Filtry
wszystkich: 415
Wyniki wyszukiwania dla: friction
-
Influence of the grains shape on the mechanical behavior of granular materials
PublikacjaDiscrete Element Method is a numerical method suitable for modeling geotechnical problems concerning granular media. In most cases simple forms of grains, like discs or spheres, are used. But these shapes are capable of soil behavior modeling up to a certain point only, they cannot reflect all of the features of the medium (large shear resistance and large volumetric change). In order to reflect the complex behavior of the real...
-
Preparation and Characterization of Diamond-like Carbon Coatings for Biomedical Applications—A Review
PublikacjaDiamond-like carbon (DLC) films are generally used in biomedical applications, mainly because of their tribological and chemical properties that prevent the release of substrate ions, extend the life cycle of the material, and promote cell growth. The unique properties of the coating depend on the ratio of the sp3/sp2 phases, where the sp2 phase provides coatings with a low coefficient of friction and good electrical conductivity,...
-
Parametry mechaniczne platformy roboczej na podstawie badań DMT
PublikacjaNośność platformy roboczej określana jest w sposób analogiczny do nośności podłoża uwarstwionego, w którym warstwa wierzchnia zbudowana z gruntu niespoistego spoczywa na słabonośnym podłożu z gruntu spoistego. Badanie DMT wykorzystano do wyznaczenia parametrów wytrzymałościowych podłoża (kąta tarcia wewnętrznego warstwy górnej i wytrzymałości na ścinanie bez odpływu podłoża słabonośnego) oraz do wyznaczenia modułu odkształcenia...
-
Discussion on “Coupled effective stress analysis of insertion problems in geotechnics with the Particle Finite Element Method” by L. Monforte, M. Arroyo, J.M. Carbonell, and A. Gens
PublikacjaAddressed here is the Particle Finite Element Method (PFEM) modelling of undrained CPTu penetration with regard to a reference analytical solution based on the Spherical Cavity Expansion Method (SCEM). Also discussed is the choice of the soil model and its parameters. The effect of cone interface friction on CPTu simulation is analyzed in a series of penetration tests using Arbitrary Lagrangian-Eulerian (ALE) and Updated Lagrangian...
-
Should we seek further improvement of fluid film bearings - what for and how?
PublikacjaFluid film bearings have been extensively used in the industry because of their unbeatable durability and extremely low friction coefficient. Large bearings supporting shafts of huge and important rotating machines constitute a special group of fluid film bearings since the reliability of crucial systems, like for example electro-energetic system, rely on their trouble-free operation. Large thrust bearings, apart from enormous...
-
Experimental comparison of hydrodynamic thrust bearings with different pad surface materials
PublikacjaBabbitt is the material most frequently used as the pad surface material for hydrodynamic bearings operating at usual operating conditions. It shows many advantages important for safe bearing operation, as for example: low friction coefficient, corrosion resistance, fair mechanical properties and outstanding conformability. On the other hand, it is not free from disadvantages, such as limited fatigue strength or limited resistance...
-
Large Hydrodynamic Thrust Bearings and Their Application in Hydrogenerators
PublikacjaLarge hydrodynamic thrust bearings are the bearings which, due to hydrodynamic lubrication, allow large axial load to be transferred from a moving part (shaft) to the stationary part via a thin layer of the lubricant (usually oil), thus providing extremely low friction and practically no wear. Hydrogenerators with vertical shafts are the most important application of large thrust bearings. Main design and scientific problems of...
-
Experimental and analytical thermal study of PTFE composite sliding against high carbon steel as a function of the surface roughness, sliding velocity and applied load
PublikacjaThis study investigates the contact temperatures caused by frictional heating of sliding parallel pairs. In this case the materials studied are a PTFE composite in contact with a high carbon steel plate. These materials are commonly used for industrial applications, in particular as the main contacting components within a scroll expander system. The expected contact temperature values are important to be quantified in order to...
-
A case study of robust sliding mode control applied to inverted pendulum on a cart
PublikacjaA control problem of an inverted pendulum on a cart has been addressed in this paper. In particular, a synthesis of alternative sliding mode control for stabilisation of an inverted pendulum at an upper equilibrium point has been investigated. Hence, the feasibility of implementing the developed control system, taking into account primarily the friction of the cart against the gantry and the limited length of the gantry, in a real...
-
FEM ANALYSIS AND EXPERIMENTAL TESTS OF RIGID RISER HANGING SYSTEM
PublikacjaThe article presents the analysis, project, and experimental examination of an original rigid riser for Coil Tubing Pipes. The principle of riser operation is based on the use of friction forces. The research included the FEM analysis of the designed riser, calculations of the required bolt tensions, and checking the effect of the clamping force on stress distribution in the pipeline. The results of computer simulation were verified...
