Filtry
wszystkich: 4532
-
Katalog
- Publikacje 3258 wyników po odfiltrowaniu
- Czasopisma 68 wyników po odfiltrowaniu
- Konferencje 7 wyników po odfiltrowaniu
- Osoby 46 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 20 wyników po odfiltrowaniu
- Dane Badawcze 1130 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OPTICAL VELOCITY MEASUREMENT
-
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Czasopisma -
Numerical simulation of cold flow and combustion in a swirl stabilized combustor
PublikacjaA numerical simulation model was developed to investigate the cold flow and combustion using Ansys FLUENT 2021R1. The governing equations were solved using the pressure-based method, and pressure–velocity coupling was performed using the SIMPLE method. To model the turbulent process, the RSM model was used. Non-premixed model is chosen to solve the chemical kinetics between fuel and oxigen. Radiation heat transfer was calculated...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublikacjaTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Outlet Flow Velocity In Circular Culvert
PublikacjaThe outlet flow velocity in the end section of the culvert barrel depends in most cases on the culvert geometry, including the barrel slope, as well as on upstream and downstream channel parameters. Flowing water can create pressure flow or free surface flow in the culvert barrel. In the case of an unsubmerged barrel outlet, the free-surface flow is more frequent than the full flow. Increased velocities can cause channel bed scour...
-
MEASUREMENT OF NOISE IN SUPERCAPACITORS
PublikacjaA developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublikacjaIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
Measurements and Measurement Systems [2022/23]
Kursy OnlineOpis kursu: (np. numer semestru, dla którego przeznaczony jest kurs, cel lub tematyka przedmiotu) IV semestr kierunku Energy Technologies. Celem kursu jest zapoznanie teoretyczne i praktyczne studentów z podstawowymi i zaawansowanymi metodami pomiarowymi różnych wielkości pomiarowych oraz budową i zasadą działania systemów pomiarowych. The aim of the course is to introduce theoretical and practical students with basic...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Computer Support of Analysis of Optical Spectra Measurements
PublikacjaThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...
-
Electrohydrodynamic flow patterns and collection efficiency in narrow wire-cylinder type electrostatic precipitator
PublikacjaRecently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore,...
-
Nondestructive global corrosion measurement using guided wavefield data
PublikacjaMetallic structures often face degradation, and corrosion ranks among the most prevalent forms of deterioration. Accurate quantification of corrosion is crucial, especially for structures exposed to harsh environmental conditions, such as marine vessels and offshore installations. Because the traditional measurement methods based on scanning by ultrasonic gauge are time-consuming and provide only rough information on the thickness...
-
Sylwester Kaczmarek dr hab. inż.
OsobySylwester Kaczmarek ukończył studia w 1972 roku jako mgr inż. Elektroniki, a doktorat i habilitację uzyskał z technik komutacyjnych i inżynierii ruchu telekomunikacyjnego w 1981 i 1994 roku na Politechnice Gdańskiej. Jego zainteresowania badawcze ukierunkowane są na: sieci IP QoS, sieci GMPLS, sieci SDN, komutację, ruting QoS, inżynierię ruchu telekomunikacyjnego, usługi multimedialne i jakość usług. Aktualnie jego badania skupiają...
-
Intelligent Measurement Systems
Kursy Online -
Photonics measurement techniques
Kursy Onlinestart zajęć 10 listopada terminy zajęć 10.11, 17.11, 24.11, 1.12 --> w tych wszystkich dniach godz. 13-14 w sali EA07 i 14-15 w sali EA20 terminy zajęć 18.11, 25.11, 2.12 --> w tych wszystkich dniach godz. 13-15 w sali NE232
-
Intelligent Measurement Systems
Kursy Online -
Optical flow method for measuring deformation of soil specimen subjected to torsional shearing
PublikacjaIn this study optical flow method was used for soil small deformation measurement in laboratory tests. The main objective was to observe how the deformation distributes along the whole height of cylindrical soil specimen subjected to torsional shearing (TS test). The experiments were conducted on dry non-cohesive soil specimens under two values of isotropic pressure. Specimens were loaded with low-amplitude cyclic torque to analyze...
