Wyniki wyszukiwania dla: SUBSURFACE VERTICAL FLOW BED
-
Performance of subsurface vertical flow constructed wetlands receiving municipal wastewater.
PublikacjaPrzedstawiono skuteczność pracy oczyszczalni hydrofitowych z pionowym przepływem ścieków. Wsazano jak usuwanie azotu uzależnione jest od temperatury, podobnie usuwanie ładunkuu BZT5. Wskazano na różnice w pracy oczyszczalni w okresie lata i zimy.
-
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublikacjaThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
Nitrogen removal in vertical flow constructed wetlands: influence of bed depth and high nitrogen loadings
PublikacjaThe aim of the study was to evaluate the nitrogen removal and its effects on the plant’s growth and leaves morphology. using two subsurface vertical flow (VF bed), with different depths (0.24 m2 × 0.70 m; 0.24 m2 × 0.35 m) and nitrogen load increments. The VF bed were planted with Vetiveria zizanioides, filled with light expanded clay aggregates (Leca®NR 10/20) and fed in parallel mode with synthetic wastewater. High ammonium nitrogen...
-
Removal of persistant organic pollutants from landfill leachates treated in three constructed wetland systems
PublikacjaThe objective of the study was assessment of occurrence and removal of two groups of persistent organic pollutants: polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) in landfill leachate (LL) treated in three constructed wetland systems (CWs) of different construction and flow regime. Two subsurface flow systems (SSF) were analyzed: one with horizontal flow and the second one consisting of two vertical...
-
Pollutants removal effectiveness in hydrophyte filters with sequential vertical and horizontal flow
PublikacjaThe object of investigations was the constructed wetland in Wiedersberg in Saxonia in Germany supplied with domestic sewage from 145 inhabitants. The biological part was composed of sequential reed beds with vertical and horizontal flow of sewage. It in one of new solutions, because up till now configuration with vertical bed situated at front of biological part of treatment was applied.The evaluation of object performance was...
-
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
PublikacjaEco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical...
-
Procesy i efektywność usuwania zanieczyszczeń z odcieków ze składowisk odpadów komunalnych w oczyszczalniach hydrofitowych
PublikacjaOczyszczanie odcieków z SOK jest jednym z najbardziej istotnych problemów ekologicznych na świecie. Odprowadzenie odcieków do oczyszczalni ścieków komunalnych jest przeważnie niemożliwe, ze względu na ich zmienną ilość oraz skład, bardzo wysokie stężenia ChZT i azotu amonowego, a także obecność trwałych zanieczyszczeń organicznych (TZO) oraz metali ciężkich. Najlepszym rozwiązaniem jest oczyszczanie wód odciekowych na terenie składowiska....
-
Temperature Impact of Nitrogen Transformation in Technological System: Vertical Flow Constructed Wetland and Polishing Pond
PublikacjaThe article describes the results of the research, purpose of which was to evaluate influence of the temperature on the effectiveness of nitrification and denitrification in the sewage treatment system consisting of vertical flow constructed wetland and polishing pond. During the analysed period, the efficiency of removing total nitrogen was low and amounted to 12.7%. In the polishing pond in the summer period, content of total...
-
Kinetics of pollutants removal in vertical and horizontal flow constructed wetlands in temperate climate
PublikacjaThis paper reports a comparative study on kinetics of organic matter expressed as BOD5 and nitrogen removal in constructed wetlands operated in Poland. Analyzed data were collected at eight wetland systems, composed of subsurface flow beds: horizontal flow (HF) and vertical flow (VF), in different number and sequences. The analysis involved particularly mass removal rates (MRR) and first-order removal rate coefficients of BOD5...
-
OPERATIONAL PROBLEMS OF CONSTRUCTED WETLAND FOR LANDFILL LEACHATE TREATMENT: CASE STUDY
PublikacjaThe present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006...
-
Effectiveness of pollutants removal in hybrid constructed wetlands – different configurations case study
PublikacjaIn recent years, an increase in interest in hybrid constructed wetland systems (HCWs) has been observed. The aim of the paper is to compare different HCW configurations in terms of mass removal rates and efficiency of pollutants removal. Analysed data have been collected at multistage constructed wetlands in Poland, which are composed by at least two beds: horizontal subsurface flow (SSHF) and vertical subsurface flow (SSVF). The...
-
Operational problems of constructed wetland for landfill leachates treatment: case study
PublikacjaIn the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed.The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent...