-
THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THIN-WALLED BEARING SHELL’S DESIGN PARAMETERS AND ASSEMBLY CONDITIONS ON THE HOLDING TORQUE INSIDE A HOUSING BORE OF A CONNECTING ROD
PublikacjaThe aim of the work was the experimental and theoretical evaluation of the influence of the most important parameters determining the holding torque of a thin-walled bearing shell inside a housing bore of a connecting rod. The main investigated parameters were defned by authors experience in this feld. In the frst stage of research, a special test stand was designed in order to allow measuring the real values of the friction torque...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Multi Parameter Sliding Test Result Evaluation for The Selection of Material Pair for Wear Resistant Components of a Hydraulic motor Dedicated for Use With Environmentally Friendly Working Fluids
PublikacjaIn the paper the method and results are presented of the testing of tribological performance of a number of hard materials available commercially. The tests consisted in unidirectional sliding with liquid lubrication. The load and velocity regime chosen were similar to a standard four-ball lubricity test with constant velocity and load increasing over time. The regime was modified in such a way that over the initial part of the...
-
A numerical study on optimal FTMD parameters considering soil-structure interaction effects
PublikacjaThe study on the performance of the nonlinear friction tuned mass dampers (FTMD) for the mitigation of the seismic responses of the structures is a topic that still inspires the efforts of researchers. The present paper aims to carry out a numerical study on the optimum tuning of TMD and FTMD parameters using a multi-objective particle swarm optimization (MOPSO) algorithm including soil-structure interaction (SSI) effects for...
-
Research on water lubricated main shaft bearings in conditions of improper lubrication and cooling conducted on high torque real-life scale bush test rig
PublikacjaWater lubricated polymer bushes find increasingly popular use in the sliding bearings of marine propellers, water turbines and pump shafts. Such popularity is partly due to their simple construction which also means relatively affordable price. In addition, properly designed and installed water lubricated bearings may well last for over a decade. However, in practical experience one may also observe cases of rapid wear...
-
Mechanical performance investigations of a post-tensioned inter-module connection in steel buildings
PublikacjaConnections in modular steel structures are critical for maintaining structural integrity and facilitating ease of installation. Traditional methods, such as on-site welding, require adherence to complex technical specifications. In contrast, post-tensioned steel bolts offer a viable alternative by potentially reducing on-site labor by up to 50 %, providing substantial strength and simplifying assembly. To accurately assess the...
-
Direct design of Controlled Modulus Columns (CMC) based on in-situ testing
PublikacjaIn this paper, the serviceability limit state and bearing capacity of tension screw displacement piles were analyzed using the results of static pile load tests, carried out on the test plot near the Elbląg city, and field, and laboratory tests. The paper presents the methodology of determining the pile load-settlement curve using different types of t-z transfer functions. The new method of constructing the pile load-settlement...
-
Numerical estimation of the pile toe and shaft unit resistances during the installation process in sands
PublikacjaNumerical simulations of a pile jacking were carried out. A Coupled Eulerian–Lagrangian (CEL) formulation was used to treat with large deformation problems. An Abaqus, a commercial Finite Element Method software suit, was used as a computing environment. The Mohr–Coulomb constitutive model was applied and the Coulomb model of friction was used to describe pile-soil interaction. Calculations were made for three different pile diameters....
-
A comprehensive approach to double inverted pendulum modelling
PublikacjaThe problem of mathematical modelling and indication of properties of a DIP has been investigated in this paper. The aim of this work is to aggregate the knowledge on a DIP modelling using the Euler-Lagrange formalism in the presence of external forces and friction. To indicate the main properties important for simulation, model parameters identification and control system synthesis, analytical and numerical tools have been used....
-
From flow to jamming: Lattice Gas Automaton simulations in granular materials
PublikacjaWe introduce the first extension of a Lattice Gas Automaton (LGA) model to accurately replicate observed emergent phenomena in granular materials with a special focus on previously unexplored jamming transitions by incorporating gravitational effects, energy dissipation in particle collisions, and wall friction. We successfully reproduce flow rate evolution, density wave formation, and jamming transition observed in experiments....
-
Experimental study of the post tensioned prestressed concrete corbels
PublikacjaThe results of experimental investigation of 6 symmetrical double prestressed corbels of variable shear span to depth ratio and variable location of prestressing bars are presented in the paper. The post ten- sioned corbels were prestressed with Macalloy 1030 bars of 25 mm in diameter. The results of the tests were compared with the cracking and load carrying capacity of corbels reinforced with passive reinforce- ment. As a result...