-
Velocity Field Characteristics at the Inlet to a Pipe Culvert
PublikacjaA poorly designed culvert inlet structure causes scouring, which can lead to the collapse of the culvert and significant damage to the neighboring land. A set of laboratory tests was evaluated to examine velocity distribution at the culvert inlet. A three-dimensional acoustic Doppler velocimeterwas used to measure instantaneous flowvelocity upstream of the culvert. The analysis of mean velocities, turbulence strength, and Reynolds...
-
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS
Czasopisma -
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublikacjaDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Diamond-based protective layer for optical biosensors
PublikacjaOptical biosensors have become a powerful alternative to the conventional ways of measurement owing to their great properties, such as high sensitivity, high dynamic range, cost effectiveness and small size. Choice of an optical biosensor's materials is an important factor and impacts the quality of the obtained spectra. Examined biological objects are placed on a cover layer which may react with samples in a chemical, biological...
-
Practical issues for the implementation of survivability and recovery techniques in optical networks
PublikacjaFailures in optical networks are inevitable. They may occur during work being done for the maintenance of other infrastructures, or on a larger scale as the result of an attack or large-scale disaster. As a result, service availability, an important aspect of Quality of Service (QoS), is often degraded. Appropriate fault recovery techniques are thus crucial to meet the requirements set by the Service Level Agreements (SLAs) between...
-
Computer support of analysis optical spectra measurements
PublikacjaVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Optical profilometer
PublikacjaThe profilometry plays a huge role in the most fields of science and technology. It allows to measure the profile of the surface with high-resolution. This technique is used in the fields like optic, electronic, medicine, automotive, and much more. The aim of the current work was to design and build optical profilometer based on the interference phenomena. The developed device has been working with He-Ne laser (632.8 nm). The optical...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublikacjaA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublikacjaPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
Disaster Resilience of Optical Networks: State of the Art, Challenges, and Opportunities
PublikacjaFor several decades, optical networks, due to their high capacity and long-distance transmission range, have been used as the major communication technology to serve network traffic, especially in the core and metro segments of communication networks. Unfortunately, our society has often experienced how the correct functioning of these critical infrastructures can be substantially hindered by massive failures triggered by natural...
-
Investigations of the optical activity of nonlinear crystals by means of dual-wavelength polarimeter
PublikacjaA dual-wavelength method in high accuracy polarimetry has been successfully tested and applied to measure optical activity (OA) of nonlinear crystals. In proposed polarimetric scheme two neighboring semiconductor laser wavelengths (635 and 650 nm) are used, which increases number of parameters measured simultaneously and improves the data processing. By neglecting dispersion of eigen wave ellipticity in crystals, more efficient...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublikacjaIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Przykłady realizacji i interpretacji wyników sondażowych pomiarów terenowych w czynnych systemach wodociągowych
PublikacjaW pracy przedstawiono przebieg realizacji i rezultaty sondażowych pomiarów terenowych w trzech układach dystrybucji wody o zróżnicowanym przewymiarowaniu sieci wodociągowej. Pomiary przeprowadzono w dążeniu do identyfikacji właściwości (cech) strukturalnych i funkcjonalnych układów po wieloletniej ich eksploatacji. Ustalenia te determinują opracowanie programu realizacji pomiarów dla potrzeb tarowania komputerowego modelu przepływu...
-
Przykłady realizacji i interpretacji wyników sondażowych pomiarów terenowych w czynnych systemach dystrybucji wody
PublikacjaW pracy przedstawiono przebieg realizacji i rezultaty sondażowych pomiarów terenowych w trzech układach dystrybucji wody o zróżnicowanym przewymiarowaniu sieci wodociągowej. Pomiary przeprowadzono w dążeniu do identyfikacji właściwości (cech) strukturalnych i funkcjonalnych układów po wieloletniej ich eksploatacji. Ustalenia te determinują opracowanie programu realizacji pomiarów dla potrzeb tarowania komputerowego modelu przepływu...
