Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=5.30, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.20, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=3.30, b=0.40) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=3.30, b=0.40) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=4.40, b=0.42) and (C=6.40, b=0.45) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=7.30, b=0.49) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=5.30, b=0.38) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of flow properties of a serial connection of two pneumatic elements with (C=6.40, b=0.45) and (C=6.20, b=0.38) from changes in air pressure in a tank being emptied
Dane BadawczeThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for two pressure relief valves arranged in-line. Four test configurations were used: (1) being emptied tank -> the first PRV -> ambient atmosphere, (2) being emptied...
-
Determination of mechanical properties of human stomach tissues subjected to uniaxial stretching
Dane BadawczeThe aim of the study was to determine the biomechanical properties of the walls of the human stomach. The samples were fragments of the human stomach obtained after sleeve gastrectomy. Samples cut parallel to the stomach curves and perpendicular to the stomach curves were tested in each series. All samples were subjected to uniaxial stretching. During...
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Determination of viscosity changes of protein hydrolyzate solutions depending on shear rate
Dane BadawczeRheological characteristics of connective tissue protein solutions were made on the basis of viscosity measurement using a Brookfield viscometer using LV SC4 - 27 spindles and shear rate of 85 s-1 (Fig. 1). Solutions of protein hydrolysates with a concentration of 2% in 0.5M acetic acid were prepared.
-
Determination of changes in viscosity of chitosan cosmetic preparations depending on shear rate.
Dane BadawczeThe rheological characteristics of chitosan were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 0.3 to 32 s-1 (Fig. 1). Chitosan solutions at 1% concentrations in acetic acid were prepared. The samples were subjected to storage tests.
-
Determination of the effective concentration of ketoprofen against the germination of Sorghum bicolor (sorghum) seeds
Dane BadawczeResearch data includes an attempt to determine the effective concentration of ketoprofen that inhibits germination of Sorghum bicolor (sorghum) seeds.
-
SEM and Raman studies B:CNWs and BDD electrode used for electrochemical paraquat determination
Dane BadawczeThe dataset contains the scanning electron micrographs (SEM) and Raman spectra of B:CNWs and BDD samples deposited by MW-PECVD. SEM was used to characterise the morphology of BDD and B:CNW. In contrast, RAMAN was used to reveal the main differences in the crystalline structure of BDD and B:CNWs.
-
Determination of the effective concentration of oxyteracycline solutions on the inhibition of bioluminescence of Vibrio fischeri (Microtox)
Dane BadawczeIn this study an attempt was made to determine the effective concentration for oxytetracycline solutions on the inhibition of bioluminescence of Vibrio fischeri (Microtox).
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.1 to 55 s-1).
Dane BadawczeThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.
-
Determination of changes in viscosity of refined oil depending on the temperature (19-96 Celsius degrees).
Dane BadawczeThe rheological characteristics of the refined oil were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 18 spindle and a shear rate of 52.8 s-1 in from temperature 19-96 °C.
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.7 to 34 s-1).
Dane BadawczeThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 34 s-1.
-
Determination of mechanical properties of Ti13Nb13Zr cubes made with STL technology subjected to uniaxial compression
Dane BadawczeThe aim of the study was to determine the mechanical properties of Ti13Nb13Zr cubes made with STL technology (3D printing). The experiments were carried out on the Hung Ta universal test machine HT-2402. Cubes with the initial dimensions of 10x10x10 mm were subjected to compression by increasing force to over 80 kN. In various experiments, the angle...
-
Determination of changes in viscosity of poly(acrylic acid) PAA solutions depending on shear rate.
Dane BadawczeThe rheological characteristics of poly(acrylic acid) PAA solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 27 spindles and shear rates from 1,7 to 39 s-1 (Fig. 1). PAA solutions with were prepared in water. The data allowed to characterize the used PAA and assess their functional parameters as rheology modifying...
-
Determination of the minimum inhibitory concentration of C-1305 derivatives (IKE1-IKE8) against Candida strains
Dane BadawczeThe datasets contain the results of determining the minimum inhibitory concentration of acridone derivatives against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 by the modified M27-A3 specified by the CLSI.
