Filtry
wszystkich: 283
Wyniki wyszukiwania dla: pulse rate
-
MnWO4/reduced graphene oxide-based electrochemical sensing platform for simultaneous detection of catechol and resorcinol
Publikacjan this study, a novel electrochemical sensor for accurate and sensitive catechol determination was demonstrated employing a screen-printed graphite electrode (SPGE) modified with MnWO4/reduced graphene oxide (MnWO4/rGO) nanocomposite. The MnWO4/rGO nanocomposite has been successfully prepared by using hydrothermal technique, and it was then characterized using several microscopic and spectroscopic methods (XRD, FE-SEM, and EDS)....
-
Use of optical skin phantoms for calibration of dermatological lasers
PublikacjaA wide range of dermatological diseases can be efficiently treated using laser heating. Nevertheless, before the new laser is introduced into clinical practice, its parameters and ability to interact with human skin have to be carefully examined. In order to do that optical skin phantoms can be used. Such phantoms closely imitate the scattering and absorption properties of real human skin tissue along with its thermal properties,...
-
Error analysis of calculating average d-q current components using Regular Sampling and Park transformation in FOC drives
PublikacjaIn electric drives using voltage source inverters, motor currents contain ripple component resulting from pulse-width modulated (PWM) voltage. The frequency range of the ripples is much higher than the bandwidth of current control. Therefore the control is performed on the basis of a fundamental current component, i.e. average value with the averaging time being the PWM period. In majority of cases the average current is measured...
-
Exhaust gas temperature measurements in diagnostics of turbocharged marine internal combustion engines. Part I. Standard measurements.
PublikacjaThe article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard...
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublikacjaPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Simultaneous opto-electrochemical monitoring of carbamazepine and its electro-oxidation by-products in wastewater
PublikacjaThe growing human impact on aquatic environments, due to the extensive use of pharmaceuticals and the release of persistent pollutants, makes it necessary to implement new widespread methods for the characterisation and quantification of such contaminants and relative degradation products. Carbamazepine, 5H-dibenzo[b,f]azepine-5-carboxamide, (CBZ) is a widely used anti-epileptic drug, characterised by its limited removal by conventional...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublikacjaThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
A Five-Leg Three-Level Dual-Output Inverter
PublikacjaClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Locally sculptured modification of the electrochemical response of conductive poly(lactic acid) 3D prints by femtosecond laser processing
PublikacjaThis manuscript presents an approach to sculpture high electrochemical activity of the 3D printed electrodes with poly(lactic acid) (PLA) matrix and carbon black (CB) filler by femtosecond laser (FSL) ablation. CB-PLA utility for electrochemical applications depends on a surface modification aiming to remove the PLA and uncover the conductive CB. We have discussed how laser pulse energy is critical for such an activation process....
-
New nanoadsorbent based on magnetic iron oxide containing 1,4,7,10-tetraazacyclododecane in outer chain (Fe3O4@SiO2-cyclen) for adsorption and removal of selected heavy metal ions Cd2+, Pb2+, Cu2+
PublikacjaMagnetic Fe3O4@SiO2-cyclen nanoparticles were prepared and used as adsorbent for Cd2+, Pb2+ and Cu2+ from aqueous solution removal process controlled with differential pulse anodic stripping voltammetry (DPASV) and hanging mercury drop electrode (HDME). Nanomaterial was synthesised in three-step process co-precipitation of Fe3O4 core, coating with silane and N-(3-(triethoxysilyl)propyl)-1,4,7,10-tetraazacyclododecane-1-carboxamide...
-
Mode shapes of a beam and plate with defects, obtained by experimental modal analysis
Dane BadawczeThe DataSet contains the experimental results of the first mode shape for a beam and a plate.
-
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublikacjaNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
In vivo imaging of the human eye using a two-photon excited fluorescence scanning laser ophthalmoscope
PublikacjaBACKGROUND. Noninvasive assessment of metabolic processes that sustain regeneration of human retinal visual pigments (visual cycle) is essential to improve ophthalmic diagnostics and to accelerate development of new treatments to counter retinal diseases. Fluorescent vitamin A derivatives, which are the chemical intermediates of these processes, are highly sensitive to UV light; thus, safe analyses of these processes in humans...