-
Badawczo-rozwojowe laboratorium sieci optycznych wykorzystujące sprzęt ADVA Optical Networking
PublikacjaPrzedstawiono uwarunkowania i kierunki zmian w sieciach optycznych, a następnie wskazano na potrzebę posiadania laboratorium, w którym możliwe byłoby prowadzenie prac badawczo-rozwojowych oraz kształcenie. Przedstawiono koncepcję takiej sieci opartej na sprzęcie ADVA Optical Networking zrealizowaną w Katedrze Sieci Teleinformacyjnych Wydziału ETI PG. Opisano możliwości sprzętowo-funkcjonalne tego laboratorium oraz prowadzone prace...
-
Petrophysical analyses of rock construction materials from the Roman rural settlement in Podšilo bay on Rab island (NE Adriatic, Croatia)
PublikacjaThis article presents the results of petrophysical analyses of limestones and sandstones used for the construction of the wall structures of a Roman rural settlement located in Podšilo Bay on Rab Island (Croatia). An on-site analysis of the walls indicated the use of different lithotypes, which is an uncommon case in the area. So far, no petrophysical properties of the applied materials have been tested, and their provenance...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures
PublikacjaThis paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment...
-
Effects of subfilter velocity modelling on dispersed phase in LES of heated channel flow
PublikacjaA non-isothermal turbulent flow with the dispersed phase is modelled using the Large Eddy Simulation (LES) approach for fluid, one-way coupled with the equations of point-particle evolution. The channel is heated at both walls and isoflux boundary conditions are applied for fluid. Particle velocity and thermal statistics are computed. Of particular interest are the r.m.s. profiles and the probability density function of particle...
-
Wpływ azotowania jarzeniowego i laserowego nadtapiania na odporność kawitacyjną stali X5CrNi18-10
PublikacjaNierdzewne stale austenityczne charakteryzują się doskonałą odpornością korozyjną, aczkolwiek niskimi właściwościami mechanicznymi. W wielu przypadkach ogranicza to ich eksploatację w warunkach przemysłowych. Ponadto, nierdzewne stale austenityczne są wrażliwe na korozję lokalną w obecności jonów halogenkowych. Technologie materiałowe, które dają potencjalne możliwości otrzymywania korzystnego wpływu na właściwości mechaniczne...
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublikacjaThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Analytical Study of Sliding Instability due to Velocity- and Temperature-Dependent Friction
PublikacjaThe instability of sliding causes deterioration of performance characteristics of tribosystems and is undesired. To predict its occurrence, the motion of a body of a one-degree-of-freedom system with friction is investigated about the steady sliding equilibrium position. The motion equation is formulated with the friction coefficient dependent on the sliding velocity and contact temperature changing due to transient heat conduction...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Fundamentals of Optical Fibers and Photonics - 2021/2022
Kursy OnlineTechnika światłowodowa i fotonika: 2 st. 2 sem., kierunek elektronika i telekomunikacja
-
Fundamentals of Optical Fibers and Photonics - 2023/2024
Kursy OnlineTechnika światłowodowa i fotonika: 2 st. 2 sem., kierunek elektronika i telekomunikacja
-
The field–dependent interface recombination velocity for organic–inorganic heterojunction
PublikacjaWe have derived an analytical formula which describes the field–dependent interface recombination velocity for the boundary of two materials characterized by different permittivities. The interface recombination of charge carriers has been considered in the presence of image force Schottky barrier. We suggest that this effect may play an important role in the loss of current for organic–inorganic hybrid heterojunctions. It has...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublikacjaAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublikacjaThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
5G/6G optical fronthaul modeling: cost and energy consumption assessment
PublikacjaIn fifth generation (5G) and the future beyond 5G (6G) radio access networks (RANs), the cost of fronthaul deployment is a main challenge for mobile network operators. Depending on different constraints, there are various solutions to deploy an efficient fronthaul. Fiber-optic-based fronthaul offers long-term support with regard to a rapid increase in capacity demands. When fiber connections, either point-to-point (P2P) or point-to-multipoint...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Dane BadawczeOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...