-
Removal of organic matter and nitrogen in an horizontalsubsurface flow (HSSF) constructed wetland undertransient loads
PublikacjaA monitoring campaign in a horizontal subsurface flow constructed wetland under the influence of transient loads of flow-rate, organic matter, nitrogen and suspended solids showed an irregular removal of COD and TSS and lower both removal efficiencies and mass removal rates than the ones observed in other studies for similar operating conditions. This circumstance is associated to the presence of large amount of particulate organic...
-
Treatment Wetland for Overflow Stormwater Treatment: The Impact of Pollutant Particles Size
PublikacjaThe problem of stormwater treatment in urban areas has become increas- ingly crucial. It has been widely recognized that both mechanical and biological treatment of stormwater is necessary to protect surface water against pollution. Moreover, technology must be applied to ensure effective treatment in changing hydraulic conditions and to serve, to the extent possible, as a retention volume. Treatment wetland (TW) could be...
-
Constructed wetlands systems for wastewater treatment in Poland
PublikacjaOczyszczalnie hydrofitowe mogą stanowić interesującą alternatywę dla konwencjonalnych rozwiązań gospodarki ściekowej na terenach o rozproszonej zabudowie. Celem pracy była ocena działania i skuteczności usuwania zanieczyszczeń w hybrydowych systemach hydrofitowych pracujących w rejonie Gdańska, w klimacie umiarkowanym.Technologiczne rozwiązanie składające się z osadnika gnilnego oraz złoża hydrofitowego z podpowierzchniowym przepływem...
-
Efficiency of Wastewater Treatment in Single-Family Constructed Wetlands in Kaszuby Lake District
PublikacjaIn the paper results of investigation upon three different configurations of single family treatment wetlands were presented. It was indicated that the application of treatment wetlands for single family effluent is a effective and sustainable solution for wastewater treatment in the rural areas. In spite of the receiving higher concentration of pollutants in comparison to the TWs operated in Europe and USA analysed TWs ensure...
-
Fluctuation of nitrogen fraction during wastewater treatment in a multistage treatment wetland
PublikacjaFactors influencing COD and removal and transformation of N fractions have been investigatedin the conditions of horizontal (SSHF) and vertical (SSVF) flow reed beds. Multistage treatment wetlandin Wiklino ensured a stable and very effective removal of all the analysed pollutants. Based onthe resultsof investigation, it could be assumed that the working conditions of SSHF beds play an importantrole in the transformation of particulate...
-
Partitioning of heavy metals in sub-surface flow treatment wetlands receiving high-strength wastewater
PublikacjaThe retention of heavy metals at two pilot-scale treatment wetlands (TWs), consisting of two vertical flow beds (VSSF) followed by a horizontal flow bed (HSSF) was studied. The TWs received highstrength wastewater: reject waters from sewage sludge centrifugation (RW) and landfill leachate (LL). The concentrations of metals: Fe, Mn, Zn, Al, Pb, Cu, Cd, Co, Ni were measured in treated wastewater, substrate of the beds and in plant...
-
Kinetics of pollutants removal in hybrid treatment wetlands – Case study comparison
PublikacjaRecent years have seen an increasing interest in hybrid constructed wetland (HCW) systems for domestic sewage treatment. This paper is focused on kinetics of removal of the main pollutants occurring in wastewater i.e. organics expressed as chemical oxygen demand, biochemical oxygen demand and total nitrogen. The purpose of the article is to compare different HCW configurations in terms of mass removal rates (MRR) and removal rate...
-
Single-Family Treatment Wetlands Progress in Poland
PublikacjaLong distances from one farm to another as well as unfavourable terrain configuration in rural areas in Poland result in high investment and operation costs of sewerage systems. Treatment wetlands (TWs) can be an alternative solution to sewage treatment in rural communities, schools, at campsites and for single houses. In this paper the results of 4 years monitoring of single-family treatment plants (SFTWs) in Kaszuby Lake...
-
Reliability and efficiency of pollution removal during long-term operation of a one-stage constructed wetland system with horizontal flow
PublikacjaThe paper presents the results of a study of the reliability and efficiency of pollutant removal during long term operation of a one-stage constructed wetland system with horizontal flow. The flow rate of the wastewater treatment plant was 1.2 m3·d-1 during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the years 1997–2010 (14 years). During this study period, 56 series...
