Filtry
wszystkich: 1061
wybranych: 826
Wyniki wyszukiwania dla: IMPEDANCE MATCHING TRANSFORMERS
-
Linear and nonlinear impedance in iron oxide glasses containing alkaline ions and alkali free
PublikacjaThe linear and nonlinear impedance spectra of oxide glasses were measured in the frequency range of 1 mHz to 1 MHz and in the temperature range of 153K to 483K. Two groups of iron oxide glass samples were prepared, the first one containing alkaline ions and the second one without alkali. In the first group, compositions of glasses were as follows: (in %mol) 50% SiO2 , 25% PbO, 15% Fe2O3 and 15% one of alkaline oxides: Na2O, K2O,...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublikacjaThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
The impedance of hydrogen oxidation reaction in a proton exchange membrane fuel cell in the presence of carbon monoxide in hydrogen stream
PublikacjaEvaluation of performance of a proton exchange membrane fuel cell, which is affected by carbon monoxide that pollutes the hydrogen stream, was presented. This influence was studied for carbon monoxide concentration of 125–325 ppb, which are close to values specified in ISO 14687:2019 standard. Performed studies provided crucial information for further development of fuel cell as an energy source for automotive application. Impedance...
-
Improving Accuracy of Respiratory Rate Estimation by Restoring High Resolution Features With Transformers and Recursive Convolutional Models
PublikacjaNon-contact evaluation of vital signs has been becoming increasingly important, especially in light of the COVID- 19 pandemic, which is causing the whole world to examine people’s interactions in public places at a scale never seen before. However, evaluating one’s vital signs can be a relatively complex procedure, which requires both time and physical contact between examiner and examinee. These re- quirements limit the number...
-
Application of Galvanostatic Non-Linear Impedance Spectroscopy to the Analysis of Metallic Material Degradation
PublikacjaThis study presents a novel application of Non-Linear Electrochemical Impedance Spectroscopy (NLEIS) in galvanostatic mode for the rapid, non-destructive assessment of metal degradation. By using galvanostatic mode instead of traditional potentiostatic methods, polarization-related challenges are mitigated, enabling more accurate and reliable analysis. The technique allows for the determination of corrosion rates (corrosion current)...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublikacjaThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
The impact of air humidity on the operation of proton exchange membrane fuel cells determined using dynamic electrochemical impedance spectroscopy
PublikacjaThis paper describes the changes in the fuel cell impedance across a range of current loads and humidity changes. The changes of each equivalent circuit parameters representing specific processes occurring in fuel cells, as a function of humidity and current changes, were determined. Within the combined scope of current and humidity, the optimal working conditions of the cells were determined, corresponding to the lowest impedance...
-
Identification of Non-Stationary Magnetic Field Sources Using the Matching Pursuit Method
Publikacja -
Electro-optical system for the automated selection of dental implants according to their colour matching
Publikacja -
Static and dynamic approach of social roles identification using PISNA and subgraphs matching
PublikacjaIdentyfikacja ról w sieci społecznej jest jednym z podstawowych zagadnień analiza takich sieci. W artykule przedstawiamy nowe podejście do tego zagadnienia. Pokazujemy w jaki sposób można dokonać identyfikacji ról poprzez tworzenie specjalnych struktur grafowych tzw. grafów wzorcowych. Przy definiowaniu tychże grafów wspieramy się metodą PISNA. Proponujemy statyczne i dynamiczne podejście do identyfikacji ról. Pokazujemy, w jaki...
-
Exploring application relationships within enterprise system by matching messages in enterprise log
PublikacjaWith data becoming their key asset, large enterprises require data governance processes to maintain its quality. Because a large portion of business value in enterprise systems is usually delivered by legacy applications without proper documentation, there is a need for a better understanding of these applications and the data produced by them. In this paper, we present an approach to collecting insights into the data managed by...
-
Identification of the mechanical properties of the skin by electromechanical impedance analysis of resonant piezoelectric actuator
PublikacjaThis paper is devoted to the analysis and verification of developed piezoelectric sensor/actuator for measuring the mechanical properties of soft tissues, especially human skin. The key element of the measurement structure is an electromechanical system that uses both the reverse piezoelectric effect (vibration generation – stimulation of the tissues in the appropriate frequency range) and direct piezoelectric effect (system response...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
PublikacjaSurface oxidation processes play a key role in understanding electrochemical properties of boron-doped diamond (BDD) electrodes. The type of surface termination groups, which create the potential window of electrolytic water stability or hydrophobicity, influences such properties. In this study the kinetics of oxidation process under anodic polarization were studied in situ by means of Dynamic Electrochemical Impedance Spectroscopy...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Impedance monitoring of fuel cell stacks
Publikacja -
Local impedance spectra of organic coatings
Publikacja -
Local impedance spectra of organic coatings
PublikacjaPublikacja przedstawia nowe podejście do lokalnych spektroskopowych pomiarów impedancyjnych powłok organicznych, oparte o mikroskop sił atomowych pracujący w trybie kontaktowym. Pomiędzy nieporuszającą się igłę mikroskopu i podłoże metalowe pokryte powłoką epoksydową przyłożono serię sinusoidalnych napięciowych sygnałów pobudzenia w zadanym zakresie częstotliwości. W ten sposób zarejestrowano lokalne widma w trybie "frequency by...
