necessary for such the diagnosis and introduce method of classification no microangiopathy vs. microangiopathy based on logistic regression....
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Quality of graphical markers for the needs of eyewear devices
Publicationin this paper we propose to cast the problem of identification of people, objects or places into an application for smart glasses that decodes information from graphical markers. We focus on analyzing different factors that can have influence on the processes of the automatic recognition of information from a code. The research we present aims at reviewing recognition performances in function of: size of a marker, distance from/to...
-
Septic safe interactions with smart glasses in health care
PublicationIn this paper, septic safe methods of interaction with smart glasses, due to the health care environment applications consideration, are presented. The main focus is on capabilities of an optical, proximity-based gesture sensor and eye-tracker input systems. The design of both interfaces is being adapted to the open smart glasses platform that is being developed under the eGlasses project. Preliminary results obtained from the...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublicationUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Thermal ablation modeling via the bioheat equation and its numerical treatment
PublicationThe phenomenon of thermal ablation is described by Pennes’ bioheat equation. This model is based on Newton’s law of cooling. Many approximate methods have been considered because of the importance of this issue. We propose an implicit numerical scheme which has better stability properties than other approaches.
-
Thermal Imaging in Wound Healing Diagnostics
PublicationOpisano wyniki projektu badawczego poświęconego opracowaniu metody obiektywnej diagnostyki ran pooperacyjnych w kardiochirurgii. Sprawdzono możliwość połączenia oceny obrazów RGB z obrazami termograficznymi oraz nową w medycynie metodą aktywnej termografii dynamicznej ADT. W projekcie zastosowano chłodzenie obszaru zainteresowania wykorzystując kriostat na dwutlenku węgla. W okresie powrotu do stanu równowagi termodynamicznej rejestrowane...
-
Thermal Imaging in Wound Healing Diagnostics
PublicationResults of a project searching for objective, quantitative evaluation of postoperative wound healing in cardiosurgery are presented. We propose simple thermal models of the healing processes after cardiosurgery interventions as objective descriptors allowing classification of patients for extraction and following recovery at home or for prolonged treatment in a hospital. Classification of healing as the normal process or as a process...
-
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublicationMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Tools for Automatic Wound Healing Evaluation
PublicationFinal results of the research project devoted to development of a new objective and quantitative method of post cardiosurgery wound healing diagnostics, already preliminary discussed at the QIRT 2014 Conference, is presented. We assumed that thermal processes should be effective in subtle description of temporal changes of tissue thermal properties after surgical interventions. To prove this assumption more than 400 patients after...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublicationThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Visual Attention Distribution Based Assessment of User's Skill in Electronic Medical Record Navigation
PublicationCurrently, the most precise way of reflecting the skills level is an expert’s subjective assessment. In this paper we investigate the possibility of the use of eye tracking data for scalar quantitative and objective assessment of medical staff competency in EMR system navigation. According to the experiment conducted by Yarbus the observation process of particular features is associated with thinking. Moreover, eye tracking is...
-
Wykorzystanie monitorowania i analizy aktywności wzrokowej do oceny pracy z Systemem Informacji Szpitalnej
PublicationRozprawa doktorska przedstawia możliwość wykorzystania monitorowania i analizy aktywności wzrokowej do oceny pracy z Systemem Informacji Szpitalnej. W ramach rozprawy opracowano system do akwizycji rozkładu atencji wzrokowej w wieloekranowym środowisku. Przeprowadzono też szereg eksperymentów, które doprowadziły do opracowania współczynnika pozwalającego na określenie poziomu umiejętności osób pracujących z systemem informacji...
-
Zastosowanie metody galwanostatycznej do wyznaczania błędu fazy elektrod woltamperometrycznych
PublicationW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku, gdy reakcja elektrochemiczna kontrolowana jest procesem transportu jonów, elektroda woltamperometryczna zachowuje się tak jak przetwornik pomiarowy I rzędu. Jej właściwości metrologiczne opisane są przez czułość, częstotliwość graniczną, błąd amplitudy i błąd fazy. Przeprowadzona analiza pokazała,...
Year 2016
-
3D polypyrrole structures as a sensing material for glucose detection
PublicationIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublicationTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
A new diagnostic method for evaluation of cardiosurgery wound healing
PublicationOne of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Active IR-Thermal Imaging in Medicine
PublicationIn this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...
