Filtry
wszystkich: 36
wybranych: 30
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: electroanalysis
-
Microwave-Induced Processing of Free-Standing 3D Printouts: An Effortless Route to High-Redox Kinetics in Electroanalysis
Publikacja3D-printable composites have become an attractive option used for the design and manufacture of electrochemical sensors. However, to ensure proper charge-transfer kinetics at the electrode/electrolyte interface, activation is often required, with this step consisting of polymer removal to reveal the conductive nanofiller. In this work, we present a novel effective method for the activation of composites consisting of poly(lactic...
-
Comparison of Cadmium Cd2+ and Lead Pb2+ Binding by Fe2O3@SiO2‐EDTA Nanoparticles – Binding Stability and Kinetic Studies
PublikacjaThis study describes the synthesis and characterization of ethylenediaminetetraacetic acid (EDTA) functionalized magnetic nanoparticles of 20 nm in size – Fe3O4@SiO2‐EDTA – which were used as a novel magnetic adsorbent for Cd(II) and Pb(II) binding in aqueous medium. These nanoparticles were obtained in two‐stage synthesis: covering by tetraethyl orthosilicate and functionalization with EDTA derivatives. Nanoparticles were characterized...
-
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publikacja -
Differences in Electrochemically Deposited PEDOT(PSS) Films on Au and Pt Substrate Electrodes: A Quartz Crystal Microbalance Study
Publikacja -
Lower Rim Substitutedp-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based onp-tert-Butyl-calix[4]arene Thioamides
Publikacja -
Influence of aprotic solvent on selectivity of an amperometric sensor with nafion membrane
PublikacjaW publikacji przedstawiono rezultaty badań dotyczące selektywności amperometrycznego czujnika ditlenku siarki z membraną nafionową wobec tlenku węgla i dwutlenku azotu jako interferentów. Zostały porównane współczynniki selektywności dla czujników wypełnionych roztworami elektrolitów zawierających wodne roztwory kwasu siarkowego i różne ilości rozpuszczalnika aprotycznego - dimetylosulfotlenku.
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublikacjaSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Composite Bioelectrodes Based on Lipidic Cubic Phase with Carbon Nanotube Network
PublikacjaElektrody z węgla szklistego modyfikowane fazą kubiczną z siecią nanorurek zastosowano do enzymatycznej redukcji tlenu katalizowanej przez lakazę. Zastosowanie nanorurek obniżyło nadpotencjał redukcji tlenu o 0,5 V. W celu zwiększenia gęstości prądu redukcji tlenu zastosowano znany mediator przeniesienia elektronów - ABTS. Mediator adsorbowano na nanorurkach lub wiązano kowalencyjnie z końcami nanorurek. Kowalencyjne związanie...
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublikacjaTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
Influence of Analyte Flow Rate on Signal and Response Time of the Amperometric Gas Sensor with Nafion Membrane
PublikacjaW publikacji przedstawiono rezultaty badań nad wpływem zmian objętościowego natężenia przepływu gazu na sygnał i czas odpowiedzi prototypowego czujnika ditlenku siarki z membraną nafionową. Porównywano właściwości czujników różniących się materiałem elektrody pracującej oraz składem roztworu elektrolitu wewnętrznego. Zastosowano elektrody pracujące wykonane z napylonych próżniowo na powierzchnię membrany nafionowej złota i platyny....
-
Spectroelectroanalytical properties of antitumor agent C1311
PublikacjaZastosowano kilka metod woltamperometrycznych dla charakterystyki właściwości elektrochemicznych przeciwnowotworowej pochodnej imidazoakrydonu o symbolu C-1311. Wyniki wskazały, że możliwym będzie zastosowanie metod elektrochemicznych do badania oddziaływań badanego związku z DNA. Badania spektroelektrochemiczne ujawniły, że oscylacyjne zmiany absorbcji związku obserwowane po cyklicznej polaryzacji elektrody. Oscylacje te znikały...
-
Lower Rim Substituted tert-Butyl Calix[4]arenes (Part IV). Calix[4]arene-Crown Ethers as Ionophores in Plasticized PVC-membrane electrodes.
PublikacjaPrzedstawiono syntezę i charakterystykę trzech p-tert-butylokaliks[4]aren-koron-4, -5, -6 (związki 2 - 4 o różnej długości łańcucha polyoksaetylenowego łączącego distalne grupy OH). Syntezowane związki wykazują wysoką selektywność na kationy sodu, potasu lub cezu. Badano zależność pomiędzy stereochemiczną strukturą tych ligandów, a wyznaczonymi potencjometrycznie współczynnikami selektywności oraz wyznaczonymi stałymi trwałości...
-
Conventional and solid-contact lithium-selective electrodes based on tris(N,N-dicyclohexylamide) neutral ionophore
PublikacjaKonstruowano jonoselektywne elektrody litowe (Li-ISEs) z membraną polimerową i obojętnym jonoforem tris(N,N-dicycloheksyloamidem) jako: elektrodę konwencjonalną (z wodnym roztworem elektrolitu wewnętrznego) oraz ze stałym kontaktem (polianilina jako przekaźnik jonowo-elektronowy). Charakterystyki obu elektrod (nachylenie i zakres liniowy) są porównywalne. Badana elektroda ze stałym kontaktem wykazuje dobrą stabilność w czasie....