-
The role of SSVF and SSHF beds in concentrated wastewater treatment, design recommendation
PublikacjaThe return flows of reject water from sewage sludge dewatering alter the activated sludge process ina conventional WWTP and increase TN concentration in the final effluent from WWTP. The objectiveof the investigation carried out was to consider the application of multistage treatment wetland(MTW) for the treatment of reject water from sewage sludge dewatering in a centrifuge (RWC). Thispaper aims to present the design and performance...
-
Assessment of the technological reliability of a hybrid constructed wetland for wastewater treatment in a mountain eco-tourist farm in Poland
PublikacjaThe aim of the present study was to assess the technological reliability of a domestic hybrid wastewater treatment installation consisting of a classic three-chambered (volume 6 m3) septic tank, a vertical flow trickling bed filled with granules of a calcinated clay material (KERAMZYT), a special wetland bed constructed on a slope, and a permeable pond used as a receiver. The test treatment plant was located at a mountain eco-tourist...
-
Recent developnents in wastewater treatment in constructed wetlands in Poland
PublikacjaNowadays more than 100 constructed wetlands are in operation in Poland. Most of them are one stage wetland systems with horizontal subsurface flow. Such constructed wetlands ensure efficient removal of organic matter (BOD5, CODCr) and suspended solids but efficiency of nitrogen compounds removal in many cases is insufficient.In the period from 1995 to 2003 measurements of removal of contaminations in 11 individual pilot household...
-
Orientation effects on the fracture behaviour of additively manufactured stainless steel 316L subjected to high cyclic fatigue
PublikacjaIn this paper, stainless steel 316L (SS316L) bars were additively manufactured (AM) in three orientations (Z – vertical, XY – horizontal, ZX45 – midway between vertical and horizontal) by using the Laser Powder Bed Fusion Melting (LPBF-M) method. The AM specimens were subjected to load control fatigue testing under full tension and compression (R = -1) at stress amplitudes ±350, ±400 and ±450 MPa. The XY and ZX45 printing orientations...
-
25 years of research and experiences about the application of constructed wetlands in southeastern Poland
PublikacjaThis paper is a review of research and experiences related to the application of constructed wetland systems (CWs) in southeastern Poland in 1992–2016. On the basis of literature data, a comparison between pollutant removal efficiencies of one-stage and hybrid CWs was made. Some problems regarding the operation of these treatment plants were also presented. Data from various facilities indicate that one-stage CWs with horizontal...
-
Evaluation of respiration capacity of VF in hybrid constructed wetland systems.
PublikacjaThree VF-beds operating in hybrid constructed wetlands in configuration HF-VF-HF were analysed. These hybrid constructed wetlands provide the II stage biological treatment. They are located in Pommerania voivodship, in Sarbsk, Wiklino and Wieszyno, and their capacities are 29.5, 14.2 and 21.6 m3/d, respectively. The article focuses on performance and operation of VF-CW plants during one year. Based on removal of organic matter...
-
Development of models for nitrogen-removal processes in subsurface flow constructed wetlands
PublikacjaThis paper summarizes recent progress in modelling approach of subsurface flow constructed wetlands (SSF CWs), focusing on nitrogen removal processes.
-
Spetiation of organic matter in Vertical Flow Constructed Wetlands
PublikacjaThe object of the research were VFCWs which are a component of biological treatment of two hybrid hydrophyte systems located in Wieszyno and Wiklino, close to Słupsk, Poland. The facilities that are subject to analyses are unified in terms of structure (filtration material, depth of the bed and time of operation), but they differ in organic matter load, amounting respectively to: 8.0 gCOD/m2day and 31.0 gCOD/m2day.The intensity...
-
An Integrated Approach to an Assessment of Bottlenecks for Navigation on Riverine Waterways
PublikacjaWater transport, both sea and inland, is the cheapest, least invasive, and safest option for non-standard loads; hence, it is important to increase the percentage share of inland waterway transport on the rivers of Central and Eastern Europe. Transporting cargo is particularly difficult on shallow waterways because rivers overloaded with sediment determine the vertical parameters on inland waterways. A ship’s safe manoeuvrability...
-
Potential and limits of landfill leachate treatment in a multi-stage subsurface flow constructed wetland – evaluation of organics and nitrogen removal
PublikacjaConstructed wetlands have potential of treating wastewater of poor biodegradability. The performance of a multistage sub-surface flow wetland treating municipal landfill leachate was assessed during three years of operation. During the study three research periods with different operation conditions were established. The hydralic loads, operation mode of vertical flow beds and type of treated wastewater (raw leachate – leachate...