-
Electrochemical determination of neurotransmitter serotonin using boron/nitrogen co-doped diamond-graphene nanowall-structured particles
PublikacjaElectrode fouling is a major issue in biological detection due to the adhesion of the protein itself and polymerization of biomolecules on the electrode surface, impeding the electron transfer ability and decreasing the current response. To overcome this issue, the use of anti-fouling material, especially boron-doped diamond (BDD) electrode, is an alternative way. However, the electrocatalytic activity of BDD is inadequate compared...
-
A new concept of PWM duty cycle computation using the Barycentric Coordinates in a Three-Dimensional voltage vectors arrangement
PublikacjaThe paper presents a novel approach to the Pulse Width Modulation (PWM) duty cycle computing for complex or irregular voltage vector arrangements in the two (2D) and three–dimensional (3D) Cartesian coordinate systems. The given vectors arrangement can be built using at least three vectors or collections with variable number of involved vectors (i.e. virtual vectors). Graphically, these vectors form a convex figure, in particular,...
-
The optimization of enzyme immobilization at Au-Ti nanotextured platform and its impact onto the response towards glucose in neutral media
PublikacjaThe market of non-invasive glucose sensors is drastically growing due to increasing number of people suffering from diabetes. Therefore, there is a significant need for any improvement in the field of biosensors that can be used for monitoring glucose level in human body. In recent years the emphasis is put onto the modification of electrode material with enzymes possessing recognition centre specific towards particular molecules....
-
Interactions between bioactive components determine antioxidant, cytotoxic and nutrigenomic activity of cocoa powder extract
PublikacjaNumerous studies have shown, rather disappointingly, that isolated bioactive phytochemicals are not as biologically effective as natural plant products. Such a discrepancy may be explained by the concept of food synergy, which was verified in this research for cocoa extract versus its major components with regard to cancer chemoprevention. The evaluation embraced the relationship between redox properties evaluated in cell-free systems...
-
The influence of the Cu2O deposition method on the structure, morphology and photoresponse of the ordered TiO2NTs/Cu2O heterojunction
PublikacjaThe increased interest in highly ordered titania structures exhibiting tubular shape that could be directly formed onto the stable substrate is related with the intensive research on their modification enabling absorption of light within the wide solar spectrum and its further conversion into electric or chemical energy. Among others, formation of uniform 3D heterojunctions based on the TiO2 nanotubes attracts attention since porous...
-
Tailoring diamondised nanocarbon-loaded poly(lactic acid) composites for highly electroactive surfaces: extrusion and characterisation of filaments for improved 3D-printed surfaces
PublikacjaA new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added as fillers in poly(lactic acid) (PLA)-based composites to extrude 3D filaments. Carbon black served as a primary filler to reach high composite conductivity at low diamondised nanocarbon concentrations (0.01 to 0.2...
-
UWB Microstrip Antennas on a Cylindrical Surfaces
PublikacjaConformal antennas are becoming popular due to their many advantages and possibilities of applications they offer. The advantages of using antennas with a curved surface arise not only from the possibility of integrating them with the object on which they are mounted on but also from the increase, relatively to planar antennas, of their visible angular range. The circular antenna arrays, or arrays of radiators located on the surface...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublikacjaExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Towards spectral sensitivity curve for two-photon vision mechanism
PublikacjaAbstract Purpose: The perceived brightness of different visible light sources can be compared with photometric units based on the standardized luminosity curves (300-780nm range). As reported previously (PNAS 111(50), pp. E5445-E5454 (2014)), near-infrared (NIR) radiation can cause isomerization of visual pigments by one- or two-photon absorption. The perceived color of the stimulus is red in the case of one-photon vision (1PV)...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of ultrasonic bulk and guided wave propagation in additively manufactured cubes and plates obtained by ultrasonic pulse velocity analyzer and scanning laser vibrometry
Dane BadawczeThe DataSet contains the results of measurements of ultrasonic wave propagation in additively manufactured samples made of polylactic acid (PLA). Three types of raster angles in two consecutive layers were assumed: 0°/90° (#1), 45°/-45° (#2) and 90°/90° (#3) with respect to the x-axis. For each printing variants a cubic sample (#C1-3) with dimensions...
-
Simulation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe aim of the research is investigation of the efficiency of weight averaging of pulse frequency modulated signal. It was shown that from the point of view of the reduction of the sampling error the best are polynomial weighing functions, for which the maximum of this component error decreases proportionally to the appropriate power of the number of...
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...