-
Analyzer for spectroscopy of low-impedance objects
PublikacjaW artykule przedstawiono analizator umożliwiający pomiar impedancji w zakresie 1 ohma < |Zx| < 100 Mohma. Zastosowano w nim nowe rozwiązania dotyczące obwodu wejściowego i techniki detekcji fazoczułej sygnałów pomiarowych. Obwód wejściowy zaprojektowano w postaci 5-zaciskowej sondy pomiarowej, która umożliwia ograniczenie wpływu rezystancji, indukcyjności i pojemności pasożytniczych na błąd pomiaru impedancji w szerokim przedziale...
-
Impedance spectroscopy of single chamber SOFC.
PublikacjaMechanizm działania jednokomorowego ogniwa paliwowego SOFC, które pracuje w mieszaninie powietrza i paliwa, nie jest do końca zbadany. W tej pracy przedstawiono wyniki badań ogniwa paliwowego zbudowanego z tlenku cyrkonu stabilizowanego itrem jako nośnego elektrolitu, cermetu z tlenku niklu jako anody i perovskitu LSCF jako katody w temperaturach 500-700C z użyciem mieszaniny propanu i powietrza. Wykorzystując spektroskopię impedancyjną...
-
Impedance spectroscopy of undoped cerium oxide.
PublikacjaW pracy przedstawiono badania impedancyjne niedomieszkowanego tlenku ceru. Wyniki wskazują na występowanie zjawiska dyfuzji,???? które nie są (.. jest.?)związane z odpowiedzią elektrodową. Rozważania teoretyczne dopuszczają obserwowanie impedancji Warburga, która reprezentuje zjawisko dyfuzji w przewodnikach mieszanych, jednakże niewiele informacji na ten temat można znaleźć w literaturze. W związku z tym szczegółowe badania zródła...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublikacjaWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
The electrochemical impedance spectroscopy studies of the anode material based on polymer and starch derived ceramic for lithium ion batteries
PublikacjaThe anode materials derived of preceramic polymer poly(1,2-dimethylsilazane) (PSN) and starch was study. Commercially available polysilazane (poly(1,2-dimethylsilazane (PSN 2M01 Gelest) was mixed with commercially available starch (POCH Gliwice). The ratio polymer/starch (PSN/starch) was 1/1 or 3/7. The polysialazane/starch blend was cross-linked at 230 ºC for 2 h followed by heating to the final temperature (500 ºC, 700 ºC and...
-
Sensing the onset of epoxy coating degradation with combined Raman spectroscopy/atomic force microscopy/electrochemical impedance spectroscopy
PublikacjaThe paper presents the results of investigation on epoxy resin durability upon 12-week exposure to UV radiation. The aim was early determination of the onset of epoxy degradation and for this purpose an epoxy film on steel substrate systems were periodically inspected using Raman spectroscopy, atomic force microscopy and electrochemical impedance spectroscopy. The behaviour of examined polymer could be divided into three periods: immunity,...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublikacjaThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Application of matching pursuit based method to identify sources of time-vary magnetic field
Publikacja -
Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters With Reduced Switch Count
Publikacjahis paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along with simulation and experimental verification are also provided. Possible application fields are discussed, as well as advantages and disadvantages....
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublikacjaThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Mesoscopic impedance analysis of solid materials’ surface
Publikacja -
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publikacja -
The time dependence of pit creation impedance spectra
Publikacja -
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publikacja -
Continuous frequency method of measurement of electrode impedance.
PublikacjaPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Impedance measurements of coating properties on bridge structures
PublikacjaPomiary impedancyjne pozwalają na prostą ocenę właściwości ochronnych powłok ochronnych i wykładzin. Pomiary stosuje się w celu porównania powłok, monitorowania ich właściwości i oceny mechanizmu działania. Metodyka jest z powodzeniem stosowana w pomiarach laboratoryjnych. Pomiary terenowe są bardziej skomplikowane ponieważ wymagają w pełni kontrolowanych komputerowo przyrządów, kontroli warunków pogodowych oraz wielu innych parametrów...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions.