-
The efficiency and technological reliability of biogenic compounds removal during long-term operation of a one-stage subsurface horizontal flow constructed wetland
PublikacjaThe paper presents the results of a study of the efficiency and technological reliability of total nitrogen and total phosphorus removal during long term operation of a one-stage constructed wetland system with subsurface horizontal wastewater flow. The flow rate of the wastewater treatment plant was 1.2m3/d during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the...
-
Flow boiling of R1233zd(E) in a 3 mm vertical tube at moderate and high reduced pressures
PublikacjaThe results of flow boiling of R1233zd(E) in a 3 mm vertical stainless steel tube are presented at moderate and high saturation temperatures. Integral flow characteristics in the form of pressure drop and heat transfer coefficient are discussed for saturation temperatures ranging from 115 to 145 °C (corresponding reduced pressures from 0.2 to 0.7), mass velocity of 800 kg/m2s and heat flux of 20 kW/m2. All of the obtained heat...
-
Dariusz Mikielewicz prof. dr hab. inż.
OsobyDariusz Mikielewicz – urodził się 6 lutego 1967 roku w Gdańsku, w 1985r. zdał pomyślnie egzaminy wstępne na Wydział Budowy Maszyn Politechniki Gdańskiej, który ukończył z wynikiem bardzo dobrym w 1990 roku na specjalności Maszyny i Urządzenia Energetyczne. Zainteresowania pracą naukową skłoniły go do podjęcia badań na University of Manchester na wydziale mechanicznym i energetyki jądrowej (Mechanical and Nuclear Engineering Department)...
-
Long-term hindcast simulation of currents in the Baltic Sea
Dane BadawczeThe dataset contains the results of numerical modelling of currents over a period of 50 years (1958-2007) in the Baltic Sea . A long-term hindcast simulation was performed using a three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). The hydrodynamic model was coupled...
-
Two-dimensional vertical analysis of dam-break flow
PublikacjaW artykule przedstawiono matematyczne modelowanie przepływów ze swobodną powierzchnią w kanałach otwartych. Do symulacji przepływu użyto dwuwymiarowy pionowy model RANS. Wchodzące w skład modelu równania Naviera-Stokesa rozwiązano stosując algorytm SIMPLE dla metody różnic skończonych. Do śledzenia zmian swobodnego zwierciadła wody zastosowano metodę MAC. Analizie poddano szybkozmienny przepływ po poziomym, gładkim dnie wywołany...
-
The numerical simulation of two-dimensional vertical incompressible viscous flow
PublikacjaW artykule przedstawiono numeryczne symulacje płaskiego pionowego przepływu nieściśliwej cieczy lepkiej ze swobodną powierzchnią. Zastosowano model bazujący na rozwiązaniu równań Naviera-Stokesa metodą "ciśnień" (SIMPLE). Przy takim podejściu otrzymano dywergencję równań Naviera-Stokesa oraz równanie Poissona na ciśnienie. W rozwiązaniu zastosowano schemat Laxa-Wendroffa z przesuniętą siatką Eulera. Takie podejście zapewnia dokładność...
-
Application of vertical flow cw for highly contaminated wastewater treatment
PublikacjaBasing on quantitative and qualitative characteristics of reject waters generated during digested sewage sludge dewatering on centrifuges in conventional WWTP (RWC) and municipal landfill leachate (LL), the pilot constructed wetlands for treatment of both types of highly contaminated wastewater were designed. In the paper the characteristics of the pilot plants and assumed treatment efficiencies are presented. According to the...
-
Application of stereology for two-phase flow structure validation in fluidized bed reactors
Publikacja -
Experimental and theoretical study of flow boiling and dryout phenomenon of ethanol in vertical minitubes
PublikacjaW ramach przeprowadzonych prac zaadoptowano istniejące stanowisko do badań laminarnej konwekcji wymuszonej, wrzenia w przepływie oraz wysychania filmu cieczy na ściance kanału wykorzystując etanol jako płyn roboczy. Przeprowadzono systematyczne badania wrzenia w przepływie dla dwóch średnic rur, tj. 1.15mm i 2.3mm. W badaniach wykorzystano najnowsze osiągnięcia z zakresu technik termowizyjnych celem znalezienia dokładnej lokalizacji...