-
An electronic nose for quantitative determination of gas concentrations
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Analysis of the parameters of respiration patterns extracted from thermal image sequences
PublicationRemote estimation of vital signs is an important and active area of research. The goal of this work was to analyze the feasibility of estimating respiration parameters from video sequences of faces recorded using a mobile thermal camera. Different estimators were analyzed and experimentally verified. It was demonstrated that the respiration rate, periodicity of respiration, and presence and length of apnea periods could be reliably...
-
Balance recognition on the basis of EEG measurement.
PublicationAlthough electroencephalography (EEG) is not typically used for verifying the sense of balance, it can be used for analysing cortical signals responsible for this phenomenon. Simple balance tasks can be proposed as a good indicator of whether the sense of balance is acting more or less actively. This article presents preliminary results for the potential of using EEG to balance sensing....
-
Barium boron aluminum silicate glass system for solid state optical gas sensors
PublicationRecent increasing demand for new eco-friendly materials and for low cost fabrication process for use in optical sensors field, raise concern about alternative materials for this application. We have designed two glass-ceramics compositions from the quaternary ROAl2O3- SiO2-B2O3(R=Ba) alkali-earth aluminum silicate system, labeled B72 and B69, with high refractive index (>1.6), large values of Abbe number (94.0 and 53.0, respectively),...
-
Cardiovascular data analysis using electronic wearable eyeglasses-preliminary study
Publicationhe paper presents an alternative approach to the monitoring of the cardiovascular system. The study depicts configurations of the utilized system and preliminary results of electrical and mechanical parameters of the cardiac system which can be measured using a head-worn device.
-
CGO as a barrier layer between LSCF electrodes and YSZ electrolyte fabricated by spray pyrolysis for solid oxide fuel cells
PublicationPerovskite La0.6Sr0.4Co0.2Fe0.8O3 − δ (LSCF) is often used as a cathode material for solid oxide fuel cells (SOFC) due to high mixed ionic and electronic conductivity and good catalytic activity. Unfortunately, sintering of the LSCF cathode together with the yttria stabilized zirconia (YSZ) electrolyte, leads to formation of the La2Zr2O7 and SrZrO3 phases in the interface. These phases increase the resistance of the cell. To avoid...
-
Comparison of perforator location in dynamic and static thermographic imaging with Doppler ultrasound in breast reconstruction surgery
PublicationThis paper co mpares the effectiveness of the dTnorm and t90_10 parametrizations in dynamic thermography for imaging location of perforators in TRAM flaps in the intraoperative period. The results were compared with the location detected in a Doppler ultrasound examination. Cold and heat stimulation was used in dynamic thermography. Additionally, these results were compared with static...
-
Conductivity and viscosity changes of imidazolium ionic liquids induced by H2O and CO2
PublicationSeveral solutions of ionic liquids based on 1-ethyl-3-methylimidazolium cation saturated and unsaturated with carbon dioxide were prepared and characterized by electrochemical impedance spectroscopy. The in fluence of ILs saturation on its electrical conductivity was determined. Additionally, the in fluence of the water presence and variations of temperature on electrical properties of ionic liquids were investigated. Changes of...
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
Detekcja osoby w wannie
PublicationStarzenie się społeczeństwa powoduje narastanie problemów chorób wieku starczego. Częstym problemem są zasłabnięcia w wannie podczas kąpieli. Celem publikacji jest przedstawienie metody identyfikacji tkanki ożywionej w wodzie z wykorzystaniem technik elektromagnetycznych. Obserwując zmiany amplitudy i częstotliwości pracy generatorów, pracujących w pętli sprzężenia zwrotnego z cewką, istnieje możliwość scharakteryzowania i określenia...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublicationA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Determination of the ionic conductivity of Sr-doped lanthanum manganite by modified Hebb–Wagner technique
PublicationThe Hebb–Wagne rpolarization method with the electron blocking electrode has been discussed in this paper in aim to determine a partial ionic conductivity of Sr-doped lanthanum manganite.The “limiting current” in the proposed system was measured using the two-point DC technique with additional Pt electrode between LSM and blocking electrode.The electrochemical model based on bulk diffusion processes and Boltzmann statistics has...