-
Determination of the minimum inhibitory concentration of C-1330 derivatives (IKE9-IKE14) against Candida strains
Dane BadawczeThe datasets contain the results of determining the minimum inhibitory concentration of C-1330 derivatives (IKE9-IKE14) against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 by the modified M27-A3 specified by the CLSI.
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.1 to 55 s-1).
Dane BadawczeThe rheological characteristic of pectin gel (with concetration 0,45% m/m, in three independent repetition of sample) was made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.The data allowed to characterize the used hydrogel preparations and assess their functional...
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.7 to 85 s-1).
Dane BadawczeThe rheological characteristic of pectin gel (with concetration 0,25% m/m, in two independent repetitions) wasmade on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 85 s-1, in temperature of 25 C degee .The data allowed to characterize the used hydrogel preparations and assess...
-
Determination of the minimum inhibitory concentration of new bisacridines IKE15-19 and IKE21, against yeast strains
Dane BadawczeThe datasets contain the results of determining the minimum inhibitory concentration of new bisacridines against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019, S. cerevisiae ATCC 9763 and fluconazole resistant C. albicans strains by the modified M27-A3 specified by the CLSI.
-
Determination of changes in viscosity of high-fructose syrup stability of pectin hydrogels depending on the temperature (25-96 Celsius degrees).
Dane BadawczeThe rheological characteristics of the high-fructose syrup modified stability of pectin (added in a concentration 2% m/m) were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 25 spindle and a shear rate of 0,22 s-1 in the temperature range 25-96 ° C. The data allowed selection of optimal conditions for the...
-
Determination of the MIC (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against C. glabrata clinical strains
Dane BadawczeThe datasets contain the results of determining the MIC value (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against Candida glabrata clinical strains CZD 310, 373, 377, 513 and collection strain DSM 11226 by the modified M27-A3 specified by the CLSI.
-
The estrogenicity of wastewater samples.
Dane BadawczeThe principle of operation of the kit is based on the fact that the tested sample with endocrine activity (containing compounds capable of binding to the human estrogen receptor α, hERα) releases the fluorescently labeled ligand (FluormoneTM ES2) from the receptor-ligand complex, which results in a reduction of the polarization value fluorescence. The...
-
Determination of flow properties of a pneumatic hose from changes in air pressure in a tank being emptied or filled by a differently configured pneumatic line
Dane BadawczeThe aim of the study was to determine the flow properties of various pneumatic hoses. The experiments were to measure the pressure changes in a being filled or emptied tank for a differently configured pneumatic line, including pneumatic hoses of different length and diameter. Three test configurations were used: (1) pressure source -> pneumatic...
-
Minimum inhibitory concentrations (MICs) determination of selected human topoisomerase II alpha and bacterial DNA gyrase inhibitors against fungal strains
Dane BadawczeThe datasets contain the results of determining the MIC (Minimal Inhibitory Concentration) value of known compounds* (inhibitors of human topoisomerase II alpha and bacterial DNA gyrase) against C. albicans SC5314, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 and Saccharomyces cerevisiae ATCC 9763 by the modified M27-A3...
-
Revenues from operating activities of non-public universities in Poland in 2010 (PLN thousand)
Dane BadawczeIn 2010, in non-public universities, 90.2% of revenues from operating activities were revenues from teaching activities. Revenues from research activity accounted for 2.8%, and other types of activity accounted for 6.9% of total operating revenues.Income from teaching activities of universities may be obtained from budget subsidies, funds to local governments...
-
Free-air anomaly grid on the Gulf of Gdańsk
Dane BadawczeWe present an attempt to determine the accuracy of shipborne gravimetry for the needs of geoid determination. The shipborne gravity campaign, is the beginning of a series of gravimetry measurements in the Polish Exclusive Economy Zone. The campaign was conducted in the area where the accuracy of geoid determination is crucial for the safety of navigation...