-
Experimental investigations on pressure drop during the condensation in flow of HFE7000 in vertical minichannel
PublikacjaIn the work presented in the paper authors focused attention on the issues of flow resistance and pressure drop during condensation in the flow. The case of the descending flow through a cylindrical single-channel of 2.3 mm inner diameter was carefully analyzed. In the course of investigations a new working fluid HFE 7000 has been scrutinised which has a strongly differing properties in comparison to the other fluids that are commonly...
-
Application of vertical flow constructed wetlands for highly contaminated wastewater treatment: preliminary results
PublikacjaBasing on quantitative and qualitative characteristics of reject waters (RWC) generated during dewatering of digested sewage sludge on centrifuges in conventional WWTP and municipal landfill leachate (LL), the pilot constructed wetlands for treatment of both types wastewater were designed and built. In the paper the conception, design and assumed treatment efficiencies of the pilot plants are presented. The water balance of the...
-
The flow of nitrogen into the euphotic zone of the Baltic Proper as a result of the vertical migration of phytoplankton: An analysis of the long-term observations and ecohydrodynamic model simulation
Publikacja -
Two-dimensional vertical Reynolds-averaged naviers-stokes equations versus one-dimensional Saint-Venant model for rapidly varied open channel water flow modelling
PublikacjaPrzedstawiono dwa modele przepływu wody ze swobodną powierzchnią -płaski pionowy model Reynoldsa i model de Saint-Venanta.Do rozwiązania równań pierwszego modelu zastosowano schemat SIMPLE oraz wykorzystano metodę cząstek znaczonych MAC do wyznaczania swobodnej powierzchni wody. Równania Saint-Venanta rozwiązano metodą objętości skończonych. Obydwa modele zastosowano do symulacj zjawiska typu katastrofa zapory. Porównano wyniki...
-
Janusz Cieśliński prof. dr hab. inż.
OsobyUrodził się 15 kwietnia 1954 r. w Słupsku. Jest absolwentem Wydziału Budowy Maszyn Politechniki Gdańskiej (1978), z którą związał całe swoje życie zawodowe. W 1986 r. obronił doktorat, w 1997 r. – habilitację, w 2006 r. – uzyskał tytuł profesora. Pełnił funkcje prodziekana ds. nauki Wydziału Mechanicznego przez dwie kadencje (2002–2008) oraz kierownika: Katedry Maszyn Przemysłu Spożywczego (2002–2006), Katedry Ekoinżynierii i...
-
Possible effects of the 1984 St. Clair River ice jam on bed changes
PublikacjaThis study examines the possible effect of the record ice jam of 1984 in the St. Clair River on river bed changes and conveyance. Numerical simulations were made to examine the flow and bed shear stresses during the jam formation and release periods. Simulation results indicate that the ice jam in the river did not cause a significant increase in bed shear stress compared to pre- and post-jam open water conditions. The insignificant...
-
Experimental study on the seepage flow through the ice jam
PublikacjaIn light of the observed climate change, there is a need for better understanding of river ice processes for managing water resources in the cold regions. Ice jams produce significant resistance which may cause rise of water level and flooding. The jam resistance is only referred to the roughness of its underside, and this approach lead to exceptional roughness coefficients which has no physical explanation. Number of evidences...
-
Data points of structures of R1233zd(E) flowing in a circular minichannel at low, medium and high values of saturation pressure
Dane BadawczeDatabase present structures of two-phase flow of R1233zd(E) in 3 mm vertical channel. Database contains datapoints which contain information of reduced pressure (ratio of saturation pressure and critical pressure), quality and mass velocity. 4 two phase structures are distinguished: bubbly flow, slug flow, intermittent flow and annular flow.
-
Landfill leachate treatment at a pilot plant using hydrophyte systems
PublikacjaConstructed wetlands can provide an effective and economical solution to landfill leachate treatment. In the article the performance of a CW for leachate treatment, consisting of two horizontal flow constructed wetlands (HF-CW) beds, working at the municipal landfill in Gdansk-Szadolki in the period 2004-2005 is being discussed. The plant has been operating since 2001. Clogging problems and surface flow occurred in the system...
-
Numerical Solution of the Two-Dimensional Richards Equation Using Alternate Splitting Methods for Dimensional Decomposition
PublikacjaResearch on seepage flow in the vadose zone has largely been driven by engineering and environmental problems affecting many fields of geotechnics, hydrology, and agricultural science. Mathematical modeling of the subsurface flow under unsaturated conditions is an essential part of water resource management and planning. In order to determine such subsurface flow, the two-dimensional (2D) Richards equation can be used. However,...