Filtry
wszystkich: 7448
wybranych: 5191
-
Katalog
- Publikacje 5191 wyników po odfiltrowaniu
- Czasopisma 47 wyników po odfiltrowaniu
- Konferencje 24 wyników po odfiltrowaniu
- Osoby 78 wyników po odfiltrowaniu
- Projekty 7 wyników po odfiltrowaniu
- Kursy Online 27 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 2071 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: HIGH-VOLTAGE TRANSFORMERS
-
Single and Three -Phase PWM AC/AC Converters as Semiconductor Transformers
PublikacjaAC voltage transformation circuits contain pure or reactance PWM AC/AC converters. These circuits can be treated as AC/AC semiconductor transformers. This paper reviews single-phase and three-phase topologies: both non-isolated and isolated, single as well as two quadrant structure. Additionally, this paper present selected examples of their applications.
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
A novel dual-band rectifier circuit with enhanced bandwidth for RF energy harvesting applications
PublikacjaIn recent years, a rapid development of low-power sensor networks, enabling machine-to-machine communication in applications such as environmental monitoring, has been observed. Contemporary sensors are normally supplied by an external power source, typically in a form of a battery, which limits their lifespan and increases the maintenance costs. This problem can be addressed by harvesting and converting ambient RF energy into...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublikacjaThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Badania laboratoryjne wybranych sposobów koordynacji regulatora transformatora blokowego oraz regulatora generatora
PublikacjaWprowadzenie wymogu stosowania transformatorów blokowych z przekładnią regulowaną pod obciążeniem spowodowało konieczność określenia właściwego sposobu podziału kryteriów sterowania pomiędzy regulator generatora a regulator transformatora blokowego. W referacie zwrócono uwagę na aspekt miejsca pomiaru napięć. Ma to istotny wpływ zarówno na algorytm jak i jakość regulacji. Rozważania teoretyczne zilustrowane zostały wynikami prób...
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Single-Phase 15-Level Switched-Capacitor Boost Multilevel Inverter Topology for Renewable Energy Applications
PublikacjaGalvanic isolation is a vital part of a grid-connected solar PV system. With the growth of multilevel inverters for grid-connected applications, the multilevel inverters having isolation are not sufficiently discussed in the literature. In this paper, a 15-level isolated multilevel inverter topology requiring only thirteen switches is proposed. The envisaged configuration includes two cells, designated as upper and lower cells....
-
An Overview of Bidirectional EV Chargers: Empowering Traction Grid-Powered Chargers
PublikacjaIn recent years, the number of electric vehicles has been at least doubling year after year. As a result, today electric vehicles already account for approximately 10% of the global automotive market, which positively affects environment in urbanized areas. However, to take full advantage of the EV integration it is necessary to use renewable sources for their charging; optimally place charging stations/terminals; optimally manage...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublikacjaNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublikacjaW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer
PublikacjaPower transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublikacjaArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublikacjaThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublikacjaSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
Algorytmy wykrywania krawędzi w obrazie
PublikacjaWykrywanie krawędzi jest pierwszym etapem w cyfrowym przetwarzaniu obrazów. Operacja ta polega na usunięciu informacji takich jak kolor czy też jasność, a pozostawieniu jedynie krawędzi. Efektem tej operacji jest znaczna redukcja ilości danych do dalszej analizy. Pozwala to na zastosowanie w następnych etapach bardziej złożonych algorytmów rozpoznawania obiektów na podstawie kształtu. W artykule zaprezentowano zastosowanie algorytmów...
-
Modelowanie bezpiecznika rozłącznikowego w układach formowania impulsów wielkiej mocy
PublikacjaProblem modelowania bezpieczników o dużej dynamice wyłączania prądu jest zagadnieniem szeroko opisywanym w literaturze. Układy takie mogą być wykorzystane w szczególności do formowania impulsów wysokiego napięcia o wartościach rzędu setek kV, charakteryzujących się czasem trwania rzędu ułamka μs. W niniejszej pracy przedstawiono empiryczny model bezpiecznika wielotopikowego, rozszerzony w oparciu o wyniki badań eksperymentalnych.
-
Nowoczesne układy przekształtników wielopoziomowych do zasilania statków z lądu
PublikacjaW artykule poruszono tematykę zasilania statków zacumowanych w porcie z lądowej sieci elektroenergetycznej poprzez wykorzystanie nowoczesnych konstrukcji przekształtników energoelektronicznych. W treści pracy zaprezentowano porównanie dwóch topologii wysokonapięciowych przekształtników wielopoziomowych. Porównano konstrukcje przekształtników z klasycznym transformatorem wielouzwojeniowym oraz z transformatorami wysokoczęstotliwościowymi.
-
Pompownie dużej mocy z falownikiem wędrującym średniego napięcia
PublikacjaArtykuł zawiera rys rozwoju napędów przekształtnikowych w stacjach pomp, w szczególności regulacji wydatku kilku pomp, po kolei, przez jeden przemiennik częstotliwości. Omówiono podstawy teoretyczne zjawiska pola niestłumionego i napięcia resztkowego silników, które utrudniają szybkie przełączania silnika pompy pomiędzy zasilaniem regulowanym przez falownik a zasilaniem z sieci. Przedstawiono zasady transferu (przełączania) synchronicznego...