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Interactions of dissolved dsDNA with intercalating drug by anodic voltammetry and spectroscopy. Influence of pH
PublikacjaOddziaływanie związku przeciwnowotworowego C-1305 z DNA było badane przy pomocy impulsowej voltametrii różnicowej oraz spektroskopii UV/Vis. Triazoloakrydon C-1305 oddziałuje z DNA na dwóch drogach: przez interkalacje pomiedzy pary zasad oraz przez wiązanie sie w małym rowku helisy. W fizjologicznym pH (7,4) stałe wiązania wynoszą: K1=3,36E+5 i K2=0,18E+5 [1/M] a wielkość miejsca wiązania: n1=2,5 i n2=4,0, odpowiednio dla pierwszego...
-
Synergic Effect of Naphthylated Carbon Nanotubes and Gold Nanoparticles on Catalytic Performance of Hybrid Films Containing Bilirubin Oxidase for the Dioxygen Reduction
PublikacjaTo improve the direct electron transfer from a multicopper oxidase MvBOd to the glassy carbon electrode surface the naphthylated multiwall carbon nanotubes (Napht-MWCNTs) are ombined with gold nanoparticles (AuNPs) to form a conductive network at the electrode and to increase its working surface. Such approach allowed to eliminate the necessity of employing mediators to reach elevated current values. The enzyme stability was improved...
-
Melamine-modified boron-doped diamond towards enhanced detection of adenine, guanine and caffeine
PublikacjaThis work describes the electrochemical method of boron-doped diamond (BDD) modification by poly-melamine to obtain organic film. The detection of adenine, guanine and caffeine were carried out by differential pulse wave voltammetry. The poly-melamine modified B-NCD electrodes exhibit excellent activity towards the electrochemical oxidation of all examined analytes. The poly-melamine modified BDD electrodes in all measurements...
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublikacjaThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublikacjaThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
An electrochemical biosensor for the determination of hormone Human Chorionic Gonadotropin (hCG) in human serum
PublikacjaThis work describes the modification of a gold electrode to create an electrochemical biosensor capable of detecting human chorionic gonadotropin (hCG). The biosensor was obtained by modifying the gold electrode with cysteamine and oligopeptide (PPLRINRHILTR). The modification steps of the gold electrode were confirmed by cyclic voltammetry (CV) and impedance electrochemical spectroscopy (EIS) measurements. The conducted EIS experiments...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublikacjaHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublikacjaThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Optimizing Ni–Cr patterned boron-doped diamond band electrodes: Doping effects on electrochemical efficiency and posaconazole sensing performance
PublikacjaThere is growing interest in developing diamond electrodes with defined geometries such as, for example, micrometer-sized electrode arrays to acquire signals for electroanalysis. For electroanalytical sensing applications, it is essential to achieve precise conductive patterns on the insulating surface. This work provides a novel approach to boron-doped diamond patterning using nichrome masking for selective seeding on an oxidized...
-
Unlocking the electrochemical performance of glassy carbon electrodes by surface engineered, sustainable chitosan membranes
PublikacjaChitosan coatings, derived from crustacean shell waste, possess inherent biocompatibility and biodegradability, rendering them suitable for various biomedical and environmental applications, including electrochemical biosensing. Its amine and hydroxyl functional groups offer abundant sites for chemical modifications to boost the charge transfer kinetics and provide excellent adhesion, enabling the construction of robust electrode-coating...
-
Diamondized carbon nanoarchitectures as electrocatalytic material for sulfate-based oxidizing species electrogeneration
PublikacjaThe introduction of nanotechnology seems to be an imperative factor to intensify the synergic effects of electrocatalytic materials to produce strong oxidant species or to increase the active sites on their surfaces as well as to enhance the conversion yield in a fuel cell, high-added value products, electrolytic treatment for environmental protection or the detection limit in electroanalysis. Recently, a new type of 3D-diamond...
-
Phospholipid-functionalized gold electrode for cellular membrane interface studies - interactions between DMPC bilayer and human cystatin C
PublikacjaThis work describes the electrochemical studies on the interactions between V57G mutant of human cystatin C (hCC V57G) and membrane bilayer immobilized on the surface of a gold electrode. The electrode was modified with 6-mercaptohexan-1-ol (MCH) and 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC). DMPC was used as a membrane mimetic for monitoring electrochemical changes resulting from the interactions between the functionalized...
-
Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate
PublikacjaThis work describes fabrication of gold electrodes modified with peptide conjugate DAL-PEG-DK5-PEG-OH that enables ultra-sensitive detection of lipopolysaccharide (LPS) isolated from the reference strain of Escherichia coli O26:B6. The initial step of the established procedure implies immobilization of the fully protected DAL-PEG-DK5-PEG-OH peptide on the surface of the gold electrode previously modified by cysteamine. Then side...
-
Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications
PublikacjaThis paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials’ architecture and the receptor immobilisation procedures. The study...
-
Tailoring diamondised nanocarbon-loaded poly(lactic acid) composites for highly electroactive surfaces: extrusion and characterisation of filaments for improved 3D-printed surfaces
PublikacjaA new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added as fillers in poly(lactic acid) (PLA)-based composites to extrude 3D filaments. Carbon black served as a primary filler to reach high composite conductivity at low diamondised nanocarbon concentrations (0.01 to 0.2...
-
Deciphering the Molecular Mechanism of Substrate-Induced Assembly of Gold Nanocube Arrays toward an Accelerated Electrocatalytic Effect Employing Heterogeneous Diffusion Field Confinement
PublikacjaThe complex electrocatalytic performance of gold nanocubes (AuNCs) is the focus of this work. The faceted shapes of AuNCs and the individual assembly processes at the electrode surfaces define the heterogeneous conditions for the purpose of electrocatalytic processes. Topographic and electron imaging demonstrated slightly rounded AuNC (average of 38 nm) assemblies with sizes of ≤1 μm, where the dominating patterns are (111) and...