-
Electrochemicalsynthesis of 3D nano-/micro-structured porous polypyrrole
PublicationIn this work, electrosynthesis of electroactive, 3D nano-/micro-structured porous polypyrrole film is presented. The PPy film was synthesized potentiostatically in a one-step process from aqueous solution of pyrrole and lithium perchlorate. The growth mechanism of such structure included: the formation of typical globular PPy film, followed by the formation of the PPy fibers, which then took part in the formation of 3D highly porous...
-
EMG and gaze based interaction with graphic interface of smart glasses application
PublicationIn this paper we investigate the effectiveness of the interaction using eye tracking and electromyography. Smart glasses requires reliable interfaces for controlling the graphic content displayed directly in front of the user's eye. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublicationA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
Estimation of blood pressure parameters using ex-Gaussian model
PublicationThe paper presents an example of model-based estimation of blood pressure parameters (onset, systolic and diastolic pressure) from continuous measurements. First, the signal was low pass filtered and its quality was estimated. Good quality periods were divided into beats using an electrocardiogram. Next, the beginning of each beat of the blood pressure signal was approximated basing on the function created from the sum of two independent...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublicationThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Extraction and evaluation of gas-flow-dependent features from dynamic measurements of gas sensors array
PublicationGas analyzers based on gas sensors are the devices which enable recognition of various kinds of volatile compounds. They have continuously been developed and investigated for over three decades, however there are still limitations which slow down the implementation of those devices in many applications. For example, the main drawbacks are the lack of selectivity, sensitivity...
-
Face detection in image sequences using a portable thermal camera
PublicationFace detection is often a first step in quantitative analysis of face images. It is an important research area for visible images and recently also for thermography. Due to technological developments thermal cameras may be embedded into wearable devices to provide remote healthcare. In this paper, we compared three algorithms for face detection in thermal images by testing execution time, accuracy, symmetry ratio and false-positives....
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. To obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at a constant potential of −0.85 V. The GO, RGO and PEDOT-RGO...
-
High Temperature Corrosion Evaluation of Porous Hastelloy X Alloy in Air and Humidified Hydrogen Atmospheres
PublicationIn this work a commercially available porous Hastelloy X alloy is characterized in terms of high temperature corrosion resistance. The alloy was oxidized in the temperature range from 500C to 900C in air and humidified hydrogen for 100 hours. Corrosion rates and porosity changes were measured. Microstructural characterization was performed using X-ray diffractometry and scanning electron microscopy. Results show that porous alloys...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Influence of Sb-substitution on ionic transport in lanthanum orthoniobates
PublicationThe results of ionic transport measurements for the lanthanum orthoniobate substituted with 10 and 30 mol% of antimony (LaNb0.9Sb0.1O4 and LaNb0.7Sb0.3O4) are presented and discussed. The influence of calcium co-doping on these properties has also been analysed. It has been shown that for the investigated material protonic conductivity predominates at temperatures up to 800 °C in oxidizing atmospheres under wet conditions. The...
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Inteligentne otoczenie w aplikacjach prozdrowotnych - przykłady rozwiązań
PublicationW artykule przedstawiono koncepcję inteligentnego otoczenia jako wyposażenia tzw inteligentnego budynku ukieunkowanego na wspomaganie diagnostyki medycznej osób zagrożonych określonymi chorobami. Przedstawiono bliżej dwa rozwiązania – układ inteligentnej wagi i krzesła kardiologicznego.
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Low temperature processed MnCo2O4 and MnCo1.8Fe0.2O4 as effective protective coatings for solid oxide fuel cell interconnects at 750 °C
PublicationIn this study two materials, MnCo2O4 and MnCo1.8Fe0.2O4 are studied as potential protective coatings for Solid Oxide Fuel Cell interconnects working at 750 °C. First powder fabrication by a modified Pechini method is described followed by a description of the coating procedure. The protective action of the coating applied on Crofer 22 APU is evaluated by following the area specific resistance (ASR) of the scale/coating for 5500...
-
Metrological characteristics of the flat voltammetric electrode in time domain with a reversible electrochemical reaction running on the surface
PublicationW artykule przedstawiono właściwości metrologiczne płaskich elektrod woltamperometrycznych. Omówiono wpływ napięcia polaryzującego na wartości parametrów charakteryzujących te elektrody.