PublikacjaUstalona została ciągła transformata STFT sinusoidalnego sygnału pobudzeniai odpowiedzi prądowej dla pierwszorzędowej reakcji elektrodowej. Impedancja elektrodowa wyznaczona została w łącznej dziedzinie czasowo-częstotliwościowej. Wykonano pomiary reakcji redukcji Cd(II) na kapiącej elektrodzie rtęciowej w funkcji czasu. Zaprezentowano możliwość wyznaczania chwilowych widm impedancyjnych. Opisano czasowe charakterystyki rezystancji...
-
On the characteristic impedance definition in microstrip and coplanar lines
PublikacjaW niniejszej pracy rozważono definicję impedancji charakterystycznej dla bezstratnych linii mikropaskowych i koplanarnych. Wykazano, że ze względu na znaczne wartości prądu przesunięcia związanego z podłużną składową pola elektrycznego, definicja impedancji staje się niejednoznaczna. W rezultacie może to przyczyniać się do istotnych błędów powstających już na etapie projektowania układów. Pokazano, iż efekt ten jest szczególnie...
-
Mesoscopic impedance analysis of solid materials surface
PublikacjaSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
The time dependence of pit creation impedance spectra.
PublikacjaPrzeprowadzono pomiar impedancyjny w warunkach chronoamperometrycznych uzyskując zmiany impedancji układu w czasie. Na ich podstawie wyznaczono zmiany rezystancji przeniesienia ładunku i pojemności w czasie opisujące inicjację i rozwój korozji wżerowej. Potwierdzono użyteczność dynamicznej elektrochemicznej spektroskopii impedancyjnej w badaniu korozji wżerowej.
-
A metrological analysis of the input circuit of an impedance meter.
PublikacjaW pracy przeprowadzono analizę obwodu wejściowego miernika impedancji W analizie obwodu wejściowego, uwzględniono najważniejsze czynniki wpływające na sygnały na jego wejściu: parametry zmiennoprądowe zastosowanych wzmacniaczy, rezystancję zakresową przetwornika prąd-napięcie, pojemności montażowe. Przeprowadzono symulację sygnałów wydzielanych w obwodzie dla różnych wartości pojemności pasożytniczych, następnie dokonano badań...
-
Change of myocardial impedance during experimental ischemia.
PublikacjaW pracy omówiono możliwość monitorowania procesu niedotlenienia za pomocą pomiarów immitancyjnych. Przedstawiono skonstruowane stanowisko pomiarowe ze szczególnym uwypukleniem właściwości sondy pomiarowej. Przedstawiono wyniki eksperymentalnego niedotlenienia u świń wywołanego zamknięciem LAD.
-
Evaluation of coating systems using impedance spectroscopy
PublikacjaTrwałość powłokowych systemów ochronnych zależy od oddziaływań środowiska i związana jest nieodwracalnymi procesami chemicznymi i fizycznymi. Zastosowanie spektroskopii impedancyjnej pozwala na określenie obszaru zastosowań danej powłoki i prognozowanie okresu jej trwałości. W pracy zamieszczono przykłady oceny trwałości systemów powłokowych stosowanych w strategicznych konstrukcjach.
-
Advances in electrical impedance methods in medical diagnostics
PublikacjaOmówiono elektroimpedancyjne metody diagnostyczne i aparaturę pomiarową opracowane w Politechnikach - Gdańskiej i Warszawskiej.Przedyskutowano właściwości elektryczne różnych tkanek biologicznych, omówiono konstrukcję celek i elektrod do pomiarów in vivo oraz in vitro. Opisano konstrukcję wybranych systemów pomiarowych - pletyzmografów, kardiografów i tomografów elektroimpedancyjnych a także stosownego oprogramowania, np. rekonstrukcji...
-
Study on surface termination of boron-doped diamond electrodes under anodic polarization in H2SO4 by means of dynamic impedance technique
PublikacjaAnodic oxidation is a popular way to modify termination bonds at boron doped diamond electrodes altering their electrochemical and physicochemical properties. Our studies, performed with dynamic electrochemical impedance spectroscopy technique, supported with X-ray photoelectron spectroscopy and ellipsometry analysis prove its utility in continuous on-line monitoring of impedance changes on the electrode surface under polarization...
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublikacjaIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublikacjaIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Fundamental-harmonic impedance of first-order electrode reactions
Publikacja -
Determination of electrode impedance by means of exponential chirp signal
Publikacja