-
Determination of the minimum inhibitory concentration of C-1311 derivatives (C-1296, C-1410, Compound 1, Compound 1-R8) against Candida strains
Dane BadawczeThe datasets contain the results of determining the minimum inhibitory concentration of imidazoacridinone derivatives against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 and C. albicans clinical strains by the modified M27-A3 specified by the CLSI.
-
Physicochemical and photocatalytic data of TiO2/MXene/MnFe2O4 photocatalysts
Dane BadawczeThis dataset includes data regarding the physicochemical properties (i.e. XRD, DR/UV-vis, TEM images, photoluminescence) and photocatalytic activity of TiO2/MXene/MnFe2O4 photocatalysts. The data comprise the results of the photocatalytic reaction of carbamazepine and ibuprofen degradation.
-
Comparison of Poland, Germany and the European average using the components of the summary innovation index
Dane BadawczeThe analysis presents a comparison of the innovation policies of Poland and Germany using all the indicators included in the Summary Innovation Index (SII), then the obtained results were analyzed and conclusions were formulated.The indicators are divided into three main categories, each group of indicators shows a different aspect of the innovativeness...
-
Effect of particle size of aluminosilicate microspheres on the change of hydration heat of cement mortars and selected physical, chemical, and mechanical properties.
Dane BadawczeThis subject of the work is the study of selected properties of cement mortars containing two fractions of aluminosilicate microspheres with grain size in the range of 125 to 250 μm and from 250 to 500 μm. Mortar mixtures with ordinary Portland cement (OPC 42.5R) and three substitution rates of cement by microspheres, 1.5%, 3.5%, and 5.0%, were investigated....
-
UV-Vis-DR-TiO2 heated at 400-600oC in Ar or H2
Dane BadawczeThese data contain UV-Vis/DR spectra of TiO2 heated at 400-600oC in Ar or H2. Transformation of spectra to Kubelka-Munk function was performed together with determination of band gap.
-
Physicochemical and photocatalytic data of Cu-TiO2/Ti3C2 composites
Dane BadawczeIn this dataset, we include the data regarding the physicochemical properties (XRD, DR/UV-vis, photoluminescence, electrochemistry) and photocatalytic activity of TiO2/Ti3C2 and Cu-TiO2/Ti3C2 composites in the reaction of carbamazepine degradation. Herein we present the results for pure TiO2/Ti3C2 and composites modified with copper particles (0.25%,...
-
Value of tax preferences in 2009-2015 as a percentage of Polish GDP
Dane BadawczeThis research data shows the percentage of the amount of tax preferences as a percentage of Polish GDP between 2009-2015. The data contained in this dataset has been collected by the Polish Ministry of Finance.
-
NADES propolis extracts - update 2023 and synthesis of derivatives of propolis ingredients
Dane BadawczeThis dataset contains results of our investigation aiming in determination of antimicrobial potential of the propolis extracts produced with deep eutectic solvents
-
DES - polarity, pH and antioxidant potential
Dane BadawczeThis physicochemical properties of selected deep eutectic solvents (DES) were tested. Polarity is important for extraction efficiency. The values of pH can importantly affect growing of bacteria and yeasts strains. Total phenolic content, DPPH and FRAP methods were used for determination of antioxidant potential of the extract produced with DES.
-
Flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to TXT2 and TXT4
Dane BadawczeThe data contains flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to equitoxic concentrations of TXT2 and TXT4. DMSO and MTX were used as positive and negative controls, respectively. Caspase 3/7 activity was detected using CellEvent™ Caspase-3/7 Green Flow Cytometry Assay Kit (#C10427, Thermo Fisher Scientific)....
-
MIC/MBC values of the investigated extracts of propolis. Interactions of selected extracts with azoles and echinocandins.
Dane BadawczeThis dataset contains results of our investigation aiming in determination of antimicrobial potential of the propolis extracts produced in our laboratory. The propolis samples were delivered by Polish beekeepers. Moreover in this dataset we presented results of our investigation aiming in assessment of interaction of the selected extracts of propolis...