-
WARUNKI REZONANSOWE W WĘŹLE Z KOMPENSATOREM SVC
PublikacjaInstalowanie kompensatorów statycznych w sieciach rozdzielczych i przesyłowych służy poprawie profili napięciowych. Kompensatory jako źródła mocy biernej zwiększają stabilność napięciową systemu. Pozwalają także na szybszą odbudowę systemu w przypadku awarii napięciowej. W artykule zaprezentowano wpływ struktury i wysterowania układu SVC na zmianę impedancji w układzie zasilania. Ma to bezpośredni wpływ na częstotliwości, przy...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublikacjaFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
SVC and power transformers controllers coordination
PublikacjaThe use of shunt compensators such as FACTS (for example SVC) in power systems gives possibility of fast and flexible control of voltage or reactive power. An efficient cooperation between a transformer and compensator connected to busbars, or transformer’s tertiary winding, requires a proper coordination of controls. The article contains theoretical considerations and simulation results which indicate that such co-ordination is...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Cost-efficient simulation-driven design of compact impedance matching transformers
PublikacjaIn this paper, an algorithmic framework for cost-efficient design optimization of miniaturized impedance matching transformers has been presented. Our approach exploits a bottom-up design that involves translating the overall design specifications for the circuit at hand to its elementary building blocks (here, compact microstrip resonant cells, CMRCs), as well as fast surrogate-assisted optimization of the cells followed by simulation-based...
-
Comparison of Transmission Capacities of Two Regulation Systems: Lateral and in-phase Control Transformers
PublikacjaThis paper presents a comparison of regulation capabilities of lateral and in-phase control transformers in a selected node of a power system. Their regulation capabilities are presented, as well as cross-system exchange options.
-
Voltage Dependence of Supercapacitor Capacitance
PublikacjaElectronic Double-Layer Capacitors (EDLC), called Supercapacitors (SC), are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Multidirectional CATV transformers
PublikacjaZaproponowano nowe transformatory wielouzwojeniowe, nazwane tu transformatorami wielokierunkowymi, na zakres częstotliwości CATV od 5 MHz do 862 MHz, przeznaczone do zastosowania w separatorach multimedialnych jako pasywne dzielniki mocy. Zaprezentowano typowe charakterystyki zaprojektowanych transformatorów: jednokierunkowego, dwukierunkowego i czterokierunkowego, uzyskane w wyniku pomiarów, i porównano je z wynikami modelowania...
-
Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia
PublikacjaW związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...
-
Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation
PublikacjaThe article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublikacjaThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Response features for fast EM-driven design of miniaturized impedance matching transformers
PublikacjaA framework for low-cost EM-driven design optimization of compact impedance matching transformers is presented. Our technique is based on a bottom-up design where design requirements for the transformer circuit are translated into specifications for its building blocks. These elementary cells are optimized using response features. Subsequently, the entire circuit is fine-tuned using local response surface approximation models and...
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublikacjaA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Rozpoznawanie oraz lokalizacja w obrazie przewodów linii wysokiego napięcia
PublikacjaW pracy przedstawiono opracowany algorytm rozpoznawania oraz lokalizacji przewodów linii wysokiego napięcia na podstawie obrazu horyzontalnego. Procedura detekcji przewodu została podzielona na trzy etapy. Pierwszy etap zawiera algorytm wykrywania krawędzi wykazujący największą czułość na krawędzie poziome, a jednocześnie brak czułości na krawędzie pionowe. Efektem jest znaczna redukcja liczby wykrytych krawędzi w porównaniu do...
-
Zastosowanie sygnałów o projektowanych kształtach do diagnostyki obiektów wysoko-impedancyjnych metodą spektroskopii impedancyjnej
PublikacjaW artykule przedstawiono metodę szybkiej spektroskopii impedancyjnej obiektów o wysokich impedancjach (|Zx| > 1 GOhm) z zastosowaniem sygnałów o projektowanych kształtach. Sygnał pobudzenia wytwarzany jest w module DAQ U2531A i doprowadzany na wejście badanego obiektu za pośrednictwem przetwornika cyfrowo-analogowego (CA). Sygnały odpowiedzi proporcjonalne do napięcia na mierzonej impedancji Zx oraz prądu płynącego przez Zx są...
-
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
PublikacjaWith an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...
-
EM-Driven Multi-Objective Design of Impedance Transformers By Pareto Ranking Bisection Algorithm
PublikacjaIn the paper, the problem of fast multi-objective optimization of compact impedance matching transformers is addressed by utilizing a novel Pareto ranking bisection algorithm. It approximates the Pareto front by dividing line segments connecting the designs found in the previous iterations, and refining the obtained candidate solutions by means of poll-type search involving Pareto ranking. The final Pareto set is obtained using...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublikacjaThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
Uziemienia w zespołach elektrowni wiatrowych
PublikacjaW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
Modelling and analysis of medium frequency transformers for power converters
PublikacjaThe evolutions in power systems and electric vehicles, related to the economic opportunities and the environmental issues, bring the need of high power galvanically isolated DC-DC converter. The medium frequency transformer (MFT) is one of its key components, enabled by the increasing switching frequency of modern power semiconductors like silicon carbide transistors or diodes. The increased operating frequency offers small...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublikacjaThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Medium voltage drives - challenges and requirements
PublikacjaThe design and application of medium voltage (MV) drives are associated with different requirements related to the line side and motor side of the drive. This paper presents a brief review of the existing challenges and requirements for employing medium voltage drives in various industries. Line side, motor side, and converterproblems and requirements are described. The aim of the paper is to review the existing problems to allow...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublikacjaPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publikacja—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Static Shunt PE Voltage-Quality Controllers
PublikacjaThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Supercapacitors - charge redistribution and restoring voltage
PublikacjaThe charge in supercapacitor is stored on electrodes and in electrolyte. The charges on electrodes create the Helmholtz double layer which is formed immediately with time constant of the order of seconds, while the charge storage in electrolyte is going on with time constant of the order of hundreds seconds. When the charged supercapacitor is shorted for few seconds, the charge from electrodes is discharged while the charge in...